Military Engineer Services-MES has published Tender For Repair/Replacement Of Unsv Wiring And Allied Works At Mil Stn Beas Under Ge Kapurthala.. Submission Date for this Tender is 09-11-2023. Electrification Work Tenders in kapurthala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

40154915
Corrigendum : Tender For Repair/Replacement Of Unsv Wiring And Allied Works At Mil Stn Beas Under Ge Kapurthala.
Open Tender
Indian
Punjab
kapurthala
09-11-2023

Tender Details

Tender For Repair / Replacement Of Unsv Wiring And Allied Works At Mil Stn Beas Under Ge Kapurthala.; 1 Taking Down Carefully Aluminium / Copper Point Wiring ( Light, Fan, Socket, Powerpoint ) Including Batten, Conduit And Fittings Such As Switches, Ceiling Rose, Sockets, Brackets, Light Fittings, Switch Board Etc, Making Good Distrubed Surfaces Of Wall, Floar, Ceiling Etc Complete All As Specified & Directed By Engr-In-Charge. 2 M&L For Point Wiring For Controlled By One Switch With Pvc Unsheathed Single Core Multistranded Copper Conductor Cable Of Size 1.5 Sqmm ( Nominal Area ) In And Including Pvc Conduit 20 Mm Dia By Cutting Chases In Walls By Cutter And Making Good The Surface In Cm1:3And To The Original Specification And Pvc Casing Capping On Ceiling For Steel Structure / Surface Conduit With Clamps, Gutties Etc For Rcc Ceiling With Including Cast Iron / Pressed Steel Terminal Boxes Including Providing New 3 Mm Thick Plastic Laminatedsheet Cover ( Hylum ) Including One Run Of Pvc Insulated Frls Copper Conductor Cable Of 1.5 Sqmm With Green Insulation As Earth Dolly Complete All As Specified And Directed By Engr-In-Charge For One Light Point Controlled By One Way Switch. 3 All As Per Ser Item No 2 But One Fan Point Controlled By One, One Way Switch 4 All As Per Ser Item No 2 But One Socket Outlet 3 Pin, 5 Amp On Independent Board 5 All As Per Ser Item No 2 But One Socket Outlet 3 Pin, 5 Amp On Same Board. 6 All As Per Ser Item No 2 Butone Bell Point Controlled By One Bell Push 7 All As Per Ser Item No 2 Butone Light Point Controlled By Two, 2 Way Switch With Cable 1.5 Sqmm Size 8 M&L For Point Wiring For Controlled By One Switch With Pvc Unsheathed Single Core Multistranded Copper Conductor Cable Of Size 2.5 Sqmm ( Nominal Area ) In And Including Pvc Conduit 20 Mm Dia By Cutting Chases In Walls By Cutter And Making Good The Surface In Cm1:3And To The Original Specification And Pvc Casing Capping On Ceiling For Steel Structure / Surface Conduit With Clamps, Gutties Etc For Rcc Ceiling With Including Cast Iron / Pressed Steel Terminal Boxes Including Providing New 3 Mm Thick Plastic Laminatedsheet Cover ( Hylum ) Including One Run Of Pvc Insulated Frls Copper Conductor Cable Of 1.5 Sqmm With Green Insulation As Earth Dolly For 6 Pin, 16 Amps Sockets Outlet On Independent Board Complete All As Specified And Directed By Engr-In-Charge. 9 All As Per Ser Item No 8 But One Socket Outlet 3 Pin, 16 Amp On Same Board. 10 S&F Switch Piano Type Policarbonate Single Pole One Way 6 Amp ( Isi Marked ) Make : Havells / Schnider / Legrand. 11 S&F Switch Piano Type Policarbonate Two Way 6 Amp ( Isi Marked ) Make : Havells / Schnider / Legrand. 12 S&F Switch Bell Push 6 Pin, 16 Amps, Flush Button Type, Polycarbonate , Sp, One Way 230 Volts. 13 S&F Switch Bell Push 6 Amps, Flush Type Polycarbonate, Sp One Way 230 Volts Including Taking Down Unservicable. Make : Havells / Schnieder / Legrand. 14 S&F Socket Out Let Multipurpose 5 Pin, 16 Amps, Flush Type, Polycarbonate, 230 / 240 Volts Including Taking Down Unservicable. Make : Havells / Schnieder / Legrand. 15 S&F Socket Out Let Multipurpose 5 Pin, 16 Amps, Flush Type, Polycarbonate, 230 / 240 Including Taking Down Unservicable Make : Havells / Schnieder / Legrand. 16 S&F Stepped Type Electroni Fan Regulator Flush Type On The Existing Phenolic Laminated Sheet Etc Complete All As Specified And Directedby Engr-In-Charge. Make : Havells / Schnieder / Legrand. 17 S&F In Replacement Of Exhaust Fan Made Of Study Engineering Plastic Complete Wih Louvers Shutter, Voltage 230V, 50Hz, Rpm 1200, Copper Winding Of Sweep 250M Complete Including Taking Down Unsv Exhaust Fan Of Any Size And Deposit To Mes Store Yard Complete All As Specified And Directedby Engr-In-Charge. 18 Taking Down Old Unservicale Holder And Supply And Fix Angular Holder Insulated Body With Back Plate Suitable For Batten Fittings Complete All As Specified And Directedby Engr-In-Charge. Make : Bajaj, Phillips / Havells / Cropton / Polycab. 19 Taking Down Old Unsv Laminated Sheet And S&F Laminated Sheet 8 X 4 Including Fix The Switch, Socket, Regulator Retrive From Old Sheet To New Laminated Sheet, Including M&L For Screws, Nuts Bolts Etc Complete All As Specified And Directedby Engr-In-Charge. 20 S&F In Repairled Bulk Head Fitting 10 Watthighly Cost Effective Compact, Ultra Low Energy, Modern Design Utility Bulkhead Suitable For Indoor And Outdoor Applications With Ip 65 Protection Cat Part No Lbh-10- Cdlof Make : Crompton Or Equivalent In Syska / Philips / Bajajwatt Complete With All Accessories And Connecting Up Complete With 3 Core Flexible Cable White Of Size 23 / 0.0076 Complete All As Specified And Directedby Engr-In-Charge. 21 Taking Down Old Us Mcb Db And S&F In Repair Sheet Metal Enclosure For Mcb Db Double Door Single Pole & Neutral 4 Way With 200 Amps Rated Bus Bar Complete All As Specified And Directedby Engr-In-Charge. Make : Legrand / L&T / Havells. 22 Taking Down Old Us Mcb Db And S & F In Repair Sheet Metal Enclosure For Mcb Db Double Door Single Pole & Neutral 8 Way With 200 Amps Rated Bus Bar Complete All As Specified And Directedby Engr-In-Charge. Make : Legrand / L&T / Havells. 23 Taking Down Old Us Mcb Db And S & F In Repair Sheet Metal Enclosure For Mcb Db Double Door Triple Pole & Neutral 4 Way With 200 Amps Rated Bus Bar Complete All As Specified And Directedby Engr-In-Charge. Make : Legrand / L&T / Havells. 24 Taking Down Old Unsv Mcb And Supply And Fixing Amp Rating 240V, 10Ka C Curve Miniature Circuit Breaker ( Mcb ) Of Following Poles And Current Carrying Capacity In The Mcb Db Complete With Connection Testing And Commissioning Complete All As Specified And Directedby Engr-In-Charge. Make : Legrand / Schneider / Siemens / C&S 25 ( I ) Sp 6 To 32 Amp ? 26 ( Ii ) Spn 32 Amp ? 27 ( Iii ) Spn 40 To 63 Amp 28 Taking Down Old Unsv Mcb Andsupply And Fixing 415V 10Ka C Curve Miniature Circuit Breaker ( Mcb ) Of Following Poles And Current Carrying Capacity In The Db Complete With Connection Testing And Commissioning Complete All As Specified And Directedby Engr-In-Charge. Make : Legrand / Schneider / Siemens / C&S 29 ( I ) Tp 25 To 63 Amp ? 30 ( Ii ) Tpn 16 To 32 Amp ? 31 ( Iii ) Tpn 40 To 100 Amp 32 Taking Down Old Unservicable Electric Energ Meter, Supply And Fix Single Phase Electronic Meter Temper Proof Lcd Display With Polycarbonate Cover 2.30 V, 10-60 Amps, Accuracy Class-I 50Hz, Conforming To Is 13779, Ip-54 With Parameters To Show Data, Time, Current Reading, Load Pf, Voltage And Kwh Complete All As Specified And Directedby Engr-In-Charge.Make : Hpl / L&T / Schneider. 33 Taking Down Old Unservicable Electric Energy Meter, Supply And Fix Single Phase Electronic Meters Temper Proof Lcd Display With Polycarbonate Cover 440V, 10-60Amps, Accuracy Class-I 50 Hz, Conforming To Is 13779, Ip -54, With Parameters To Shwo Data, Time, Current Reading, Load, Pf, Voltage And Kwh Complete All As Specified And Directedby Engr-In-Charge.Make : Hpl / L&T / Schneider. 34 Preparing Old Painted Steel Surface Of Meter Boxesof Any Size, Including Hings All Exposed Outer Surfaces Of Steel Items Fixed With The Box, Without Dismantling And M&L For Painting With One Coat Of Synthetic Enamel Paint On Exposed Steel Outer Surfaces And Writing Qtr Nos Complete All As Specified And Directedby Engr-In-Charge. 35 Taking Down Old Unservicable Sub Main Wiring And M&L For Submain Wiring With 2 Single Core Pvc Insulated Unsheathed Multi Stranded Copper Conductor Frls Wire 4.00 Sqmm 1100 Volts Grade Including And 2.50 Sqmm Pvc Insulated Multi Stranded, Unsheated Copper Wire Green In Colour As Earthing Lead Drawn Through In Pvc Rigid Conduit Of Suitable Size Complete All As Specified And Directedby Engr-In-Charge.Note:- Two Run Of 4.0 Sqmm Cable And One Run Of 2.50 Sqmm Cable As Earth Continuity Conductor Shall Be Measured & Paid As One Unit. 36 Taking Down Old Unservicable Sub Main Wiring And M&L For Submain Wiring With 2 Single Core Pvc Insulated Unsheated Multi Stranded Copper Conductor Frls Wire 6.00 Sqmm 1100 Volts Grade Including And 4 Sqmm Pvc Insulated, Multi Stranded, Unsheadted Copper Wire Green In Colour As Earthing Lead Drawn Through In Pvc Rigid Conduit Of Suitable Size Complete All As Specified And Directedby Engr-In-Charge.Note:- Two Run Of 10 Sqmm Cable And One Run Of 6 Sqmm Cable As Earth Continuity Conductor Shall Be Measured & Paid As One Unit. 37 Taking Down Old Unserviceable Sub Main Wiring And M&L For Submain Wiring With 2 Single Core Pvc Insulated Unsheathed Multi Stranded Copper Conductor Frls Wire 10 Sqmm 1100 Volts Grade Including And 6 Sqmm Pvc Insulated Multi Stranded Unsheathed Copper Wire Green In Colour As Earthing Lead Drawn Through In Pvc Rigid Conduit Of Suitable Size Complete All As Specified And Directedby Engr-In-Charge.Note:- Two Run Of 10 Sqmm Cable And One Run Of 6 Sqmm Cable As Earth Continuity Conductor Shall Be Measured & Paid As One Unit. 38 Taking Down Old Unservicable Sub Main Wiring And M&L For Submain Wiring With 4 Single Core Pvc Insulated Unsheathed Multi Stranded Copper Conductor Frls Wire 6 Sqmm 1100 Volts Grade And 6 Sqmm Pvc Insulated Multi Stranded, Unsheated Copper Wire Green In Colour As Earthing Lead Drawn Through In Pvc Rigid Conduit Of Suitable Size Complete All As Specified And Directedby Engr-In-Charge.Note:-Four Run Of 6 Sqmm Cable And One Run Of 4 Sqmm Cable As Earth Continuity Conductor Shall Be Measured & Paid As One Unit. 39 Taking Down Old Unservicable Ftl Fitting 36 / 40 Watt And S&F Surface Mounting Energy Saving Led Tube Light Fitting, 1 X 20 W, 230V, High Efficiency Pmma Diffuser Gives Soft Glare Free Light With Led Tube Rod 20W ( White ) Complete With All Accessories Complete All As Specified And Directedby Engr-In-Charge. Make : Crompton / Philips / Bajaj / Havells. 40 Taking Down Old Unservicable Ftl Fitting 36 / 40 Watt And S&F Surface Mounting Energy Saving Led Tube Light Fitting, 1 X 20 W, 230V, High Efficiency Pmma Diffuser Gives Soft Glare Free Light With Led Tube Rod 20W ( White ) Complete All As Specified And Directedby Engr-In-Charge. Make : Crompton / Philips / Bajaj / Havells. 41 Supply Down Old Unservicable Ftl Fiting 36 / 40 Watt And S&F Surface Mounting Energy Efficent Led Light Fittig 2 Feet, 1 X 20 W, 230V, Compact Batten With Extruded Aluminium Chanel Complete With All Accessories Complete All As Specified And Directedby Engr-In-Charge. Make : Havells Part No Phexarp71n1w020 42 S&F In Repair Metal Flush Mounting Box Of 6 Module Complete All As Specified And Directedby Engr-In-Charge. Make: Legrand / Siemens / Crabtree / Havells. 43 Taking Down Old Unservicable Ftl Fitting 36 / 40 Watt And S&F Surface Mounting Energy Efficient Led Light 2 Feet, 1 X 20 W 230 V, Compact Batten With Extruded Aluminium Chanel Complete With All Accessories Complete All As Specified And Directedby Engr-In-Charge. 44 S&F Wall Mounting Lights Fixture Made Up Of Polycarbonate, Suitable For 9 W Retrofit Led Lamp B22 Base Complete All As Specified And Directedby Engr-In-Charge Product Code Lhdl031600990 ( City 3 ) Of Havells Or Equivalent In Bajaj / Crompton / Polycab / Phillips . 45 M&L For Earthing Complete With Galvanized Steel Earth Plate Electrode 60 Cm X 60 Cm X 6 Mm Thick Surrounded With Charcoal And Salt, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metre Deep Below Ground Level ) With Top Edge Of Plate Not Less Than 1.5 Meter Below Normal Ground Level Connected To Galvanized Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts Check Nuts And Ashers Of Galvanized Iron Or Steel All As Shown In Electrical Plate No 3 Of Mes Ssr Part-I Connected To Main Switch Board Or Main Control Board All As Specified And Testing On Compltion Inclduing Provision Of Earth Wireprotected By Galvanized Iron 15 Mm Dia Light Grade Pipe An Watering Pipe Shall Be 20 Mm Bore Light Grade Including All Excavation And Earth Work In Any Type Of Soil Pcc Pit With Re-Cast Rcc Cover, Charcoal, Salt, Funnel Etc Complete All As Specified And Directedby Engr-In-Charge. 46 Excavation In Trenches In Soft / Loos Soil Not Exceeding 1.50 Mtr Wide And Not Excedding 1.50 Mtr In Depth For Taking Out Old Cable / Laying Of Under Ground Cable / Foundation Of Poles / Satys Including Segregation Of Old Servicable Bricks Complete All As Specified And Directedby Engr-In-Charge. 47 Returning Filling In Including Spreading Levelling Waterin And Well Ramming Inlayers Not Exceeding 25 Cm Thick Each Layer Complete All As Specified And Directed By Engr-In-Charge. 48 Removal Of Surplus Soil To A Distance Not Exceeding 50 Mtr Away And Depositing Where Directed At A Level Not Exceeding 1.5 Mtr Above The Starting Point Complete All As Specified And Directedby Engr-In-Charge. 49 M&L For Brick Protection Using Old Size Sub Class B Bricks, Laid Flat Dry But Adjoining To Each Other Laid Length Wise Prependicualr To The Exist Of Cable Complete All As Specified And Directedby Engr-In-Charge. 50 Supply Filling In Trenches Spreading, Levelling Sand Cushioning 8 Cm Below And 15 Cm Above The Cable For Under Ground Cable Complete All As Specified And Directedby Engr-In-Charge. 51 Supply And Laying In Replacement Gi Pipe Light Grade 50 Mm Bore For Cable Protection Fixed To Poles / Along Wall / Floor / Under Road / Preparation Of Gi Bracket Etc Across The Darain Or Nallah With Clamps. Bolts Nuts & Washers Etc Complete All As Specified And Directedby Engr-In-Charge Including Taking Down The Old Unservicable ( Clamps, Bolths, Nuts & Washers Shalll Be Measured And Paid Sepeartey ) . 52 S&F 1100 Volts Grade Heavy Duty Cable Pvc Insulated Stranded Aluminium Condutor, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulting Hangers Not More Than 1 Meter Aprat Including 4 Mm Suspension Wire, On Twin Core Cable Flat Or Round Of 10 Sqmm Cable Complete All As Specified And Directedby Engr-In-Charge. 53 Supply Laying Commisioning And Testing Xlple Insulated Armoured Heavy Duty, Electric Cable With Standed Conductor For Working 1100 Voltage Grade Size 2 Core 16 Sqmm Including Taking Unservicable Cable Complete All As Specified And Directedby Engr-In-Charge ( Earth Work, And Cushioning And Brick Protection Shall Be Measured And Paid For Separately ) . 54 All As Per Item Ser No 47 Above Here In Before But 4 Core 25 Sqmm 55 All As Per Item Ser No 47 Above Here In Before But 3.5 Core 35 Sqmm

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 68000.0 /-
Tender Value
INR 34 Lakhs /-

BOQ Items

Name of Work : Repair/Replacement of unsv wiring and allied works at Mil Stn Beas under GE Kapurthala.
Sl. No. Item Description
1Taking down carefully aluminium/copper point wiring (light, fan, socket, powerpoint) including batten, conduit and fittings such as switches, ceiling rose, sockets, brackets, light fittings, switch board etc, making good distrubed surfaces of wall, floar, ceiling etc complete all as specified & directed by Engr-in-Charge.
2M&L for point wiring for controlled by one switch with PVC unsheathed single core multistranded copper conductor cable of size 1.5 sqmm (nominal area) in and including PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in cm1:3and to the original specification and PVC casing capping on ceiling for steel structure/ surface conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel terminal boxes including providing new 3 mm thick plastic laminatedsheet cover(Hylum) including one run of PVC insulated FRLS copper conductor cable of 1.5 sqmm with green insulation as earth dolly complete all as specified and directed by Engr-in-Charge for one light point controlled by one way switch.
3All as per Ser item no 2 but one fan point controlled by one, one way switch
4All as per Ser item no 2 but One socket outlet 3 Pin, 5 Amp on independent board
5All as per Ser item no 2 but One socket outlet 3 Pin, 5 Amp on same board.
6All as per Ser item no 2 butOne bell point controlled by one bell push
7All as per Ser item no 2 butOne light point controlled by two,2 way switch with cable 1.5 sqmm size
8M&L for point wiring for controlled by one switch with PVC unsheathed single core multistranded copper conductor cable of size 2.5 sqmm (nominal area) in and including PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in cm1:3and to the original specification and PVC casing capping on ceiling for steel structure/ surface conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel terminal boxes including providing new 3 mm thick plastic laminatedsheet cover(Hylum) including one run of PVC insulated FRLS copper conductor cable of 1.5 sqmm with green insulation as earth dolly for 6 pin, 16 Amps sockets outlet on independent board complete all as specified and directed by Engr-in-Charge.
9All as per Ser item no 8 but One socket outlet 3 Pin, 16 Amp on same board.
10S&F switch piano type policarbonate single pole one way 6 Amp (ISI Marked) Make : Havells/Schnider/Legrand.
11S&F switch piano type policarbonate two way 6 Amp (ISI Marked) Make : Havells/Schnider/Legrand.
12S&F switch bell push 6 PIN, 16 AMPS, flush button type, polycarbonate , SP, one way 230 volts.
13S&F switch bell push 6 Amps, flush type polycarbonate, SP one way 230 volts including taking down unservicable. Make : Havells/Schnieder/Legrand.
14S&F socket out let multipurpose 5 PIN, 16 Amps, flush type, polycarbonate, 230/240 volts including taking down unservicable. Make : Havells/Schnieder/Legrand.
15S&F socket out let multipurpose 5 PIN, 16 Amps, flush type, polycarbonate, 230/240 including taking down unservicable Make : Havells/Schnieder/Legrand.
16S&F stepped type electroni fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directedby Engr-in-Charge. Make : Havells/Schnieder/ Legrand.
17S&F in replacement of exhaust fan made of study engineering plastic complete wih louvers shutter, voltage 230V, 50Hz, RPM 1200, copper winding of sweep 250m complete including taking down UNSV exhaust fan of any size and deposit to MES store yard complete all as specified and directedby Engr-in-Charge.
18Taking down old unservicale holder and supply and fix angular holder insulated body with back plate suitable for batten fittings complete all as specified and directedby Engr-in-Charge. Make : Bajaj,Phillips/Havells/Cropton/Polycab.
19Taking down old UNSV laminated sheet and S&F laminated sheet 8" x 4" including fix the switch, socket, regulator retrive from old sheet to new laminated sheet, including M&L for screws, nuts bolts etc complete all as specified and directedby Engr-in-Charge.
20S&F in repairLED Bulk head fitting 10 watthighly cost effective compact, ultra low energy, modern design utility bulkhead suitable for indoor and outdoor applications with IP 65 protection cat part No LBH-10- CDLof make : Crompton or equivalent in Syska/Philips/Bajajwatt complete with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 complete all as specified and directedby Engr-in-Charge.
21Taking down old US MCB DB and S&F in Repair sheet metal enclosure for MCB DB double door single pole & Neutral 4 way with 200 Amps rated bus bar complete all as specified and directedby Engr-in-Charge. Make : Legrand/L&T/Havells.
22Taking down old US MCB DB and S & F in Repair sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with 200 Amps rated bus bar complete all as specified and directedby Engr-in-Charge. Make : Legrand/L&T/Havells.
23Taking down old US MCB DB and S & F in Repair sheet metal enclosure for MCB DB double door Triple pole & Neutral 4 way with 200 Amps rated bus bar complete all as specified and directedby Engr-in-Charge. Make : Legrand/L&T /Havells.
24Taking down old unsv MCB and Supply and fixing amp rating 240V, 10KA "C" curve miniature circuit breaker(MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directedby Engr-in-Charge. Make : Legrand /Schneider/Siemens/C&S
25(i) SP 6 To 32 AMP ?
26(ii) SPN 32 AMP ?
27(iii) SPN 40 to 63 AMP
28Taking down old unsv MCB andSupply and fixing 415V 10KA "C" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directedby Engr-in-Charge. Make : Legrand /Schneider/ Siemens/C&S
29(i) TP 25 To 63 AMP ?
30(ii) TPN 16 To 32 AMP ?
31(iii) TPN 40 To 100 AMP
32Taking down old unservicable electric energ meter, supply and fix single phase electronic meter temper proof LCD display with polycarbonate cover 2.30 v, 10-60 Amps, ACCURACY Class-I 50HZ, conforming to IS 13779, IP-54 with parameters to show data, time, current reading, load PF, voltage and KWH complete all as specified and directedby Engr-in-Charge.Make : HPL/L&T/Schneider.
33Taking down old Unservicable electric energy meter, supply and fix single phase electronic meters temper proof LCD display with polycarbonate cover 440V, 10-60Amps, accuracy Class-I 50 Hz, conforming to IS 13779, IP -54, with parameters to shwo data, time, current reading, load, PF, voltage and KWH complete all as specified and directedby Engr-in-Charge.Make : HPL/L&T/Schneider.
34Preparing old painted steel surface of meter boxesof any size, including hings all exposed outer surfaces of steel items fixed with the box, without dismantling and M&L for painting with one coat of synthetic enamel paint on exposed steel outer surfaces and writing Qtr Nos complete all as specified and directedby Engr-in-Charge.
35Taking down old unservicable sub main wiring and M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 4.00 sqmm 1100 volts grade including and 2.50 sqmm PVC insulated multi stranded, unsheated copper wire green in colour as earthing lead drawn through in PVC rigid conduit of suitable size complete all as specified and directedby Engr-in-Charge. Note:- Two run of 4.0 sqmm cable and one run of 2.50 sqmm cable as earth continuity conductor shall be measured & paid as one unit.
36Taking down old unservicable sub main wiring and M&L for submain wiring with 2 single core PVC insulated unsheated multi stranded copper conductor FRLS wire 6.00 sqmm 1100 volts grade including and 4 sqmm PVC insulated, multi stranded, unsheadted copper wire green in colour as earthing lead drawn through in PVC rigid conduit of suitable size complete all as specified and directedby Engr-in-Charge. Note:- Two run of 10 sqmm cable and one run of 6 sqmm cable as earth continuity conductor shall be measured & paid as one unit.
37Taking down old unserviceable sub main wiring and M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 10 sqmm 1100 volts grade including and 6 sqmm PVC insulated multi stranded unsheathed copper wire green in colour as earthing lead drawn through in PVC rigid conduit of suitable size complete all as specified and directedby Engr-in-Charge. Note:- Two run of 10 sqmm cable and one run of 6 sqmm cable as earth continuity conductor shall be measured & paid as one unit.
38Taking down old unservicable sub main wiring and M&L for submain wiring with 4 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 6 sqmm 1100 volts grade and 6 sqmm PVC insulated multi stranded, unsheated copper wire green in colour as earthing lead drawn through in PVC rigid conduit of suitable size complete all as specified and directedby Engr-in-Charge. Note:-Four run of 6 sqmm cable and one run of 4 sqmm cable as earth continuity conductor shall be measured & paid as one unit.
39Taking down old unservicable FTL fitting 36/40 watt and S&F surface mounting energy saving LED tube light fitting, 1 x 20 W, 230V, high efficiency PMMA diffuser gives soft glare free light with LED tube rod 20W (White) complete with all accessories complete all as specified and directedby Engr-in-Charge. Make : Crompton/Philips/Bajaj/ Havells.
40Taking down old unservicable FTL fitting 36/40 watt and S&F surface mounting energy saving LED tube light fitting, 1 x 20 W, 230V, high efficiency PMMA diffuser gives soft glare free light with LED tube rod 20W (White) complete all as specified and directedby Engr-in-Charge. Make : Crompton/Philips/ Bajaj/Havells.
41Supply down old unservicable FTL fiting 36/40 watt and S&F surface mounting energy efficent LED light fittig 2 feet, 1 x 20 W, 230V, compact batten with extruded aluminium chanel complete with all accessories complete all as specified and directedby Engr-in-Charge. Make : Havells part No PHEXARP71N1W020
42S&F in repair Metal flush mounting box of 6 Module complete all as specified and directedby Engr-in-Charge. Make: Legrand/Siemens/Crabtree/Havells.
43Taking down old unservicable FTL fitting 36/40 watt and S&F surface mounting energy efficient LED light 2 feet, 1 x 20 W 230 V, compact batten with extruded aluminium chanel complete with all accessories complete all as specified and directedby Engr-in-Charge.
44S&F wall mounting lights fixture made up of Polycarbonate, suitable for 9 W retrofit LED lamp B22 base complete all as specified and directedby Engr-in-Charge product code LHDL031600990 (City 3) of Havells or equivalent in Bajaj/ Crompton/Polycab/Phillips .
45M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts check nuts and ashers of galvanized iron or steel all as shown in electrical plate No 3 of MES SSR part-I connected to main switch board or main control board all as specified and testing on compltion inclduing provision of earth wireprotected by galvanized iron 15 mm dia light grade pipe an watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil PCC pit with re-cast RCC cover, Charcoal, salt, funnel etc complete all as specified and directedby Engr-in-Charge.
46Excavation in trenches in soft/loos soil not exceeding 1.50 mtr wide and not excedding 1.50 mtr in depth for taking out old cable /laying of under ground cable/foundation of poles/satys including segregation of old servicable bricks complete all as specified and directedby Engr-in-Charge.
47Returning filling in including spreading levelling waterin and well ramming inlayers not exceeding 25 cm thick each layer complete all as specified and directed by Engr-in-Charge.
48Removal of surplus soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directedby Engr-in-Charge.
49M&L for brick protection using old size sub class "B" bricks, laid flat dry but adjoining to each other laid length wise prependicualr to the exist of cable complete all as specified and directedby Engr-in-Charge.
50Supply filling in trenches spreading, levelling sand cushioning 8 cm below and 15 cm above the cable for under ground cable complete all as specified and directedby Engr-in-Charge.
51Supply and laying in replacement GI pipe light grade 50 mm bore for cable protection fixed to poles/along wall/floor/under road/ preparation of GI bracket etc across the darain or nallah with clamps. Bolts nuts & washers etc complete all as specified and directedby Engr-in-Charge including taking down the old Unservicable (Clamps, Bolths, nuts & washers shalll be measured and paid sepeartey).
52S&F 1100 volts grade heavy duty cable PVC insulated stranded aluminium condutor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulting hangers not more than 1 meter aprat including 4 mm suspension wire, on twin core cable flat or round of 10 sqmm cable complete all as specified and directedby Engr-in-Charge.
53Supply laying commisioning and testing XLPLE insulated armoured heavy duty, electric cable with standed conductor for working 1100 voltage grade size 2 core 16 sqmm including taking unservicable cable complete all as specified and directedby Engr-in-Charge (Earth work, and cushioning and brick protection shall be measured and paid for separately).
54All as per item ser No 47 above here in before but 4 core 25 sqmm
55All as per item Ser No 47 above here in before but 3.5 core 35 sqmm