| 1 | Supply of S.T. Pole (SP-55) 11.0 Mtr. (Bottom Galvanized) |
| 2 | Supply of3x300 Sq.mm 33 kV XLPE Cable (FR-LSH) |
| 3 | Supply of 33 kV 3x300 Sq.mm O/D Cable Box |
| 4 | Supply of33 kV Straight through cable box 3x300 Sq.mm XLPE |
| 5 | Supply ofEarth Rod 20mm dia. and 2540mm long with Complete accessories |
| 6 | Supply of Earth wire 7/16 SWG |
| 7 | Supply ofGalvanized M.S. Channel 100x50x6 mm |
| 8 | Supply ofGalvanized M.S. Angle 65x65x6 mm |
| 9 | Supply ofGalvanized MS Flat |
| 10 | G.I. Barbed wire |
| 11 | Supply ofDanger Board with clamp |
| 12 | Supply of33KV Bus Isolator with Galvanized structure and all accessories |
| 13 | Supply of33KV Line Isolator with Galvanized structure and all accessories |
| 14 | Supply ofH.T. Para Tape |
| 15 | Supply of Galvanized MS Clamp 7½ (50x8 mm) |
| 16 | Supply of Galvanized C.I. Packing 7½ |
| 17 | Supply of Galvanized MS Clamp 6½ (50x8 mm) |
| 18 | Supply of Galvanized C.I. Packing 6½ |
| 19 | Supply of Galvanized MS Clamp 5½ (50x8 mm) |
| 20 | Supply of GalvanizedC.I. Packing 5½ |
| 21 | Supply of 33 KV Pin with Nut. |
| 22 | Supply of 33 KV Pin Insulator. |
| 23 | Supply of ACSR Dog Conductor |
| 24 | Supply ofG.I. Pipe 6\" dia Length 3 meter each. |
| 25 | Supply of Galvanized MS Pipe 200 mm dia |
| 26 | Supply ofHDPE Pipe 160 mm dia |
| 27 | Supply ofLT Bracket 18\" |
| 28 | Supply of Long barrel Al. Lug 300 Sq.mm |
| 29 | Supply ofGalvanized Nut and Bolt with Off Size Washer |
| 30 | Loading, Carriage and unloading of poles from Contractor\"s store to work site or from one site to another site |
| 31 | Erection of Double pole structure with all related accessories |
| 32 | Grouting of pole with cement brick ballast and coarse sand as per standard specification of UPPCL/KESCo |
| 33 | Making plinth of single pole of 500 mm dia, 600 mm height (200mm underground) with C.C. in ratio 1:4:8 of cements, stone ballast and coarse sand including cost of materials. |
| 34 | Painting of S.T. pole with one coat of red oxide and two coats of Aluminium Paintincluding cost of Ist Class enamel paint. |
| 35 | Earthing of supports by burying the M.S. earthing rod of 20mm dia. (2540mm long) and connecting with earth wire and related works as per standard specifications. |
| 36 | Loading, Carriage and unloadingof 33/11 kV XLPE 3x300 Sq.mm cable fromcontractor\"s store and safely taking out from cable drumat work site (including all related work) |
| 37 | Digging of Trench for laying of 33KV cable at different locations in size of 30 cm. wide and 1 to 1.5 meter deep (In Normal soil) |
| 38 | Digging of Trench for laying of 33KV cable at different locations in size of 30 cm. wide and 1 to 1.5 meter deep. (In Kharanja Soil) |
| 39 | Digging of Trench for laying of 33KV cable at different locations in size of 30 cm. wide and 1 to 1.5 meter deep. (In Metallic Road) |
| 40 | Laying of 33 KVXLPE cable in above digged trench covering with bricks, sand and back filling & proper ramming upto the ground level along with marking using stone pads of proper size as approved by KESCo. |
| 41 | Laying of Cable by HDD method without Pipe |
| 42 | Laying of Cable by HDD Method with HDPE Pipe |
| 43 | Laying of MS Pipe in digged trench |
| 44 | Laying of Cable in MS Pipe |
| 45 | Fabrication/Modification of MS Items as per requirement of site |
| 46 | Fixing of MS Channel (100x50x6 )mm 2.4 / 2.8 mtr. Long/M.S. Angleand as per site requirement |
| 47 | Fixing of danger board on erected poles |
| 48 | Making outdoor/indoor joints of 11/33 KV XLPE Cable where the cable will be laid. |
| 49 | Mounting of cable box on double pole without Pipe |
| 50 | Mounting of cable box on double pole With Pipe |
| 51 | Making of33/11 kV straight through joints for jointing the cableincluding digging of pit and making a proper chamber using bricks, cement, etc (for tracing the straight through joint location) alongwith marking using stone pads of proper size as approved by KESCo. |
| 52 | Chopping of tree branches lying in the route of existing line touching the tree branches to the phase line conductor making fault to the feeder, for 3” to 18” dia or as per requirement of site. |
| 53 | Installation of 33 KV O/D Type CT/PT on double pole (Including erection of double pole). |
| 54 | Loading, Carriage and Unloading of f 33 KV Isolators. |
| 55 | Erection and groutingIsolator Structure. |
| 56 | Erection and grouting Cable Support Structure. |
| 57 | Erection and grouting33 KV Isolator |
| 58 | Painting of Isolator Structure. |
| 59 | Painting ofCable Support Structure. |
| 60 | Painting ofBusbar Gantry |
| 61 | Loading,Carriage and unloading of ACSR Dog Conductorfrom Contractor\"s Store to Work Site or Vice-Versa. |
| 62 | Laying of ACSR Dog Conductor |
| 63 | Laying of G.I. Wire including lacing |
| 64 | Mounting of 33 kV/11 kV Pin Insulator |
| 65 | ROW permission/Road Cutting/Restoration Charges against thepermission from concerning department like Nagar Nigam,PWD, NHAI, etc or whatsoever may be |
| 66 | Normal Soil |
| 67 | Kharranja/CC |
| 68 | Metallic/ Bitumen |
| 69 | Connection of newly erected network with Transmission/KESCo mains including testing, commissioning and energization of the same completely. |