| 1 | S & F UPVC pipes of dia 50 mm dia bore schedule 40, confirming to ASTM, fixed complete to walls, ceilings or in floors/ in trench etc., complete all as specified and directed Including taking out old u/s pipe line of following bore. |
| 2 | All as per item No. 01 here in before but 25 mm bore |
| 3 | All as per item No. 01 here in before but 20 mm bore |
| 4 | All as per item No. 01 here in before but 40 mm bore |
| 5 | All as per item No. 01 here in before but 75 mm bore |
| 6 | All as per item No. 01 here in before but 100 mm bore |
| 7 | Supply and fixing 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ballscrewed for iron pipe and fixed. (Minimum weight 15mm- 142gms/2 0mm-210gms./25mm-455gms/ 40mm- 690 gms) complete all as specified and directed. |
| 8 | S & F Bib taps, cast copper alloyof 15 mm bore diawith crutch orbutterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixedcomplete all as specified and directed. |
| 9 | Supply & fixing UPVC tank adptor for 20 mm dia complete all as specified and directed. |
| 10 | Supply & fixing UPVC ball Valve for 50 mm dia complete all as specified and directed. |
| 11 | Supply & fixing UPVC ball Valve for 20 mm dia complete all as specified and directed. |
| 12 | Supply & fixing UPVC ball Valve for 25 mm dia complete all as specified and directed. |
| 13 | Supply & fixing UPVC ball Valve for 75 mm dia complete all as specified and directed. |
| 14 | Supply & fixing UPVC ball Valve for 100 mm dia complete all as specified and directed. |
| 15 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 16 | Returning , filling in trenches, including spreading , levelling , watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 17 | Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 18 | Material and labour for boring of holes upto 100 mm dia under road, pavement, hard standing by trenchless technology using ultra sound techinque and necessary machine complete all as specified and as directed. |
| 19 | M & L for construciton of valve chamber of size 60 x 60 x 90 cm size internal size including earth work, PCC foundation 1:4:8 of thickness 15cm under masonry in cement mortar 1:4 complete with MS angle Iron frame 40mm x 6 mm and MS cover 3.0mm thick with hinges and lockingarrangements and holdfast including plastering of internal wall surfaces with cement mortar of 1:4 of thickness 10mm and coping on top of brick masonry with PCC 1:4 and 20 mm grade stone aggregate with thickness 7.5cm including painting of steel surfaces with two coats of black synthetic enamle paint over a coat of red oxide complete all as specified and as directed. |
| 20 | All as per item No 19 here in before but 45 x 45 x 75 cm size |
| 21 | M & L for branch connection Cutting cast iron pipes and reducing to required length before laying in position for insertion of new tees, branches, etc complete all as specified and directed by Engr In Charge. |
| 22 | Supply, installation, testing and commissioning of GI pop-up sprinklers of HT 40 G Q = 900 litres/ Hour, PD = 18000 litres/ Hour, 2 nozzle operate one time, 5mm preciption one hour operation time as per design and drawing with connected accessories complete all as specified and directed as per data sheet. |
| 23 | Supply, installation (by taking out and carefully lowering in position) commissioning and testing of multistage submersible pumping set minimum 12 Stage, Minmium LPM 650, Minmium head 170 mtr pump set with electric motor 3 phase 440 volts 50 HZ frequency of delivery 80 mm dia suitable for borewell 200 mm (8\"\") dia complete all as specified and directed. |
| 24 | S&F in repair flat 3 core copper conductor PVC insulated and PVC sheathed cable 1100 volts grade of size 16 Sqmm all as required at site and complete all as specified and directed by Engr in charge. |
| 25 | S&F in repair flat 3 core copper conductor PVC insulated and PVC sheathed cable 1100 volts grade of size 25 Sqmm all as required at site and complete all as specified and directed by Engr in charge. |
| 26 | Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage capacity of 80 Ltrs and nominal cooling capacity of 40 ltr per hour complete all as specified and directed. |
| 27 | Supply, installation,commis-sioning of Water cooler fully stainless steel, electric driven single phasehaving approx storage capacity of 150 Ltrs and nominal cooling capacity of 120 ltr per hour complete all as specified and directed. |
| 28 | Supply and fix refrigerator, electric driven (single phase), capacity 195 Litres BEE 5 star rated complete all as specified and directed. |
| 29 | Supply and fix refrigerator, double door type electric driven (single phase), capacity 320 Litres BEE 5 star rated complete all as specified and directed. |
| 30 | Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size) Plastic/PVC Body as sample approved by GE complete all as specified and directed. |
| 31 | Supply, install, commissioning & testing of Monoblock pump set electric driven 3 phase 415 volt 50 Hz capacity 5 HP with starter of suitable rating complete including all necessary electrical connection complete all as specified and directed. |
| 32 | Cleaning of mud inside bore of 200 mm dia through pressure machine on hired basis from local market as per direction of Engineer in charge. |
| 33 | Supply and fixing UPVC column pipes both ends threaded of 80 mm bore dia heavy duty (each pipe of 3 meters) long as per site requirement complete all as specified and as directed including Upvc column pipe assecssories complete as per site requirement. |
| 34 | Supply and fixing sewage cutter pump set5.5 HP complete all as specified and as directed.Make : Kirloskar Brother Model ETERNA-400CWC or equivalent as approved by GE. |
| 35 | S&F in repair flat 3 core copper conductor PVC insulated and PVC sheathed cable 1100 volts grade of size6 Sqmm all as required at site and complete all as specified and directed by Engr in charge. |
| 36 | Supply, layingconnecting and testing for 100 mm sizes of DI (Ductile Iron) pipes class LA spigot and socket end pipe class K-7 suitable for and including rubber gasket joints in standard working length conforming to IS-8329 lain in trenches complete all as specified and as directed. Note :- (i)DI/CI special fittings shall be measured and paid separately under relevant items.(ii) Excavation and earth work shall be measured and paid separately under relevant items. |
| 37 | Supply and fix Valves, Sluice, flanged of class 1.6 PN 100 mm dia bore complete all as specified and as directed. |
| 38 | S & F star delta starter pannel board with encloser suitable for multistage submersible pumping setminimum 12 Stage, Minmium LPM 650, Minmiumhead 170 mtr pump set with electric motor 3 phase 440 volts 50 HZ frequency complete all as specified and as directed. |
| 39 | M & L for construciton of valve chamber of size 120 x 120 x 120 cm size internal size including earth work, PCC foundation 1:4:8 of thickness 15cm under masonry in cement mortar 1:4 complete with MS angle Iron frame 40mm x 6 mm and MS cover 3.0mm thick with hinges and lockingarrangements and holdfast including plastering of internal wall surfaces with cement mortar of 1:4 of thickness 10mm and coping on top of brick masonry with PCC 1:4 and 20 mm grade stone aggregate with thickness 7.5cm including painting of steel surfaces with two coats of black synthetic enamle paint over a coat of red oxide complete all as specified and as directed. |
| 40 | S & F in repair Non Return valve, flanged of class PN 1.6 supplied and installed of the 100 mm dia complete all as specified and as directed. |
| 41 | M&L for Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 10.0 sq mm 4 core complete all as specified and as directed. |
| 42 | S&F looping box (enclosures) of size 280 x 170 x 130 mm made of PVC comprising of 02 Nos aluminium bus bar 100 Amps rating fixed on porcelain insulators, earthing terminal and one MCB SP 6/16 Amp including MS bracket, nut and bolts complete all as specified and directed. |
| 43 | Supply and fixing LED flood light 210 watt 230 V AC outdoor type with lumen efficiency not less than 110 lumen/watt power factor not less than 0.85, CRI not less than 80 with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 44 | S&F rotating/adjustable type bracket forming of GI channel suitable for mounting of 02 nos LED flood light 210 watt capacity on existing pole complete all as specified and as directed. |
| 45 | S&F in replacement PVC wire 1.5 sqmm 3 Core PVC insulated cable copper drawn through PVC conduit from looping box to street light fitting terminal complete all as specified and as directed. |
| 46 | S & F in replacement of LED post top (Smart G-3 type) with decorative circular design compiant to dark sky norms with polycarbonate opaldiffuser and IP 65/IK-10 protection installed with suitable dia and5 to 7 feet length powder coated metal pipe complete with all fixing arrangement complete all as specified and as directed. |
| 47 | Supply, install,commissioning and testing Invertor type 5 star rated (MIN EER-3.2) air cooled split unit air conditioner electric driven single phase of capacity of 1.5 TR, Eco friendly refrigerant, hi wall split units indoor/outdoor unit complete with cordless remote control unit andauto restart facility, 100 % copper and stabilizer free operation, includingexcess copper tubing if required beyond the length supplied with AC unit and PVC conduit of 15mm dia not exceeding 2.5 mtr long for water drain and making good to disturbed surface with cement mortar ratio of 1:3 and testing complete all as specified and directed by Engineer-in-charge.Note:- (i) Rate quoted for items includes cost of all civil work like cutting to wall ceiling, floor, filling with PCC,finishing the surfaces with existing to match etc, if required for installation of AC unit as directed. (ii) Required copper pipes for installtion shall be deemed to be included in the quoted rates |
| 48 | All as per item No 47 here in before but capacity 1.0 TR |
| 49 | M&L for concealed sub main wiring of two run with 4.0 Sqmm single core PVC insulated, FRflexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit and accessories of suitable size and fixed on concealed surface of wall/ceiling with cutting chases where required including one run of 4.0Sqmm single core PVC insulated, FR,flexible copper cable as earth continuity conductor in green color complete all as specified and as directed. |
| 50 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed. |
| 51 | Supply, install ,testing and commissioning ofsingle Phase 230-240volts, 50 Hz, evaporator type water cooled Industrial Air Cooler of cooling capacity area 1000-1500 Sq.ft with 24 inches turbo axial fan having capacity of 1450 RPM and water tank capacity 35 Ltr, discharge of air flow Top/down as per site requirement, capcity of air flow shall be 18000 CMH including ducting as per site and requirement all as per the directions Engr- in-charge. |
| 52 | Supplying and layingXLPE insulated, PVC sheathed, armoured, heavy duty, aluminium conductor LT, 1100 Volts gradeof size 25 sqmm 3.5 core complete all as specified and as directed. |
| 53 | Supply and laying of DWC HDPE pipe of 38 mm inner dia SN4 category conforming to IS 14930 part I and II including accessories complete all as specified and as directed. |