Military Engineer Services-MES has published Tender For Repair/Replacement And Maintenance Of Water Distribution Line, Valve Chamber, Lt Panels/Starter And Attending Emergency Breakdown To Distribution Line At Dolphin Hills Under Ge (U-Ii) Visakhapatnam. Submission Date for this Tender is 06-11-2023. Valve Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | M & L for Jungle cleaning by cutting and clearing away all grass vegetation, wild growth, sapling, shrubs, brushwoods, under growth roots, cutting of bushes, tree trunk of girth not execeeding 30 cm, cutting of trunk, portion protuding over ground, filling holes and leveling of ground and removing unserviceable materials to a distance n.exe 50m, complete all as speicified and directed. |
2 | Supply and replacement of MS ERW pipe heavy grade pipe 300 mm bore, thickness not less than 5.6 MM laid on suitablesize PCC Pillar supports, clamps, bolts and nuts including necessary Tees, elbows, flanges, including cutting etc andpreparation of pipe surface and applying two coats of synthetic enamel paint over a coat of zinc chrome primer in open places and with bitumen coating/felt cover for inserting the pipe in position and including making leak proof joints, complete all as specified and directed. |
3 | All as per Srl item No.2 above but 200 mm bore. |
4 | All as per Srl item No.2 above but 150 mm bore. |
5 | All as per Srl item No.2 above but 100 mm bore. |
6 | All as per Srl item No.2 above but 80 mm bore. |
7 | M & L for Cutting/drillingof CI/DI pipe of Size 100/150/200/300 mm bore and inserting 100/150/200/300 mm bore presure relese valve complete with all necessary items such as flanges, DI Specials, welding etc as required on site, complete all as specified and directed. |
8 | Supply and replacement ofPresure Reducing Valve of 200mm dia, flanged end type having material of construction Ductile Iron, spring, pilot valve, internal trims and wetted parts ofSS-304, diaphragm of nylon with nitrile reinforcement. complete all as specified and directed. |
9 | All as per Srl item No 8 butfor 150 MM bore |
10 | All as per Srl item No 8 but for 100 MM bore |
11 | Labour for attending GI pipe line complaints (break downs) in buildings upto G+3 floor in trenches/ floors/ path/walls for pipe of size 20 mm to 50 mm dia including cutting and threading of pipes as per site requirement complete all as specified and directed. Note:- The Quoted rates shall be deemed to inclusive of all GI fittings like bends, sockets, unions, reducers and elbows etc., as required at site. However, GI Pipeshall be measured and paid separately under relevent items. |
12 | Supply and layGI water tubing of 25mm bore galvanisedmedium gradein floors/ on roof /on wall / trenches with all fittings of below sizes of pipes, complete all as specified and as directed. |
13 | All as per Srl item No 12.00 but for 40 mm bore |
14 | All as per Srl item No 12.00 but for 50 mm bore |
15 | All as per Srl item No 12.00 but for 80 mm bore |
16 | All as per Srl item No 12.00 but for 100 mm bore |
17 | Supply and fix 20 mm dia Gun metal gate valve, with iron wheel head, screwed both ends for iron pipe and fixed including cutting the pipe line and taking down old unserviceable valves,complete all as specified and directed. |
18 | All as per Srl item No 17.00 above but 25 mm dia. |
19 | All as per Srl item No.17.00 above but 40 mm dia. |
20 | All as per Srl item No.17.00 above but 50 mm dia. |
21 | Supply and replacement 50 mm dia high density polythene pipe (HDPE) of pressure rating 6 Kg/ Sqcm, including making leak proof joints on walls/ceilings/laid in floors, complete all as specified and directed. |
22 | All as per Srl item No.21.00 above but 32 mm dia. |
23 | All as per Srl item No.21.00 above but 25 mm dia. |
24 | M&L replacement of unserviceable sluice valve of size100mm, spindle, and check nut by un screwing nut and bolts, gasket stuffing box and taking upper portion of sluice valve taking out u/s spindle check nut . Cutting turning, polishing and preparing new SS spindle and check nut from the solid single SS piece of same length , diaof u/s spindle and check nut fixing the new spindle and check nut re assembling sluice valve replacement of u/s gasket nut and bolts and testing, complete all as specified and directed. |
25 | All as per Srl item No.24.00 above but for150mm dia |
26 | All as per Srl item No.24.00 above but for 200mm dia |
27 | Taking out 100 dia sluice valve stuffing box and re-packing stuffing box of sluice valveincluding taking apart & assembling & refixing it into its original position & replacement ofrubber gasket and nut & bolts, complete all as specified and directed. NOTE- Rubber gasket, nuts, bolts and washers shall be measured and paid separately |
28 | All as per Srl item No.27.00 above but for150mm dia |
29 | All as per Srl item No.27.00 above but for 200mm dia |
30 | Supply only rubber gasket 3 mm thick, complete all as specified and directed. |
31 | Supply only black bolt with hexagon head and nuts round neck with washer 3 mm thick, complete all as specified and directed. |
32 | Supply and replace 300 mm bore CI sluice valves PN 1.6 (Non - Raising type) conforming to IS 14846 flanged end with iron wheel head and stainless steel spindle flanged joints including necessary nuts, bolts, and washers etc, complete all as specified and directed. |
33 | All as per Srl Item No.32.00 above but for 200 mm dia |
34 | All as per Srl Item No.32.00 above but for 150 mm dia |
35 | All as per Srl Item No.32.00 above but for 100 mm dia |
36 | All as per Srl Item No.32.00 above but for 80 mm dia |
37 | M&L for jointing flanged valve of 100mm dia and fittings including provn of rubber or fibre board gaskets and washers required for jointing including taking out fibre gaskets and nuts & bolts, complete all as specified and directed. |
38 | All as per Srl Item No.37.00 above but for 150mm bore |
39 | All as per Srl Item No.37.00 above but for 200mm bore |
40 | All as per Srl Item No.37.00 above but for 250mm bore |
41 | M&L for PCC 1:3:6, type C1 (using 20 mm graded granite stone aggregate) for making good the surface where road cutting/ hard standing/ paths and Removing excavated/demolished materialto a distance n.exc. 50m, complete all as specified and directed. |
42 | M&L for stone masonry for walling of random rubble, uncaused, well bonded, built in cement mortar 1:4 for construction of thrust block for the support of water supply pipe line including demolition of stone masonry, complete all as specified and directed. |
43 | Material and labour for taking down defective foot valves from UG Sump, scraping the corrodedfootvalves and painting with one coat of red oxide along with black enamel paint, replacingrubber gaskets, bottom rubber with spring complete with replacement of necessary bolts, nuts, washers for 150/200 mm dia, complete all as specified and directed. |
44 | All as per Srl Item No. 43.00 above but for 80/100 dia |
45 | Supply and replace 200 mm bore CI non return valve with by pass arrangementwith necessary rubber gasket, nuts, bolts, and washers etc., complete all as specified and directed. |
46 | All as per Srl item No.45.00 above but 100 mm dia. |
47 | All as per Srl item No.45.00 above but 80 mm dia. |
48 | All as per Srl tem No.45.00 above but 50 mm dia. |
49 | Supply and fixing in repairs cast iron air release valve with two air outlets, 50 mm dia bore with isolating sluice valve and fixing up in water supply mains including necessary addition / alternation to DI pipe 100/80 mm dia bore with all necesary fittings, complete all as specified and as directed. |
50 | Supply and fixing in repair cast iron air release valve with two air outlets, 50 mm dia bore with isolating sluice valve and fixing up in water supply mains including necessary addition / alternation to DI pipe 250/200 mm dia bore with all necesary fittings, complete all as specified and as directed. |
51 | M&L masonary valve chamber of size 900x900x900 mm (internal dimensions) and including necessary excavation and earth work in any type of soil, 100 mm thick PCC 1:4:8 type D2 foundation, brick work in cement mortar 1:6, plastering internal and external surface 15 mm thick in CM 1:4, 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) coping, 50 x 50 x 6 mm thick MS angle iron, 5 mm thick MS plate cover with locking arrangement, painting exposed steel surfaces with two coats of synthetic enamel paint over a coat of zinc chrome primer including dismantling unserviceable, complete all as specified and directed. |
52 | All as per Srl item No.51 above but of size 1200x1200x1200 mm (internal dimensions) |
53 | Labour only for attending break down ofDI pipe of 300/250/200 mm bore pipeline bursting / cracks and including cleaning / removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes,DI Collar / mechanical Joints etc as per site requirement, testing for leakages of lead joints, testing and necessary dewatering, complete all as specified and directed. Note 1 :- The quoted rate shall be deemed to be include the following:- (i) Arrangement of suitable Pump sets for dewatering at the time of attending break down including JCB"s and Cranes as per site requirement . (ii) Necessary labour/trade men for attending break down. (iii)Labour element required for fixing DI pipes, specials, fittings etc. Note 2 :- Earth work, Supply only DI pipes, specials, fittings will be measured and paid seperately under relevant items. |
54 | All as per Srl item No 53 above but of size 150/100 mm bore |
55 | Supply only DI K9 water supply pipe lines of size 300 mm bore as per IS 455:1989 bituminous coating as per Annex "C" of IS 8329 with push-on joints, complete all as specified and directed. |
56 | Supply only DI K9 water supply pipe lines of size 250 mm bore as per IS 455:1989 bituminous coating as per Annex "C" of IS 8329with push-on joints, complete all as specified and directed. |
57 | Supply only DI K9 water supply pipe lines of size 200 mm bore as per IS 455:1989 bituminous coating as per Annex "C" of IS 8329with push-on joints, complete all as specified and directed. |
58 | Supply only DI K9 water supply pipe lines of size 150 mm bore as per IS 455:1989 bituminous coating as per Annex "C" of IS 8329with push-on joints , complete all as specified and directed. |
59 | Supply only DI K9 water supply pipe lines of size 100 mm bore as per IS 455:1989 bituminous coating as per Annex "C" of IS 8329 with flanged ends, complete all as specified and directed. |
60 | Supply only DI specials such as bends (any type, radius and angle) tapers any type, straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch, "Y" junction, double branch, cross (all sockets or sockets and spigot) collars, caps and plugs upto 300 mm bore, complete all as specified and directed. |
61 | Burning out lead joint in position including removing old lead for the 150mm bore, complete all as specified and directed. |
62 | All as per Srl Item No.61 above but of size 200 mmbore. |
63 | All as per Srl Item No.61 above but of size 250 mmbore. |
64 | Material and labour for run lead joint for spigot and socketpipes (CI/DI) and fittings of size 100 mm, complete all as specified and directed. |
65 | All as per Srl Item No.64.00 above but of size 150 mmbore. |
66 | All as per Srl Item No.64.00 above but of size 200 mmbore. |
67 | All as per Srl Item No.64.00 above but of size 250 mmbore. |
68 | Supply and replace submersible pump controller 3 Ph, 415 V for pump capacity upto 5 HP, complete all as specified and as directed. |
69 | Excavating in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation, laying of cable/pipes etc. n exc 10 sq m on plan and getting out in soft/loose soil, complete all as specified and directed. |
70 | Returning filling in, including spreading levelling watering and well ramming in layers n.exc 25 cm thick, complete all as specified and directed. |
71 | Removing excavated surplus soilto a distance n.exc. 50m distance and depositing where directed at a level n.exc. 1.5 m above the starting point, complete all as specified and directed. |
72 | M&L for taking out existing any type pumpset/airblower of following capacity for servicing by disconnecting motor and blower/ pump set, pipe line and removing of all parts like bearing, bushes, impeller, shaft etc cleaning all surfaces and scales/ sludge/ dirt/formed inside/out side pumpset/blower etc Lubricating/ greasing at proper places and re fixing in position with all serviceable parts with motor incl painting with one coat of anti corrosive paint over red oxide primer and writing MES /SM No and testing and commissioning, complete all as specified and directed. Note : - Spares like bearings shall be measured and paid separately against supply only |
73 | 15 HP to 20 HP |
74 | 10 HP to 12.5 HP |
75 | 5/ 7.5 HP |
76 | 3 / 3.5 HP |
77 | Supply only ball bearingssuitable for centrifugal and mono block pumps motors as existing at site, complete all as specified and directed. |
78 | 15 HP to 20 HP |
79 | 10 HP to 12.5 HP |
80 | 5/ 7.5 HP |
81 | 3 / 3.5 HP |
82 | Supply only blower containers oil (SP320) as required at site, complete all as specified and directed. |
83 | Supply only CI impeller suitable for centrifugal / mono block pumps for the following capacities of 15-25 HP, complete all as specified and directed. |
84 | Supply only CI gland plate high tension studs for Centrifugal / mono block pumps for the following capacity of 15-25 HP, complete all as specified and directed. |
85 | M&L for disconnecting and removing the existing defective Mono block / centrifugal pump set motor of any make of following capacityfrom the installed position by putting dummy plate to suction and delivery removing the burnt out winding and re-winding the same with super enamelled copper wire of same gauge and same No of turns of existing make insulating winding with existing class of insulation varnishing baking up including replacement of base foundation nuts, bolts and re-installation of pump, testing to satisfactory performance, complete all as directed. Note :-Bearings, CI gland plates, Terminal block, shaft be measured and paid separately under relavent items of BOQ |
86 | 15 HP to 20 HP |
87 | 10 HP to 12.5 HP |
88 | 5/ 7.5 HP |
89 | 3 / 3.5 HP |
90 | Supply and replace 200 mm bore CI foot valve with stainer and necessary rubber gasket, nuts, bolts, and washers etc, complete all as specified and directed. |
91 | All as per Srl item No.90.00 above but 100 mm dia. |
92 | All as per Srl item No.90.00 above but 80 mm dia. |
93 | All as per Srl item No.90.00 above but 50 mm dia. |
94 | Supply only TCCA 90% Chlorine (Trichloroisocyanuric Acid), effective content of chlorine % :=90, content of water % : =0.5, PH Value of 1% Solution : 2.7 to 3.3, Granular Chlorine/Tablet in packing of 50 kg, complete all as specified and directed. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail