| 1 | Foundation excavation in Earth work in hard soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the department etc. complete.etc. complete as per direction of Engg-in-Charge |
| 2 | Range Officer Quarterr Quarter |
| 3 | Boundary Wall |
| 4 | Filling foundation and plinth with sand and well watered and rammed including cost, conveyance and royalty etc complete asper direction of Engg.-in-Charge |
| 5 | Range Officer Quarter |
| 6 | Boundary Wall |
| 7 | Cement concrete (1:4:8)with 40mm size CBHG metal including cost, conveyance and royalty etc. completeas per direction of Engg.-in-Charge |
| 8 | Range Officer Quarter |
| 9 | Boundary Wall |
| 10 | Fly Ash Brick masonry in c.m. 1:6 in F & Pincluding cost,conveyance and royalty of materials curing etc. complete. as per the direction of the Engineer-in-charge |
| 11 | Range Officer Quarter |
| 12 | Boundary Wall |
| 13 | 1st class Fly Ash brick masonry workin superstructure thoroughly soaked in water, withcement mortar (1:6) including scaffoldings ,racking out joints, curing etc complete as per specification/drawing and as per the direction of the Engineer-in-charge |
| 14 | Range Officer Quarter |
| 15 | Boundary Wall |
| 16 | Providing and Laying reinforcement Cement concrete (M-20) with 20 mm and down graded chips including cost all materials,labours,T & P,curing etc complete (excluding the cost of reinforcement & Centering, shuttering) as per direction of Engineer-in-charge. |
| 17 | Column Base |
| 18 | Plinth Beam |
| 19 | Beam & Column |
| 20 | 65mm avg. chajja |
| 21 | Roof Slab |
| 22 | Lintel |
| 23 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete in proper position including cost of binding wire 18 to 20 gauge as per direction of Engg.-in-Charge. |
| 24 | Range Officer Quarter |
| 25 | 12mm cement plaster in cement mortar (1:6)including necessary scaffolding curing etc. as per direction of Engg.-in-Charge. |
| 26 | Range Officer Quarter |
| 27 | 16mm thick cement plaster in cement mortar (1:6) including necessary scaffolding curing etc. as per direction of Engg.-in-Charge |
| 28 | Range Officer Quarter |
| 29 | Boundary Wall |
| 30 | 6mm.thick cement plaster with C.M(1:4) to RCC surface including closed deep chipping and slury treatment etc. complete as per direction of Engg.-in-Charge. |
| 31 | Fixing colour Vitrifiedtiles in floors (Printed Series)of size 600mm x600 mm of approved make conforming IS:13755 laid on 20 mm thick cement mortar (1:4)and filling joints with white cement of approved qualityincluding cost of all materials, labour T&P etc rrequired for the work all completeas per direction of Engineer-in-charge. |
| 32 | Fixing Vitrifiedtiles in dados (Printed Series)skirting and risers of stepson 12 mm thick cement plaster(1:3) jointed with neat cement slurry mixed with pigments to matche shade of the tiles including rubbing and polishing completeasper direction of Engineer-in-charge. |
| 33 | Cement washing one coats with cost of all labour & materials etc. complete as per direction of Engg-in-Charge |
| 34 | Range Officer Quarter |
| 35 | (boundry wall) |
| 36 | Wall Priming onecoats on new work with wall water bound primer ofapproved shadeas per direction of Engg-in-Charge |
| 37 | Range Officer Quarter |
| 38 | Boundary Wall |
| 39 | Wall painting two coatson new work with Distemper of approved shade etc. complete as per direction of Engg-in-Charge. |
| 40 | Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T & P etc. complete as per direction of Engg-in-Charge . |
| 41 | Wall painting two coats on new work with Weather coat paint ofapproved shade as per direction of Engg.-in-Charge |
| 42 | Range Officer Quarter |
| 43 | Boundary Wall |
| 44 | Supplying and fixing of steel M.S. grill with all fitting and fixtures including cost of cutting holes in the brick masonry and R.C.C. columns and making good to damage etc, as per direction of Engineer -in -charge |
| 45 | Range Officer Quarter |
| 46 | Boundary Wall |
| 47 | Eamel Painting two coats with enamel paint over one coat of primer of approved quality etc. complete as per direction of Engg-in-Charge . |
| 48 | 20mm. thick gradingplaster in c.m. 1:4 over roof slab and chujjaincluding cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge |
| 49 | Fixing Floor tiles in floors,treads or steps and landings on 25 mm thick CM (1:1) jointed with neat cement slurry mixed with pigments to match the shades includind cost for rubbing, polishing & cost of marbel tiles etc. completeas per direction of Engg-in-Charge |
| 50 | Fixing Ceramic Glazed wall tiles in dados skirting and risers of stepson 12 mm thick cement plaster(1:3) jointed with neat cement slurry mixed with pigments to matche shade of the tiles including rubbing and polishing completeasper direction of Engineer-in-charge. |
| 51 | 25mm PVC Door Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement , including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer’s specification and direction of Engineer-in-charge. |
| 52 | Signages & contigency |
| 53 | ELECTRICAL Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front modular cover of suitable size , MS modular box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex / L&T / Anchor / Havels / V Guard ) |
| 54 | Group-A |
| 55 | Group-B |
| 56 | Group-C |
| 57 | Supplying and fixing of following MODULAR type Bell pushon the existing switch box / cover including connections etc as required. as per direction of Engineer in Charge. ( Make of wire Finolex / L&T / Anchor / Havels / V Guard ) |
| 58 | Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor o f ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard) |
| 59 | Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard) |
| 60 | Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard) |
| 61 | Recessed wiring to submain in 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard) |
| 62 | Recessed wiring to Supply and fixing of01 no.sof 3pin 5/6 amp modular socket and S.P. 5/6 amp one way modular switch, 1 no. of 5 pin 15/16 socket out let and S.P. 15/16 A one way modular switch on Modular G.I. Box with Modular Base and cover. .(Make of wire Finolex/L&T/Anchor/Havels/V Guard) |
| 63 | Supply and fixing of 3 pin 6Amp plugwith 6Amp switch on existing board (Modulartype ).(Make of wire Finolex/L&T/Anchor/Havels/V Guard) |
| 64 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 03 no.s of 6 pin 5/6 & 01 no. of 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.(Make of wireFinolex/L&T/ Anchor/ Havels/V Guard) |
| 65 | Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required (Make of wireFinolex/L&T/ Anchor/ Havels/V Guard) |
| 66 | Supply and fixing of following way single pole and neutral, sheet steel, MCB distribution board consumer unit, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic covr for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB / RCCB / Isolator)6 WAY (8 + 18) DOUBLE DOOR, HORIZONTAL TYPE |
| 67 | Supply and fixing of 5Amp to 32A rating 240V \"B/C\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. as required.(make-HPL/ Havells/ Legrand /L&T/C&S) |
| 68 | Copper Earth Plate electrodeSupply and fixing of copper plate earthing( 600 X 600 X 3.15mm )with running copper flat 25 X 5mm from copper plate to funnel of40mm dia G.I pipe including all accessories etc. as required.(make-HPL/ Havells/ Legrand /L&T/C&S) |
| 69 | Salt / charcoal for pipe earth electrodeCopper Earth Plate electrodeExtra for using salt and charcoal for G.I or copper pipe earth elctrrode as required.(make-HPL/ Havells/ Legrand /L&T/C&S) |
| 70 | S/F of 1200mm High Speed Ceiling fan Alluminium Body, Copper winding, High speed ceiling fan (Make-Crompton Model-Riviera High Speed, Polycab Model-Vital, Polar Model-Winpro) etc |
| 71 | S/F of 8\" PLASTIC VENTILLATING FAN exhaust fan (Make-Crompton Model-Jura, Polycab Model-Vital, Polar Model-Winpro) etc. |
| 72 | S/Fof 1x18 Watt LED T-5 fitting(Make-Crompton/Philips/Havells/Bajaj) |
| 73 | S/Fof 60 W LED Street light fitting(Make-Crompton/Philips/Havells/Bajaj) |
| 74 | MV cable laying up to 25 sq.mm on surfaceLaying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size notexceeding 25 sq.mmon surface as required. |
| 75 | S/F TP MCB ISOLATOR - 100 AmpSupply and fixing of following rating four pole 415 V isolator in the existing MCB DB ISI marked complete with connection testing and commissioning etc. as required. |
| 76 | S/F OF MCCB IN CUBICAL PANEL BOARD-100A 10KSupply and fixing of 4 pole MCCB 100 A,10KA breaking capacity in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required. |
| 77 | S/F OF MAIN SWITCHES ISI Marked-100Amp TPNSupply, Installation, Testing, and Commissioning of 100 Amp TPN Main switches of following capacity (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links, interconnections, earthing, etc. as required as per direction of Engineer in Charge.Make- SEIMENS/HPL/ANCHOR/L&T/HAVELS/C & S/ RK |
| 78 | Providing and fixing M.V danger board of 250 mm x 200 mm made mild steel at least 2 mm thick and vitreous enameled white on both sides and with inscription in single red colours on front side as requred. |
| 79 | S/F of 20 Watt LED Square surface mountfitting (Make-Havells/Philips/C&S/Crompton) as requred. |
| 80 | PHD&SanitationCutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc all complete as per Engg.-in- charge.250mm wall |
| 81 | Cutting holes in R.C.C floors and roos upto 19cm thick for passing G.I/P.V.C pipes and fitting etc. and prepairing the holes after insertion of pipe etc. with cement concrete 1:2:4 including finishing complete so as to make it leak proof as per Engg.-in- charge. |
| 82 | Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification etc complete as per Engg.-in- charge. |
| 83 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste and rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes complete as per direction of Engineer-in-Charge |
| 84 | 75mm OD P.V.C. SWR S/S Pipe (ISI type-A) |
| 85 | 90mm OD P.V.C. SWR S/S Pipe (ISI type-A)(for rain water) |
| 86 | 110mm OD P.V.C. SWR S/S Pipe (ISI type-A) |
| 87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge |
| 88 | 20mm dia pipe |
| 89 | 25mm dia pipe |
| 90 | Providing and fixing on wall face unplasticised-PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansios etc complete as per direction of Engineer-in-Charge |
| 91 | A) PVC SWR couplerI)75 mm dia PVC SWR coupler |
| 92 | ii)90 mm dia PVC SWR coupler |
| 93 | iii) 110 mm dia PVC SWR coupler |
| 94 | B) Single tee with doorI) 75 x 75 x 75mm dia PVC SWR Tee |
| 95 | ii) 90 x 90 x 90mm dia PVC SWR Tee |
| 96 | iii)110 x 110 x 110mm dia PVC SWR Tee |
| 97 | C) SWR Plain Bend 87.5°i) 75mm diaP.V.C. SWR plain bend 87.5 |
| 98 | ii) 90mm diaP.V.C. SWR plain bend 87.5 |
| 99 | iii) 110mm diaP.V.C. SWR plain bend 87.5 |
| 100 | D) SWR PlainDoor Bend 87.5°i) 75mm diaP.V.C. SWR plain bend 87.5 |
| 101 | ii) 90mm diaP.V.C. SWR plain bend 87.5 |
| 102 | iii) 110mm diaP.V.C. SWR plain bend 87.5 |
| 103 | Fixing 100mm size ‘P’ or ‘S’ trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification. etc complete as per direction of Engineer-in-Charge |
| 104 | (i) \"P\" trap (with horn or without horn) |
| 105 | (ii) ‘S’trap (with horn or without horn) |
| 106 | Fixing water closet, squatting pan (Indian type W.C pan) conforming to IS 2556 : Part 3-2004 duly embedded in cement concrete (1:4:8) using hard granite metal 4cm nominal size all complete as per specification alletc. complete as per direction of Engg. in charge. |
| 107 | Fixing wash down water closet (Europian type WC ) with integral\"S\" and \"P\" trap to the floor with wooden plug and chromum plated screw including jointing the trap including Seat cover alletc. complete as per direction of Engg. in charge. |
| 108 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixersetc. completeas per direction of Engg. in charge. |
| 109 | FixingWash Basinwith hole for pillar type with cast iron or M S bracket painted white including cutting holes in the walls and making good the damagesetc. complete as per direction of Engg. in charge.For Wash RoomPorcelain Counter Top Basin Oval Shape (550x430) |
| 110 | FixingWash Basinwith hole for pillar type with cast iron or M S bracket painted white including cutting holes in the walls and making good the damagesetc. complete as per direction of Engg. in charge.Porcelain 22\"x 16\"(550x400) W.H.B |
| 111 | Fixing bowl pattern urinal conforming to IS 2556 : Part 6-1996 including connecting the urinal of 430x260x350 mm or 340x410x265 mm sizes respectively with waste pipe by means of white lead mixed with chopped hemp etc all complete as per specification.etc. complete as per direction of Engg. in chargePorcelain Flat back stall type magnum Urinal |
| 112 | Fixing glazed earthenware squatting plate of size 600mm x 350mm conforming to IS:2556- Part-6-1995 with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:4:8) using 40mm hard granite metal all complete as per specification etc. complete as per direction of Engg. in charge.One-seated Urinal 1m x 0.50m x 0.15m size |
| 113 | Fixing PVC waste pipe of following nominal diameter for wash basin or sink including brass check nut complete as per specificationetc. complete as per direction of Engg. in charge. |
| 114 | Fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin complete as per specificationetc. complete as per direction of Engg. in charge. |
| 115 | Fixing of Brass Screw-down Bib Cocks (Taps) polished bright conforming to IS:781-1995 of the following nominal sizes as per specificationetc. complete as per direction of Engg. in charge. |
| 116 | i) 15mm Short Body Bib Cock |
| 117 | ii) 15mm Long Body Bib Cock |
| 118 | Fixing of Brass Screw-down Angle/Counseales stop cock Cocks polished bright conforming to IS:781-1995 of the following nominal sizes as per specificationetc. complete as per direction of Engg. in charge. |
| 119 | i) 15mm dia CP Brass Angle Stop Cock |
| 120 | ii) 20mm dia CP Brass Concealed Stop Cock |
| 121 | Fixing of Brass 15mm dia CP flange of the following nominal sizes as per specificationetc. complete as per direction of Engg. in charge.i) 15mm dia CP flange |
| 122 | Fixing Bib Cock capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of the following nominal bore as per specificationetc. complete as per direction of Engg. in charge. |
| 123 | i) 15mm dia C.P. Pillar cock with swinging spout |
| 124 | ii) C.P.revolving shower (bend type) |
| 125 | iii) CP Health Foucet with 1.0 mtr PVC Tube |
| 126 | Fixing 600mm x 450mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as per specificationetc. complete as per direction of Engg. in charge.i) 600mm x 450mm bevelled edge mirror |
| 127 | Fixing standard sized glass-shelf with Chromium Plated brass brackets and guard rails complete, fixed to woden plugs with Chromium Plated brass screws as per specification complete as per direction of Engg. in charge.i) C.P. glass self with glass |
| 128 | Fixing standard sized Chromium Plated brass towel rail complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per specification. complete as per direction of Engg. in charge.i) C.P. towel rail.(600x20)mm |
| 129 | Fixing (a) Liquid Soap Container – Glass container or Plastic container with Chromium Plated brass lid and brackets fixed to wooden plugs with Chromium Plated brass screws or (b) Chromium Plated brass soap dish complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws or (c) white glazed tooth brush holder fixed to wooden plugs with Chromium Plated brass screws as per specification complete as per direction of Engg. in charge.i) C.P Soap holder/disc. |
| 130 | Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification complete as per direction of Engg. in charge. |
| 131 | 2000 litre capacity Double Layer Cylinderical Vertical water storage tanks |
| 132 | Supply , fitting and fixing of following fixers including all materials and labours etc all complete as per specification complete as per direction of Engg. in charge. |
| 133 | i) 450x450mm Square Man Hole Cover -16.0 kg |
| 134 | ii) 90mm dia P.V.C. Nahani Trap |
| 135 | iii) 110mm dia PVC SWR Single Y with door |
| 136 | iv) PVC SWR Jalli 110mm dia |
| 137 | v) 110 mm dia P.V.C. SWR Vent Cowl |
| 138 | vi) UPVC BALL VALVE Sch-80 (Solvent Welded with Metal Ball)a) 25mm dia |