Madhyanchal Vidut Vitran Nigam Limited has published Increasing Capacity Of 33/11 Kv Sub Station Bairampur Barwan From 1X10 Mva To 10+5 Mva Distt Akbarpur (Ambedkarnagar). Submission Date for this Tender is 16-10-2023. Electrification Work Tenders in Ambedkar Nagar Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40122820
Increasing Capacity Of 33/11 Kv Sub Station Bairampur Barwan From 1X10 Mva To 10+5 Mva Distt Akbarpur (Ambedkarnagar)
Open Tender
Indian
Uttar Pradesh
Ambedkar Nagar
16-10-2023

Tender Details

Increasing Capacity Of 33 / 11 Kv Sub Station Bairampur Barwan From 1X10 Mva To 10+5 Mva Distt Akbarpur ( Ambedkarnagar ) - 1 Safeloading, Carriage And Then Safeunloading Of The Following Material From Store Centres Under The Jurisdiction Of Eeesd Ayodhaya To Dump Site Proper Stacking. 2 33 Kv Bus Isolator 3 33 Kv Post Insulator 4 33 Kv Lightening Arrestor 5 90 Lbs Rail Pcs For T / F ( 44.64 Kg / M ) 6 33 Kv Vcb 800A, 750 Mva 7 Singe T / F Control Pannel 8 C.T. O / D 33 Kv Ctr 200 / 100 / 1-1A 9 11 Kv Incoming Switch Gear 600 / 300 / 5A, 350 Mva 10 11 Kv Out Going Switch Gear 200 / 100 / 5A0250mva 11 11 Kv 3 Core Cable 3X300 Mm Xlpe 12 11 Kv Cable 3X185 Sq. Mm Xlpe 13 11 Kv Cable Jointing Kit Indoor 3X300 Sq.Mm. Xlpe 14 11 Kv Cable Jointing Kit Outdoor 3X300 Sq.Mm. Xlpe 15 11 Kv Cable Jointing Kit Indoor 3X185 Sq.Mm. Xlpe 16 11 Kv Cable Jointing Kit Outdoor 3X 185 Sq.Mm. Xlpe 17 Acsr Dog Conductor 18 M.S. Channel 125X65 ( For Structures ) 19 M.S. Angle 75X75x8 ( For Structures ) 20 24 Volt Battery& Battery Charger 21 St Pole 11Mtr 22 M.S.Angle Iron 65X65x6 Bracing 2700 Mm 23 11 Kv Top Channel 100X50x2240 Mm 24 11 Kv Disc Insulator T&C Type 25 11 Kv Polymer Pin Insulator 26 Stay Wire 7 / 10 27 6 Swgwire 28 Plinth Of 5Mva, 33 / 11 Kv T / Fsconstruction Of Plinth Of Size 3.46X3.46 Mtr For5 Mva T / F Having 0.4 Mtr Above Ground Level. The Work Includes Excavation Of Foundation, Base Concreting In C.C. 1:6:12 Ratio ( Cement, Fine Sand And Brick Ballast ) 1St Class Bricks Work In Cement Mortar Of Ratio 1:4 Foundation, C.C. In 1:4:8 Ratio ( Cement, Fine Sand And Brick Ballast ) And Rcc Working Ratio 1:2:4 ( Cement, Coarse Sand And Stone Grit Of 20 Mm Gauge ) Using Ms Bars Of 10 Mm Dia ( Tor ) In Reinforcement Including Its Cutting, Bending And Binding In Required Shape. The Work Also Includes Laying Of 2 Nos. 3.46 Mts Long Each Rail Pieces Complete With Cutting, Welding And Proper Fitting Etc. The Plinth Will Be Made As Per Drawing And Shall Be Plastered / Finished On Top And Side Of The Plinth. ( All The Material Will Be Supplied By The Contractor Except Rail Piece ) 29 Bus Isolator Structurefabrication Of Isolator Structures 3.5Mtr In Height As Per Drawing No. Res 39 Digging Of Two Nos. Pits Of Size 1.075 X 0.9 X0.3 Mtr Providing Stone Pad At The Bottom Of The Pit And Grouting Pad At The Bottom Of The Pit And Grouting Of Two Legs Of The Isolator Structure In Cc ( Cement, Coarse Sand And Stone Grit Of 20 Mm Gauge ) Of Ratio 1:4:8 In Block Of 1.075 Mtx 0.3 Mtr Including Supply Of All T&P Complete In All Respect. The Work Includes Dragging, Shifting Upto 40 Mtr. Raising And Erecting The Two Legs With Runner Of Isolator In Proper Allingment Level And Plumb. Plinths Of The Isolator Structure Shall Be Properly Finished With Champering Of Edges. ( All The Material Will Be Supplied By The Contractor Like M.S Flat Etc. Except Steel ) 30 Lightening Arrestor / Post Insulator Structurefabrication Of 1 No Lightening Arrestor Structure& 1 Set Of Post Insulatorstructure Per Drawing No. Res 39 Digging Of Two Nos. Pits Of Size 1.075 X 0.3 X0.3 Mtr Providing Stone Pad At The Bottom Of The Pit And Grouting Of Two Legs Of The Above Structure In Cc ( Cement, Coarse Sand And Stone Grit Of 20 Mm Gauge ) Of Ratio 1:4:8 In Block Of 1.075 Mtr X 0.3 Mtr X 0.3 Mtr Including Supply Of All T&P Complete In All Respect. The Work Includes Dragging, Shifting Upto 40 Mtr. Raising And Erecting The Two Legs With Top Frame Above StructureS In Properallingment Level And Plumb. Plinths Of All The Structure Shall Be Properly Finished With Champering Of Edges Etc. ( All The Material Will Be Supplied By The Contractor . Except Steel ) 31 Fabricatin Of Ctstructure Fabrication Of Ct Structure As Per Drawing No. Res 39 Digging Of Two Nos. Pits Of Size 1.075 X 0.3 X0.3 Mtr Providing Stone Pad At The Bottom Of The Pit And Grouting Of Two Legs Of The Above Structure In Cc ( Cement, Coarse Sand And Stone Grit Of 20 Mm Gauge ) Of Ratio 1:4:8 In Block Of 1.075 Mtr X 0.3 Mtr X 0.3 Mtr Including Supply Of All T&P Complete In All Respect. The Work Includes Dragging, Shifting Upto 40 Mtr. Raising And Erecting The Two Legs With Top Frame Above StructureS In Properallignment Level And Plumb. Plinths Of All The Structure Shall Be Properly Finished With Champering Of Edges Etc. ( All The Material Will Be Supplied By The Contractor Except Steel Section ) 32 Plinth For 33Kv Vcbconstruction Of Plinth Of Size 2.0X1.5X0.9 ( Mtr ) Suitable For Erection Of Super Structure For 33 Kvvcb Including Grouting Of Anchor Bolts In Proper Allingment And Level. Scope Of Work Includes Excavation Of Foundation Base Concreting In Cc 1:6:12 ( Cement, Fine Sand And Brick Ballast ) 1St Class Brick Work In Cement Mortor Of Ratio 1:4 Cc In Ratio 1:4:8 And Rcc Work In Ratio 1:2:4 ( Cement, Coarse Sand And Stone Grit Of 20 Mm Gauge ) As Per Drawing 33 H.T. Cable Layinglaying & Dressing Of 11 Kv, 3X300 And 3X185 Sq.Mm Xlpe Cable Underground From 5 Mva T / F To 11 Kv Incoming Switchgear In The Trench 450Mm Wide, 900Mm Deep, Providing 150Mm Fine Sand Cushion Bench And 150Mm Fine Sand Cushion Above The Cable. The Cable Shall Be Duly Protected By 1St Class Bricks Two Either Side And Third On Top Of The Cables, Laid In Series One After The Other, The Work Includes Supplying Offine Sand And Bricks, Refillingand Rammingof The Left Out Soil, Closing The Trench And Leveling. Spare Cable Shall Be Left And Buried In The Trench In The Safe Of Rings At Both Ends. Cable Laying Work Includes Unrolling, Cutting, Meggering And Sealing Both End Of The Cable. ( All The Material Will Be Supplied By The Contractor ) 34 Erection And Installation Of 33 / 11 Kv 5 Mva Transformerdragging Of 33 / 11Kv 5Mva T / F From Dump Site To Road Site And Shifting Of The T / F From Road Site To New Constructed Plinth Distance About 150Mtr , Along With Loading, Unloading And Carriage, Fixing And Fitting Of All The Accessiories And Filling Of T / F Oil To The Desired Level And Insuring That There Is No Leakage. Erection And Installation Of 33 / 11 Kv, 5 Mva Transformer In A Leveled Position On The Plinth. 35 Installation Of Bus Isolators Assembling And Installation Of Bus Isolator On The Isolator Structure , Adjusting Of Opening Mechanism In Proper Alignment So As To Ensured Smooth Operation Of The Same. In Case Of Line Isolator Proper Operation Of Earth Links Shall Also Be Ensured. The Work Includes Fabrication For Proper Fixing If Required. 36 Installation Of Post Insulator Installation Of Post Insulator On The Post Insulator Structure . The Work Includes Fabrication For Proper Fixing If Required. 37 Installation Of Lightening Arrestorsassembling And Installation / Mounting Of Lightening Arrestors On The L.A. Structure / Complete With Making Earth Connection ( Separate ) And Line Connections. The Work Includes Fabrication For Proper Fixing If Required. 38 Installation Of 33 Kv Vcbinstallation Of 33 Kv 750 Mva 800 Amp Vcb On 33 Kv Vcb Structure Along With Earthing By G.I. Strip 50X6 Mm Size With Main Earthmat Of Switchyards Complete In All Respect Including Commissioning. 39 Shifting Carefully And Installation Ofsingle / Double Transformer Control Pannel In Control Roomand Its Proper Connection. 40 Installation Of Ct Installation Of Cts Of Ratio 200 / 100 / 1Aon The Cts Structure. The Work Includes Fabrication For Proper Fixing If Required. 41 Installation Of Switchgears In Control Roomshifting Carefully And Safely 11 Kv Incomingswitchgear, 11 Kv Outgoing Switchgear And 11 Kv Bus Coupler From Out Side Of The Switch Gear Room, As Per Direction Of Engineer Incharge, Placing And Fixing Of Switchgear On Foundation Providing Nuts & Bolt Of Proper Size In Proper Position And Alignment And Mountting Of P.T. On Incoming S / G. 42 Installation Of Heat Shrinkable Type Cable Jointing Kits Indoor And O / D End Termination And S / T Joint Suitable For 11Kv Xlpe Cable Confirming To Is Esi-09-13-Is-13573 Of 1992 Amendment I&Ii Vde-0278 Of Latest Version There Of If Any. 43 Cable Stand Structurefabrication & Erection Of 11 Kv Cable Stand Made Of 02 No. M.S Chanel 125X65x6 Mm 3 Mtr. Jointed To Each Other By M.S Channel Horizontally And Also Jointed To Each Other By Means Of 05 No. M.S Strip ( M.S Flat ) 50X6 Mm Of Size 200 Mm Long Each By Welding At Actual Distance Interval As Per Norms. And Grouting In Block Of 300X300x700 Completely Providing 02 No. Cable Clamps Also And Eathing By G.I Strip 50X6 Mm Size With The Earth Mat Of Switchyard Both Side Of Legs And Provideing Clamps , Post / Pin Insulator For Holding Cable. ( All The Materials Will Be Arranged By The Contractor Such That Clamps Nut Bolts And Civil Materials Except M.S Channel. ) 44 Neutral Standfabrication And Grouting Of M.S Channel 125X65 Mm L Shape & In Proper Size And Allignment To Provide Support For The Two Separate Earthing Strips For Pwer T / F Neutral Including Supply & Fixing Of Two No.Flexible Copper Bonds For Neutral Earthing. ( All The Materials Will Be Arranged By The Contractor Such That Clamps Nut Bolts And Civil Materials Except M.S Channel. ) 45 Construction Of 11 Kv Double Poleerection & Grouting Of 2 Nos 11Mtr Stp Support For Making Dp Structure Including Fabrication, Fixing Of Ms Channel, M.S. Angle, Disc Insulators / Pin Insulators Etc. The Work Includes Suply And Fixing Of Necessary Clamp With Nut, Boltsand Washers. Complete In All Respect. ( All The Material Will Be Supplied By The Contractor Except Steel Section ) 46 Provding, Fixing And Mounting Of Following Equipments ( All The Material Will Be Supplied By The Contractor ) 47 11 Kv Tpmo Switch With Fixing Clamps. 48 11 Kv Fuse Set With Fixing Clamps 49 Grouting Of Following Structure By Digging Of Pit 1.83 Mtr Deep For 11 Mtr Stp, With 1:4:8 Ratio Cement, Sand & First Class Brickballast0.285 Cu Mtr For 11 Mtr Stp, Plinthing 0.3 Mtr Above G / L And Proper Plastering. 50 Providing And Fixing Of Earth Rod For Earthing Of Support By G.I. Wire 6 Swg As Per Norms. ( All Materialwill Be Arranged By The Contractorlike Earth Rod Except 6 Swg Wire. 51 Painting Of Structurepainting Of 11 Mtr St Pole With One Coat Of Ready Mixed Primer And 2 Coats Of Al.Paint Of Good Quality Including Cost Of Material, Labour And T&P Complete In All Respect. 52 Nozeling And Grouting Of Stay Set. ( All The Civil Material And Stay Set Will Be Arranged By The Contractor Except Stay Wire ) 53 Supply & Laying Of 6X2.5 Sq.Mm. Sq. Control Cable From Power T / F To Controle Board In The Ground As Per Respo Norm With Proper Connection Vcb, Ct & Control Pannel With T / F To Battery And Battrey Charger, Bucholz Relay, Low Higher And Winding Temperture Protection Alarm Etc With Including All The Civil Material. ( All The Material Will Be Supplied By The Contractor ) 54 Supply & Laying Of 4X2.5 Sq.Mm. Sq. Control Cable From Power T / F To Controle Board In The Ground As Per Respo Norm With Proper Connection Vcb, Ct & Control Pannel With T / F To Battery And Battrey Charger, Bucholz Relay, Low Higher And Winding Temperture Protection Alarm Etc With Including All The Civil Material. ( All The Material Will Be Supplied By The Contractor ) 55 Supply & Laying Of 2X2.5 Sq.Mm. Sq. Control Cable From Power T / F To Controle Board In The Ground As Per Respo Norm With Proper Connection Vcb, Ct & Control Pannel With T / F To Battery And Battrey Charger, Bucholz Relay, Low Higher And Winding Temperture Protection Alarm Etc With Including All The Civil Material. ( All The Material Will Be Supplied By The Contractor ) 56 Special Earthing By Way Of Boring And Lowering Of B Class G.I. Pipe 50 Mm Dia 20Mtr Longfrom Ground Upto The Water Level Andit Will Be Connected To The G.I. Strip 50X6 Mm ( Providing & Laying Of G.S. Strip Including Cutting, Welding, Bending Etc. ) For Equipments ( L.A, T / F, C.T., Vcb.Etc ) . The Earth Strip Will Be Welded To The G.I. Pipe. The Work Also Includes Cap & Clamps For Pouring Water, The Cost Of All Material With All Labour & T&P Etc. Complete In All Respect. ( All The Material Will Be Supplied By The Contractor ) 57 Commissioning Of 5 Mva T / F And Its Eqipments Installed In Switchyards And 11 Kv Incoming And Outgoing Pannels Complete In All Respect Upto Energising 58 Providing Of Rubber Matting One Side Chequered And Other Side Plane Size 1900X800x12 Mm 59 Providing Of Hand Gloves As Per Is 4770 And Tested Potential 33 Kv. 60 Painting Ofall Switchyard Sub Station Structures ( Old+New+Fencing ) With One Coat Of Ready Mixed Primer And 2 Coats Of Al.Paint Of Good Quality Including Cost Of Material, Labour And T&P Complete In All Respect. 61 Installation Of 24 Volt Battery ( 210 Ah ) & Battery Charger With Cabinet. With Its Proper Connection. ( Cabinet Shall Be Provided By The Contractor ) 62 Hosting Of 11 Kv Cable On Existing / Erected Support With Provision Of Ms Pipe 150 Mm Dia 3 Mtr Long Suitable For 3X185 Sq Mm Cable Fixing Of Proper Support And Its Clamping , Providing Long Barral Lugs 6 Nos And P.G. Clamps & Y Shapejumpering Properly And 02 Nos. Supporting Angle 65X65x6, 2800 Mm As Per Resspo Norms. ( All Material Will Be Supplied By The Contractor Like Ms Pipe , P.G. Clamps, Al. Lug And Supporting Angle 65X65x6, 2800 Mm ) . 63 Digging And Locating The Earth Mat And Outdoor Structures Earthing By G.I Flat. 50X6 Mm The Job Include Cutting, Bending. ( All The Material Will Be Supplied By The Contractor. ) 64 Fixing And Making Bus Bar Connection In Between I / C And O / Gswitchgears After Cleaning And Tapping With H.T. Tape, Empire Tape And Pvc Tape Properly Providing And Fixing Of 6Mm Thick Bakelite Seperators And Plugging Of All Opening And Holes With Plastic Compound. Complete Work Including Cost Of All Materialstrictly To The Satisfaction Of Site Incharge. 65 33 Kv Bay Bus Bar & Stringing.Stringing Of 33Kv Bay Bus Bar By Using And Laying Of Acsr Dog Conductor Including Making Vertical / Horizontal ( Y-Shape ) Jumperconnection Through Pg Clamps And Connecting All The Equipments ( Bus Isolator, P.I. , C.T. , Vcb, L.A & T / F ) With Each Other Through Connecting Clamps. ( All The Material Will Be Supplied By The Contractor ) 66 Breaking The Concrete Fencing / Boundary Wall In The Switchyard Of Sub. Station For Moving 10 Mva Transformer In Switchyard After Complition Ofthe Covered Workand Restore The Wall / Fencing. 67 Earthing Of All Indoor Equipment By Providing And Laying G.S. Strip 50 X 6 Mm Including Cutting, Welding, Bending Etc. By Digging And Inserting The 04 Electrode ( G.I Pipe Of Size 2.5 Mtr Long 40 Mm Dia ) Inside The Earth And Distance Among Them Will Be 03 Mtr. And The Arrangement Will Be In The Sqaure Shape Manner And Then Connect The Electrode With One Another With G.S Strip 35X6 And Then Digging And Locating The Earth Mat And Connect The Electrode By 35X6 G.S Strip ( The Above Arrangement Will Be 02 No. ) By Using 35X6 G.S Strip, 11 Kv Switchgear Earthing Must Be Connect To The Arrangement. 68 Providing And Fixing Of P.G Clamp For Dog And Connector 69 Providing And Fixing Of Copper L. Piece On Top Of Bushing Of Transformers

Key Value

Document Fees
INR 3540 /-
EMD
INR 12800.0 /-
Tender Value
INR 12.78 Lakhs /-

BOQ Items

Name of Work:INCREASING CAPACITY OF 33/11 KV SUB STATION BAIRAMPUR BARWAN FROM 1x10 MVA TO 10+5 MVA DISTT AKBARPUR (AMBEDKARNAGAR)
Sl. No. Item Description
1SafeLoading, Carriage and then safeunloading of the following material from Store Centres Under the jurisdiction of EEESD Ayodhaya to dump site proper stacking.
233 KV Bus Isolator
333 KV Post Insulator
433 KV Lightening Arrestor
590 lbs rail Pcs for T/F ( 44.64 Kg/m)
633 KV VCB 800A, 750 MVA
7Singe T/F control pannel
8C.T. O/D 33 KV CTR 200/100/1-1A
911 KV Incoming switch gear 600/300/5A, 350 MVA
1011 KV Out going switch gear 200/100/5A0250MVA
1111 KV 3 Core Cable 3x300 mm XLPE
1211 KV Cable 3x185 sq. mm XLPE
1311 KV cable jointing kit indoor 3x300 sq.mm. XLPE
1411 KV cable jointing kit outdoor 3x300 sq.mm. XLPE
1511 KV cable jointing kit indoor 3x185 sq.mm. XLPE
1611 KV cable jointing kit outdoor 3x 185 sq.mm. XLPE
17ACSR Dog Conductor
18M.S. Channel 125x65 (for Structures)
19M.S. Angle 75x75x8 (for Structures)
2024 Volt Battery& Battery charger
21ST Pole 11Mtr
22M.S.Angle iron 65x65x6 bracing 2700 mm
2311 KV Top channel 100X50X2240 mm
2411 KV disc insulator T&C type
2511 KV Polymer pin insulator
26Stay wire 7/10
276 SWGWire
28Plinth of 5MVA, 33/11 KV T/Fs Construction of Plinth of size 3.46x3.46 Mtr for5 MVA T/F having 0.4 Mtr above ground level. The work includes Excavation of foundation, Base concreting in C.C. 1:6:12 ratio ( cement,fine sand and Brick ballast) 1ST Class bricks work in cement mortar of ratio 1:4 foundation, C.C. in 1:4:8 ratio( cement, fine sand and brick ballast) and RCC working ratio 1:2:4 ( cement, coarse sand and stone grit of 20 mm gauge) using MS Bars of 10 mm Dia (Tor) in reinforcement including its cutting, bending and binding in required shape. The work also includes laying of 2 Nos. 3.46 mts long each rail pieces complete with cutting, welding and proper fitting etc. The plinth will be made as per Drawing and shall be plastered/ finished on Top and Side of the plinth. (All the material will be supplied by the Contractor except rail Piece)
29Bus Isolator Structure Fabrication of isolator structures 3.5mtr in height as per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x 0.9 x0.3 Mtr providing stone pad at the bottom of the pit and grouting pad at the bottom of the pit and grouting of two legs of the isolator structure in CC ( cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 mtX 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with runner of isolator in proper allingment level and plumb. Plinths of the Isolator structure shall be properly finished with champering of edges.(All the material will be supplied by the Contractor like M.S Flat etc. except steel)
30Lightening Arrestor/ Post Insulator Structure Fabrication of 1 No Lightening Arrestor structure& 1 set of Post Insulatorstructure per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x 0.3 x0.3 Mtr providing stone pad at the bottom of the pit and grouting of two legs of the above structure in CC ( cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 Mtr X 0.3 Mtr x 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with Top frame above structure"s in properallingment level and plumb. Plinths of all the structure shall be properly finished with champering of edges etc.(All the material will be supplied by the Contractor . except steel)
31Fabricatin Of CTStructure Fabrication of CT Structure as per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x 0.3 x0.3 Mtr providing stone pad at the bottom of the pit and grouting of two legs of the above structure in CC ( cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 Mtr X 0.3 Mtr x 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with Top frame above structure"s in properallignment level and plumb. Plinths of all the structure shall be properly finished with champering of edges etc. (All the material will be supplied by the contractor except Steel Section)
32Plinth for 33KV VCB Construction of plinth of size 2.0x1.5x0.9 (Mtr) suitable for erection of super structure for 33 KvVCB including grouting of Anchor bolts in proper allingment and level. Scope of work includes excavation of foundation base concreting in CC 1:6:12( cement, fine sand and brick ballast) 1st class brick work in cement mortor of ratio 1:4 CC in Ratio 1:4:8 and RCC work in ratio 1:2:4 ( Cement, coarse sand and stone grit of 20 mm gauge) as per Drawing
33H.T. Cable Laying Laying & dressing of 11 KV, 3x300 and 3X185 Sq.mm XLPE cable underground from 5 MVA T/F to 11 KV incoming switchgear in the trench 450mm wide, 900mm deep, providing 150mm fine sand cushion bench and 150mm fine sand cushion above the cable. The cable shall be duly protected by 1st class bricks two either side and third on top of the cables, laid in series one after the other, the work includes supplying offine sand and bricks, refillingand rammingof the left out soil, closing the trench and leveling. Spare cable shall be left and buried in the trench in the safe of rings at both ends. Cable laying work includes unrolling, cutting, meggering and sealing both end of the cable.(All the material will be supplied by the contractor)
34Erection and Installation of 33/11 KV 5 MVA Transformer Dragging of 33/11KV 5MVA T/F from Dump site to road site and shifting of the T/F from road site to new constructed plinth distance about 150mtr ,along with loading, unloading and carriage, fixing and fitting of all the accessiories and filling of T/F oil to the desired level and insuring that there is no leakage. Erection and installation of 33/11 Kv, 5 MVA Transformer in a leveled position on the plinth.
35Installation of Bus Isolators Assembling and installation of Bus isolator on the Isolator structure , adjusting of opening mechanism in proper alignment so as to ensured smooth operation of the same. In case of line Isolator proper operation of earth links shall also be ensured. The work includes fabrication for proper fixing if required.
36Installation of Post Insulator Installation of post insulator on the post insulator structure . The work includes fabrication for proper fixing if required.
37Installation of Lightening Arrestors Assembling and installation/ mounting of Lightening Arrestors on the L.A. structure/ complete with making earth connection ( Separate ) and line connections. The work includes fabrication for proper fixing if required.
38Installation of 33 KV VCB Installation of 33 KV 750 MVA 800 Amp VCB on 33 KV VCB structure along with earthing by G.I. strip 50x6 mm size with main earthmat of Switchyards complete in all respect including commissioning.
39Shifting carefully and installation ofSingle/double Transformer Control pannel in control roomand its proper connection.
40Installation Of CT Installation of CTs of ratio 200/100/1Aon the CTs structure. The work includes fabrication for proper fixing if required.
41Installation of Switchgears in Control room Shifting carefully and safely 11 Kv incomingSwitchgear, 11 KV outgoing Switchgear and 11 KV Bus Coupler from out side of the switch gear room, as per direction of Engineer Incharge, Placing and fixing of switchgear on foundation providing nuts & bolt of proper size in proper position and alignment and mountting of P.T. on incoming S/G.
42Installation of Heat Shrinkable Type cable jointing kits indoor and O/D end Termination and S/T Joint suitable for 11KV XLPE cable confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any.
43Cable stand Structure Fabrication & erection of 11 KV Cable Stand made of 02 No. M.S chanel 125x65x6 mm 3 Mtr. Jointed to each other by M.S Channel horizontally and also jointed to each other by means of 05 No. M.S Strip (m.s flat) 50x6 mm of size 200 mm long each by welding at actual distance interval as per norms. And grouting in block of 300x300x700 completely providing 02 no. cable clamps also and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs and provideing clamps , post/ pin insulator for holding cable. (All the materials will be arranged by the contractor such that clamps nut bolts and civil materials except M.S channel.)
44Neutral stand Fabrication and grouting of M.S Channel 125x65 mm L shape & in proper size and allignment to provide support for the two separate earthing strips for pwer T/F neutral including supply & fixing of two No.Flexible copper bonds for neutral earthing. (All the materials will be arranged by the contractor such that clamps nut bolts and civil materials except M.S channel.)
45Construction of 11 KV Double pole Erection & Grouting of 2 Nos 11Mtr STP support for making DP structure Including fabrication, Fixing of MS Channel, M.S. angle,Disc Insulators/ Pin Insulators etc. The work Includes suply and fixing of necessary clamp with nut, boltsand washers. complete in all respect.(All the material will be supplied by the contractor except steel section)
46Provding, fixing and mounting of following equipments(All the material will be supplied by the contractor)
4711 KV TPMO switch with fixing clamps.
4811 KV Fuse set with fixing clamps
49Grouting of following structure by digging of pit 1.83 Mtr deep for 11 Mtr STP,with 1:4:8 Ratio cement, sand & first class brickballast0.285 cu mtr for 11 mtr STP, plinthing 0.3 Mtr above G/L and proper plastering.
50Providing and fixing of earth rod for earthing of support by G.I. Wire 6 SWG as per norms. (All materialwill be arranged by the contractorLike earth rod except 6 swg wire.
51Painting of Structure Painting of 11 Mtr ST Pole with one coat of ready mixed primer and 2 coats of AL.Paint of good quality including cost of material, Labour and T&P complete in all respect.
52Nozeling and grouting of stay set. (All the civil material and stay set will be arranged by the contractor except Stay wire)
53Supply & Laying of 6x2.5 sq.mm. Sq. control cable from power T/F to controle board in the ground as per RESPO Norm with proper connection VCB, CT & Control Pannel with T/F to battery and battrey charger, Bucholz Relay, low higher and winding temperture protection alarm etc with including all the civil material. (All the material will be supplied by the contractor)
54Supply & Laying of 4x2.5 sq.mm. Sq. control cable from power T/F to controle board in the ground as per RESPO Norm with proper connection VCB, CT & Control Pannel with T/F to battery and battrey charger, Bucholz Relay, low higher and winding temperture protection alarm etc with including all the civil material. (All the material will be supplied by the contractor)
55Supply & Laying of 2x2.5 sq.mm. Sq. control cable from power T/F to controle board in the ground as per RESPO Norm with proper connection VCB, CT & Control Pannel with T/F to battery and battrey charger, Bucholz Relay, low higher and winding temperture protection alarm etc with including all the civil material. (All the material will be supplied by the contractor)
56Special Earthing by way of boring and lowering of "B" class G.I. pipe 50 mm Dia 20mtr longfrom ground upto the water level andit will be connected to the G.I. strip 50X6 mm ( Providing & laying of G.S. strip including cutting, welding, bending etc.) for equipments(L.A,T/F,C.T., VCB.etc). The earth strip will be welded to the G.I. Pipe. The work also includes Cap & Clamps for pouring water, the cost of all material with all labour & T&P etc. Complete in all respect. (All the material will be supplied by the contractor)
57Commissioning of 5 MVA T/F and its eqipments installed in switchyards and 11 KV Incoming and Outgoing Pannels complete in all respect upto energising
58Providing of Rubber matting one side chequered and other side plane size 1900x800x12 mm
59providing of Hand gloves As per IS 4770 and tested potential 33 Kv.
60Painting ofAll Switchyard Sub Station Structures (Old+New+fencing) with one coat of ready mixed primer and 2 coats of AL.Paint of good quality including cost of material, Labour and T&P complete in all respect.
61Installation of 24 Volt Battery(210 AH) & Battery charger with cabinet. With its proper connection.(Cabinet shall be provided by the contractor)
62Hosting of 11 KV Cable on existing/erected support with provision of MS Pipe 150 mm dia 3 mtr long suitable for 3x185 sq mm cable fixing of proper support and its clamping , providing long barral lugs 6 nos and P.G. Clamps & "Y" shapejumpering properly and 02 nos. supporting angle 65X65X6, 2800 mm as per RESSPO Norms. (All material will be supplied by the contractor like MS Pipe , P.G. Clamps, Al. Lug And Supporting Angle 65X65X6, 2800 mm).
63Digging and locating the earth mat and outdoor Structures earthing by G.I Flat. 50X6 mm the job include cutting, bending. (All the material will be supplied by the contractor.)
64Fixing and making Bus Bar connection in between I/C and O/Gswitchgears after cleaning and tapping with H.T. tape, Empire tape and PVC tape properly providing and fixing of 6mm thick bakelite seperators and plugging of all opening and holes with plastic compound. complete work including cost of all materialStrictly to the satisfaction of site incharge.
6533 KV Bay Bus Bar & Stringing. Stringing of 33KV Bay Bus Bar by using and laying of ACSR Dog Conductor including making Vertical/Horizontal (Y-shape) jumperconnection through PG clamps and connecting all the equipments ( Bus isolator, P.I. , C.T. , VCB, L.A & T/F) with each other through connecting clamps.(All the material will be supplied by the contractor)
66Breaking the concrete fencing/ Boundary wall in the switchyard of sub. Station for moving 10 MVA Transformer in switchyard after complition ofthe covered workand restore the wall /fencing.
67Earthing of all indoor equipment by providing and laying G.S. strip 50 x 6 mm including cutting, welding, bending etc. By digging and inserting the 04 electrode( G.I pipe of size 2.5 mtr long 40 mm dia) inside the earth and distance among them will be 03 mtr. and the arrangement will be in the sqaure shape manner and then connect the electrode with one another with G.S Strip 35x6 and then digging and locating the earth mat and connect the electrode by 35x6 G.S strip ( The above arrangement will be 02 No.) By using 35x6 G.S strip,11 KV switchgear earthing must be connect to the arrangement.
68Providing and fixing of P.G clamp for dog and connector
69Providing and fixing of Copper L. Piece ON TOP OF bushing of transformers