Tender For Construction Of Attached Toilet Block For Mahillas At Bop Katlamura In Aor Of 80 (Now 104 Bn Bsf) Bn Bsf Under Shq Bsf Teliamuera.(Sh : Iei And Service Cable Connection), Khowai-Tripura

Border Security Force-BSF has published Tender For Construction Of Attached Toilet Block For Mahillas At Bop Katlamura In Aor Of 80 (Now 104 Bn Bsf) Bn Bsf Under Shq Bsf Teliamuera.(Sh : Iei And Service Cable Connection). Submission Date for this Tender is 26-10-2023. Electrification Work Tenders in Khowai Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

40171670
Tender For Construction Of Attached Toilet Block For Mahillas At Bop Katlamura In Aor Of 80 (Now 104 Bn Bsf) Bn Bsf Under Shq Bsf Teliamuera.(Sh : Iei And Service Cable Connection)
Open Tender
Indian
Tripura
Khowai
26-10-2023

Tender Details

Construction Of Attached Toilet Block For Mahillas At Bop Katlamura In Aor Of 80 ( Now 104 Bn Bsf ) Bn Bsf Under Shq Bsf Teliamuera. ( Sh : Iei And Service Cable Connection ) ; 1 Sub-Head-Ii ( Wiring ) 2 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size M.S. Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc. Asrequired 3 Group-A 4 Wiring For Light / Power Plug With 4 X 4.0 Sq Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit Along With 2 Nos. 4.0 Sq Mm Frls Pvc Insulated Cu Conductor Single Core Cable For Loop Earthing As Required. 5 Wiring For Light / Power Plug With 2 X 4 Sq Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 6 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 7 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 8 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required 9 3 X 1.5 Sq. Mm 10 Sub-Head-Iii ( Distrubution Board ) 11 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 12 I ) 4 Way ( 4 + 12 ) , Double Door ( For Toilet Block ) 13 Supplying And Fixing 5 A To 32 A Rating 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. 14 Single Pole 15 Triple Pole And Neutral 16 Sub-Head-Iii ( Fitting And Accessories ) 17 Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. 18 Supplying And Fixing Pvc Batten / Angle Holder Including Connections Etc. As Required 19 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block I / C Connection Etc As Required. 20 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required 21 5 / 6 Amps Switch 22 3 Pin 5 / 6 A Socket Outlet 23 Providing And Fixing Of 6 Watt 6500K Led Slim Surface Mounted Led Panel With Premium Diffuser To Ensure Glare Free & Even Light Distribution Directly On Ceiling / Wall, Including Connections, Testingcomplete Etc. As Required. 24 Providing And Fixing Of 9 / 10 Watt, 6000 / 6500K Led Batten Decorative Ultra Slim Square Profile Led Lighting Fixture With Extruded Polycarbonate, Environmental Friendly, Energy Efficient Ready To Use Pack Directly On Ceiling / Wall, Including Connections, Testingcomplete Etc. As Required. 25 Supplying And Fixing Of 200 Mm Sweep, Ventilatingexhaust Fan Non-Metallicsuitable For Single Phase, 50 Hz, 230 Volts, Ac Supply In Existing Opening Including Making The Hole To Suit The Size Of Above Exhaust Fan Including Connection, Testing Etc As Required. 26 Providing And Fixing Of Heavy Duty Exhaust Fan 300 Mm, ( 900 Rpm ) ( Metal Body ) With Louvers, Fasteners Including Connection, Testing And Commissioning Etc As Reqd. 27 Supply, Installation, Testing And Commissioning Of 25 Watt Led Security Light Fittings Complete With 25 Mm Dia X 1.0 Metres Long G.I. Pipe ( Medium Class ) Directly On Ceiling / Wall, Including Connection With 1.5 Sqmm Frls Pvc Insulated Copper Condutor, Single Core Cable Etc. As Required. 28 Providing And Fixing Of Electric Storage Water Heater Of 25 Ltr, 2Kw, 4 Star Beerating, High Pressure Rating, Superior Finish Smooth Body, Installed With Fasteners With Nut, Bolts And Washers, Suitable Length Connection Pipe Including Connection, Testing Commissioning Etc As Required 29 Sub-Head-Iv- ( Earthing ) 30 Earthingwith G.I. Earth Pipe4.5Mtr Long X 40Mm Dia Including Accessories And Providing Masonary Enclosure With Cover Platehaving Locking Arrangement And Watering Pipe Etc. Withcharcoalor Coke And Salt Complete As Required. 31 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required 32 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required 33 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required 34 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Horizontal Run ) 35 Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. ( For Vertical Run ) 36 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. 37 Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required 38 Jointing Copper / G.I. Tape ( With Another Copper / G I Tape, Base Of The Finial Or Any Other Metallic Object ) By Riveting / Nut Bolting / Sweating And Soldering Etc As Required 39 Sub-Head-V ( Service Connection ) 40 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required 41 63 Mm Dia ( Od-63 Mm & Id-51 Mm Nominal ) 42 Providing, Laying And Fixing Of 40 Mm Dia Pvcpipe ( Medium Class ) For Laying Of U.G Cable Including Cutting Of Wall / Floor In Stairs And Making Goodwith Concrateand Cement After Fixing Of Pvc Pipe Etc As Required. 43 Supplying And Laying Of One No Pvc Insulated / Pvc Sheathed Xlpe Power Cable , 1.1 Kv Grade ( Heavy Duty ) , Armoured Ug Electric Cable With Aluminium Conductor Ofsize 3.5 X 35 Sqmmin The Existing Masonry / Open Duct / In Exisiting Conduit As Required. 44 Add Gst @ 18 %On Dsre-22 Instead Of 12% ( Mf = 0.0633 ) On Dsre-22 Items I.E. 82875.00 45 Add Labour Cess @ 1% On Dsre-22 Items

Key Value

Document Fees
Refer document
EMD
INR 3319.0 /-
Tender Value
INR 1.65 Lakhs /-

BOQ Items

Name of Work: C/O attached toilet Block for mahillas at BOP Katlamura in AOR of 80 (now 104 BN BSF) Bn BSF under SHQ BSF Teliamuera.(SH : IEI and Service Cable Connection)
Sl. No. Item Description
1SUB-HEAD-II(WIRING)
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required
3GROUP-A
4Wiring for light / power plug with 4 x 4.0 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit along with 2 nos. 4.0 sq mm FRLS PVC insulated Cu conductor single core cable for loop earthing as required.
5Wiring for light / power plug with 2 x 4 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit along with 1 no 4 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
72 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
8Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required
93 x 1.5 sq. mm
10SUB-HEAD-III (DISTRUBUTION BOARD)
11Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12i) 4 way (4 + 12), Double door (for Toilet Block)
13Supplying and fixing 5 A to 32 A rating 240/415 volts,"C" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.
14Single pole
15Triple pole and neutral
16SUB-HEAD-III (FITTING AND ACCESSORIES)
17Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
18Supplying and fixing PVC batten/ angle holder including connections etc. as required
19Supplying and fixing 3 pin,5 A ceiling rose on the existing junction box / wooden block i/c connection etc as required.
20Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required
215/6 amps switch
223 pin 5/6 A socket outlet
23Providing and fixing of 6 watt 6500K LED Slim surface mounted LED panel with premium diffuser to ensure glare free & even light distribution directly on ceiling/ wall, including connections, testingcomplete etc. as required.
24Providing and fixing of 9/10 Watt, 6000/6500K LED batten Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack directly on ceiling/ wall, including connections, testingcomplete etc. as required.
25Supplying and fixing of 200 mm sweep, ventilatingexhaust fan non-metallicsuitable for single phase, 50 Hz, 230 volts, AC supply in existing opening including making the hole to suit the size of above exhaust fan including connection, testing etc as required.
26Providing and fixing of Heavy Duty Exhaust fan 300 mm,(900 RPM) (Metal body) with louvers, fasteners including connection, testing and commissioning etc as reqd.
27Supply, installation, testing and commissioning of 25 watt LED security light fittings complete with 25 mm dia X 1.0 Metres long G.I. pipe (medium class) directly on ceiling/wall, including connection with 1.5 Sqmm FRLS PVC insulated copper condutor, single core cable etc. as required.
28Providing and fixing of electric storage water heater of 25 ltr, 2KW, 4 Star BEErating, high pressure rating, superior finish smooth body, installed with fasteners with nut, bolts and washers, suitable length connection pipe including connection, testing commissioning etc as required
29SUB-HEAD-IV-(EARTHING)
30Earthingwith G.I. earth pipe4.5mtr long x 40mm dia including accessories and providing masonary enclosure with cover platehaving locking arrangement and watering pipe etc. withcharcoalor coke and salt complete as required.
31Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
32Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
33Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required
34Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
35Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
36Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
37Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required
38Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required
39SUB-HEAD-V(SERVICE CONNECTION)
40Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required
4163 mm dia (OD-63 mm & ID-51 mm nominal)
42Providing, laying and fixing of 40 mm dia PVCpipe (medium class) for laying of U.G Cable including cutting of wall/ floor in stairs and making goodwith concrateand cement after fixing of PVC pipe etc as required.
43Supplying and Laying of one no PVC insulated/PVC sheathed XLPE power cable ,1.1 KV grade (heavy duty), armoured UG electric cable with aluminium conductor ofsize 3.5 x 35 sqmmin the existing masonry/open duct/in exisiting Conduit as required.
44Add GST @ 18 %on DSRE-22 Instead of 12% (MF = 0.0633) on DSRE-22 Items I.e. 82875.00
45Add Labour Cess @ 1% on DSRE-22 Items
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail