Military Engineer Services-MES has published Tender For Spl Repair/Replacement Of Summer Appliances Against Ber Under Ge E/M Lucknow. Submission Date for this Tender is 13-11-2023. Air Conditioner Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 30-Oct-2023 | Corrigendum1 | Other | 06-11-2023 |
2 | 30-Oct-2023 | Corrigendum1 | Date | 06-11-2023 |
3 | 06-Nov-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-11-2023 |
Sl. No. | Item Description |
1 | Taking down of old unserviceable . AC,s, of anytype / capacity and make from different location inlucknow cantt and deposit the old U/S AC,s in storeyard of AGE E/M complete all as specofied & directed. |
2 | Taking down of old unserviceable Deep Freezer of anycapacity and make from different location inlucknow cantt and deposit the old U/S Deep Freezer in storeyard of AGE E/M complete all as specofied & directed. |
3 | Taking down of old unserviceable desert cooler of any size capacity and make from different location inlucknow cantt and deposit the old U/S Desert Cooler in storeyard of AGE E/M complete all as specofied & directed. |
4 | Supply, installation, commissioing and testing, splitAir Conditioner of capacity 1.5 TR (Hot & Cold), Digital Inverter with inbuilt air ioniser and plasma filter, 100% copper, indoor and outdoor unit, rotary compressor, auto clean function, indoor sound level 32 db, front panel display, wireless LCD remote, precoated aluminium fins,auto fan speed,electric driven, suitable for working on 230 volts, single phase, 50 Hz supply complete including remote operationcomplete. |
5 | Quoted rates by the contractor shall be included for following item-: (a) Fixing the Indoor & outdoor unit with grouting nuts, cutting groove to wall for gas pipe & water drainage pipe. (b) S&F cutting, bent to shape copper pipe (up to 5 metre) and power cable of appropriate size from outdoor unit to indoor unit in required qty by cutting holes to wall including brazing the copper pipe fixing union including making good disturbed surfaces as existing. (c) S&F PVC pipe 20 mm dia transparent flexible heavy duty for water drainage pipe ofupto 06 RMat site. (d) Insulation of both the copper pipes with insulating material and covering the complete pipe with PVC casing & caping of size 75 x 75 mm / reqd size for mechanical protection of copper pipe complete. (e) Charging of correct qty of refrigerant gas after necessary brazing / fixing of both the outdoor / indoor unit and testing complete on load to obtain 18 degree celsius temperature at specified amps. (f) All other connected civil worklike hole cutting & other misc work reqd for installation of split AC for proper functioning as directed by EIC. (g) outdoorAC portionto be fixed on wall mounted stand as suitable forfixing of AC. (H)Plug top provided by contractor with AC wire. |
6 | Supply, installation, commissioing and testing, splitAir Conditioner of capacity 2.00 TR (Hot & Cold), Digital Inverter with inbuilt air ioniser and plasma filter, 100% copper, indoor and outdoor unit, rotary compressor, auto clean function, indoor sound level 32 db, front panel display, wireless LCD remote, precoated aluminium fins,auto fan speed,electric driven, suitable for working on 230 volts, single phase, 50 Hz supply complete including remote operationcomplete. |
7 | Quoted rates by the contractor shall be included for following item-: (a) Fixing the Indoor & outdoor unit with grouting nuts, cutting groove to wall for gas pipe & water drainage pipe. (b) S&F cutting, bent to shape copper pipe (up to 5 metre) and power cable of appropriate size from outdoor unit to indoor unit in required qty by cutting holes to wall including brazing the copper pipe fixing union including making good disturbed surfaces as existing. (c) S&F PVC pipe 20 mm dia transparent flexible heavy duty for water drainage pipe ofupto 06 RMat site. (d) Insulation of both the copper pipes with insulating material and covering the complete pipe with PVC casing & caping of size 75 x 75 mm / reqd size for mechanical protection of copper pipe complete. (e) Charging of correct qty of refrigerant gas after necessary brazing / fixing of both the outdoor / indoor unit and testing complete on load to obtain 18 degree celsius temperature at specified amps. (f) All other connected civil worklike hole cutting & other misc work reqd for installation of split AC for proper functioning as directed by EIC. (g) outdoorAC portionto be fixed on wall mounted stand as suitable forfixing of AC. (H)Plug top provided by contractor with AC wire. |
8 | Supply, installation,testing and commissioning of metal top / hard top Deep freezer of capacity 200 / 205 Ltrs single door suitable for working on 230 Volts ,SP 50 HZ Supply complete all as specified and directed. |
9 | Supply, installation,testing and commissioning of metal top / hard top Deep freezer of capacity 300 / 310 Ltrs single door suitable for working on 230 Volts ,SP 50 HZ Supply complete all as specified and directed. |
10 | Supply and installation evaporative desert coolers complete body of size 25 x 22 x 40 inch (approx) fabricated with 22 gauge plain mild steel galvanised sheet, removable side & back panel fabricated with 24 gauge plain mild steel galvanised sheet, with wood wool pads having nominal air flow capacity of 4000 cfm, having cooler fan motor with 100% copper winding of capacity 280 to 310 watt with 18” metal blade size, and submersible pump of capacity 1.5 m head, complete cooler body powder coated, with all fittings and fixtures as directed by ENG-IN- CHARGE on site completeall as specified and directed. |