Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Labour Charges for Boring and installing cast insitu bored piles resting on hard strata with N value morethan 100 (using DMC method) of size 450mm diameter, including necessary reinforcement as given in drawing, of basic length 17mts measured from under side of pile cap to the tip of pile shoe by adopting M25 grade and reinforcement as in drawing and 8mm diameter stirrups at a spacing of 200mm c/c. However, payment will be made on the basis of work done.The work includes dewatering,Bentonite slurry process,pile muck removal,casing for stabilization of pile bore,flushing of pile bore,welding of reinforcement if necessary,Slush removal,cleaning and the protection of surface water. |
| 2 | For piling works |
| 3 | Compound wall |
| 4 | ProvidingandlayinginpositionStandardisedConcrete Mix M-30 Gradeinaccordancewith IS456 -2000 using 20mmanddowngradedhardbrokengranitestonejelly for all RCC items of works with minimum cement content of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommendedproportionsasperIS9103toaccelerate, relatedsettingofconcrete,improveworkabilitywithout impairing strength and durability with about (5.0cum), 7730Kgof20mmmachinecrushedstonejellyandwith about (3.3 cum), 5156kg of 10 - 12mmmachine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centeringandshutteringbut includinglaying, vibratingwithmechanicalvibrators,finishing,curing,etc andprovidingfixtureslikefanclampsintheRCCfloor/ roof slabs wherever necessary without claiming extra cost etc.,completecomplyingwithstandardspecificationand as directed by the department and plants required including all other incidental charges etc., complete using CMPclause507ofMORTHRev-5specifications.p.no 65)l be made by the Department for the excess usage of materials) |
| 5 | For Piling works |
| 6 | For Main Building Area - COLUMNS - M30 Grade |
| 7 | GROUND FLOOR - M30 Grade |
| 8 | FIRST FLOOR - M30 Grade |
| 9 | SECOND FLOOR - M30 Grade |
| 10 | TERRACE - M30 |
| 11 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum |
| 12 | For pile cap |
| 13 | Kerb wall |
| 14 | Supplying and providing Anti termite pre construction treatmentusingaldrinordieldrinorheptachlorasper relevant IS 6313 (part II) code including cost of all materials, labour, hire charges for T&P etc complete. |
| 15 | PlainCementConcrete1:4:8(onecementfourCrushed stonesand andeightaggregate)using40mmgauge hardbrokengranitestonejellyforfoundation including dewateringwherevernecessaryandlaidinlayersofnot morethan15cmthickwellrammed,consolidatedand curing etc. complete complying with standard specification. |
| 16 | Supplying and erecting steel centering including necessarysupports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals,plinthbeams,gradebeams,staircasesteps, etc.whichrequireonly nominalstruttingusingmildsteel sheetsofsize90cmx60cmand10BGstiffenedwith welded mild steel anglesofsize25mmx 25mmx3 mm forboarding,laidoversilveroak joistsofsize10cmx 6.5cm spacedat about 75cm centretocentreorat suitable intervals etc. complete in all floors complying with standardspecification.(Paymentforcenteringshallbe given after the concrete is laid) |
| 17 | For Pile works |
| 18 | Kerb wall |
| 19 | Beams andslab |
| 20 | Forplanesurfacessuchas rectangularorsquareRCC columns, sunshades, top and bottom slab of RCC boxing,etc. |
| 21 | Supplying, fabricating and placing in position Ribbed Tor Steel grills for all RCC works as per design given includingcostofsteelandG.I.bindingwireinallfloors etc. complete complying with standard specification. (Contractorhastomakehisownarrangementsforthesupply of steel and binding wire) |
| 22 | Supplyingandfillinginfoundationand basementwith conveyed earthinlayersofnotmorethan15cm thickwell rammed watered and compacted etc., complete complying with standard specification. |
| 23 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 24 | Supplying and fixing in position C.I.Manhole covers (light or heavy duty) of 60 X 60cm in size in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), of best approved quality and as per standard specifications etc.,complete. |
| 25 | Paving the floor with design Antiskid ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm inall floors overa baselayer ofcementmortar1:3 (one cementandthreesand)20mmthicklaidin-situand pointed with same coloured cement. Designed Colour Ceramic Tiles of size 305 x 305 x 6mm |
| 26 | ProvidingandlayinginpositionStandardisedConcrete Mix M-20Gradeinaccordancewith IS456 -2000 using 20mmanddowngradedhardbrokengranitestonejelly for all RCC items of works with minimum cement content of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommendedproportionsasperIS9103toaccelerate, relatedsettingofconcrete,improveworkabilitywithout impairing strength and durability with about (5.0cum), 7730Kgof20mmmachinecrushedstonejellyandwith about (3.3 cum), 5156kg of 10 - 12mmmachine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centeringandshutteringbut includinglaying, vibratingwithmechanicalvibrators,finishing,curing,etc andprovidingfixtureslikefanclampsintheRCCfloor/ roof slabs wherever necessary without claiming extra cost etc.,completecomplyingwithstandardspecificationand as directed by the department and plants required including all other incidental charges etc., complete using CMPclause507ofMORTHRev-5specifications.p.no 65)l be made by the Department for the excess usage of materials) - Pile and Plinth Beam concrete |
| 27 | ProvidingandlayinginpositionStandardisedConcrete Mix M-25 Gradeinaccordancewith IS456 -2000 using 20mmanddowngradedhardbrokengranitestonejelly for all RCC items of works with minimum cement content of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommendedproportionsasperIS9103toaccelerate, relatedsettingofconcrete,improveworkabilitywithout impairing strength and durability with about (5.0cum), 7730Kgof20mmmachinecrushedstonejellyandwith about (3.3 cum), 5156kg of 10 - 12mmmachine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centeringandshutteringbut includinglaying, vibratingwithmechanicalvibrators,finishing,curing,etc andprovidingfixtureslikefanclampsintheRCCfloor/ roof slabs wherever necessary without claiming extra cost etc.,completecomplyingwithstandardspecificationand as directed by the department and plants required including all other incidental charges etc., complete using CMPclause507ofMORTHRev-5specifications.p.no 65)l be made by the Department for the excess usage of materials) |
| 28 | FOUNDATION AND BASEMENT - M25 Grade |
| 29 | GROUND FLOOR - M25 Grade |
| 30 | FIRST FLOOR - M25 Grade |
| 31 | SECOND FLOOR - M25 Grade |
| 32 | HEADROOM - M25 Grade |
| 33 | BrickworkinCM1:5(onecement&fivesand)usingII class ground moulded country bricks of size 8.75\"X41/4\"\"x 2 3/4\" includingfinishing,curing,etc.,complete complying with standard specification. (In Cement Mortar 1:5) |
| 34 | FOR GROUND FLOOR |
| 35 | FOR FIRST FLOOR |
| 36 | FOR SECOND FLOOR |
| 37 | FOR TERRACE FLOOR |
| 38 | Brick Partition Walls using II class ground moulded chamber bricks of size 9\"X43/8\"X 23/4\"in C.M 1:3using hoop iron reinforcement, if found necessary standard specification including finishing, curing, etc., complete complying with standard specification |
| 39 | Special Ceiling Plastering with cement mortar 1:3,12 mm thickinallfloorsincludingcostandconveyanceofall materialstositeand labourcharges etc, completeasper standard specifications (S.I.306) |
| 40 | Plastering with Cement Mortar 1:5 (One cement and Five Crushedstonesand),12mmthickinallfloorsincluding curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 41 | Paving the floor with best quality Vertified Tiles of size 600 x 600 x 8mmof approved colour, shade and quality laid in cement mortar 1:3 (one cement and three crushed stone sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 42 | Dadooing walls withGlazed tiles of sizes 305mm X200mmX 6mmsize of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two sand) over 10 mm base layer plastering and pointing with white cement neatly as directed. Glazed tiles of size 305X200X6 mm |
| 43 | UPVC WindowSpecification:SupplyingandfixingUPVC(Un-Plasticized PolyvinylChloride)Windowsofcasementtype(open) fromtheprofilethesizeofouterframe60mmx58mm and shutter profile are reinforcement with GI/1mm 125GSMand100%corrosionfree,theprofilesaremulti chamberedsectionswithwallthickof2mm.TheEPDM rubber(blackcolour)coveredwithoveralltheedgesof frame and shutter the shutter will be provided with Espag multipowerpointlocksandalsoitoperatesashandle. Thecornersandjointsshouldbeweldedandcleaned. Radiationsfreepinheadedplainorbrowncolourglass 4mm thick should be provided to the shutter and it should notallowleakageofwaterevenatmostrangingstorms andshouldhavekeylockableaction,securityprotective hinges, strong locking systems and as per size for arrestingnoiseandenergyloss.Theconnecting mechanismbetweensashandouterframethatenables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all roundtheframes.Thewindowshouldbegotapproved fromtheExecutiveEngineerbeforeuseonwork(pwd sor p.no 65) Page No :070 - M0674 |
| 44 | Pre-Painted Galvanized Iron Fixed Louvered Ventilators with Glass and Grill: Providing and fixing louvered ventilator fabricated from roll formed sections made of galvanized steel colour coated / powder coated (Base steel as per IS 513 \"D\" quality, galvanized as per IS 277 with zinc of 120 grams / sqm.) with total coated thickness of 0.58mm. Paint specification: Coated sections should be with primer coat of epoxy primer of 5-7 microns thick, finishpainted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns. Dimensions of sections: The section for external frame should be of 57mm x 33mm. Fixing details: The section should be cut to length, joined with profile to profile component. Accessories: Glass holding flanges made of glass filled nylon. Glass: Louvers should be provided with 4mm pinhead glass. Grill: Ventilator should be provided with grill made of 10mm Square MS bars to 12mm x 5mm flat at 4\" intervals. Total grill unit should be powder coated and fixed to ventilator frame with screws. The above frames should be fixed to brick / concrete masonry walls and floor by means of self-expanding screws. SOR 23-24, M-0668 |
| 45 | Supply and fixing of PVC Solid Doors using 19gauge 19mm MS Sq,tubes for styles and frames, 15mm MS Sq. Tubes for to, Lock and bottom rails. The Steel Tubes shall be covered with 5mm thick Solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in positionincluding furniture andfittings. The over all size of styles shall be 50mm X 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm X 30mm. The over all size of frames shall be 50mm X 45mm with suitable tabate for housing the shutter etc, complete as per standard specification. (pwd sor p.no :43)a) Solid panel PVC with door frame |
| 46 | ROLLING SHUTTERS (WITH ISI MONOGRAM)Supplyinganderectingpullandpushtyperollingshutter with I.S.I make of approved size and section using 18 G.I sheet.Theshuttershallbepaintedwithonecoatofred oxideprimerandtherateisinclusiveofHoodcovers, transportation charges etc(GEAR operated type from 8sq.m. to 12 sq.m area)PWD SOR 2021-2022 PAGE NO.49 & S I 0401 |
| 47 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 48 | Supply,delivery and fixing of SFRC cover slab including labour cost, cost and conveyances of all materials, etc., complete |
| 49 | PaintingtwocoatswithReadyMixedEnamelPaintover the new iron works of approved quality and colour without priming coat including the cost of all materials etc., complete, in all floors. |
| 50 | Supply andfixingofM.SGrillswithDoorsandWindows with one coat of Red oxide with Primer including all costs suchaswelding, grindingandfabricationcharges,cost andconveyanceofallmaterialstositeetc, completeas per standard specification. |
| 51 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slakedlime(nosandtobeadded)overroofslab, the proportionofbrickjellytolimebeing\"32to12.5well beated with wooden beaters for giving required slope and thicknessasdirectedbythedepartmentalofficersetc., complete.-10 cum |
| 52 | Finishingthetopofroofwithonecourseofmachine pressedtilesofsize200mmx200mmx20mmof approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2%by weightof cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete |
| 53 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification |
| 54 | Fabricating supplying and fixing of roof with Poly carbonate sheet of 6mm thcik with any colour or any other approved design and to be fixed with shelf tapping screws, plastic washer. The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets. The sheet to be fixed with making suitable corrugated, cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers. |
| 55 | Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights. The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc. The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147. Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) Armstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of Dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental office |
| 56 | Manufacturing,SupplyingandFixingofStainlessSteel Handrailsforstaircaseusing50mmdia304LGrade Stainless Steel pipe of 1.60mm thick at required locations toaheightof900mmfromfinishedfloorlevelweldedto 38mmdiaStainlessSteelpipepostof1.00mmthickas vertical at 900mm centre with 2 Nos. of 25mm dia intermediatehorizontalstainlesssteelpipeof1.60mm thick in between. The vertical pipe has to be welded to the 100X100X6mmMSbaseplateencasedinthebase concrete.The rate isinclusive ofthe chargesfor cutting, bending, welding, grinding, polishing, conveyance, electrical charges,etc.complete(PWDSOR2021-2022, P. No 62, S.I 0651) |
| 57 | Supplying and laying in flooring/staircase floringwith fully polished Synthetic Grey colour Granite stone of 20mm thick (average) of 4\" X 2\" in size laid over base layer of cementmortar 1:3 (one cement and three Plastering sand) - 20 mm thick and applying cement slurry &pointed with white cement and colour pigments to the colour of stones and polished neatly as directed by the deparmental officers (Paving the floor with best approved quality for Staircase & for Landscape coping) data 23-24 |
| 58 | Finishing the top of floor with Granolithic Finish with CC 1: 2: 4 (one cement, two sand & four HBG jelly) using chips ofgrade10mmand below for 25mm thickness and rubbed smooth etc, complete as per standard specification |
| 59 | Flooring/Top of the slab with Cuddapah slabs of 40mm thick over a base mortar in CM 1:3 (One Cement and Three Plastering Sand (P - Sand))20 mm thick and pointed with cement mortar 1:3 ( one cement and three Plastering sand)usimg Black oxide complying with standard specification(P & D data 53) |
| 60 | Supplying and laying Rubberised interlocking Paver blockM40 grade Providing and laying of83mmthick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with sand cushion below the uniform shap of approvednon skitting surface in the top and the rate including levelling the base preparation ofpavers as sub base, sand cushion 150mm thick layingout of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,. |
| 61 | Supply and fixing 16amps DP switch with metal clad (side handle) of 240 V with Fuse & Neutral link on suitable teak wood Board of size 30cmx20cmx6 cm including necessary internal conection,earth connection etc., complete SD 142 |
| 62 | Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB as outgoing on suitable angle iron frame on wall with earth connection only. Lower End SD 620 |
| 63 | Supply and fixing of 6 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63 A 4 P MCB switch as incoming and 18 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Lower End SD 627 |
| 64 | Metering Panel Type ISupply and fixing of 8 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board (with MCCB incomer) with double door (metal) with 1 no.250A 4P MCCB switch as incoming and 7 nos.63A 3P MCB , 3 nos. 6A to 32A SP MCB as outgoing with suitable cable end box in flush with wall with earth connection only. Higher End SD 704 |
| 65 | Metering Panel Type IISupply and fixing of 8 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board (with MCCB incomer) with double door (metal door) with 1 no. 160A 4P MCCB switch as incoming and 6 nos. 63A 3P MCB, 6 nos. 6A to 32A SP MCB as outgoing with suitable cable end box in flush with wall with earth connection only. Higher End SD 703 |
| 66 | Supplying and fixing of 5 A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet including cost of wall socket, switch and labour charges of wall cutting, grouting, flushing and making good, painting with primary and finishing coat for MS box etc., complete as directed by the departmental officers. (SD 135) |
| 67 | Supplying and fixing of 5 A /15A 3 pinflush type wall socket with15A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet including cost of wall socket, switch and labour charges of wall cutting, grouting, flushing and making good, painting with primary and finishing coat for MS box etc., complete as directed by the departmental officers. (SD 138) |
| 68 | Supply and fixing of 20 Amp DP Plug and socket in sheet enclosure with 20A DP MCB in flush with wall with earth connection (For A.C Plug) (Legrand (MDS/Hager (L & T make) SD 140 |
| 69 | Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wallincluding thecost ofcable, PVCpipe andspecials, ceiling rose, flush type 5amsSP markswitch,PVC junction box, 16gauge MS switch box 300mm x 200mm x 75mm covered by laminated hylem sheet 3mmthick, cement, labour and making good of concealed portion with suitable colour for concealed PVC Fan point and Wiring for Light point / ceiling fan point with regulator - Shops and corridor derived from SD 25 |
| 70 | Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour. SD 413 |
| 71 | Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.. SD 429 |
| 72 | Supply and laying of 2 x 6 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good (203 Nos with compression gland) SD 197 |
| 73 | Supply and laying of3 1/2 core 25 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth tomake goodSD 204 |
| 74 | Supply and laying of 4 core 16 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good SD 203 |
| 75 | Supply and laying of 2 core 10 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good SD |
| 76 | Supply and laying of 4 core 10 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good SD 202 |
| 77 | Supply and fixing of brass cable gland for 2 x 6 sq.mm. PVC LTUG armoured cable with earth connection including cost and conveyances of all materials and labour cost, etc., complete SD 181 |
| 78 | Supply and fixing of brass cable gland for 3 1/2 x 50 sq.mm. PVC LTUG armoured cable with earth connection including cost and conveyances of all materials and labour cost, etc., complete SD 188 |
| 79 | Supply and fixing of brass cable gland for 23 1/2 x 70 sq.mm. PVC LTUG armoured cable with earth connection including cost and conveyances of all materials and labour cost, etc., complete SD 181 |
| 80 | Supply and fixing of brass cable gland for 4 x 10 sq.mm. PVC LTUG armoured cable with earth connection including cost and conveyances of all materials and labour cost, etc., complete SD |
| 81 | Earthing as per PWD standard with an earth electrode of 2 metre Class \"B\" GI pipe of dia not less than 32mm complete with necessary masonry work GI Pipe Earth electrode - SD 234 |
| 82 | Supplying and run off 14 SWG GI wire on walls or below ground level with necessary \"U\" nails, earth work excavation and refilling & including the cost of all materials etc., complete in all respects as directed by the departmental officers. SD 74 |
| 83 | Supply and fixing of 25x6 GI Earth Strip on walls or below ground level with necessary \"U\" nails, earth work excavation and refilling & including the cost of all materials etc., complete in all respects as directed by the departmental officers. Sd 75 |
| 84 | supply and fixing of 18W LED square type Recessed fitting with LED (Lower end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.SD 529 |
| 85 | Supply and fixing of WT bulk head fitting with guard suitable for 11W CFL lamp with CFL SD 83 |
| 86 | Supply and fixing of20W LED Tube Light fitting SD 87 |
| 87 | supply and fixing of 65 mm dia. (2 -1/2\") GI pipe (class B) of 3 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 30W LED street light fitting with LED (Lower end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour . Derived from SD 542 |
| 88 | Supply and installation of wall mounted 18 inch exhaust fan for toilets - SD 119 |
| 89 | Supply and installation of Floor mounted 100WLED Flood light with driver M-1300 |
| 90 | Supply and installation of 150 x 50 mm GI cable tray with supports M-1644 |
| 91 | Supply and installation of 300 x 50 mm GI cable tray with supports M-1645 |
| 92 | InvestigationchargesforGeophysicalsurveryfindingof yeild to the point drilling of Borewell for all etc., complete |
| 93 | Drillingofborewellsofsize6\"to8\"dia.insedimentary formation using hand boreset including insertion ofcasing pipeetc.,andsupplyingandpackingofpebbles (Conveyanceofhandboresetincludingloading andunloading to be done by the contractor) (twad sor P.no : 305) TWAD |
| 94 | Supply and delivery of clear water vertical wet type submersible pump suitable for 100mm dia borewell/UG sump conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 and as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % |
| 95 | 5.0 HP Submersible Pump with panel board & Labour Charge |
| 96 | 3.0 HP Submersible Pump with panel board & Labour Charge |
| 97 | 2.0 HP Submersible Pump with panel board & Labour Charge |
| 98 | Labour Charges for the erection of Submersible pumpset in borewellincluding fixing and jointing submersible cable with proper clamps upto the starter to required depth and alsofixingofriserpipestotherequireddepthvalves erectionclamps, anderectionofpanelboardconsisting of TPICN swtiches starter voltmetre, Ammeter, three point (indicating) lamps capacitor single phasing preventor and layingandjointingthecableandtwinearthingforetc., Completeandtestingthepumpsetandtrailrunfor10 days. (TWAD SOR P.NO : 287) UPTO 5 HP |
| 99 | SupplyandDeliveryof 150mmdiaPVC casingPipes includingcostandconveyanceofmaterialsandlabour charges etc. complete as per standard. Specifications |
| 100 | Supply and delivery of 3 phase panel boardstar delta with two level guard and auto start to suitable for 5 HP submersible pumpset etc. complete (TWD SOR P.NO :110) |
| 101 | Supplyingdelivery of G.Iand PVC Pipes and specials of approved quality and best varity of B Class pipe including cost convayence of materials to work siteetc., complete. |
| 102 | Borewell 8 Module Cover Plate (twad sor p.no : 182) |
| 103 | 40mm Dia PVCpipe (PWD SOR P.NO 99) |
| 104 | 40 mm Dia PVC Coupling (PWD SOR P.NO 99) |
| 105 | 40 mm Dia PVC Elbow (PWD SOR P.NO 100) |
| 106 | 40 mm Dia PVC Bend (PWD SOR P.NO 100) |
| 107 | 40 mm Dia PVC Reducer 50 x 40 mm (PWD SOR P.NO 100) |
| 108 | SupplyingandfixinginpositionbestapprovedofBIS quality PVC rain water down fall pipes having a pressure of4kg./sq.cmincludingcostofnecessryPVCshoe, PVCbend,castirongratingsofrequireddiameterand special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the R0.45 roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at thecentreofthepipelineinadditiontothoseformore than 3.0 metre pipe length, etc., complete complying with standard specification. |
| 109 | SupplyingandfixinginpositionbestapprovedofBIS quality Sanitary pipes having a pressure of6 kg./sq.cmincludingcostofnecessryPVCshoe, PVCbend,castirongratingsofrequireddiameterand special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the R0.45 roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at thecentreofthepipelineinadditiontothoseformore than 3.0 metre pipe length, etc., complete complying with standard specification. |
| 110 | Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of Crushed stone sandand five part of 40mmgauge brickjelly) and finishedwithCementMortar1:3(OneCement,Three Crushed stone sand ) including dismantling masonry workswhereverfoundnecessaryandmakinggoodthe dismantledportionstotheoriginalconditionandgiving connection to the CI / PVC pipes, etc., complete complyingwithstandardspecification.(TheNahaniTrap should be got approved by the Executive Engineer before use on works) - 75X50mm |
| 111 | Supplying and fixing in position 15mm dia brass CP screw downtap/Pillartap(heavyduty)ofapprovedmake conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works) - SD Tap |
| 112 | Supplying, laying and jointing PVC pipes (having working pressure10kg./sq.cm)ofapprovedqualityandbest varietyconformingtoBISofthefollowingdiaincluding cutting,threadingandfixingPVCspecialsusingPVC adhesives (but excluding cost of such specials) and fixing intowallwithteakwoodplugs,PVCclampsandscrews making holes on the wall (or) drilling holes in the roof and makinggoodthedismantledportiontooriginalcondition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffoldingcharges,etc.,completecomplyingwith standard specifications.The PVC pipes shall begot approved by Executive Engineer before use on works.(Internal Concealed Line) |
| 113 | 20mm dia |
| 114 | 25mm dia |
| 115 | 32 mm |
| 116 | Supplying, laying and jointing PVC pipes (having working pressure6kg./sq.cm)ofapprovedqualityandbest varietyconformingtoBISofthefollowingdiaincluding cutting,threadingandfixingPVCspecialsusingPVC adhesives (but excluding cost of such specials) and fixing intowallwithteakwoodplugs,PVCclampsandscrews making holes on the wall (or) drilling holes in the roof and makinggoodthedismantledportiontooriginalcondition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffoldingchargesupto4metreheightaboveground level,etc.,completecomplyingwithstandard specifications. ThePVCpipesshallbegotapprovedby Executive Engineer before use on works. |
| 117 | 110 mm dia |
| 118 | 75mm dia |
| 119 | SupplyingPVCSpecials(withworkingpressure6kg./ sq.cm.) in water supply arrangements (both in internal and external water supply arrangements (pwd sor p.no :102) |
| 120 | 75 mm Dia Elbow |
| 121 | 40 mm Dia Elbow |
| 122 | 32 mm Dia Elbow |
| 123 | 20 mm Dia Elbow |
| 124 | 75 mm Dia Tee |
| 125 | 40 mm Dia Tee |
| 126 | 32 mmDia Tee |
| 127 | Supplying and fixing in position Indian water closet of size580X440mm,whiteglazedearthenwareofapproved quality with \"P\" trap or \"S\" trap confirming to IS:2556 -Part XIIwithsandcushionandformingflooringalroundthe closetusing40mmbrokenbrickjellyinlimeconcrete 1:2:5 ( one part of lime, two parts of sand and five parts of brickjelly)100mmthickandfinishingthetoptorequired slopeandincludinggivingnecessaryconnectiontocast iron soil pipes/ PVC pipes by dismandling brickmasonry, reinforcedcementconcreteroof/floorslabandmaking goodthedisturbedportiontooriginalconditionwithout leakage etc., complete complying with standard specifications and as directed by the departmental officers. |
| 128 | Supplyingandfixinginpositionbestqualityapproved make white glazed earthenware wash hand basin of size 550 X 400 mm with a pair of cast iron brackets, including cost of 15mm diametre brass chromium plated piller tape,32 mm diametre C.P. Waste union, 32 mm diametre P.V.C.wastepipewithrubberplugandchain,15mm diametre G.M.wheel valve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teakwood plugsand screwsand givingnecessary water supplyconnectionandpaintiungthebracketswithtwo coatsofpaintoveraprimimgcoatofanticorrosivepaint includingtestingforleackageetc.,completecomplying with standard specifications |
| 129 | Providing rain water harvesting using 3 nos.of R0.45 well ringsof90cminnerdia(clear)with5cmwallthickness madeoutofcementconcrete1:2:4using20mmhard brokenjellytoaheightof30cmeachsupplyingand fabricating16nos.of6mmdiaMSrodverticallyand3 nos.of6mmdiaMSrodcircumferentiallytiedtogether with 18 guage binding wire for well rings including necessaryearthworkexcavation1mdiato adepthof 1m,supplyingandfilling40mmHBGinsidetheerected well ring to a depth of 90cm, and top covered with R0.45 circularperforatedcoverslabof1mdiaand5cmthick which inclusive of cost and fabrication of 6mm M.S reinforcementat15cmspacingsonbothdirectionsand one 6mm M.S rod ties at the edge of the slab circumferentially includingcostofmoulding,curing, finishingandwellplacinginpositionanddisposingoff excavated earth with all initial leads and lifts in places as shownbytheDepartmnealofficersetc.,completeinall respects. |
| 130 | supply, delivery and fixing of Gate Valve Fixing in Terrace level including cost and conveyance of all materials, labourcost, etc., complete |
| 131 | 40 mm dia |
| 132 | 32 mm dia |
| 133 | 25 mm Dia |
| 134 | supply, delivery and fixing of Vent Cowl Fixing including cost and conveyance of all materials, labourcost, etc., complete |
| 135 | 110 mm dia |
| 136 | 75 mm dia |
| 137 | Providing & fixingCuddapah Sinkincluding cost and conveyance of all materials, labourcost, etc., complete |
| 138 | Supply and delivery and fixing of HDPE tank of capacity 5000 liters as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc., |
| 139 | Supply andrunof2of4sqmm(56/0.30)PVC insulated SCunsheathedcu.conductorof1100Vgradein25mm diaGIpipe(Class\"B\")suitablybentatbothendswith necessary angle iron upright and end supports for main.SD 70 |
| 140 | Supply of Glazed stoneware gully trap of size 150 x 100 mm with 100 mm outlet, CI grating to suit the size of the gully mouth, CI cover & frame of 300 x 300 mm clear opening of 7 kg weight, complete. |
| 141 | Supply and fixingofapproved make Gate valves with SS / Bronze chromium plated balls suitable for threaded end connections. - P No:45 / TWAD |
| 142 | 32mm dia |
| 143 | 25 mm Dia |
| 144 | 20 mm Dia |
| 145 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) - 600X450 size |
| 146 | Supplying and Fixing Health Faucet in all toilets |
| 147 | Supplying and Fixing Pillar Cock in Wash Basin Top |
| 148 | Supplying and Fixing Chromium Plated Towel Rail - 60 cm long and 20 mm dia brackets |
| 149 | Supplying & Fixing Urinal in correct position |
| 150 | Providing & Fixing Urinal Partition |
| 151 | Supply, installation, testing and commissioning of Micro Processor based conventional 4 Zone Fire Alarm Control Panel having the rating of 24 volt DC power supply, consisting 230 / 24 volt SMPS unit, 2 Nos. of 12 volt 7 AH standby batteries, suitably mounted on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers.Pg 85- M0769 |
| 152 | Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers (Make: Ravel / Equivalent) Pg 86 - M0772 |
| 153 | Supply, installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. (Make: Apollo / Equivalent) Pg 85 M0770 |
| 154 | Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.Pg 86 M0773 |
| 155 | Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT M-0852 |
| 156 | Supply of Network Video Recorder (NVR) with recording storage for 30 days 16 Channel - 2 SATA (2 Nos. 6TB Hard Disk) M-2197 and M-2222 |
| 157 | Supply of 1080P Vandal-Resistant Network IR Bullet Camera, 1/3” inch CMOS , H.265/H.264 ,Lens 3 ~ 9mm (4.3x) varifocal lens, Edge based Analytices , WDR min 80dB or better , color 0.24Lx , B/W 0lx with Dynamic range 30Mtrs , Min 30fps@2M all resolutions (H.265/H.264), White balance , AES , Backlight compensation TVT 5MP IP MBLLET CAMERA HSN: 85258020 |
| 158 | SUPPLY DELIVERY AND FIXING OF TVT 8 PORT POE SWITCH M 2193 |
| 159 | SUPPLY DELIVERY FIXING AND INSTALLATION OF TCL 50 INCH TV (Q) |
| 160 | SUPPLY DELIVERY FIXING OF WALL MOUNT 6U RACK 500D M 2226 |
| 161 | CAMERA INSTALLATION K TESTING CONFIGUBRATION CHARGES (Q) |
| 162 | Supply and installation of 25 mm PVC Conduit M-1619 |
| 163 | supply, delivery and fixing of CAT 6 Armoured LAN & CCTV Cable M 2184 |
| 164 | Supply and installation of fiber optic cable 6 core outdoor for CCTV (POE to NVR) M-2189 |
| 165 | SUPPLY OF MICROTEK 1 KVA UPS WITH 150AH BATTERY Pg 158 M2100 |
| 166 | Supply,Installation and Commisioning of ETP Plant for treating Fish stall and Meat stalll waters of 10KLD capacity - ETP to remove DOD , COD , Oil grease , High organic matters , Possible high chloride content and considerable amount of blood , fat and hair. The treatment to include primary biological treatment followed by secondary treatment and tertiary treatment. The cost to include ultra filtering plant , ms frp tanks and also the approvals from PCB authority as per the required standards. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail