Tender For Special Repair To Wiring Switches Sockets And Mccb At Type Ii Md Civilian Accn And Replacement Of Apfc Provn Of Fire Alaram System At Command System Office At Hqtc (U) Bangalore, Bengaluru Urban-Karnataka

Military Engineer Services-MES has published Tender For Special Repair To Wiring Switches Sockets And Mccb At Type Ii Md Civilian Accn And Replacement Of Apfc Provn Of Fire Alaram System At Command System Office At Hqtc (U) Bangalore. Submission Date for this Tender is 16-11-2023. Electrification Work Tenders in Bengaluru Urban Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

40154478
Corrigendum : Tender For Special Repair To Wiring Switches Sockets And Mccb At Type Ii Md Civilian Accn And Replacement Of Apfc Provn Of Fire Alaram System At Command System Office At Hqtc (U) Bangalore
Open Tender
Indian
Karnataka
Bengaluru Urban
16-11-2023

Tender Details

Tender For Special Repair To Wiring Switches Sockets And Mccb At Type Ii Md Civilian Accn And Replacement Of Apfc Provn Of Fire Alaram System At Command System Office At Hqtc (U) Bangalore

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Oct-2023 DATE CHANGE Date 09-11-2023
2 28-Oct-2023 BOQ and Tender Corrigendum BOQ 09-11-2023
3 09-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 78000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : SPECIAL REPAIR TO WIRING SWITCHES SOCKETS AND MCCB AT TYPE II MD CIVILIAN ACCN AND REPLACEMENT OF APFC PROVN OF FIRE ALARAM SYSTEM AT COMMAND SYSTEM OFFICE AT HQTC (U) BANGALORE.
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring (light fan socket or power) complete including fittings & fixturessuch as switches, ceiling rose, pendants, regulators, sockets, ceiling roses,pendants, regulators, light fittings etc. Removing materials from site and making good the disturbed surfaces of walls, floors, etc. complete allas specified & as directed.
2Point wiring with cable of PVC insulated FRLS copper multistranded conductor 1.5 sqmm 1100 volts grade in and including heavy grade PVC Casing Caping Pipe ISI markedwith all accessories and fixing arrangements on wall/ceiling/floor etc.including fixing top cover /PVC junction boxes fixed on wall surfacefor housing switches/sockets/regulators etc. with and including 1.5 sqmm PVC insulated multistranded copper earth continuity conductor connecting to the common earth dolly etc complete all as specified and directed for the following :-
3One lightcontrolled by one single pole 5 Amps switch
4One Ceiling fan point controlled by one single pole 5 Amps switch
5One Exhaust fan point controlled by one wayswitch
6One 3 pin socket point 5 Amps on independent board.
7One 3 pin socket point 5 Amps on Same board.
8One Bell point controlled by one single pole 5 Amps switch
9All as per item No 2.00 here-in-before but using copper conductor 2.5 sqmm PVC insulated unsheathed FRLScable with copper conductor size 2.5 sqmmmPVC insulatedunsheathed continuous earth continuityfor 3 pin 15 amps switch socket outletindependently etc complete all as specified and directed.
10Supply and fixing of modular type fan regulator upto 300 watts with 5 step speed control for fans any sweep 1200 mm/1400 mm etc complete all as specified and directed.
11Supply and fixing PVC ceiling rose 65 x 50 mm surface type with 3 terminals etc complete all as specified and directed.
12Supply and fixing of Buzzer, Ding Dong AC. 230 volts, single pole etc complete all as specified and directed.
13Supply and fixing modular swich one way 6 Amps, 230 volts etc complete all as specified and directed.
14Supply and fixing Modular Bell push 6A 1 module etc complete all as specified and directed.
15Supply and fixing modular socket, 6 Amps 2/3 pin combined two module, 230 volts etc complete all as specified and directed.
16Supply and fixing modular socket, 6 A/16 Amps 2/3 pin combined two module, 230 volts etc complete all as specified and directed.
17Supply and fixing modular swich one way 16 Amps one module, 230 volts etc complete all as specified and directed.
18Supply and fixing modular white cover suitable with frame 1/2 module etc complete all as specified and directed.
19Supply and fixing modular white cover suitable with frame 3 module etc complete all as specified and directed.
20Supply and fixing modular white cover suitable with frame 4 module etc complete all as specified and directed.
21Supply and fixing modular white cover suitable with frame 6 module etc complete all as specified and directed.
22Supply and fixing modular metal flush board 1/2 module etc complete all as specified and directed.
23Supply and fixing modular metal flush board 3 module etc complete all as specified and directed.
24Supply and fixing modular metal flush board 4 module etc complete all as specified and directed.
25Supply and fixing modular metal flush board 6 module etc complete all as specified and directed.
26Supply and fixing LED lights fitting 4 feet, 1 x20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose etc complete all as specified and directed.
27Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed.
28Supply and fixing LED bldg street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection etc complete all as specified and directed.
29Supply and fixing of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with 9 watt LED Bulb, 220 V AC etc complete all as specified and directed.
30S & F LED light fitting 1x 9 w/1x10w bulkhead liminaries including LED light driver holder connecting up with threecore flexible copper conductor cable of suitable size etc complete all as specified and directed.
31Taking down &Refixing for geyser of50ltrs/25ltrs capacity after repairs in new position including drilling holes on wall ,fixing four Nos anchor bolts,nuts and washersand connecting to the water and electric connections and testingetc complete all as specified and directed.
32Taking down ceiling/Exhaust fan circulators, sealing cable end, dismantaling blades, and removing fan including painting andrefix the same including connecting up andprovision of cable from ceiling rose or connector to fan etc complete all as specified and directed.
33Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB for Geyer etc complete all as specified and directed.
34M&L for sub main wiring complete with 2 runs of 4.00 Sqmm PVC insulated and unsheathed cable with multistranded copper conductor confirming to IS-649, 1100 volts grade and drawn through and including PVC non metallic rigid conduits and conduit accessories concealed / run on surface of wall/floors/ ceiling etc and connecting terminal ends including1 run of 4.00Sqmm of PVC insulated unsheathedcopper conductor cable green colour as continuous earth continuity conductor and connecting to earth dolly including removing unserviceable sub main wiring complete all as directed and specified.
35Material and labour for Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground ( earth pit not less than 2.25mtrs deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level, connected to galvanised iron earth lead 4 mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indiacted including testing on completion etc complete all as specified and directed.
36Supply & fixing of Galvanised steel wire 4.00 mm Dia etc complete all as specified and directed.
37Sub main wiring with Two single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade 2.50sqmm in and including non-metallic rigid PVC casing and capping andaccessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 2.50 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note :- One run of earth continuity conductor,one run of PVC casing cappingand two run of copper conductor together taken as one length for measuring unit length.
38Supply and fixing of DB, SPN 6ways, single door type complete all as specified and as directed
39Supply and fixing 415V 10KA "C" curve miniature circuit breaker (MCB) of following poles and current carrying capacity TPN 40 To 100 AMP in the DB complete with connection testing and commissioning etc complete all as specified and directed.
40Supply & fixof MCB SP 6 to 32 Amps 240 volts 10 KA rupturing capacity etc complete all as specified and directed.
41Supply & fix MCB SPN 32 Amps 240 volts 10 KA rupturing capacity etc complete all as specified and directed.
42Supply & fix MCB TPN 40 Amps 240 volts 10 KA rupturing capacity etc complete all as specified and directed.
43Excavation in trenches not. exc. 1.5m wide and not exc. 1.5 deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
44Returning, filling in,including spreading, levelling ,watering and well ramming in layers not exc 25cm thickin soft/loose soil complete all as specified and directed by Engineer-in-Charge.
45Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting pointcomplete all as specified and directed by Engineer-in-Charge.
46Material and labour for sand cushioning to under ground cable with locally available drysand for protection of cable 8cm thick before laying of cable and 15 cm thick after laying and stretching the cable below the bricks/PCC cover ,punning of sand using suitable T&P as per site requirementcomplete all as specified and directed by Engineer-in-Charge. Note:- Punned thickness of sand to be consider for measurement purpose.
47Material & Labour for plain cement concrete 1:3:6 type C2 (using 40mm graded crushed stone aggregate)as in foundation,filling and mass concrete in foundation ofstay assembly and pole complete all as specified and directed by Engineer-in-Charge.
48Supplying and laying un-reinforced precast concrets cable cover class LV, Type 1, flat, size 250x150x40 mm complete all as specified and directed by Engineer-in-Charge.
49Supply, installation,commisioning and testing out door type factory made Capacitor bank panel made out of mild steel CRCA sheet of 3.15 mmthick with angle iron frame of size 50mm x 50mm x 6mmfor mounting and 0.5 mtr above ground level with canopy top,two side ventilators,front and back openable hinged, double door shutters with locking arrangement (including lock & key), weather & vermin proofIP 65 suitable for operation on 440 volts, 50Hz, 3 Phase 4 wire AC supply , with aluminium bus bar of size 300 amp with heat shrinkable sleeves mounted on hygroscopic insulators,all internal connection with suitable size of copper conductor cable with Lugs,Sleeves & Terminals & PVC Troughs including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces and providing necessary foundation/plateform of the Capacitor bank panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories.
50Incomming:- (a) 200 Amp 3P 36 kA MCCB TM with O/C,S/C,E/F, Rel -01 No. Make- C&S/L&T (b) Extended Rotary Handle-1 No Make- C&S/L&T. (c) Spreaders-01 Set Make- C&S/L&T
51Metering :- (d) VAF-01 No Make C&S/L&T. (e) CT"s 200/5 A CL-1 10VA -03 Nos. Make-C&S/L&T (f) 8 Stage APFC Relay -01 No. Make-C&S/L&T (g) LED Indcating Lamps R/Y/B -03 Nos. Make-C&S/L&T (h) ON/OFF Push Buttons With NO/NC ELIMENTS-08 Nos. Make- C&S/L&T (j) 6A SP MCB 10 kA "C" Curve-04 Nos. Make- C&S/L&T. (k) Auto Manual Selector Switch- 01 Nos. Make- C&S/L&T (l) Axulary contactor- 02 Nos. Make- C&S/L&T
52Outgoings:- (a) 100A TP MCCB 16 kA "C" Curve-01 Nos Make- C&S/L&T. (b) 50 kVAR Capacitor Duty Contactor -01 Nos. Make- C&S/L&T. (c) 50 kVAR Heavy Duty Capacitor-01 Nos. Make- C&S/L&T. (d) ON/OFF Push Buttons With NO/NC ELIMENTS-02 Nos Make- C&S/L&T. (e) 63A TP MCB 10 kA "C" Curve-01 Nos Make- C&S/L&T. (f) 25 kVAR Capacitor Duty Contactor-01 Nos Make- C&S/L&T. (g) 25 kVAR Heavy Duty Capacitor -01 Nos Make- C&S/L&T. (h) ON/OFF Push Buttons With NO/NC ELIMENTS-02 Nos Make- C&S/L&T (j) 32A TP MCB 10 kA "C" Curve-02 Make- C&S/L&T. (k)10 kVAR Capacitor Duty Contactor-2 No Make- C&S/L&T. (l) 10 kVAR Heavy Duty Capacitor- 02 No Make- C&S/L&T (m) ON/OFF Push Buttons With NO/NC ELIMENTS -04 Nos Make- C&S/L&T (n) 25A TP MCB 10 kA "C" Curve- 01 No Make- C&S/L&T. (o) 5 kVAR Capacitor Duty Contactor - 01 No Make- C&S/L&T. (p) 5 kVAR Heavy Duty Capacitor - 01 No Make- C&S/L&T. (q ) ON/OFF Push Buttons With NO/NC ELIMENTS -02 Nos Make- C&S/L&T
53Supply, installation,commisioning and testing out door type factory made Capacitor bank panel made out of mild steel CRCA sheet of 3.15 mmthick with angle iron frame of size 50mm x 50mm x 6mmfor mounting and 0.5 mtr above ground level with canopy top,two side ventilators,front and back openable hinged, double door shutters with locking arrangement (including lock & key), weather & vermin proofIP 65 suitable for operation on 440 volts, 50Hz, 3 Phase 4 wire AC supply , with aluminium bus bar of size 400 amp with heat shrinkable sleeves mounted on hygroscopic insulators,all internal connection with suitable size of copper conductor cable with Lugs,Sleeves & Terminals & PVC Troughs including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces and providing necessary foundation/plateform of the Capacitor bank panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories.
54Incomming:- (a) 320Amp 3P 36 kA MCCB TM based with O/C,S/C,E/F, Rel -01 No. Make- C&S/L&T (b) Extended Rotary Handle-1 No Make- C&S/L&T. (c) Spreaders-02 Set Make- C&S/L&T
55Metering :- (d) VAF-01 No Make C&S/L&T. (e) CT"s 400/5 A CL-1 5VA -03 Nos. Make-C&S/L&T (f) 10 Stage APFC Relay -01 No. Make-C&S/L&T (g) LED Indcating Lamps R/Y/B -03 Nos. Make-C&S/L&T (h) ON/OFF Push Buttons With NO/NC ELIMENTS-12 Nos Make- C&S/L&T (j) 6A SP MCB 10 kA "C" Curve-04 Nos Make- C&S/L&T. (k) Auto Manual Selector Switch- 01 Nos Make- C&S/L&T (l) Axulary contactor- 02 Nos Make- C&S/L&T
56Outgoings:- (a) 63A TP MCB 10 kA "C" Curve-04 Nos Make- C&S/L&T. (b) 25 kVAR Capacitor Duty Contactor -04 Nos Make- C&S/L&T. (c) 25 kVAR Heavy Duty Capacitor-04 Nos Make- C&S/L&T. (d) ON/OFF Push Buttons With NO/NC ELIMENTS-08 Nos Make- C&S/L&T. (e) 40A TP MCB 10 kA "C" Curve-02 Nos Make- C&S/L&T. (f) 20 kVAR Capacitor Duty Contactor-02 Nos Make- C&S/L&T. (g) 20 kVAR Heavy Duty Capacitor -02 Nos Make- C&S/L&T. (h) ON/OFF Push Buttons With NO/NC ELIMENTS-04 Nos Make- C&S/L&T (j) 32A TP MCB 10 kA "C" Curve-01 Make- C&S/L&T. (k)10 kVAR Capacitor Duty Contactor-1 No Make- C&S/L&T. (l) 10 kVAR Heavy Duty Capacitor- 01No Make- C&S/L&T (m)ON/OFF Push Buttons With NO/NC ELIMENTS -02 Nos Make- C&S/L&T (n) 25A TP MCB 10 kA "C" Curve- 01 No Make- C&S/L&T. (o) 5 kVAR Capacitor Duty Contactor - 01 No Make- C&S/L&T. (p) 5 kVAR Heavy Duty Capacitor - 01 No Make- C&S/L&T. (q ) ON/OFF Push Buttons With NO/NC ELIMENTS -02 Nos Make- C&S/L&T
57Supply, installation,commisioning and testing out door type factory made Capacitor bank panel made out of mild steel CRCA sheet of 3.15 mmthick with angle iron frame of size 50mm x 50mm x 6mmfor mounting and 0.5 mtr above ground level with canopy top,two side ventilators,front and back openable hinged, double door shutters with locking arrangement (including lock & key), weather & vermin proofIP 65 suitable for operation on 440 volts, 50Hz, 3 Phase 4 wire AC supply , with aluminium bus bar of size 600 amp with heat shrinkable sleeves mounted on hygroscopic insulators,all internal connection with suitable size of copper conductor cable with Lugs,Sleeves & Terminals & PVC Troughs including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces and providing necessary foundation/plateform of the Capacitor bank panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories.
58Incomming:- (a) 400 Amp 3P 36 kA MCCB TM based with O/C,S/C,E/F, Rel -01 No. Make- C&S/L&T (b) Extended Rotary Handle-1 No Make- C&S/L&T. (c) Spreaders-02 Set Make- C&S/L&T
59Metering :- (d) VAF-01 No Make C&S/L&T. (e) CT"s 400/5 A CL-1 10VA -03 Nos. Make-C&S/L&T (f) 10 Stage APFC Relay -01 No. Make-C&S/L&T (g) LED Indcating Lamps R/Y/B -03 Nos. Make-C&S/L&T (h) ON/OFF Push Buttons With NO/NC ELIMENTS-12 Nos Make- C&S/L&T (j) 6A SP MCB 10 kA "C" Curve-04 Nos Make- C&S/L&T. (k) Auto Manual Selector Switch- 01 Nos Make- C&S/L&T (l) Axulary contactor- 02 Nos Make- C&S/L&T
60Outgoings:- (a) 160A TP MCCB 25 kATM based with O/C,S/C,E/F, Rel -02 No. Make- C&S/L&T (b) 50 kVAR Capacitor Duty Contactor -02 Nos Make- C&S/L&T. (C) 25 kVAR Heavy Duty Capacitor-04 Nos Make- C&S/L&T. (d) ON/OFF Push Buttons With NO/NC ELIMENTS-04Nos Make- C&S/L&T. (e) 100A TP MCCB 25 kATM based with O/C,S/C,E/F, Rel -04 No. Make- C&S/L&T (f) 25 kVAR Capacitor Duty Contactor-04 Nos Make- C&S/L&T. (g) 25 kVAR Heavy Duty Capacitor -02 Nos Make- C&S/L&T. (h) ON/OFF Push Buttons With NO/NC ELIMENTS-04 Nos Make- C&S/L&T (j) 63A TP MCCB 25 kATM based with O/C,S/C,E/F, Rel -01 No. Make- C&S/L&T (k)20 kVAR Capacitor Duty Contactor-01 No Make- C&S/L&T. (l) 20 kVAR Heavy Duty Capacitor -01 Nos Make- C&S/L&T. (m) ON/OFF Push Buttons With NO/NC ELIMENTS -02 Nos Make- C&S/L&T (n) 40A TP MCB 10 kA "C" Curve- 01 No Make- C&S/L&T. (o) 15 kVAR Capacitor Duty Contactor - 01 No Make- C&S/L&T. (p) 15 kVAR Heavy Duty Capacitor -02 Nos Make- C&S/L&T. (q) ON/OFF Push Buttons With NO/NC ELIMENTS -02 Nos Make- C&S/L&T (r) 32A TP MCB 10 kA "C" Curve- 01 No Make- C&S/L&T. (s) 5 kVAR Capacitor Duty Contactor - 01 No Make- C&S/L&T. (t) 5 kVAR Heavy Duty Capacitor -01 Nos Make- C&S/L&T. (u) ON/OFF Push Buttons With NO/NC ELIMENTS -02 Nos Make- C&S/L&T
61Supply, installation,commisioning and testing out door type factory made Capacitor bank panel made out of mild steel CRCA sheet of 3.15 mmthick with angle iron frame of size 50mm x 50mm x 6mmfor mounting and 0.5 mtr above ground level with canopy top,two side ventilators,front and back openable hinged, double door shutters with locking arrangement (including lock & key), weather & vermin proofIP 65 suitable for operation on 440 volts, 50Hz, 3 Phase 4 wire AC supply , with aluminium bus bar of size 600 amp with heat shrinkable sleeves mounted on hygroscopic insulators,all internal connection with suitable size of copper conductor cable with Lugs,Sleeves & Terminals & PVC Troughs including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces and providing necessary foundation/plateform of the Capacitor bank panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories.
62Incomming:- (a)630Amp 3P 50 kA MCCB TM based with O/C,S/C,E/F, Rel -01 No. Make- C&S/L&T (b) Extended Rotary Handle-1 No Make- C&S/L&T. (c) Spreaders-02 Set Make- C&S/L&T
63Metering :- (d) VAF-01 No Make C&S/L&T. (e) CT"s630/5 A CL-1 10VA -03 Nos. Make-C&S/L&T (f) 12 Stage APFC Relay -01 No. Make-C&S/L&T (g) LED Indcating Lamps R/Y/B -03 Nos. Make-C&S/L&T (h) ON/OFF Push Buttons With NO/NC ELIMENTS-12 Nos Make- C&S/L&T (j) 6A SP MCB 10 kA "C" Curve-04 Nos Make- C&S/L&T. (k) Auto Manual Selector Switch- 01 Nos Make- C&S/L&T (l) Axulary contactor- 02 Nos Make- C&S/L&T
64Outgoings:- (a) 160A TP MCCB 25 kATM based with O/C,S/C,E/F, Rel -03 No. Make- C&S/L&T (b) 50 kVAR Capacitor Duty Contactor -03 Nos Make- C&S/L&T. (c) 50 kVAR Heavy Duty Capacitor -03 Nos Make- C&S/L&T. (d) ON/OFF Push Buttons With NO/NC ELIMENTS-06Nos Make- C&S/L&T. (e) 100A TP MCCB 25 kATM based with O/C,S/C,E/F, Rel -04 No. Make- C&S/L&T (f) 25 kVAR Capacitor Duty Contactor-04 Nos Make- C&S/L&T. (g) 25 kVAR Heavy Duty Capacitor -04 Nos Make- C&S/L&T. (h) ON/OFF Push Buttons With NO/NC ELIMENTS-08 Nos Make- C&S/L&T (j) 63A TP MCCB 25 kATM based with O/C,S/C,E/F, Rel -01 No. Make- C&S/L&T (k)20 kVAR Capacitor Duty Contactor-01 No Make- C&S/L&T. (l) 20 kVAR Heavy Duty Capacitor -01 Nos Make- C&S/L&T. (m) ON/OFF Push Buttons With NO/NC ELIMENTS -02 Nos Make- C&S/L&T (n) 40A TP MCB 10 kA "C" Curve- 01 No Make- C&S/L&T. (o) 15 kVAR Capacitor Duty Contactor - 01 No Make- C&S/L&T. (p) 15 kVAR Heavy Duty Capacitor-01 Nos Make- C&S/L&T. (q) ON/OFF Push Buttons With NO/NC ELIMENTS -02 Nos Make- C&S/L&T (r) 32A TP MCB 10 kA "C" Curve- 01 No Make- C&S/L&T. (s)10 kVAR Capacitor Duty Contactor - 01 No Make- C&S/L&T. (t) 10 kVAR Heavy Duty Capacitor -01 Nos Make- C&S/L&T. (u) ON/OFF Push Buttons With NO/NC ELIMENTS -02 Nos Make- C&S/L&T (v) 32A TP MCB 10 kA "C" Curve- 01 No Make- C&S/L&T. (w) 5 kVAR Capacitor Duty Contactor - 01 No Make- C&S/L&T. (x) 5 kVAR Heavy Duty Capacitor -01 Nos Make- C&S/L&T. (y) ON/OFF Push Buttons With NO/NC ELIMENTS -02 Nos Make- C&S/L&T
65Taking out unserviceable cable any type/size from trenches,pole, road,duct etc including necessary joints,U/S fittingsandpipes etc complete all as specified and directed.
66Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armouredheavy duty electric cable 1100V grade with aluminum conductor of cross sectional area95 sqmm 3.5 core complete all as specified and directed .
67Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armouredheavy duty electric cable 1100V grade with aluminum conductor of cross sectional area120 sqmm 3.5 core complete all as specified and directed .
68Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armouredheavy duty electric cable 1100V grade with aluminum conductor of cross sectional area185 sqmm 3.5 core complete all as specified and directed .
69Disconnecting and taking out old rusted pipe and material and labour for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including Flat Iron clamps - 02 Nos of size 50x6mm, with nut bolt and washers complete all as specified & directed by Engineer-in-Charge.
70Material and labour for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including Flat Iron clamps-02 Nos of size 50x6mm, with nut bolt and washers including disconnecting and taking out old rusted pipe etc complete all as specified & directed by Engineer-in-Charge.
71M& L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4mpa working pressure complete all as specified & directed by Engineer-in-Charge.
72Material and labour for earthing complete with galvanized steel earth plate electrode of size600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip of size 32mm X 6mm main earthing lead by means of galvanized bolts, nuts, washers and brazed properlyall as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board,LT panel etc with & including adequate quantity of charcoal dust and common salt around earth plate, PCC 1:3:6 type C-1 using 20mm gradedstone aggregate for earth pit with pre cast RCC (1:2:4)type B-1 using 20mm graded stone aggregate 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh,and 40 mm dia GI light grade earth lead protection pipe, completeall as specified & directed by Engineer-in-Charge. Note:- The unit rate includes main earthing leadGI earth strip of size 32x6 mm with 40 mm dia GI light grade earth lead protection pipe from earth electrode to test point up to 7.5 mtr.
73Supply and fix Addressable manual call point resettable type completeall as specified & directed by Engineer-in-Charge.
74Supply and fix Remote response indicators
75Supply and fix 1.5 sqmm, 2 core flexible armoured copper cable for fire detectors comminication completeall as specified & directed by Engineer-in-Charge.
76Detectors Complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination completeall as specified & directed by Engineer-in-Charge.
77M&L for connecting the new fire system with existing panel duly configrated to suitable to communicate and re-alligned to that loop etc completeall as specified & directed by Engineer-in-Charge.
78M&L for welding of earthing with exothermic kit in copper strip of sizes upto 25x3.0mm at places where joints are made with nuts bolts to achive good connectivity
79M&L for welding of earthing with MS welding rods in GI strip of sizes upto 32x6.0mm at places where joints are made with nuts, bolts to achive good connectivity