}

Biennial Contract For Insulation & Refractory Work Related To B.M.D.-I / B.M.D.Ii /T.M.D. ‘D’ Tps And B.M.D.-I / B.M.D.-Ii/T.M.D. ‘C’ Tps Of Unit # 8, 9 Of 2X250 Mw & # 7, 1X110mw, Htps, Kasimpur, Aligarh, kasimpur-Uttar Pradesh

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited-UPRVUNL has published Biennial Contract For Insulation & Refractory Work Related To B.M.D.-I / B.M.D.Ii /T.M.D. ‘D’ Tps And B.M.D.-I / B.M.D.-Ii/T.M.D. ‘C’ Tps Of Unit # 8, 9 Of 2X250 Mw & # 7, 1X110mw, Htps, Kasimpur, Aligarh. Submission Date for this Tender is 18-12-2023. Boiler Supply Tenders in kasimpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40119913
Corrigendum : Biennial Contract For Insulation & Refractory Work Related To B.M.D.-I / B.M.D.Ii /T.M.D. ‘D’ Tps And B.M.D.-I / B.M.D.-Ii/T.M.D. ‘C’ Tps Of Unit # 8, 9 Of 2X250 Mw & # 7, 1X110mw, Htps, Kasimpur, Aligarh
Open Tender
Indian
Uttar Pradesh
kasimpur
18-12-2023

Tender Details

Biennial Contract For Insulation & Refractory Work Related To B.M.D.-I / B.M.D.Ii / T.M.D. ‘D’ Tps And B.M.D.-I / B.M.D.-Ii / T.M.D. ‘C’ Tps Of Unit # 8, 9 Of 2X250 Mw & # 7, 1X110mw, Htps, Kasimpur, Aligarh- 1 Boiler Furnace Ist Pass & Iind Pass 2 Steam / Water Piping Of Dia. Above 100 Mm. 3 Flue Gas Duct. Expansion / Bellows In Duct, Aph Hoppers Esp. 4 Hot Air Duct ( Primary And Secondary ) 5 Steam / Water / Oil Piping Of Dia. Up To 100Mm 6 Insulation On Valves 25Mm To 40Mm 7 Insulation On Valves 50Mm To 100Mm 8 Insulation On Valves 150Mm To 200Mm 9 Insulation On Valves 250Mm To 300Mm 10 Removal Of Old Refractory 11 Recasting Of Refratory Including The Wel 12 Insulation Of Esp Area 13 Flue Gas Duct ( I D Fan Inlet To Chimney ) 14 Hot Air Duct ( Primary And Secondary ) 15 Supply And Fixing Of 50Mm Thick L.R.B. Insulation Pads In Double Layer I.E. 100Mm With Applying New Aluminum Sheet Of 20 / 22 Gauge. 16 Supply And Fixing Of 50 Mm Thick L.R.B. Insulation Pads In Triple Layer I.E. 150 Mm With Applying New Aluminum Sheet Of 20 / 22 Gauge. 17 Complete Spray Insulation And Repair Of Spray Insulation On Following Equipments Including Supply Of Self Setting Cement Compound, Spray Wool Alkali Silicate Binder Retainers, N. S. Plate, Aluminum Shields, S.S. And Gi Wire Nettings, Removal Of Old And Damaged Insulation, Re-Fixing Of End Shields, Plastering And Finishing As Per Bhel Norms And Specifications:-A ) H.P. Casing 315 To 380Mm Thickness.B ) Ip Casing 315 To 380 Mm Thickness.C ) Esv & Ho Control Valves 315 Mm Thickness.D ) Interceptor Valves & I.P. Control Valves 315 Mm Thickness.E ) Lp Bye-Pass, Stop And Control Valves 315 Mm Thickness.All The Above Equipments Including Their End Shield On Front And Rear Side. 18 Dismantling Of Insulation Including Removal Of Sheet Metal Cladding / Plastering 19 Laying Of Insulation By Mineral Wool Pads / Loose Glass Wool For 60Mm Thick Insulation Of Density 120Kg. / M3 20 Plastering Over The Damaged Plaster Of Insulation 21 Sheet Metal Covering

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Nov-2023 TIME EXTENSION NOTICE Date 21-11-2023
2 21-Nov-2023 Date Extension2 Date 04-12-2023
3 05-Dec-2023 Date extnsion 3 Date 18-12-2023

Key Value

Document Fees
INR 2714 /-
EMD
INR 45000.0 /-
Tender Value
INR 22.66 Lakhs /-

BOQ Items

Name of Work: Biennial Contract for Insulation & Refractory work related to B.M.D.-I / B.M.D.II /T.M.D. ‘D’ TPS and B.M.D.-I / B.M.D.-II/T.M.D. ‘C’ TPS of Unit # 8, 9 of 2X250 MW & # 7, 1X110MW, HTPS, Kasimpur, Aligarh
Sl. No. Item Description
1BOILER FURNACE IST PASS & IIND PASS
2STEAM/WATER PIPING OF DIA. ABOVE 100 MM.
3FLUE GAS DUCT. EXPANSION / BELLOWS IN DUCT, APH HOPPERS ESP.
4HOT AIR DUCT (PRIMARY AND SECONDARY)
5STEAM / WATER / OIL PIPING OF DIA. UP TO 100MM
6INSULATION ON VALVES 25MM TO 40MM
7INSULATION ON VALVES 50MM TO 100MM
8INSULATION ON VALVES 150MM TO 200MM
9INSULATION ON VALVES 250MM TO 300MM
10REMOVAL OF OLD REFRACTORY
11RECASTING OF REFRATORY INCLUDING THE WEL
12INSULATION OF ESP AREA
13FLUE GAS DUCT (I D FAN INLET TO CHIMNEY)
14HOT AIR DUCT (PRIMARY AND SECONDARY)
15SUPPLY AND FIXING OF 50MM THICK L.R.B. INSULATION PADS IN DOUBLE LAYER I.E. 100MM WITH APPLYING NEW ALUMINUM SHEET OF 20/22 GAUGE.
16SUPPLY AND FIXING OF 50 MM THICK L.R.B. INSULATION PADS IN TRIPLE LAYER I.E. 150 MM WITH APPLYING NEW ALUMINUM SHEET OF 20/22 GAUGE.
17COMPLETE SPRAY INSULATION AND REPAIR OF SPRAY INSULATION ON FOLLOWING EQUIPMENTS INCLUDING SUPPLY OF SELF SETTING CEMENT COMPOUND, SPRAY WOOL ALKALI SILICATE BINDER RETAINERS, N. S. PLATE, ALUMINUM SHIELDS, S.S. AND GI WIRE NETTINGS, REMOVAL OF OLD AND DAMAGED INSULATION, RE-FIXING OF END SHIELDS, PLASTERING AND FINISHING AS PER BHEL NORMS AND SPECIFICATIONS:- A)      H.P. CASING 315 TO 380MM THICKNESS. B)      IP CASING 315 TO 380 MM THICKNESS. C)      ESV & HO CONTROL VALVES 315 MM THICKNESS. D)     INTERCEPTOR VALVES & I.P. CONTROL VALVES 315 MM THICKNESS. E)      LP BYE-PASS, STOP AND CONTROL VALVES 315 MM THICKNESS. ALL THE ABOVE EQUIPMENTS INCLUDING THEIR END SHIELD ON FRONT AND REAR SIDE.
18DISMANTLING OF INSULATION INCLUDING REMOVAL OF SHEET METAL CLADDING/PLASTERING
19LAYING OF INSULATION BY MINERAL WOOL PADS/LOOSE GLASS WOOL FOR 60MM THICK INSULATION OF DENSITY 120KG./M3
20PLASTERING OVER THE DAMAGED PLASTER OF INSULATION
21SHEET METAL COVERING
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail