Tender For Provision Of Certain Sanctioned And Major Revenue Works At Af Station Sulur, sulur-Tamil Nadu

Military Engineer Services-MES has published Tender For Provision Of Certain Sanctioned And Major Revenue Works At Af Station Sulur. Submission Date for this Tender is 06-11-2023. Wrenches and Drivers Tenders in sulur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

40226152
Tender For Provision Of Certain Sanctioned And Major Revenue Works At Af Station Sulur
Open Tender
Indian
Tamil Nadu
sulur
06-11-2023

Tender Details

Tender For Provision Of Certain Sanctioned And Major Revenue Works At Af Station Sulur; 2 Surface Excavation N.Exc 30 Cm Deep And Averaging 15Cm Deep In Soft / Loose Soil Complete All As Specified And As Directed. 3 Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Laying Xlpe Cable Etc. N Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out Hard / Dense Soil Complete All As Specified And As Directed. 4 M&L Pcc ( 1:4:8 ) Type D-2 Using 40Mm Graded Stone Aggregate As In Foundations, Filling And Mass Concrete Complete All As Specified And As Directed. 5 M&L Reinforced Cement Concretetype B-0, 1:2:4 Using 12.5Mm Graded Stone Aggregate As In Beams, Cantilevers, Bressummers, Lintels Over 1.5M Span Complete All As Specified And As Directed. 6 M&L Formwork To Sides And Soffits Offloor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc To Provide Flat Rough Finished Concrete Surface Complete All As Specified And As Directed. 7 M&L Reinforced Cement Concrete Type B-0, 1:2:4 Using 12.5Mm Graded Stone Aggregate Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Etc Complete All As Specified And As Directed. 8 M&L Formwork To Soffits Of Suspendedslabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work; Not Exceeding 200Mm Thick ( Horizontal Or Sloping ) To Provide Flat Rough Finished Concrete Surface Complete All As Specified And As Directed. 9 M&L Formwork Toedges Of Concrete Flats, Treads, Breaks In Floors, Window Cills, Concrete Railings, Openings In Concrete Walls, Floor And Roofs N Exc 20 Cm Wide And Sides Of Rcc / Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exc 10Cm But N Exc 20Cm Wide To Provide Flat Rough Finished Concrete Surface Complete All As Specified And As Directed. 10 M&L Reinforced Cement Concrete Type B-0, 1:2:4 Using 12.5Mm Graded Stone Aggregate As In Chajjascomplete All As Specified And As Directed. 11 M&L Formwork To Chullah Hoods, Chajjas, Troughs And Similar Items Including Edges To Provide Flat Rough Finished Concrete Surface Complete All As Specified And As Directed. 12 S&F High Strength Corrosion Resistant Tmt Steel Bars Of Grade Fe–500Of 10Mm Dia And Over, Cut To Length, Bent To Shape Required Including Cranking, Bending, Spirally For Hooping, Hooking Ends And Binding With Annealed Mild Steel Wire Not Less Than 0.9Mm Dia Or Securing With Clips Or Welded Complete All As Specified And As Directed. 13 S&F High Strength Corrosion Resistant, Tmt Steel Bar Of Grade Fe-500, 5 Mm Dia And Above And Up To 10 Mm Dia Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With Mild Steel Wire ( Annealed ) Not Less Than 0.9 Mm Dia., Or Securing With Clips In Stirrups , Spacers And Binders Etccomplete All As Specified And As Directed. 14 M&L100 Mm Thick Pcc ( 1:4:8 ) Type-D-2 Using40 Mm Graded Stone Aggregate As In Sub Base Floors Complete All As Specified And As Directed. 15 M&L 25Mm Thick Cement Concrete Type B-1, 1:2:4 Using 20Mm Graded Stone Aggregate As In Floors Complete All As Specified And As Directed. 16 M & L Pre-Cast Cement Concrete Block Masonry With Solid Blocks, Type C-1, In Pcc 1:3:6 Using 20 Mm Graded Aggregate, Exc. 10 Cm In Width And Setting In Cement Mortar 1:6 Complete All As Specified And As Directed. 17 M&L Rendering 10Mm Thick On Brick Work Or Concrete Surfacesin Cementmortar 1:4 And Finishedeven And Smooth Without Using Extracement Complete All As Specified And As Directed. 18 M&L Preparation On Newly Plastered Wall Surfaces And Applying Two Coats Of Oil Bound Distemper Over The Wall Treated With 2Mm Thick Plaster Of Paris Putty And One Coat Of Alkali Resistant Primer Complete All As Specified And Directed. 19 M&L Rendering 15 Mm Thick Onbrick Or Concrete Wall Surfaces, In Cement Mortar 1:4 Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 20 M&L Preparation On Newly Plastered Wall Surfaces And Applying Two Coats Of Cement Base Paint One Coat Of Alkali Resistant Primer Complete All As Specified And Directed. 21 M&L 75Mm Thick, Plain Cement Concrete ( 1:3:6 ) , Type C-2 ( Using 40 Mm Graded Stone Aggregates ) , As In Plinth Protection / Path Including Making Joints At 3.00 Metre Intervals And At Each Corner, The Joint Shall Be Filled With Mastic Filling ( To Full Depth ) Comprising Of One Part Heated Hot Blown Bitumen 85 / 25 & Two Parts Heated Sand ( By Volume ) , Surface Finished Even And Smooth Without Using Extra Cement, Complete All As Specified And As Directed. 22 Note For Item No 21 :-The Concrete Shall Be Laid At A Stretch Not Exceeding 3 Metre In Length And Width Of Joint Shall Not Be More Than 12 Mm. 23 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm Complete All As Specified And As Directed. 24 Removing Excavated Material Exc. 1.50 Km But N Exc. 5 Km And Depositing Where Directed Complete All As Specified And As Directed. 25 M&L Framed Work Such As Grills, Gratings, Etc.. With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework Of Water Tanks And Similar Work Conforming To Fe.290.Gde-E-165 Complete All As Specified And As Directed. 26 M&L Preparation Of New Steel Surface Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over One Coat Of Red Oxide Primer Complete All As Specified And As Directed. 27 Note For Item No 26 :- ( A ) All Synthetic Enamel Paint, Shall Be Of 1St Quality Manufactured By The Standard Firms Of Make As Specified. 28 ( B ) The Contractor Shall Inform The Ge, Within Three Weeks Of The Acceptance Of The Tender, The Brand / Names Of The Manufacturers Of Paint Proposed To Be Used In The Works And Submit Samples Thereof And Obtain Prior Written Approval Of Ge Before Their Use In Works. 29 ( C ) The Contractor Shall When So Required By The Ge, Produce Certificate From The Manufacturer Or Their Representative To Establish That The Brands Of Paints Purchased By The Contractor From Them, Satisfy The Requirements Of The Relevant Indian Standards. Tint Of Paint, Will Be Approved By The Ge. 30 ( D ) Paints Shall Be Obtained Direct From Approved Manufacturer Or From Their Authorized Agents Only Of Respective Brands Mentioned Below And Brought To Site In Sealed Containers. The Paint So Procured Shall Be Of First Quality Of Any Approved Make As Per List Of Makes Specified. I. Berger Paints ( Luxol ) , Ii. Jenson & Nicholson ( Brolac ) , Iii. Shalimar Paints ( Superlac ) , Iv. Goodlass Nerolac ( Nerolac ) , V. Asian Paints ( Apcolite ) 31 ( E ) Unless Otherwise Specified The Tints Of Paint Shall Be As Approved By The Ge 32 ( F ) The Contractor Shall Submit Samples Of The Paints Proposed For The Work Along With Results Of Tests Conducted In Approved Laboratory As Directed By The Engineer-In-Charge For Approval. 33 ( G ) The Surface Shall Be Thoroughly Cleaned And Dusted. All Dirt Scales Oil And Grease Shall Be Thoroughly Removed Before Painting Is Started. The Prepared Surface Shall Be Inspected And Approved By The Ge Before Painting Is Commenced. The Weather Shall Not Be Foggy / Rainy, Dusty Or Windy. The Suitability Of The Weather Will Be Determined By The Engineer-In-Charge. 34 ( H ) No Hair Marks From The Brushor Clogging Of Paint Buddles Shall Be Left On The Work. Surface Shall Ordinarily Not Be Painted Until It Has Dried Up Completely. Trial Patches Of Paint Shall Be Laid At Intervals To Check If Drying Is Satisfactory. 35 ( E ) Unless Otherwise Specified The Tints Of Paint Shall Be As Approved By The Ge 36 ( F ) The Contractor Shall Submit Samples Of The Paints Proposed For The Work Along With Results Of Tests Conducted In Approved Laboratory As Directed By The Engineer-In-Charge For Approval. 37 S& F Steel Rolling Shutterswith Out Ball Bearing, Springas Per Specified Including Top Cover, Anchoring Rod, Hasp And Staple Withone Shop Coat Of Primerand Two Coats Of Synthetic Enamel Paint With Gear Operated Box ( Approved Quality ) Erected In Position And Making Good The Surface After Fixing Including Locking System Complete All As Specified And As Directed . 38 S&F Pre Painted Coloured Corrugated Galvalume Roofing System Sheet 0.50 Mm Thick Having Zinc Aluminum Alloy Coating Az150 Shall Be As Per Is:277 / Astm 1379 150 Gsm / Sqm Double Ribbed Trapezoidal Profile Steel Sheetany Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall Fixed With Self Tapping Screws Complete All As Specified Anddirected. 39 M&L Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mmthick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified Anddirected. 40 Note For Item No 38 & 39:- ( Pre-Painted Coloured Galvalume Roofing ) :- 41 ( I ) The ManufacturerS Test Certificate Andindividual Test Certificate For The Chemical And Mechanical Properties Of Sheet Must Be Submitted For Approval By The Concerned Authority Prior To Installation. 42 ( Ii ) The Contractor Shall Ensured That No Leakages Take Place From The Roof. The Roofing Shall Be Coloured Galvalume Roofing System ( Olive Green Colour Or As Approved By Ge ) With Feed Material Manufactured From 0.50 Mm Totalcoated Thickness ( Tct ) , Minimum 550 Mpa Yield Strength And Shall Conform To The Physical Specifications Of Is: 2062 Of 2011, Coated With Hot Dip Metallic Aluminium / Zinc Alloy Coating Az150 As 150 Gm / Sq.Mt Total On Both Sides. 43 ( Iii ) The Painting Shall Be Coloured Baked Enamel Polyesterwith Silicon Coatingoffilm Thickness 25 Microns Nominal On The Exposed Face / Exterior Side And On The Reverse Side ( Interior Face ) Shall Be White With 15 Microns Film Thickness, Over A Coat Of 5 Micron Nominalthickness Primer. 44 M & L Aluminium Powder Coated Ofthree Track Sliding Window Consisiting Of Outer Frame Top & Sides ( Section No-20831 ) Of Size 92.0X31.75X1.5Mm Weighing 1.06 Kg / M, Frame Bottom ( Section No 20832 ) Of Size 92.0X31.75X1.5Mm Weighing 1.248Kg / M , Shutter To Plain Vertical ( Section No 21093 ) Of Size 39X18x1.5Mm Weighing 0.634 Kg / M, Shutter Interlock Vertical Frame ( Section 21094 ) Of Size 39X18x1.55 Weighing 0.734 Kg / M, Shutter Bottom Horizontal Frame ( Section No 20551 ) Size 40X20x1.5Mm Weighing 0.484 Kg / M, With Powder Coating Of Min Thickness 50 Micron , Sliding Type With Out Sash Bars, Including 4Mm Thickness Colour Glass, Rubber Packing, Snap Beading Screws With Stainless Steel Wire Mesh, Complete All As Specified Anddirected. 45 Note For Item No 44 :-The Minimum Thickness Of Powder Coating Shall Be 50 Micron 46 M & L Damp Proof Course 40 Mm Thick, In Plain Cement Concrete1:2:4, Type B-0, Using 12.5 Mm Graded Stone Aggregate Including Necessary Formwork Complete All As Specified And As Directed 47 M&L 150 Micron Thick, Polythene Film Laid Over A Coat Of Bitumen Primer, @ 0.30 To 0.50 Kg Per Sqm Complete All As Specified And Directed 48 S&F Steel Work In Tubular Trusses And Columns Including Special Shaped Washer Etc Complete Using Erw Or Induction Butt, Welded Tubes Conforming To Is 1161-1979 Grade St-240Complete All As Specified 49 S&F Framed Brackets Of Angles Or Tees With Web And Flanges, Cut To Shape, Drilled And Counter Sunk For Screw, Including Bending And Welding Angles, As Necessary , Gusset Plates, Riveting, Etc. N Exc10 Kg Each Brackets, Conforming To Fe.290.Gde -E-165Complete All As Specified 50 S&Fplates ( Plain Or Chequered ) Channels, Square Cut Or Notched ( Ordinary And Counter Sunk ) Forming Holes, With Riveted , Bolted Or Welded Attachment. ( Fe 410 -W ( Gde- E-250 ) Quality -A Complete Steelall As Specified 51 S&F Ms Flat Iron Wind Ties For Roof Including Securing Bolts And All Necessary Drilling, Bolting Or Riveting, Etc. , And Similar Work Conforming To Fe-290 Gde E-165 All As Specified And As Directed. 52 S&F Mild Steel Screw Bolts ( Machine Made ) With Hexagonal Or Square Heads At One End And Screwed The Other To Be Fitted With Washers And One Hexagonal Or Square Nuts, N Exc 5Cm Long Diameter Of Neck 5 To 10Mm Complete All As Specified And Directed. 53 M&L Preparation Of New Steel Surface Of Any Description N. Exc. 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over One Coat Of Red Oxide Primer Complete All As Specified And As Directed. 54 Note For Item No 53 :- ( A ) All Synthetic Enamel Paint, Shall Be Of 1St Quality Manufactured By The Standard Firms Of Make As Specified. 55 ( B ) The Contractor Shall Inform The Ge, Within Three Weeks Of The Acceptance Of The Tender, The Brand / Names Of The Manufacturers Of Paint Proposed To Be Used In The Works And Submit Samples Thereof And Obtain Prior Written Approval Of Ge Before Their Use In Works. 56 ( C ) The Contractor Shall When So Required By The Ge, Produce Certificate From The Manufacturer Or Their Representative To Establish That The Brands Of Paints Purchased By The Contractor From Them, Satisfy The Requirements Of The Relevant Indian Standards. Tint Of Paint, Will Be Approved By The Ge. 57 ( D ) Paints Shall Be Obtained Direct From Approved Manufacturer Or From Their Authorized Agents Only Of Respective Brands Mentioned Below And Brought To Site In Sealed Containers. The Paint So Procured Shall Be Of First Quality Of Any Approved Make As Per List Of Makes Specified. I. Berger Paints ( Luxol ) , Ii. Jenson & Nicholson ( Brolac ) , Iii. Shalimar Paints ( Superlac ) , Iv. Goodlass Nerolac ( Nerolac ) , V. Asian Paints ( Apcolite ) 58 ( E ) Unless Otherwise Specified The Tints Of Paint Shall Be As Approved By The Ge 59 ( F ) The Contractor Shall Submit Samples Of The Paints Proposed For The Work Along With Results Of Tests Conducted In Approved Laboratory As Directed By The Engineer-In-Charge For Approval. 60 ( G ) The Surface Shall Be Thoroughly Cleaned And Dusted. All Dirt Scales Oil And Grease Shall Be Thoroughly Removed Before Painting Is Started. The Prepared Surface Shall Be Inspected And Approved By The Ge Before Painting Is Commenced. The Weather Shall Not Be Foggy / Rainy, Dusty Or Windy. The Suitability Of The Weather Will Be Determined By The Engineer-In-Charge. 61 ( H ) No Hair Marks From The Brushor Clogging Of Paint Buddles Shall Be Left On The Work. Surface Shall Ordinarily Not Be Painted Until It Has Dried Up Completely. Trial Patches Of Paint Shall Be Laid At Intervals To Check If Drying Is Satisfactory. 62 ( E ) Unless Otherwise Specified The Tints Of Paint Shall Be As Approved By The Ge 63 ( F ) The Contractor Shall Submit Samples Of The Paints Proposed For The Work Along With Results Of Tests Conducted In Approved Laboratory As Directed By The Engineer-In-Charge For Approval. 64 M&L Hardcoreofgaugenotexceeding 63Mmofbroken Stonesorboulders, Deposited, Spreadandlevelledin Layersnotexceeding 15Cmthick, Wateredand Rammed To A True Surface Completeall As Specified And Directed. 65 M&L100 Mm Thick Pcc ( 1:2:4 ) Type B-2 Using40 Mm Graded Stone Aggregate As In Sub Base Floors For Receiving Tiles Complete All As Specified And As Directed. 66 M & L Moorum / Red Bajrifilling Including Spreading And Levelling In Layers Not Exceeding 15 Cm Thick, Spread, Levelled And Rammed Including Watering Complete All As Specified And Directed. 67 M&L Vitrified Ceramic Tiles 10 Mm Thick, Lightshade ( Square / Rectangular ) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, Laid Over Andincluding Screed Bed Or Bedding Layer, 15 Mm Thick In Cement Mortar 1:6Complete All As Specified And As Directed. 68 M&L Vitrified Ceramic Tiles 10 Mm Thick, Lightshade ( Square / Rectangular ) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Vertical Surfaces Such As Skirting / Dado Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, Laid Over Andincluding Backing Coat With 15 Mm Thick In Cement Mortar 1:6 Complete All As Specified And As Directed. 69 Note For Item No67 & 68 :- ( I ) Vitrified Tiles Are Classified Under Group B1a Of The International Standard For Ceramic Tiles Iso: 13006. Tiles Shall Be Hard, Dense, Impervious And Frost Resistant. Water Absorption Of Tiles Shall Be Less Than 0.5% And Flexural Strength ( Modulus Of Rupture ) Shall Be More Than 35 N / Sqmm. 70 ( Ii ) The ManufacturerS Test Certificate Andindividual Test Certificateof Tilesmust Be Submitted For Approval By The Concerned Authority Prior To Installation. 71 S & F Machine Pressed Rubber Moulded Precast Concrete Interlocking Paver Block With Grey Cement And Pigment Any Shape And Size, Polished Confirming To Is-15658 Of 80Mm Thickness M-40 Grade, Laid Over And Including M Sand Cushion Of 50Mm Thick Complete And Packing The Sides With Pcc 1:3:6 Complete All As Specified And Directed. 72 ( B ) The ManufacturerS Test Certificate Andindividual Test Certificateof Tilesmust Be Submitted For Approval By The Concerned Authority Prior To Installation. 73 M&L False Ceiling Using Gi Snap Grid Size 60X60cm With Main Runner 38Mmx24mm, Wall Angle & Cross Tee 29Mmx24mm Wall Angle 24Mmx24mm Suspended With 4Mm Dia Gi Wire Fixed With Steel Dash Fasteners Carrying Max Load Upto 8.1 Kg / Sqcm Including Supply And Fix 4Mm Thick Designer Ceiling Board Complete All As Specified And As Directed By Engineer-In-Charge. 74 M&L Brickwork With Subclass ‘B’ Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Thick Walls Built In Cm 1: 4Completeall As Specified And Directed. 75 M&L Point Wiring Using Approved Colour Coding As Per Iswith Pvc Insulated, Unsheathed Frls Multi Stranded Copper Conductor 1.5 Sqmm ( Nominal Area ) 1100 Volt Grade Cable For Phase & Neutral Drawn Through 20Mm Dia Pvc Conduit Fixed On Surface Ofwall, Columns Etc Including Pvc Insulated, Unsheathed Frls Multi Stranded Copper Conductor 1.5 Sqmm ( Nominal Area ) Copper Conductor As Earth Wire And Connected To Earth Dolly For The Following Complete All As Specified And Directed. 76 One Light Point / Ceiling Fan / Exhaust Fan / Bell Point Controlled By One Switch 77 All As Per Item No. 75 Here In Before But For One 3 Pin Socket Out 6 Ampon The Same Board 78 All As Per Sl No 75 Above But Wiring With 2.5 Sqmm Copper Multistranded Unsheathed Cable And 2.5 Sqmm Copper Cable For Earth Continuity Conductor Controlled By One 16A Switch Socket Independently 79 S&Ffactory Madepowder Coated Distribution Board Sp & N 8 Way Double Door, Including200 Amp Rated Bus Bar, Neutral Bar, Standard Din Rail, Earth Bar Complete All As Specified And Conforming To Is: 8623Complete All As Specified And Directed. 80 M&L For Sub Main Wiring With Pvc Insulated Unsheathed Frls Cable 1100 Volts Grade Multi Stranded Copper Conductor Cable 2 Runs Of 6 Sqmm Drawn Through In And Including Suitable Size Pvc Conduit With All Accessories Fixed To Wall / Floors Along With One Run Of6 Sqmm Pvc Insulated Unsheathed Copper Conductor Multi Stranded Cable 1100V Grade As Earth Continuity Conductor And Connected To Common Earth Dolly Complete All As Specified And Directed. 81 Note For Item No 80:- ( A ) 2 Runs Of 6 Sqmm Cable Along With 1Run Of 6 Sqmm Cable For Earth Conductor And One Run Ofpvc Conduit Shall Be Measured As One Length. 82 ( B ) Connections Of Cables With Mcbs Or Bus Bars Shall Be Done Through Appropriate Size Brass / Copper Thimbles. 83 S & F Modular Switch1 Way 6 Amp.1 Module Complete All As Specified And Directed. 84 S & Fmodular Switch1 Way 16 Amp.1 Module Complete All As Specified And Directed. 85 Supply & Fix Modular Socket Outlet 6A - 2 / 3 Pin Combined 2Module, Complete All As Specified And Directed. 86 Supply & Fix Modular Socket Outlet 6A / 16A - 2 / 3 Pin Combined 2Module, Complete All As Specified And Directed. 87 Supply & Fixmodular White Cover Plate With Frame, 3 Module Complete All As Specified And Directed. 88 Supply & Fixmodular White Cover Plate With Frame, 6 Module Complete All As Specified And Directed. 89 Supply & Fixmodular White Cover Plate With Frame, 8 Module Complete All As Specified And Directed. 90 S & F Modular Metal Flush Box, 3 Module Complete All As Specified And Directed. 91 S & F Modular Metal Flush Box, 6 Module Complete All As Specified And Directed. 92 S & F Modular Metal Flush Box, 8 Module Complete All As Specified And Directed. 93 Supply And Fixing Led Light Fitting 1X 20W, 220V, Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And Directed. 94 S & F Led Light Fitting 1X9w / 1X10wbulkhead Luminaires Including Led Light Driver Holder Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And Directed. 95 Supply And Fixing Led Light Fitting Mirror Type With High Out Put Diffuser 2 Feet, 5 Watt 220 V Ac Decorative Type With Driver Holder And Led Lamp Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And Directed. 96 Supply And Fixing Ceiling Fans With Brushless Direct Current Motor ( Bldc ) , Five Star Rated, 230V, Min Air Delivery 210 Cfm With Service Value 6.00 Bee., 1200 Mm Sweep Complete With Blades, Down Rods And Fittings Accessories Like Flexible Copper Cord If Size 1.5 Sqmm Etc, Complete All As Specified And Directed. 97 Supply And Fix Exhaust Fan, Steel Body Ac Single Phase. 230V Of Size 300Mm Sweep With, Blades, And Frame And Louvers Complete All As Specified And Directed. 98 S&F Electronicmodular Fan Regulator 230 Volts, Step Type, Socket Type, Hum Free 120 Watt 2 Module Complete All As Specified And Directed. 99 Supply & Fix Single Pole Mcb 6 To 32 Amp, 240 V, 50 Hz Acsuitable For ‘C’ Curve, 10 Ka Breaking Capacity Conforming To Is 8828 Of 1996Complete All As Specified And Directed. 100 Supply & Fix Single Pole Neutral, Mcb 32 Amp, 240 V, 50 Hz Acsuitable For ‘C’ Curve, 10 Ka Breaking Capacity Conforming To Is 8828 Of 1996Complete All As Specified And Directed. 101 Supply And Fixing Led Street Light Fitting 20 Watt, 230 V Ac Outdoor Type With High Pressure Die Cast Aluminium Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65 / 66 Protection Complete All As Specified And Directed. 102 M & L For Making Connection Of Pp-R Distribution Branch With Pp-R Main Of Sizes16 To 40 Mm Bore By Providing And Fixing Tee Including Cutting And Making Fusion Joint Etc Complete All As Specified And Directed. 103 Supply And Fixing Pp-R Gate Valves ( Brass Insert ) 25 Mm Outer Dia With Iron Wheel Head Screwed Both Ends For Iron Pipes Complete All As Specified And Directed. 104 S & F 25 Mm Outer Dia Of Pipes 3-Layer Pp-R ( Polypropylene Random Copolymer ) Pipes Concealed Pipes Sdr 7.4 ( Pn-16 @ 20°C ) Uv Stablised And Anti Microbial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Complete To Walls, Ceilings Or In Floors Etc. All As Specified And Directed. 105 Note For Item No 104 :- ( A ) The Unit Rate Shallinclude The Cost Of Short Lengths, With All Pipe Fittings Such As Bends, Tees, Short Pieces Connectors, Elbows, Reducers, Unions, Sockets Etc And Fixing Accessories Such As Pipe Hooks, Screws Clamps Etc 106 ( B ) Wall Thickness Of Pipes Shall Be All As Per Is : 15801 107 S & F Ball Brass Valves Of Size 25Mm Bore, High Pressure, With Polythene Float And Fly Nut Complete, Screwed For Iron Pipe Or Brass Ferrule Complete All As Specified And Directed. 108 Removingexcavated Material To A Distance Not Exc. 50M And Depositing Where Directed At Level Not Exc 1.5 M Above Complete All As Specified And As Directed. 109 S & F Rotational Moulded Polythene Water Storage Tank Of500 Ltrs Capacity Cylindricalvertical With Closed Top Including 3 Nos Gi Check Nuts And Tank Nipple Of 25Mm Bore For Inlet And Outlethoisted And Fixed In Position All As Specified In Ssr Part -I Including Complete All As Specified And Directed. 110 S & F Xlpeinsulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Electric Power Cable Heavy Duty With Aluminium Conductor 1100Volts Grade Cross Sectional Area 16 Sqmm 4 Core Laid In Trenches / Ducts / Fixed To Wall / Pole / Inside Panel / Drawn Through Pipe Including Cable Glands And Terminal Sockets Complete All As Specified And Directed 111 M & L Earthing With Galvanised Earth Plate Electrode 600X600x 6Mm Thick Buried Directlyin Ground ( Earth Pit Not Less Than 2.25 Metre Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.50 Metre Below Ground Level, Connected With Galvanised Iron Earth Wire 4Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Gi Or Steel And Connected Earthing Testing Point / Bus-Bar Including Gi 15Mm Bore ( Dia ) Medium Grade Protection Pipe, Earth Plate Surrounded By A Packed Thickness Of Char Coal Or Coke Dust Mixed With Common Salt, Magneisum Sulphate ( 1 : 1 : 0.5 ) In Alternate Layers Of Not Exc 150Mm Thick, Pcc Pit In Cement Concrete 1:3:6, Type C-1 Using 20Mm Graded Stone Aggregate And Pre-Cast Rcc Cover Slab Of Size 300X300x40 Mm In Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate, Reinforced With 10Mm Dia Tmt Bars @ 100Mm Centre To Centre In Both Ways, Gi Wire Mesh, Funnel With Gi Watering Pipe 20Mm Bore ( Dia ) Medium Grade Including Necessary Excavation In Any Type Of Soil, Returning, Filling In And Removal Of Surplus Spoil Disposal To Out Side Md Land And All As Shown In Electrical Plate No. 3 Of Mes Schedule Part-I And Testing On Completion Etc Complete All As Per Specified And Directed. 112 Note For Item No 111:- ( A ) All Joints Should Be Joined By Exothermic Welding Or Brazing. 113 ( B ) After Completion Of Work Earthing Shall Be Tested By The Contractor In Presence Of Engineer-In-Charge, User And Proper Record Shall Be Maintained Duly Signed By All Concerned. 114 ( C ) Earth Resistance Tester Shall Be Provided By The Contractor. It Should Be Calibrated From Authorised Company / Lab. 115 ( D ) After Testing If Desired Earth Resistance Of Less Than 5 Ohm Is Not Obtained, The Earthing Will Be Redone Without Extra Cost To Govt Till Desired Result Is Obtained. 116 S&F Factory Madepowder Coated Distribution Board Vtpn, 4 Way Double Doorincludingbus Bar, Neutral Bar, Standard Din Rail, Earth Bar Completeall As Specified And Conforming To Is: 8623 Completeall As Specified And Directed. 117 S&F Mccb Four Pole, 63 Amp Ultimate Breaking Capacity 16 Ka, 415V Including Connecting By Using Suitable Size Of Lugs Complete Conforming To Iec -61439-1 Complete All As Specified And As Directed. 118 S&F Mccb Four Pole, 40 Amp Ultimate Breaking Capacity 16 Ka, 415V Including Connecting By Using Suitable Size Of Lugs Complete Conforming To Iec -61439-1 Complete All As Specified And As Directed. 119 S & F 40 Mmbore Gi TubingLight GradeFor Protection Of Lt Cables Fixed To Walls / Poles / Road Crossing Including Clamps And Fittings Complete All As Specified And Directed. 120 M&L Fly Ash Bricks Using Modular Bricks As In Cable Protection Covercomplete All As Specified And Directed. 121 Riddling Sand Obtained From Excavation For Cable Protection 8Cm Under The Cable And 15Cm Above The Cable In Trench And Get The Thick Layer Of 18Cm After Ramming Complete All As Specified And As Directed. 122 Note For Item No 121 :-In Case Sufficient Sand Not Obtained From Excavation, The Required Additional Qty Shall Be Obtained From Out Side Md Land As Directed By The Engineer-In-Charge And The Rate Is Deemed To Be Included The Above Provision Also. 123 Supply And Fix In Repairs To Ms C-Track With Accessories Without Cable Of Existing Size And Gauge Suitable For 3 / 2 Ton Crane Complete All As Specified And Directed.Make : Rockwell Or Equivalent Approved As Directed 124 Supply And Fix In Repairs To6+2 Pendent Suitable For 3 / 2 Toneot Crane Complete All As Specified And Directed. Make:-Schneider Or Equivalent Approved As Directed 125 Supply And Fix In Repairs Tofeston Trolley Suitable For 3 / 2 Ton Rockwell Eotcrane Complete All As Specified And Directed. 126 Supply And Fix In Repairs Toct, Lt, Hoist Limit Switch With Connected Arrangements Of 3 / 2 Ton Eot Crane Complete All As Specified And Directed. Make: Rockwell Or Equivalent Approved As Directed 127 Supply And Laying Of Pvc Copper Conductor Electric Flat Cable Of Size 1.5 Sqmm, 16 Core On Wall, Floor, Ceiling Etc Including Taking Down Existing Cable Complete All As Specified And Directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 97400.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PROVISION OF CERTAIN SANCTIONED AND MAJOR REVENUE WORKS AT AF STN SULUR
Sl. No. Item Description
1SCHEDULE A BOQ
2Surface excavation n.exc 30 cm deep and averaging 15cm deep in soft/loose soil complete all as specified and as directed.
3Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying XLPE cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified and as directed.
4M&L PCC (1:4:8) Type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
5M&L Reinforced cement concreteType B-0, 1:2:4 using 12.5mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
6M&L formwork to sides and soffits offloor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc to provide flat rough finished concrete surface complete all as specified and as directed.
7M&L Reinforced cement concrete Type B-0, 1:2:4 using 12.5mm graded stone aggregate slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and as directed.
8M&L Formwork to soffits of suspendedslabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) to provide flat rough finished concrete surface complete all as specified and as directed.
9M&L Formwork toedges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide to provide flat rough finished concrete surface complete all as specified and as directed.
10M&L Reinforced cement concrete Type B-0, 1:2:4 using 12.5mm graded stone aggregate as in Chajjascomplete all as specified and as directed.
11M&L Formwork to chullah hoods, chajjas,troughs and similar items including edges to provide flat rough finished concrete surface complete all as specified and as directed.
12S&F High strength corrosion resistant TMT steel bars of Grade Fe–500of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
13S&F High strength corrosion resistant,TMT steel bar of grade Fe-500, 5 mm dia and above and up to 10 mm dia cut to length, bent to shape required,including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips in stirrups , spacers and binders etccomplete all as specified and as directed.
14M&L100 mm thick PCC (1:4:8) type-D-2 using40 mm graded stone aggregate as in sub base floors complete all as specified and as directed.
15M&L 25mm thick Cement concrete type B-1,1:2:4 using 20mm graded stone aggregate as in floors complete all as specified and as directed.
16M & L pre-cast cement concrete block masonry with solid blocks, type C-1, in PCC 1:3:6 using 20 mm graded aggregate, exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed.
17M&L Rendering 10mm thick on brick work or concrete surfacesin cementmortar 1:4 and finishedeven and smooth without using extracement complete all as specified and as directed.
18M&L preparation on newly plastered wall surfaces and applying two coats of oil bound distemper over the wall treated with 2mm thick plaster of paris putty and one coat of alkali resistant primer complete all as specified and directed.
19M&L Rendering 15 mm thick onbrick or concrete wall surfaces, in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
20M&L preparation on newly plastered wall surfaces and applying two coats of cement base paint one coat of alkali resistant primer complete all as specified and directed.
21M&L 75mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded stone aggregates), as in Plinth protection/ Path including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement,complete all as specified and as directed.
22Note for item No 21 :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
23Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
24Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and as directed.
25M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
26M&L Preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
27Note for item No 26 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
28(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
29(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
30(d)Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
31(e )Unless otherwise specified the tints of paint shall be as approved by the GE
32(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
33(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
34(h) No hair marks from the brushor clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
35(e)Unless otherwise specified the tints of paint shall be as approved by the GE
36(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
37S& F Steel rolling shutterswith out ball bearing, springas per specified including top cover, anchoring rod, hasp and staple withone shop coat of primerand two coats of synthetic enamel paint with gear operated box (approved quality ) erected in position and making good the surface after fixing including locking system complete all as specified and as directed .
38S&F Pre painted Coloured corrugated Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheetany colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as specified anddirected.
39M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mmthick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified anddirected.
40Note for Item No 38 & 39:- (Pre-painted coloured Galvalume roofing) :-
41(i) The manufacturer"s test certificate andindividual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
42(ii) The contractor shall ensured that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Totalcoated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
43(iii) The painting shall be coloured baked enamel polyesterwith silicon coatingoffilm thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominalthickness Primer.
44M & L Aluminium powder coated ofthree track sliding window consisiting of outer frame top & sides (section no-20831) of size 92.0x31.75x1.5mm weighing 1.06 Kg/m, frame bottom (Section No 20832) of size 92.0x31.75x1.5mm weighing 1.248Kg/m , shutter to plain vertical (Section No 21093) of size 39x18x1.5mm weighing 0.634 Kg/m, shutter interlock vertical frame (section 21094) of size 39x18x1.55 weighing 0.734 Kg/m, shutter bottom horizontal frame (Section No 20551) size 40x20x1.5mm weighing 0.484 Kg/m, with powder coating of min thickness 50 micron , sliding type with out sash bars, including 4mm thickness colour glass, rubber packing, snap beading screws with stainless steel wire mesh, complete all as specified anddirected.
45Note for item No 44 :- The minimum thickness of powder coating shall be 50 micron
46M & L damp proof course 40 mm thick, in plain cement concrete1:2:4, type B-0, using 12.5 mm graded stone aggregate including necessary formwork complete all as specified and as directed
47M&L 150 micron thick, Polythene film laid over a coat of bitumen primer, @ 0.30 to 0.50 kg per sqm complete all as specified and directed
48S&F Steel work in tubular trusses and columns including special shaped washer etc complete using ERW or induction butt,welded tubes conforming to IS 1161-1979 grade ST-240complete all as specified
49S&F Framed brackets of angles or tees with web and flanges, cut to shape, drilled and counter sunk for screw, including bending and welding angles, as necessary , gusset plates, riveting, etc. n exc10 kg each brackets, conforming to Fe.290.Gde -E-165complete all as specified
50S&FPlates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted , bolted or welded attachment.(Fe 410 -W (Gde- E-250) quality -A complete steelall as specified
51S&F MS flat iron wind ties for roof including securing bolts and all necessary drilling, bolting or riveting, etc. , and similar work conforming to Fe-290 Gde E-165 all as specified and as directed.
52S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, n exc 5cm long diameter of neck 5 to 10mm complete all as specified and directed.
53M&L Preparation of new steel surface of any description n. exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
54Note for item No 53 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
55(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
56(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
57(d)Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
58(e )Unless otherwise specified the tints of paint shall be as approved by the GE
59(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
60(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
61(h) No hair marks from the brushor clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
62(e)Unless otherwise specified the tints of paint shall be as approved by the GE
63(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
64M&L Hardcoreofgaugenotexceeding 63mmofbroken stonesorboulders,deposited,spreadandlevelledin layersnotexceeding 15cmthick,wateredand rammed to a true surface completeall as specified and directed.
65M&L100 mm thick PCC (1:2:4) type B-2 using40 mm graded stone aggregate as in sub base floors for receiving tiles complete all as specified and as directed.
66M & L moorum/red bajrifilling including spreading and levelling in layers not exceeding 15 cm thick, spread, levelled and rammed Including watering complete all as specified and directed.
67M&L Vitrified Ceramic tiles 10 mm thick, lightshade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer, 15 mm thick in Cement Mortar 1:6complete all as specified and as directed.
68M&L Vitrified Ceramic tiles 10 mm thick, lightshade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding backing coat with 15 mm thick in Cement Mortar 1:6 complete all as specified and as directed.
69Note for item No67 & 68 :- (i) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm.
70(ii) The manufacturer"s test certificate andindividual test certificateof Tilesmust be submitted for approval by the concerned authority prior to installation.
71S & F Machine pressed rubber moulded precast concrete interlocking paver block with grey cement and pigment any shape and size, polished confirming to IS-15658 of 80mm thickness M-40 grade, laid over and including M sand cushion of 50mm thick complete and packing the sides with PCC 1:3:6 complete all as specified and directed.
72(b)The manufacturer"s test certificate andindividual test certificateof Tilesmust be submitted for approval by the concerned authority prior to installation.
73M&L False ceiling using GI snap grid size 60x60cm with main runner 38mmx24mm, wall angle & cross tee 29mmx24mm wall angle 24mmx24mm suspended with 4mm dia GI Wire fixed with steel dash fasteners carrying max load upto 8.1 Kg/Sqcm including supply and fix 4mm thick designer ceiling board complete all as specified and as directed by Engineer-in-Charge.
74M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1: 4completeall as specified and directed.
75M&L point wiring using approved colour coding as per ISwith PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through 20mm dia PVC conduit fixed on surface ofwall, columns etc including PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) copper conductor as earth wire and connected to earth dolly for the following complete all as specified and directed.
76One light point/ceiling fan/exhaust fan/bell point controlled by one switch
77All as per item No. 75 here in before but for One 3 pin socket out 6 ampon the same board
78All as per Sl No 75 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 16A switch socket independently
79S&Ffactory madepowder coated distribution board SP & N 8 way double door,including200 Amp rated bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623complete all as specified and directed.
80M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and including suitable size PVC conduit with all accessories fixed to wall/floors along with one run of6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.
81Note for Item No 80:- (a)2 runs of 6 sqmm cable along with 1run of 6 sqmm cable for earth conductor and one run ofPVC conduit shall be measured as one length.
82(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
83S & F modular switch1 way 6 amp.1 module complete all as specified and directed.
84S & Fmodular switch1 way 16 amp.1 module complete all as specified and directed.
85Supply & fix modular socket outlet 6A - 2/3 pin combined 2 module,complete all as specified and directed.
86Supply & fix modular socket outlet 6A/16A - 2/3 pin combined 2 module,complete all as specified and directed.
87Supply & fixmodular White cover plate with frame, 3 module complete all as specified and directed.
88Supply & fixmodular White cover plate with frame, 6 module complete all as specified and directed.
89Supply & fixmodular White cover plate with frame, 8 module complete all as specified and directed.
90S & F modular Metal flush box, 3 module complete all as specified and directed.
91S & F modular Metal flush box, 6 module complete all as specified and directed.
92S & F modular Metal flush box, 8 module complete all as specified and directed.
93Supply and fixing LED light fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
94S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
95Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 5 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
96Supply and fixing ceiling fans with brushless direct current motor (BLDC), five star rated, 230V, Min air delivery 210 CFM with service value 6.00 BEE.,1200 mm sweep complete with blades, down rods and fittings accessories like flexible copper cord if size 1.5 sqmm etc, complete all as specified and directed.
97Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
98S&F electronicmodular fan regulator 230 volts, step type, socket type, hum free 120 watt 2 Module complete all as specified and directed.
99Supply & fix single pole MCB 6 to 32 amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996complete all as specified and directed.
100Supply & fix single pole neutral, MCB 32 amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996complete all as specified and directed.
101Supply and fixing LED street light fitting 20 Watt, 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
102M & L for making connection of PP-R distribution branch with PP-R main of sizes16 to 40 mm bore by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
103Supply and fixing PP-R Gate Valves (Brass insert)25 mm outer dia with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
104S & F 25 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. all as specified and directed.
105Note for item No 104 :- (a) The unit rate shallinclude the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accessories such as pipe hooks, screws clamps etc
106(b ) Wall thickness of pipes shall be all as per IS : 15801
107S & F ball brass valves of size 25mm bore, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
108Removingexcavated material to a distance not exc. 50m and depositing where directed at level not exc 1.5 m above complete all as specified and as directed.
109S & F rotational moulded polythene water storage tank of500 Ltrs capacity cylindricalvertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlethoisted and fixed in position all as specified in SSR part -I including complete all as specified and directed.
110S & F XLPEinsulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets complete all as specified and directed
111M & L earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick buried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised iron earth wire 4mm dia by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 15mm bore (dia) medium grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6, type C-1 using 20mm graded stone aggregate and Pre-cast RCC Cover Slab of size 300x300x40 mm in Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate, reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, returning, filling in and removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and testing on Completion etc complete all as per specified and directed.
112Note for Item No 111:- (a)All Joints should be joined by Exothermic Welding or Brazing.
113(b)After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
114(c)Earth resistance tester shall be provided by the contractor. It should be calibrated from authorised company/ lab.
115(d)After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone without extra cost to Govt till desired result is obtained.
116S&F factory madepowder coated distribution board VTPN, 4 way double doorincludingbus bar, Neutral bar, standard DIN rail, earth bar completeall as specified and conforming to IS: 8623 completeall as specified and directed.
117S&F MCCB four pole, 63 Amp ultimate breaking capacity 16 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed.
118S&F MCCB four pole, 40 Amp ultimate breaking capacity 16 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed.
119S & F 40 mmbore GI tubing"light grade"for protection of LT cables fixed to walls/ poles/ road crossing including clamps and fittings complete all as specified and directed.
120M&L Fly ash bricks using modular bricks as in cable protection covercomplete all as specified and directed.
121Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and as directed.
122Note for Item No 121 :- In case sufficient sand not obtained from excavation, the required additional qty shall be obtained from out side MD land as directed by the Engineer-in-Charge and the rate is deemed to be included the above provision also.
123Supply and fix in repairs to MS C-Track with accessories without cable of existing size and gauge suitable for 3/2 Ton crane complete all as specified and directed. Make : Rockwell or equivalent approved as directed
124Supply and fix in repairs to6+2 pendent suitable for 3/2 TonEOT crane complete all as specified and directed. Make:-Schneider or equivalent approved as directed
125Supply and fix in repairs tofeston trolley suitable for 3/2 Ton Rockwell EOTcrane complete all as specified and directed.
126Supply and fix in repairs toCT, LT, Hoist limit switch with connected arrangements of 3/2 ton EOT Crane complete all as specified and directed. Make: Rockwell or equivalent approved as directed
127Supply and laying of PVC copper conductor electric flat cable of size 1.5 sqmm, 16 core on wall, floor, ceiling etc including taking down existing cable complete all as specified and directed.