Power Government Departments Closing in 0 days TDR #40178721

Tender For In The Business Plan 2023-24 (20 Crores) In Power Distribution Division-First, Baraut, For The Works Like Capacity Enhancement/Installation Of Distribution Transformers, Line Construction And Installation Of Vcb Etc. On Semi Turnkey Basis.

Issued by Government Departments · baraut, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Nov 2023
0 days left
EMD
85000
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
baraut → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For In The Business Plan 2023-24 ( 20 Crores ) In Power Distribution Division-First, Baraut, For The Works Like Capacity Enhancement / Installation Of Distribution Transformers, Line Construction And Installation Of Vcb Etc. On Semi Turnkey Basis.-Pcc / Stp Pole / Converter And Other Line Material Received From Centralized Material Mandar Center Baghpat / Baraut / Meerut. Transport Work To Work Site ( Including Loading And Unloading ) - 400 Kva Converter 250 Kva Converter 100 Kva Converter 63 Kva Converter 25 Kva Converter Pcc Pole 8.5 Meter St Pole 11 Meter Acsr Weasel Conductor Asr Rabbit Conductor Ab Conductor 3X50 + 1X35 + 1X16 Sqmm Ab Conductor 3X95+1X70+1X16 Sqmm 11 Kv X0 Lpe Cable ( 3X185 Mm ) 11Kv Pin Insulator With Fittings 11 Kv Disc Insulator With Fittings 11Kv Outgoing Vcb 200 / 100 / 5A 11Kv Outgoing Vcb Ctr 200 / 100 / 5A 11Kv Outgoing Vcb 300 / 150 / 5A 11Kv Incoming Vcb 600 / 300 / 5A Pole By Digging Pit For Construction Of Dilapidated / Long Span / New Line The Act Of Installing. Pcc Pole 8.5 Meter St Pole 11 Meter Laying Of Conductors On Poles Erected For Dilapidated / Long Span / New Line Construction. A.S.S.R. Electrical Conductor Acsr Rabbit Conductor Ab0 Conductor 3X50+1X35+1X16 Sqmm Ab Conductor 3X95+1X70+1X16 Sqmm Laying Work. 11Kv Pin Insulator With Fittings Installation Work Of 11 Kv Disc Insulator With Fittings. Work Of Commissioning The Line By Installing 400 Kba Converter Trolley To Start The Line By Installing 250 Kba Converter At The Base Work . Installation Work Of 100 Kva Transformer On Double Pole Installation Work Of 63 Kva Transformer On Double Pole Installation Work Of 25 Kva Transformer On Double Pole 11Kv Outgoing Vcb 200 / 100 / 5A In Control Room The Work Of Establishing. 11Kv Outgoing Vcb Ctr 200 / 100 / 5A 11Kv Outgoing Vcb 300 / 150 / 5A 11Kv Incoming Vcb 600 / 300 / 5A The Work Of Digging A Pit For 11 Kv X-Lpe Cable ( 3X185 Mm ) And Making A Loop And Laying The Cable Till The Control Room / Double Pole. Digging Pit For 11 Kv Xlpe Cable ( 3X185 Mm ) And The Work Of Laying The Cable By Making A Loop. Materials To Be Provided By The Tenderer. 11Kv Cable Jointing Kit Outdoor 3.5X70 Sqmm 11Kv Cable Jointing Kit Indoor 3X185 Sqmm 11Kv Cable Jointing Kit Outdoor 3X185 Sqmm | 1X400 Sqmm Cable For Lead 11Kv Xlpe Cable ( 3.5X70sq.Mm ) |11 Kv Fuse Set Ms Venal 125X65x1300 T Off 2 A 125X65x3200 Mm 21 125X65x2240 Mm 2 100X50x2240 Mm Hoyo 75X75x6x2028 Mm For T / F Base Dopper Vane 100X50x2028mm Guarding Angle 75X75x6x1600mm 11 X-Arm Clam With Nutbolt F-Bracket F-Clamp Holding Clamp Dead And Clamp With J-Hook Suspension Clamp With J-Hook I-Hook Lt Distrubution Box 1 Phase With Clamp Lt Distrubution Box 3 Phase With Clamp Lt Schakle Insulator Lt Holding Clamp For Pcc / Stp With Nut Bolt Stay Set Complete Earthing Complete Chemical Earthing For Vcb / T.F Gi Wire 6Swg & 10 Swg For Guarding 24 Volt Battery And Battery Charger Stone Pad Copper Busbar Lt Xlpe Cable Unarmoured 3.5X50 Lt Cable 1X240 Sqmm Earthing Complete For Vcb ( Strip ) 33 Kv Lightening Arrestor 33 Kv Vcb With Double T / F Control Penal & Ct 200 / 100 / 1 A With Structer 33 Kv Post Insulator Control Cable 4X2.5 Sqmm Control Cable 2X2.5 Sqmm Gauting Work Of Polo Along With Necessary Materials. Work Of Making Base For 400 / 250 Kva Converter. Fencing Around The Plinth Of 400 / 250 Kva Transformer. Work . Providing Moving Trolley. Material Provided By The Bidder On Line Installation Work As Per Requirement. 11Kv Cable Splicing Kit Indoor 3X185 Sqmm 11Kv Cable Splicing Kit Outdoor 3X185 Sqmm 1X400 Sqmm Cable For Lead 11Kv Xpe Cable ( 3.5X70sq.Mm ) 11 Kv Fuse Set Ms Venal 125X65x1300 T Off 2 Al 125X65x3200 Mm 125X65x2240 Mm 21 100X50x2240 Mm Dopper Benal 100X50x2028mm Yoyo 75X75x6x2028 Mm For T / F Base If Ya 75X75x6x1600 Mm 11 Dl X-Arm Clam With Nutbolt F-Bracket F-Clamp Holding Clamp Dead And Clamp With J-Hook Suspension Clamp With J-Hook I-Hook Lt Distrubution Box 1 Phase With Clamp Lt Distrubution Box 3 Phase With Clamp Lt Schakle Insulator Lt Holding Clamp For Pcc / Stp With Nut Bolt Stay Set Complete Earthing Complete Chemical Earthing For Vcb / T.F Gi Wire 6 Swg & 10 Swg For Guarding 24 Volt Battery And Battery Charger Stone Pad Copper Busbar Lt Xlpe Cable Unarmoured 3.5X50 Lt Cable 1X240 Sqmm Earthing Complete For Vcb ( Strip ) 33 Kv Lightening Arrestor 33 Kv Vcb With Double T / F Control Penal & Ct 200 / 100 / 1 A With Structer 33 Kv Post Insulator Control Cable 4X2.5 Sqmm Control Cable 2X2.5 Sqmm Fencing Work Of Moving Trolley. Dilapidated And Old Electrical Material Removed From The Work Site The Work Of Delivering Safe Electricity To Mandar Centre. ( Loading Including Unloading ) 100 Kva Converter 250 Kva Converter |11 Kv Vcb Scrap 11 Kv Ctr Scrap | 11 Kv Pin Insulator Scrap 11 Kv Disk Insulator Scrap |11 Kv X-Arm Channel Angle Acsr Dog / Weasel Conductor Old & Use | Lt Ab Cable Old & Use Multiple Scrap

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 18-Oct-2023 Date extenson78 Date 26-Oct-2023
2 26-Oct-2023 extenddate78 Date 27-Oct-2023
3 27-Oct-2023 Dateextenson78-- Date 03-Nov-2023
4 03-Nov-2023 Dateextenson-78-- Date 08-Nov-2023
5 08-Nov-2023 Dateextenson-78..-- Date 10-Nov-2023

BOQ

Name of Work:fo|qr forj.k [k.M&izFke] cMkSr esa fctusl Iyku 2023&24¼20 djksM½ esa lseh VuZdh vk/kkj ij forj.k ifjorZdksa dh {kerko`f)@LFkkiuk] ykbZu fuekZ.k o ohlhch yxkus bR;kfn dk;ksaZ gsrqA
Sl. No. Item Description
1dsUnzh;d`r lkexzh Hk.Mkj dsUnz ckxir@cMkSr@esjB ls ihlhlh@,lVhih iksy@ifjorZd ,oa vU; ykbZu lkexzh izkIr dj dk;Z LFky rd igqpkus dk dk;ZA ¼yksfMax vuyksfMax lfgr½
2400 dsoh, ifjorZd
3250 dsoh, ifjorZd
4100 dsoh, ifjorZd
563 dsoh, ifjorZd
625 dsoh, ifjorZd
7ihlhlh iksy 8-5 ehVj
8,l0Vh0 iksy 11 ehVj
9,lh,lvkj ohty dUVDVj
10,0lh0,l0vkj0 jsfcV dUMDVj
11,0ch0 dUMDVj 3x50+1x35+1x16 sqmm
12,0ch0 dUMDVj 3x95+1x70+1x16 sqmm
1311 dsoh ,Dl0,y0ih0bZ0 dsfcy¼3x185 mm)
1411 dsoh fiu bUlqysVj QhfVax lfgr
1511 dsoh fMLd bUlqysVj QhfVax lfgr
1611 dsoh vkmVxksabZx ohlhch 200@100@5 ,
1711 dsoh vkmVxksabZx ohlhch lhVhvkj 200@100@5 ,
1811 dsoh vkmVxksabZx ohlhch 300@150@5 ,
1911 dsoh budfeax ohlhch 600@300@5 ,
20ttZj@yEcs LiSu@ubZ ykbZu fuekZ.k gsrq x<
21ihlhlh iksy 8-5 ehVj
22,l0Vh0 iksy 11 ehVj
23ttZj@yEcs LiSu@ubZ ykbZu fuekZ.k gsrq [kMs fd;s x;s iksyks ij dUMDVj fcNkus dk dk;ZA
24,0lh0,l0vkj0 ohty dUVDVj
25,0lh0,l0vkj0 jsfcV dUMDVj
26,0ch0 dUMDVj 3x50+1x35+1x16 sqmm
27,0ch0 dUMDVj 3x95+1x70+1x16 sqmm fcNkus dk dk;ZA
2811 dsoh fiu bUlqysVj QhfVax lfgr
2911 dsoh fMLd bUlqysVj QhfVax lfgr yxkus dk dk;ZA
30400 dsoh, ifjorZd VªkWyh LFkkfir djds ykbZu pkyw djus dk dk;ZA
31250 dsoh, ifjorZd fIyUFk ij LFkkfir djds ykbZu pkyw djus dk dk;ZA
32Mcy iksy ij 100 dsoh, ifjorZd LFkkfir djus dk dk;Z
33Mcy iksy ij 63 dsoh, ifjorZd LFkkfir djus dk dk;Z
34Mcy iksy ij 25 dsoh, ifjorZd LFkkfir djus dk dk;Z
3511 dsoh vkmVxksabZx ohlhch 200@100@5 , dUVªksy :e esa LFkkfir djus dk dk;ZA
3611 dsoh vkmVxksabZx ohlhch lhVhvkj 200@100@5 ,
3711 dsoh vkmVxksabZx ohlhch 300@150@5 ,
3811 dsoh budfeax ohlhch 600@300@5 ,
3911 dsoh ,Dl0,y0ih0bZ0 dsfcy¼3x185 mm) dks x<
4011 dsoh ,Dl0,y0ih0bZ0 dsfcy¼3x185 mm) dks x<
41fufonknkrk }kjk miyC/k djk;h tkus okyh lkexzhA
4211 dsoh dsfcy TokbZfVax fdV vkmVMksj 3.5x70 sqmm
4311 dsoh dsfcy TokbZfVax fdV buMksj 3x185 sqmm
4411 dsoh dsfcy TokbZfVax fdV vkmVMksj 3x185 sqmm
451x400 sqmm Cable for Lead
4611 dsoh ,Dl0,y0ih0bZ0 dsfcy¼3.5x70 sq mm)
4711 KV Fuse Set
48,e0,l0 psuy 125x65x1300 T-off
49VkWi psuy 125x65x3200 mm
50VkWi psuy 125x65x2240 mm
51VkWi psuy 100x50x2240 mm
52,e0,l0 ,sUxy 75x75x6x2028 mm for T/F Base
53MkWij psuy 100x50x2028 mm
54xkfMax ,Uxy 75x75x6x1600 mm
5511 dsoh X-Arm clam with nutbolt
56F-Bracket
57F-Clamp
58Holding Clamp
59Dead and Clamp with J-Hook
60Suspension Clamp with J-Hook
61I-Hook
62LT Distrubution Box 1 Phase with Clamp
63LT Distrubution Box 3 Phase with Clamp
64LT Schakle insulator
65LT Holding Clamp for PCC/STP with Nut bolt
66Stay Set Complete
67Earthing Complete
68Chemical Earthing for VCB/T.F
69GI Wire 6SWG & 10 SWG for Guarding
7024 Volt Battery and Battery Charger
71Stone Pad
72Copper Busbar
73LT XLPE Cable unarmoured 3.5x50
74LT Cable 1x240 sqmm
75Earthing Complete for VCB (Strip)
7633 KV Lightening Arrestor
7733 KV VCB with double T/F Control Penal & CT 200/100/1 A With structer
7833 KV Post insulator
79Control Cable 4x2.5 sqmm
80Control Cable 2x2.5 sqmm
81iksyks dh xzkmfVax dk dk;Z vko\";d lkexzh lfgrA
82400@250 dsoh, ifjorZd gsrq fIyUFk cukus dk dk;ZA
83400@250 dsoh, ifjorZd dh fIyUFk ds pkjksa vksj QSfUlax djusdk dk;ZA
84eqfoax VªkWyh miyC/k djkukA
85fufonknkrk }kjk miyC/k djk;h x;h lkexzh ykbZu ij vko\";drkuqlkj yxkus dk dk;ZA
8611 dsoh dsfcy TokbZfVax fdV vkmVMksj 3.5x70 sqmm
8711 dsoh dsfcy TokbZfVax fdV buMksj 3x185 sqmm
8811 dsoh dsfcy TokbZfVax fdV vkmVMksj 3x185 sqmm
891x400 sqmm Cable for Lead
9011 dsoh ,Dl0,y0ih0bZ0 dsfcy¼3.5x70 sq mm)
9111 KV Fuse Set
92,e0,l0 psuy 125x65x1300 T-off
93VkWi psuy 125x65x3200 mm
94VkWi psuy 125x65x2240 mm
95VkWi psuy 100x50x2240 mm
96MkWij psuy 100x50x2028 mm
97,e0,l0 ,sUxy 75x75x6x2028 mm for T/F Base
98xkfMax ,Uxy 75x75x6x1600 mm
9911 dsoh X-Arm Clam with nutbolt
100F-Bracket
101F-Clamp
102Holding Clamp
103Dead and Clamp with J-Hook
104Suspension Clamp with J-Hook
105I-Hook
106LT Distrubution Box 1 Phase with Clamp
107LT Distrubution Box 3 Phase with Clamp
108LT Schakle insulator
109LT Holding Clamp for PCC/STP with Nut bolt
110Stay Set Complete
111Earthing Complete
112Chemical Earthing for VCB/T.F
113GI Wire 6 SWG & 10 SWG for Guarding
11424 Volt Battery and Battery Charger
115Stone Pad
116Copper Busbar
117LT XLPE Cable unarmoured 3.5x50
118LT Cable 1x240 sqmm
119Earthing Complete for VCB (Strip)
12033 KV Lightening Arrestor
12133 KV VCB with double T/F Control Penal & CT 200/100/1 A With structer
12233 KV Post insulator
123Control Cable 4x2.5 sqmm
124Control Cable 2x2.5 sqmm
125eqfoax VªkWyh dh QSfUlax dk dk;ZA
126dk;Z LFky ls mrkjh x;h ttZj ,oa iqjkuh fo|qr lkexzh dks lqjf{kr fo|qr Hk.Mkj dsUnz esa igqpkus dk dk;ZA¼yksfMax vuyksfMax lfgr½
127100 dsoh, ifjoZrd
128250 dsoh, ifjoZrd
12911 KV VCB Scrap
13011 KV CTR Scrap
13111 KV Pin Insulator Scrap
13211 KV Disk Insulator Scrap
13311 KV X-Arm
134Channel Angle
135ACSR Dog/Weasel Conductor old & use
136LT AB Cable old & use
137Multiple Scrap
138uksV& 1- mijksDr dk;Z dz0la0 01 ls 14 rd dh ek=k iw.kZr% vuqekfur gS rFkk dksbZ Hkh dk;Z \"kwU; ls vf/kdre ¼fufonk /kujkf\"k dh lhek ds vUnj½ gks ldrk gSA2- izR;sd dk;Z dk ekiu odZ\"[email protected] dsUnz }kjk fuxZr lkexzh ds xsVikl ds vk/kkj ij fd;k tk;sxkA3- Lohd`r izkDdyu ds vUrxZr dk;Z djk;k tk;sxkA4- jsLiksa ekudksa ds vuqlkj dk;Z djk;k tk;sxkA5- mijksDr dk;Z fctusl Iyku 2023&24¼20 djksM½ esa vfrfjDr ifjorZd ,oa {kerk o`f+) ds ifjorZd yxkus ,oa vU; dk;Z gsrq fd;k tkuk gSA Lohd`r izkDdyu@ekSds LFky dh ck/;rk ds vk/kkj ij vfrfjDr dk;Z Hkh tksMs tk ldrs gS rFkk Lohd`r izkdyu ds vk/kkj ij mijksDr dk;ksaZ esa 20 izfr\"kr dh ?kVkSrjh@c

AI Tender Summary

OUR REF NO 40178721
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 10-11-2023
Authority
Authority Name Paschimanchal Vidyut Vitran Nigam Limited
Work Description Tender For In The Business Plan 2023-24 ( 20 Crores ) In Power Distribution Division-First, Baraut, For The Works Like Capacity Enhancement / Installation Of Distribution Transformers, Line Construction And Installation Of Vcb Etc. On Semi Turnkey Basis.-Pcc / Stp Pole / Converter And Other Line Material Received From Centralized Material Mandar Center Baghpat / Baraut / Meerut. Transport Work To Work Site ( Including Loading And Unloading ) - 400 Kva Converter 250 Kva Converter 100 Kva Converter 63 Kva Converter 25 Kva Converter Pcc Pole 8.5 Meter St Pole 11 Meter Acsr Weasel Conductor Asr Rabbit Conductor Ab Conductor 3X50 + 1X35 + 1X16 Sqmm Ab Conductor 3X95+1X70+1X16 Sqmm 11 Kv X0 Lpe Cable ( 3X185 Mm ) 11Kv Pin Insulator With Fittings 11 Kv Disc Insulator With Fittings 11Kv Outgoing Vcb 200 / 100 / 5A 11Kv Outgoing Vcb Ctr 200 / 100 / 5A 11Kv Outgoing Vcb 300 / 150 / 5A 11Kv Incoming Vcb 600 / 300 / 5A Pole By Digging Pit For Construction Of Dilapidated / Long Span / New Line The Act Of Installing. Pcc Pole 8.5 Meter St Pole 11 Meter Laying Of Conductors On Poles Erected For Dilapidated / Long Span / New Line Construction. A.S.S.R. Electrical Conductor Acsr Rabbit Conductor Ab0 Conductor 3X50+1X35+1X16 Sqmm Ab Conductor 3X95+1X70+1X16 Sqmm Laying Work. 11Kv Pin Insulator With Fittings Installation Work Of 11 Kv Disc Insulator With Fittings. Work Of Commissioning The Line By Installing 400 Kba Converter Trolley To Start The Line By Installing 250 Kba Converter At The Base Work . Installation Work Of 100 Kva Transformer On Double Pole Installation Work Of 63 Kva Transformer On Double Pole Installation Work Of 25 Kva Transformer On Double Pole 11Kv Outgoing Vcb 200 / 100 / 5A In Control Room The Work Of Establishing. 11Kv Outgoing Vcb Ctr 200 / 100 / 5A 11Kv Outgoing Vcb 300 / 150 / 5A 11Kv Incoming Vcb 600 / 300 / 5A The Work Of Digging A Pit For 11 Kv X-Lpe Cable ( 3X185 Mm ) And Making A Loop And Laying The Cable Till The Control Room / Double Pole. Digging Pit For 11 Kv Xlpe Cable ( 3X185 Mm ) And The Work Of Laying The Cable By Making A Loop. Materials To Be Provided By The Tenderer. 11Kv Cable Jointing Kit Outdoor 3.5X70 Sqmm 11Kv Cable Jointing Kit Indoor 3X185 Sqmm 11Kv Cable Jointing Kit Outdoor 3X185 Sqmm | 1X400 Sqmm Cable For Lead 11Kv Xlpe Cable ( 3.5X70sq.Mm ) |11 Kv Fuse Set Ms Venal 125X65x1300 T Off 2 A 125X65x3200 Mm 21 125X65x2240 Mm 2 100X50x2240 Mm Hoyo 75X75x6x2028 Mm For T / F Base Dopper Vane 100X50x2028mm Guarding Angle 75X75x6x1600mm 11 X-Arm Clam With Nutbolt F-Bracket F-Clamp Holding Clamp Dead And Clamp With J-Hook Suspension Clamp With J-Hook I-Hook Lt Distrubution Box 1 Phase With Clamp Lt Distrubution Box 3 Phase With Clamp Lt Schakle Insulator Lt Holding Clamp For Pcc / Stp With Nut Bolt Stay Set Complete Earthing Complete Chemical Earthing For Vcb / T.F Gi Wire 6Swg & 10 Swg For Guarding 24 Volt Battery And Battery Charger Stone Pad Copper Busbar Lt Xlpe Cable Unarmoured 3.5X50 Lt Cable 1X240 Sqmm Earthing Complete For Vcb ( Strip ) 33 Kv Lightening Arrestor 33 Kv Vcb With Double T / F Control Penal & Ct 200 / 100 / 1 A With Structer 33 Kv Post Insulator Control Cable 4X2.5 Sqmm Control Cable 2X2.5 Sqmm Gauting Work Of Polo Along With Necessary Materials. Work Of Making Base For 400 / 250 Kva Converter. Fencing Around The Plinth Of 400 / 250 Kva Transformer. Work . Providing Moving Trolley. Material Provided By The Bidder On Line Installation Work As Per Requirement. 11Kv Cable Splicing Kit Indoor 3X185 Sqmm 11Kv Cable Splicing Kit Outdoor 3X185 Sqmm 1X400 Sqmm Cable For Lead 11Kv Xpe Cable ( 3.5X70sq.Mm ) 11 Kv Fuse Set Ms Venal 125X65x1300 T Off 2 Al 125X65x3200 Mm 125X65x2240 Mm 21 100X50x2240 Mm Dopper Benal 100X50x2028mm Yoyo 75X75x6x2028 Mm For T / F Base If Ya 75X75x6x1600 Mm 11 Dl X-Arm Clam With Nutbolt F-Bracket F-Clamp Holding Clamp Dead And Clamp With J-Hook Suspension Clamp With J-Hook I-Hook Lt Distrubution Box 1 Phase With Clamp Lt Distrubution Box 3 Phase With Clamp Lt Schakle Insulator Lt Holding Clamp For Pcc / Stp With Nut Bolt Stay Set Complete Earthing Complete Chemical Earthing For Vcb / T.F Gi Wire 6 Swg & 10 Swg For Guarding 24 Volt Battery And Battery Charger Stone Pad Copper Busbar Lt Xlpe Cable Unarmoured 3.5X50 Lt Cable 1X240 Sqmm Earthing Complete For Vcb ( Strip ) 33 Kv Lightening Arrestor 33 Kv Vcb With Double T / F Control Penal & Ct 200 / 100 / 1 A With Structer 33 Kv Post Insulator Control Cable 4X2.5 Sqmm Control Cable 2X2.5 Sqmm Fencing Work Of Moving Trolley. Dilapidated And Old Electrical Material Removed From The Work Site The Work Of Delivering Safe Electricity To Mandar Centre. ( Loading Including Unloading ) 100 Kva Converter 250 Kva Converter |11 Kv Vcb Scrap 11 Kv Ctr Scrap | 11 Kv Pin Insulator Scrap 11 Kv Disk Insulator Scrap |11 Kv X-Arm Channel Angle Acsr Dog / Weasel Conductor Old & Use | Lt Ab Cable Old & Use Multiple Scrap
Basic Detail
Tender No 78/2023-24/EDC-BPT
Bidding Type Tender
Location
City baraut
State Uttar Pradesh
Key Dates
Publish Date 08 Nov 2023
Submission Date 10 Nov 2023
Open Date 10 Nov 2023
Finance
Tender Value Ref. Documents
Tender Fee 3540
EMD 85000
Exemption Not Available
Document List
961ef20c-4dbe-4438-896b-67141acf8ce8.html
BOQ_1429903.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 08, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 26, 2023
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 27, 2023
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 03, 2023
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 08, 2023
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 10, 2023
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 10, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 10, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

961ef20c-4dbe-4438-896b-67141acf8ce8.html

xls

BOQ_1429903.xls

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders