Tender For Provision Of Store For Minor Fire Fighting Equipments Provision Of Drainage And Foldable Gate At The Entrance And Exit Of Bldg No. P-7, Coimbatore-Tamil Nadu

Military Engineer Services-MES has published Tender For Provision Of Store For Minor Fire Fighting Equipments Provision Of Drainage And Foldable Gate At The Entrance And Exit Of Bldg No. P-7. Submission Date for this Tender is 08-11-2023. Drainage Tenders in Coimbatore Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

40113125
Corrigendum : Tender For Provision Of Store For Minor Fire Fighting Equipments Provision Of Drainage And Foldable Gate At The Entrance And Exit Of Bldg No. P-7
Open Tender
Indian
Tamil Nadu
Coimbatore
08-11-2023

Tender Details

Tender For Provision Of Store For Minor Fire Fighting Equipments Provision Of Drainage And Foldable Gate At The Entrance And Exit Of Bldg No. P-7

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-11-2023
2 03-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 19900.0 /-
Tender Value
INR 9.95 Lakhs /-

BOQ Items

Name of Work: PROVN OF STORE FOR MINOR FIRE FIGHTING EQUIPMENTS , PROVN OF DRAINAGE AND FOLDABLE GATE AT THE ENTRANCE AND EXIT OF BLDG NO. P-7 UNDER AGE (I) (AF) COIMBATORE.
Sl. No. Item Description
1Excavating intrenches not exceeding 1.5mwide and not exceeding 1.5 m in depth and getting out in hard/dense soil .
2Returning ,filling in ,including spreading ,levelling,watering and well ramming in layers not exceeding 25cm in hard dense soil.
3Removing surplus excavated soil to a distance exceeding 5 km but not exceeding15 kmand depositing where directed
4Plain cement concrete 1:4:8 type D2 using40 mm graded stone aggregate as in foundations ,fillling and mass concrete.
5M&L for RCC design mix M-25 (20mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
6M&L for RCC design mix M-25 (20mm graded aggregate) in Columns, pillars, piers, posts and struts
7M&L for RCC design mix M-25 (20mm graded aggregate) in Beams,cantilevers, bressummers, lintels over 1.5m span
8M&L for RCC design mix M-25 (20mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
9M&L for RCC design mix M-25 (20mm graded aggregate) inchajjas etc.
10M&L for flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete.
11M&L for flat formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete.
12M&L for flat formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.for rough finished surfaces of concrete.
13M&L for flat formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)for rough finished surfaces of concrete.
14M&L for flat formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofsn.exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide .
15M&L for flat formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete.
16M&L for TMT bars 10 mm dia over cut to length,bent to shape required, including cranking ,bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia.
17All as above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
18Precast cement concrete block masonrywith solid blocksexc 10 cm in width in PCC 1:2:4 type B-1 and setting in cement mortar 1:4 all as specified
19M & LRendering in CM 1:3, 5mm thick on fair faces of brick work or concrete surfaces on ceiling complete all as specified.
20M & L for preparation of newlyplastered surfaces and applying threecoats of white washon ceiling.surface all as specified.
21M&L for Rendering with WPC in CM 1:4, 15mm thick on othe thanfair faces of brick work or concrete surfaces all as specified and directed. Note : WPC shall be measured and paid separately
22Supply only Intergral waterproofing compound
23M&L for Rendering in CM 1:6, 10mm thick on fair faces of brick work or concrete surfaces all as specified and directed.
24M & L prepaeation newly plasteredof wall surfaces and applyingtwo coats of acrylic smooth exterior paint of required shade (applied @ 1.67ltr/10 Sqm) over and including priming coat of exterior primer @2.20 Kg/10 Sqm) all as specified .
25M & L prepation of newly plastered wall surfaces and applyingtwo coats of distemper oil emulsion over over a coat of primer over 3mm thick wall care putty on wall all as specified and as directed .
26M & L for Non-skid coloured ceramic tiles 7 to 8mm thick(square / rectangular) area of each tile exceeding 0.11 Sqm but exceeding 0.18 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface all as specified and as directed by Engr-in-charge..
27All as per item Noabove but as in skirting/Dado
28M&Lfor Screed bed or bedding layer of mortor 15 mmthick in CM 1:6 for laying floor finishes all as specified and directed.
29M&L for Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) in sub base of floor
30M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4as in backing coat of skirting /dado all as specified and directed.
31M&L for IInd class hard wood , Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed.
32S&F 40mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and both faces are covered with decorative face veneer with lipping/frame to match
33M&L for applying one coat of synthetic enamel paint preparation of old wooden surfaces all as specified and directed.
34S&F100mm long butt hinges, medium weight, cold rolled mild steel with brass/bronze hinge pin.
35S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
36S&F 200mm longAluminium anodised, barrel tower bolts of extruded section and fixed
37S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring
38S&F 25 mm dia SS drapery rod , including brackets, decorative knobs at both ends & curtain rings 8 Nos (minimum) completeall as speccified and directed.
39Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
40Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
41Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer- in-charge.
42S&F 4mm sheet glass, ordinary quality ,n exc 0.5 sqm in each glass all as specified and directed.
43S&F stainless steel wire cloth 00.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless stell wire staples.
44M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)
45M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface.
46M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
47Supply and application of single component, seamless, spray applied, hybrid elastomeric PU based material i.e Nitoproof 725 of Fosroc chemicals (or) sikalastic 590 of Sika India Pvt Ltd (or) equivalent in any approved make as approved by GE over a coat of primer i.e Nitoproof WB primer of Fosroc chemicals (or) diluted sikalastic 590 of Sika India Pvt Ltd (or) equivalent in any approved make as approved by GE, all as recommended by manufacturer ans as specified. Note:-(i) Average minimum DFTof PU based material shall be 1mm and shall be applied by using a Graco pump. (ii) PU based material shall process the following properties solids by volume -65%, tensile strength ASTM D412-1.75Mpa, density 1.3 g/ml, elongation ASTM D-412-350%, Adhesion to substrate concrete-1.9Mpa, resistance to water-10m pressure. (iii) Rate are deemed to be include for cleaning and preparation of surface to receive PU water proofing system including filling of cracks with cementitious repair mortars i.e renderoc CS of Fosrock chemicals (or) equivalent of approved make. (iii) Work shall be got carried out by authorised applicator of the manufacturer and it shall be got approved by the GE before progressing the work. (iv) 10 years of guarantee shall be provided and security amount shall be deposited as speicified in tender documents.
48Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft loose soil.
49Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete
50Supply, installation & testing of maintenance free chemcal earthing of copper coated electrode pipe of length 3 mtr long and 76 mm dia, having terminal size 50x6 mm, the earth electrode pipe is tightly filled with Crystalline Conductive Mixture (CCM) and then sealed. The electrode shall be installed by making bore of 200 mm dia & 3 Mtr deep below normal ground level, after using & including 10 KG ground enhencing material, the electrode shall be surrounded by and including 60 KG Back Fill Compund (Chemical compound provided by manufaturer) complete including making earth pit chamber of size 30CM x 30 CM x 15 CM complete.Note: The extra chemical compound if required to bring earth resistance value less than 1 ohm, shall be provided without any extra cost. Make: Innove Infra Solutions, Cat No. ELE-380-CU, SABO System Pvt Ltd Cat No. SCE80XYZ or equivelent in JMV LPS Ltd.
51M&L for test point terminal block made of gun metal or phosphorous bronze size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw.
52M&L for earth coninuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit / pipe or fixed to pole or any other indicated situation or for loop earthing complete of copper strip size 32x6 mm fixed by using and including suitable size of porcelain insulators in such a manner that strip can be separeted from the wall.
53M&L for concealed Point wiring one light point controlled by one, one way switch complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistrandedcopper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note: Cutting chases and making good in wall / floor will be Measured and paid seperately.
54All as per item No 53 here-in-before but one fan / exhaust fan point controlled by one, one way switch.
55All as per item No 53 here-in-before one05 Amps socket outlet pointon same board.
56All as per item No 53 here-in-before one 05 Amps socket outlet point on independent board.
57All as per item No. 53 here-in-before but with copper conductor cable FRLS, 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
58Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals.
59S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed.
60S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed.
61S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed.
62S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed.
63S&F modular Fan step regulator, 120W - 2 module complete all as specified and as directed.
64Supply and fixing LED lights fitting 1x 20W (Warm/Day Cool as required on site), 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
65S & F LED light fitting 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copperconductor cable of suitable size.
66S &F modular white cover plate with frame 2 module
67S &F modular white cover plate with frame 3 module
68S &F modular white cover plate with frame 8 module
69S &F modular metal flush box 1/2 module
70S &F modular metal flush box 1/3 module
71S &F modular metal flush box 6/8 module
72Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame andlouvers
73Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) incl fan hook, nut, bolt etc complete.
74Supply and fix MCB DB, SPN, 8 ways, Isolated neutral bar with single doorIP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete. Make: L&T/Legrand/ Havells
75Supply and fixing 240V, 10 KA "B" curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning.
76Supply and fixing 240V, 10 KA "B" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
77Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth
78Material and Labour for laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, multi stranded, 1100 volts grade, cross-sectional area 25 Sqmm, 2 core with and including making connection by using necessary thimbles complete all as specified and directed.
79M&L for riddled earth filling in trenches above and below the cable as in cable protection.
80Supply and laid well burnt bricks sub-class "B" designation 75 for cable protection, brick shall be laid dry flat as width of brick eqals to the length of cable and the gap between two adjacent brick shall not exceeded 10 mm, complete all as specified and as directed.
81M&L for GI pipe 32 mm dia light grade with all fittings for cable protection laid under road/path/hard standing or fixed with wall/pole etc complete.
82M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead GI wire 4mm dia ( 8 SWG) connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts, washers of galvanised iron, thimbles and other end of earth wire connected to main switch board and protected by galvanised iron pipe medium grade 15mm bore and20mm bore medium grade GI pipewith funnel and wire mesh for watering including necessaryexcavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR( Part-I) of 2009.(i)The unit rate includes earthing wire, and protection pipe upto 7.5 metre.
83M&L for 4 mm dia galvanised iron or steel wire as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete.
84M&L for cutting of existing bituminous road/path/hard standing suitable for laying cable protection pipe 32 mm dia under the road/path/hard satnding at a depth not less than 60 CM below the normal ground level, Returning filling soil and making good the disturbed surface of road/path/hardstanding by using cement concrete mortar 1:2:4 type B1, using 20 mm graded stone aggregate 0.30 mtr wide and 0.30 mtr thick complete all as specified and directed.
85M&L for extra form farming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds ,mitred stopped ends etc.
86M&L for PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) for coping and benchinginside the manholes including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed.
87M&L for Precast cement concrete 1:2:4, type B1(using 20 mm graded stone aggregate) as in cover slab for manholes set in cement mortar 1:6 complete all as specified and directed. Note: Reinforcement will be measured and paid separately (use and waste of form work is deemed to be included).
88S&F MS Steel pipe medium grade150mm bore single socketed in any length with socket jounts laid in trenches or in floor.
89M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4as in backing coat of skirting /dado all as specified and directed.
90M & L Glazed coloured ceramic/ext walltilesin vertical surface450x350x7mm thickset and jointed in neat cement slurry and pointed in white or coloured cement to match the surface all as specified and as directed by Engr-in-charge..
91M&L for Granite of any type16 to 18 mm thick machine cut, in skirting /dado laid over 10mm thick rendering in CM 1:4 cement screed andjointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing completeall as specified and as directed.
92S&F Cast Iron for ornamental and intricate design and similar articles all as specified and directed.
93S&F of Framed work such as grills, gratings, framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etcetc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework ofconforming to Fe.290.Gde-E-165
94S&F Mild steel, 0.80mm thick plain, black sheet sheeting is welded to frame ,covering to door of steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bendingor turning up, mitred angles, etc. as required
95S & F of MS flat iron for securing ms sheet including all necessay welding or bolting or riveting etc and similar work conforming to Fe-290 gde E-165
96Supply only broken bricks for loose filling of gauge 40mm to 80mm graded
97Removing off demolished/excavedbuildingmaterialout side the campus including loading and unloading etc., to a distance exc 5.0 Km but not exc 10.0Km out side the MD land. Note: Responsibility of getting permission from concerned authority for disposal off and place of depositing the debris outside MD land and rests with contractor under his own arrangements.