Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #40279618

Tender For Special Rep For Replacement Old Deteriorated Earthing System At Certain Locations, Conversion Of 1-Phase Electric Supply To 3-Phase Supply In Omqs And Replacement Of Dbs In Smq Area At Afs Sarsawa Under Ge ( Af ) Sarsawa

Issued by Statutory Bodies & Commissions/Committees · sarsawa, Uttar Pradesh
Tender Value
39 Lakhs
Estimated cost
Bid Submission
08 Nov 2023
0 days left
EMD
78000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
sarsawa → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Special Rep For Replacement Old Deteriorated Earthing System At Certain Locations, Conversion Of 1-Phase Electric Supply To 3-Phase Supply In Omqs And Replacement Of Dbs In Smq Area At Afs Sarsawa Under Ge ( Af ) Sarsawa

BOQ

Name of Work: SPL REP FOR REPLACEMENT OLD DETERIORATED EARTHING SYSTEM AT CERTAIN LOCATIONS, CONVERSION OF 1-PHASE ELECTRIC SUPPLY TO 3-PHASE SUPPLY IN OMQS AND REPLACEMENT OF DBS IN SMQ AREA AT AFS SARSAWA UNDER GE(AF) SARSAWA
Sl. No. Item Description
1Section-1Taking down DB including old U/s MCB/MCCB/Isolator box of any size any type from any location complete all as specifed and directed.
2Taking down old US single phase submain wiring including old conduits clamps etc of any size from any location complete all as specifed and directed.
3S & F in replacement ofsub main wiring with PVC insulated, FRLS, unsheathed four single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including concealed PVC conduit ofsize not less than 25 mm dia as directedwith and including one run of6.0 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etcconnected and tested complete all as specified and as directed.Note: (i) Four runs of 6.0 sqmm cable and one run of 6.0sqmm cable of earth continuity conductor and PVC conduit shall be a unit length.
4S & F in replacement ofsub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including concealed PVC conduit of any size and type with and including one run of6.0 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etcconnected and tested complete all as specified and as directed.Note:(i) Two runs of 6.0 sqmm cable and one run of 6.0sqmm cable of earth continuity conductorshall be a unit length.
5S & Fin replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including Concealed Concealed PVC conduit of suitable size as directed with and including one run of4.0 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etcconnected and tested complete all as specified and as directed.Note:(i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
6S & FRegid non-metallicPVCconduit25 mm(external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etccomplete all as specified and as directed.
7S&F in replacement of Double doorprewired distribution board4 way TPN when MCB to be used as incomer powder coated with Bus Bar200 Amps, 415 V, Earth Stud, Din Rail, with IP 43 protection complete all as specified and directed (Note- (a) MCBs are to be measured and paid seperately. (b)Make ofMCBs and DB should be same. (c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate. Make- Legrand/L&T/Schneider
8S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 8 ways 240 V including fixing in new location with connection of circuit and submain as per site requirementwith IP 43 protection complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make ofMCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate. Make- Legrand/L&T/Schneider
9S&F in replacement MCB TPN 40Amps,240 volts,curve \"B\", breaking capacity 10 KA, all as specified.
10S&F in replacement MCB TPN 63 Amps,240 volts,curve \"B\", breaking capacity 10 KA, all as specified.
11S&F in replacement MCB SP 5 to 32 Amps,240 volts curve \"B\",breaking capacity 10KA,all as specified.
12S&F in replacement MCB SPN16 to 40 Amps,240 volts,curve \"B\", breaking capacity 10 KA, all as specified.
13Supply and fixing in repair ofEarthing to DBs with Galvanisedsteel pipe electrode shall be of medium grade 40 mm dia and 2.5 m in length. Pipe electrode shall be cut tapered at the bottom and is provided with 12 mm dia holes (staggered) at 75 mm centre to centre upto 2 m of length from bottom. The electrode shall be buried directly in ground vertically with its top edge not less than 1.25 m below ground levelconnected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.2 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board includingexcavation in any type of soil,returning filling, disposal of soil, providing alternate layer ofcharcoal dust and common salt upto top edge of electrode, construction of PCC pit with RCC cover, funnel,including testing on completion complete all as specified and as directed. Note- cost of Making good of disturbed surface/area to match with existing surface is deemed to be included in the quoted rate.
14M & L for Earth continuity conductor or main earthing lead of 4.0 Sqmm galvanized iron wire, buried in ground or fixed to wall in and including 15 mm bore GI pipe medium grade for protection of earth wire complete all as specified and directed. Note- cost of Making good of disturbed surface/area to match with existing surface is deemed to be included in the quoted rate.
15Dismantling/Taking out old unserviceable earthing any type/size complete all as specified and directed.
16Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core all as specified and directed.
17Boring of holes under road, pavement, hard standing by trenchless technologyand necessary toolincluding HDPE pipe of 40 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
18Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar Complete all as specified and directed.
19Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness Complete all as specified and directed.
20M& L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete.
21M&L for coloured Chequered cement concrete tiles 300X300X25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments complete all as specified and as directed by Engr-in-Charge
22M&L for 20mm thick screed bed or bedding layer of mortar CM 1:6 for laying floor finishes complete all as specified and as directed by the Engr-in-charge.
23Excavation in trenches in soft/loose soilnot exceeding 1.5 meter wide & not exc 1.5 mtrdeep and getting out for taking out/laying cable, poles & stay etc complete all as specified and directed by engr-in-charge.
24M & Lfor dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying ( total 23 cm ) and compaction till 18 cm thick for measurement purpose complete all as specified and directed .
25M & L for common burnt clay bricks, sub class \"B\" grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
26Returning, filling in including spresding leveling watering and well ramming in layersnot exceeding 25cm thick after the cable have been laid and tested complete all as specified and directed by Engr-in-Charge..
27Removal of excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
28M&L for GI pipes 50 mm dia light grade for cable protection in trenches / poles/Wall complete all as specified and as directed.
29Section-2Taking out old unserviceable strip/wire any type from wall/roof complete all as specified and directed
30Supply and fix aluminium strip of size 25x3.15 mm for Earth continuity conductor or main earthing lead fixed to wall/ roof with saddles and fixing screws etc. for roof conductors and down conductors above ground or any other indicated situation complete all as specified and directed.Note:- Two lengths of strips shall be jointed together by overlapping not less than 100 mm both ends through welding/brazing.
31Supply and fix copper strip of size 20x3.15 mm for Earth continuity conductor or main earthing lead fixed wall/ roof with saddles and fixing screws etc. for roof conductors and down conductors above ground or any other indicated situation complete all as specified and directed.
32Supply and fix GI strip of size 32x6 mm for Earth continuity conductor or main earthing lead fixed wall with saddles and fixing screws etc. or laid underground as in grid connection of earthing complete all as specified and directed.
33Taking down old unserviceable single pointed termination rod any type over the roof from PCC block/GI pipe complete all as specified and directed.
34Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm long complete all as specified and directed
35Supply & fix single pointed air termination copper rod 12mm dia, 300 mm long complete all as specified and directed
36Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6 mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt all around earth plate, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4)type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate)40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh,and 40 mm dia GI medium grade earth lead protection pipe, complete all as specified and directed. (NOTE : Earth strip and its protection pipe upto and including 7.5 mtr are included under this item)
37Supply, installation & testing of Waterless and maintenance free Earthing (grounding) electrode of size Dia 85 mm x Length 3000 mm with 17.2 mmCubonded MS conductor in Pre cast in high purity electrically conductive granular (Marconite), having ultra low resistivity of 0.001 Ohm - m. (Provide the resistivity certificate for the same) Electrode made of electrically conductive granular mixed with cement to pre cast or backfill the voids surrounding the metal conductor in augured bore hole of 100 mm dia x 3000 mm depth, resulting in increase of effective surface area of the earth electrode. Electrode\"s top terminal should be sealed permanently with the conductive concrete and extension strip taken out be terminated at earth bus bar.Other hardware like nuts, bolts and washers should be of Stainless Steel.Electrode should withstand fault current up to 30 kA for 1 second.(Bidder Provide the certificate for the same )Note :-(i)Supplier of the Marconite Earthing Material should provide authorization letter from the Manufacturer for the Genuine material and also furnish certifications as per IEC 62516-7 & resistivity certificate confirming 0.001 ohm-m. Testing sample ofprecast marconite electrode to be submitted by the contractor for verification of the resistivity/conductivity value to the department prior to confirmation of orderto the vendor.(ii) In case of use of multiple electrodes interconnection between earth electrodes to be provided with Copper Bonded MS strip of size25mm x 6mm embedded in marconite concrete 70 Sqmm and connection from electrode/grid to equipment to be provided by copper cable 16 Sqmm single core cost of which is deemed to be included in quoted rates.
38M&L for bore earthing by digging bore 18 mtr to 20 mtr deep of 200 mm bore (minimum)providing in the bore GI pipe medium grade 40 mm bore (plugged at top with GI plug) copper strip 25 x 3 mm along the pipe upto equipment ( copper strip shall be fixed with the pipe by brass / SS nuts and bolts @ interval of 40 mm each in the entire depth of bore and copper strip 25 x 3 mm from each pit to equipment to be drawn in the GI pipe medium grade 40mm dia as protection of copper strip), in & including charcoal dust and salt filling in alternate layers (each layer shall be 15 cm thick) around the pipe /strip in the entire depth of the bore, PCC 1:2:4 type B1 pit covered with RCC 1:2:4 cover 50mm thick reinforced with XPM weighing 08 Kg/Sqm, CI frame excavation and earth work and other relevant work complete in all respect all as specified and directed by the Engr-in-Charge. Note :(i) For item No 36 to 38 , cost of making good of disturbed surface /area to match with existing surface is deemed to be included in the quoted rate.
39Supply & fixing in replacement 25 mm dia bore tubing, Light grade,galvanised, with all fitting,screwed,and fixed complete to walls/ceilings and laid in floors for earthing strip protection/ fixing of air terminator rod complete all as specified & directed.
40S&F in replacement of high quality copper bolts with nuts, washer to replace and repair existing earthing bolts of suitable length all as specified and directed.
41S&F in replacement of 50 mm medium grade PVC pipe ISI marked, burried earthing strip into the ground for proper insulation of building and equipment complete all as directed.
42M&L for Brazing of size 40mmx25mmx5mm in copper strip of size 25x3mm at the joint of strip through copper rod of proper size and combination of oxygen acetylene gas cylinder.Joint must be able to withstand high tensile strength and properly done without any defect or without any crack all as specified and directed.
43M&L for fabrication of earth pit indicator made of MS sheet of 3mm thick (shape as directed ) welded on iron strip of 32mm x 6mm thick x 900mm long (150mm in below GL) dully painted with synthetic enemeled paint over a one coat of redoxide primer complete with writing earthing nomenaclature as specifed by Engineer-in-charge.
44M&L for test point terminal block in replacement made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex.head screw complete all as specified and directed by Engineer-in-Charge.
45Dismantling of old PCC block for construction of new earth PCC block for air termination rod of size as indicated and directed by Engineer-in-charge in (1:3:6) type C1 all as specified and directed.

AI Tender Summary

OUR REF NO 40279618
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 39 Lakhs
LAST DATE 08-11-2023
Authority
Authority Name Military Engineer Services
Work Description Special Rep For Replacement Old Deteriorated Earthing System At Certain Locations, Conversion Of 1-Phase Electric Supply To 3-Phase Supply In Omqs And Replacement Of Dbs In Smq Area At Afs Sarsawa Under Ge ( Af ) Sarsawa
Basic Detail
Tender No 8123/SAR-08/2023-24
Bidding Type Tender
Location
City sarsawa
State Uttar Pradesh
Key Dates
Publish Date 18 Oct 2023
Submission Date 08 Nov 2023
Open Date 15 Nov 2023
Finance
Tender Value 39 Lakhs
Tender Fee 500
EMD 78000
Exemption Not Available
Document List
32563300-aca6-4c47-b19d-40f40253c25d.html
BOQ_698574.xls
SAR-08.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 18, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 08, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 15, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

32563300-aca6-4c47-b19d-40f40253c25d.html

xls

BOQ_698574.xls

pdf

SAR-08.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender