Public Works Department-PWD has published Tender For Providing Internal And External Electrification To The Taluk Officebuilding At Tindivanam In Villupuram District.. Submission Date for this Tender is 27-10-2023. Electrification Work Tenders in tindivanam Tamil Nadu. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End |
2 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End |
3 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End |
4 | Supply and fixing of Battern holder (bakelite) with 9W LED bulb for BH point. |
5 | Supply and fixing of single box type 4" 18 W LEDfitting complete with TW round blocks on wall or ceiling with 18 W LED tube light with single side connection ( Havells / equivalant)with PVC unsheathed Copper leads from terminals to the fitting. |
6 | Supply and fixing of single box type 4" 18 W LEDfitting complete with TW round blocks with conduit pipe suspension from the ceiling with 18 W LED tube light with single side connection ( Havells / equivalant)with PVC unsheathed Copper leads from terminals to the fitting. |
7 | Supply and fixing of Aesthetically desined ultra modern 42 W 2" x 2" Surface Mounting luminaire with high brightness LED fitting (Havells / Equivalent ) on wall or ceiling, with PVC unsheathed leads from terminals to the fitting. |
8 | Supply and fixing of 42W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.(Make- Havells/Equivalent) |
9 | Supply and fixing of Aesthetically desined ultra modern24 W 1" x 1" High efficacy surface LED flat panel with high brightness LED for glare-free homogenous illumination. Also for POP ceilings LED fitting (Havells/ Equivalent ) on wall or ceiling, with PVC unsheathed leads from terminals to the fitting. |
10 | Supply and fixing of Aesthetically desined ultra modern 24 W 1" x 1" High efficacy Recess LED flat panel with high brightness LED for glare-free homogenous illumination. Also for POP ceilings LED fitting (Havells/ Equivalent ) on wall or ceiling, with PVC unsheathed leads from terminals to the fitting. |
11 | Supply and fixing of 18W LED Round type Recessed fitting with LED (Higher end) on false Ceiling from ceiling with PVC unsheathed copper leads from terminals to the fitting. |
12 | Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting. |
13 | Supply and fixing of 1200mm (48") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod with fan clamp with side plates and cross arm of size 450mm (18"). |
14 | Supply and fixing of 300 mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall. |
15 | Supply and fixing of louvers shutters arrangements for 300 mm (12") sweep (light duty)AC exhaust fan. |
16 | Supply and fixing of 3nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End. |
17 | Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End. |
18 | Supply and fixing of 20Amps DP Plug and Socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug) (Legrand / Hager make). |
19 | Supply and fixing of 40 A Rotary switch with 3 Nos Indicator combined with switch insutable sheet steel encloser on wall with earth connection only. |
20 | Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour. |
21 | Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour. |
22 | Supply and Run of 2 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour. |
23 | Supply and Run of 4 of 10 sq.mm. (140/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour. |
24 | Supply and Laying of 3 1/2 x 70 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. |
25 | Supply and clarnping of 3 1/2x 70 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. |
26 | Supply and fixing of brass cable gland for 3 1/2x 70sq.mm PVC armoured LTUG Cable with earth connection. |
27 | Supply and providing cable end termination of 3 1/2 x 70 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete. |
28 | Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End. |
29 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End. |
30 | Supply and fixing of Vertical type 8 way Triple pole and neutral MCB Double door Distribution board in sheet steel enclosure with metal door with IP42 protection with 1 No. of 100 A FP MCB Isolator as incoming and 4 No"s 63A TP MCB, 1 No 32A TP MCBand 9 Nos. of 6A to 32A SP MCB outgoing on wall with suitable angle iron framework with Cable entry box on top or bottom with earth connection only.The MCB DB and MCB"s should be with Legrand / Hager make only. |
31 | Supply and fixing of Vertical type 6 way Triple pole and neutral MCB Double door Distribution board in sheet steel enclosure with metal door with IP42 protection with 1 No. of 63 A FP MCB as incoming and 18 Nos. of 6A to 32A SP MCB outgoing on wall with suitable angle iron framework with Cable entry box on top or bottom with earth connection only.The MCB DB and MCB"s should be with Legrand / Hager make only. |
32 | Supply and fixng of TNEB meter board suitable for 3 phase 100A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 100A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete. |
33 | Supply and fixing of 32A DP MCB in flush with sheet enclosure in wall with earth connection[Legrand (MDS) / Hager (L&T) make] |
34 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class "B" GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. |
35 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection. |
36 | Supply erection, Testing and commissioning of 1.5 TR split type 3 star rated AC units fitted with hermetically sealed Air compressor with R22 refrigerant air cooled condenser, fan etc. and 1 No indoor Hi wall mounted 2.0 TR capacity evaporator unit complete with cooling coil, blower motor and connected accessories, control etcchord wire connecting indoor and outdoor unit with drain pipe suitable for operation on 230V + 10% 50Hz sinle phase AC supply.(Make - Carrier/ OGeneral/ Daikin/ Toshiba) |
37 | Supply and fixing of 4 KVA voltage stabilizer (V guard /Eq.make ) suitable for 2.0 tons capacity split type air conditioner with 3 minutes time delay and low / high voltage cut off switch (wall mounting) with necessary wire connection. |
38 | Supply and layingof 5/8"" and 3/8"" copper pipe (Extr beyond 3Mtrs supplied with AC Unit)(For split AC Unit) |
39 | Supply and Fixing of MS stand for fixing outdoor units.(SR- M-1991) (For Split outdoor unit) |
40 | Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of 1 no 13 persons capacity passenger lift as per the following specifications including taxes and duties. |
41 | 1.Location: Taluk Office Tindivanam |
42 | 2.No of lift: 1 No |
43 | 3.Type of lift: passenger |
44 | 4.Capacity of lift: 13 persons / 884 Kgs |
45 | 5.Speed: 1m / sec |
46 | 6.Type of drive: V3F drive with enhanced ride comfort and near zero level functions |
47 | 7.No of floors: GF + 2 Floor |
48 | 8.Total travel: 3.3 mts x 2 = 6.6 mts |
49 | 9.Leveling accuracy: high level accuracy with smooth and jerk free stopping |
50 | 10. Construction ofCAR: No 4 hardened sheethigh quality stainless steel car with hand rail granite flooring, Mirror and Perspex false ceiling. |
51 | 11. Position of machine: directly above the lift well. |
52 | 12. No of landing service: one in the front side-3 no’s |
53 | 13. No. of car entrance: one in the front side only |
54 | 14. Car entrance door: power operated automatic V3F drive center opening sliding SSdoor |
55 | 15. Landing entrance door: power operated V3F drive center opening sliding SS door with provision for emergency exit key at all landings. |
56 | 16.Lift wellSize : 2770 mm (wide) x 2200 mm (depth)as per ISI 14665(part1) 2000 |
57 | 17.Lift pit depth:1600 mm |
58 | 18. Car size:2000 mm (width)x1100 mm (depth) as per IS 14665 (part 1 )2000, |
59 | 19. Car clear opening: 900 mm wide x 2000 mm height as per IS 14665 (part 1)2000 |
60 | 20.Lift machine room size:4000 mm wide x 5000 mm depth as per ISI 14665 (part 1)2000 |
61 | 21. Power supply: 400 / 440 v three phase 50 Hz AC supply for power and 230 V 50 Hz single phase power supply for light. |
62 | 22.Control: micro computer (micro processor):based simplex collective control with / without attendant |
63 | 23. Car fittings: CFL lighting with 1 no 300 mm sweep cabin fan. |
64 | 24. Lift well: RCC construction with brick masonry to be constructed by PWD civil wing. |
65 | 25. Induction: UP / DOWN digital direction and position indicator for all landings and inside the car. |
66 | 26.Emergency alarm bell: battery operated bell to be provided with automatic charging device |
67 | 27.Emergency light: battery operated light to be provided with automatic charging device |
68 | 28.Fire mans switch: to be provided at the GF |
69 | 29. Minor builder works: to be provided by the lift contractor. |
70 | 30. Scaffoldings: to be provided by the lift contractor. |
71 | 31. Sill angles and fascia plates: SS to be provided by the lift contractor. |
72 | 32. Steel for lift machinery: to be provided by the lift contractor. |
73 | 33. Servicing and maintenance: free comprehensive servicing and maintenance for one year Guarantee period to be provided by the lift contractor. |
74 | 34. Automatic rescue device: to facilitate the landing of the nearest floor at the time of power failure this shall consist of suitable battery system with charger inverter under voltage protection system etc. complete with all accessories. |
75 | 35. Provision for intercom with phone: to be provided by the lift contractor. |
76 | 36.Lift license: preparation of drawings payment of charges to CEIG and insurance policy if any and obtaining CEIG approval for the lift as per lift act should be done by the lift contractor |
77 | 37. Floor position announcer: to be provided by the lift contractor. |
78 | 38.Special features |
79 | a) Infra red door sensor with full height screen |
80 | b) Full width half height rear panel mirror |
81 | c)TubularSShand rail in car |
82 | d) Stainless steel signal features |
83 | e) Vandal proof SS button with SS cover |
84 | f) SS door frames for landing doors |
85 | g) V3F door operator |
86 | h) Call register signal |
87 | i) Stainless steel fascia plates for car operating panel and landing fixtures |
88 | j) Steel ladder for lift machine room |
89 | k) On / off switch for fan and light |
90 | l) Over load warning indicator with audio announcer |
91 | m)Voltage stabilizer for control circuits |
92 | n)Braille button |
93 | o) Granite flooring provided by the lift contractor |
94 | 39.Over speed governor phase failure and phase reversal relay alarm bell T guide brackets for car and counter weight rubber padding under the winding unit motor of adequate capacity signal reduction worm gear electromagnetic brake with compression springs car safety gears buffers electro mechanical locks emergency key side supporting angles motor over load protection devices final limit switch main suspension ropes counter weight lifting joist for mounting the machineries. All the features as per differently abled persons actshould be provided. 2 Hrs fire retardent landing doors. |
95 | 40. Guarantee: guarantee at least for one year for the material and workman ship of equipments should be offered by the lift contractor. |
96 | 41. Site testing in accordance with IS 14665 should be carried out at the time of handing over to the user department |
97 | 42. Supply operation and maintenance manual and necessary tools for operation and a set of |
98 | Spare parts required for one year. |
99 | GST @ 18% |