Tender For Repair Replacement Of Lt Ug Cables, Earthing , Mccb And Other Connecting Works In Drde Gwalior And Repair Replacement Of Street Light Fittings, Flood Light, High Mast Light, Junction Box And Other Connecting Works At Adrde Agra Under Ge I, agra-Madhya Pradesh

Military Engineer Services-MES has published Tender For Repair Replacement Of Lt Ug Cables, Earthing , Mccb And Other Connecting Works In Drde Gwalior And Repair Replacement Of Street Light Fittings, Flood Light, High Mast Light, Junction Box And Other Connecting Works At Adrde Agra Under Ge I. Submission Date for this Tender is 04-11-2023. Electrification Work Tenders in agra Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40111650
Corrigendum : Tender For Repair Replacement Of Lt Ug Cables, Earthing , Mccb And Other Connecting Works In Drde Gwalior And Repair Replacement Of Street Light Fittings, Flood Light, High Mast Light, Junction Box And Other Connecting Works At Adrde Agra Under Ge I
Open Tender
Indian
Madhya Pradesh
agra
04-11-2023

Tender Details

Repair Replacement Of Lt Ug Cables, Earthing , Mccb And Other Connecting Works In Drde Gwalior And Repair Replacement Of Street Light Fittings, Flood Light, High Mast Light, Junction Box And Other Connecting Works At Adrde Agra Under Ge I Rnd Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 77600.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : REPAIR/REPLACEMENT OF LT UG CABLES,EARTHING , MCCB AND OTHER CONNECTING WORKS IN DRDE GWALIOR AND REPAIR REPLACEMENT OF STREET LIGHT FITTINGS, FLOOD LIGHT, HIGH MAST LIGHT,JUNCTION BOX AND OTHER CONNECTING WORKS AT ADRDE AGRA UNDER GE I RnD DELHI.
Sl. No. Item Description
1Disconnecting, taking out and removing old existing underground, LT cable of any description and in any position complete including taking downprotection pipe, PCC Cover/Bricks etc complete all as specified and directed for the following sizes:-
235 Sqmm to 70 Sqmm any core
395 Sqmm to 150 Sqmm any core
4185 Sqmm to 400 Sqmm any core
5Relaying old serviceable cable , jointing and testingany description and any size laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed for the following :- Note:- Old unserviceable cable retreived from item Srl No. 1 shall be reused.
635 Sqmm to 70 Sqmm any core
795 Sqmm to 150 Sqmm any core
8Supply, laying, jointing and testing XLPE/ PVC insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description laid in trenches/ducts, floors, fixed to walls etc the following sizes. complete all as specified and directed.
935 Sqmm 3.5core
1070 Sqmm 3.5core
1195 Sqmm 3.5core
12150 Sqmm 3.5 core
13300 Sqmm 3.5 core
14400 Sqmm 3.5 core
15Excavation in trenches in soft/loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes etc. Including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m complete all as specified and directed. Note :- Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.
16Returning, filling in including spreading, levelling, watering and well ramming in layers of 25 cm thickafter the cables etc are laid, jointed & tested complete all as specified and directed
17Removal of surplus excavated soilexc. 50 mtr butn. exc. 250 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 M above the starting point etc complete all as specified and directed.
18M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection etc complete all as specified and directed. Note :- Punned thickness shall be measured & paid.
19Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
20Laying only old serviceable Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
21M&L for boring holes under road, pavement, hard standing by trenchless techonology using ultra sound technique and necessary machine including supply and laying of GI pipe of 100 mm dia light grade complete all as specified and directed.
22Supply and laying in replacement of GI pipe light grade of 100mm dia laid in trenches for protection of UG cable complete all as specified and directed.
23All as per item Ser No 11.00 above but GI pipe 80 mm dia.
24All as per item Ser No 11.00 above but GI pipe 50 mm dia
25Disconnecting LT cable of size from 16 Sqmm 4 core to 35 Sqmm 3.5 core from existing panel taking out loop of cable not more than 2.5 M length, cut the worn out portion of cable including replacement the lugs,nut-bolt and washers of suitable size and reconnect with the existing system complete all as specified and directed.
26Disconnecting LT cable of size from 50 Sqmm 3.5 core to 95 Sqmm 3.5 core from existing panel taking out loop of cable not more than 2.5 M length, cut the worn out portion of cable including replacement the lugs,nut-bolt and washers of suitable size and reconnect with the existing system complete all as specified and directed
27Disconnecting LT cable of size from 120 Sqmm 3.5 core to 240 Sqmm 3.5 core from existing panel taking out loop of cable not more than 2.5 M length, cut the worn out portion of cable including replacement the lugs,nut-bolt and waser of suitable size and reconnect the existing system complete all as specified and directed.
28Disconnecting LT cable of size from 300 sqmm 3.5 core to400 Sqmm 3.5 core from existing panel/ transformer/LT Poles andtaking out loop of cable not more than 5 M length, cut the worn out portion of cable including replacement the lugs,nut-bolt and washer of suitable size and reconnect the existing system complete all as specified and directed
29Dismantling and taking down existing serviceable/unserviceable/ de-shaped/worn out LT/HT steel tubular / PCC pole of any shape, size & height including demolition of existing PCC foundation complete all as specified and directed.
30Supply and erection of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-3109 Mtr long. Poles shall be coated with two coats of black bituminous paint throughout internally, and externally up to the planting depth.The remaining portion of the exterior shall be painted with two coats of synthetic enamel paint in tint and pattern as approved over one coat of red oxide primer complete all as specified and directed.
31Supply and errection of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-5511 Mtr long. Poles shall be coated with two coats of black bituminous paint throughout internally, and externally up to the planting depth.The remaining portion of the exterior shall be painted with two coats of synthetic enamel paint in tint and pattern as approved over one coat of red oxide primer complete all as specified and directed.
32M&L for PCC 1:3:6type C-2 (Using 40 mm graded stone aggregate as in sub base/ foundation etc complete all as specified and directed.
33M&L for PCC 1:2:4 type B-1 (Using 20 mm graded stone aggregate) for coping of poles including necessary form work complete all as specified and directed.
34M&L for PCC 1:4:8 type D-2 (Using with40 mm graded stone aggregate) for foundation of polecomplete allas specified and directed.
35Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick buried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron strip of 25x4 mmby means of Copper nuts, bolts and washers.Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a)GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothlyfinished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover.
36S&F Earth continuity conductor passing through PVC Conduit of size 40 mmmain earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip complete all as specified and directed.
37S&F in replacement aluminium bus bar PVC insulated in RED, Yellow, Blue & Black colours of rating 400 Amps complete all as specified and directed.
38S&F in replacement aluminium bus bar PVC insulated in RED,Yellow, Blue & Black colours of rating 800 Amps complete all as specified and directed.
39S&F in replacement aluminium bus bar PVC insulated in RED,Yellow,Blue & Black colours of rating 1600 Amps complete all as specified and directed.
40S&F in replacement busbar insulator of appropriate size with existing one complete all as specified and directed.
41S&F in replacement 3 Pole MCCB,100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
42All as per item Ser No 30.00 above but MCCB 3 Pole 160 Amp, 25 KA.
43All as per item Ser No 30.00 above but MCCB 3 Pole 400 Amp, 36 KA.
44All as per item Ser No 30.00 above but MCCB 3 Pole 630 Amp, 50 KA
45S&F in replacement 4 Pole MCCB, 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed.
46All as per item No 34.00 above but MCCB 4 Pole 400 Amp, 36 KA
47All as per item No 34.00 above but MCCB 4 Pole 630 Amp, 50 KA
48S&F in replacementACB 800 Amps 4 pole with thermal magnetic release (manual fixed type) complete all as specified and directed.
49S&F in replacement ON load changeover with front operated OPEN Execution fixing in (LT Panel) 400 Amps, 4 Pole, 415 V, AC, 50 Hzcomplete all as specified and directed. Make :- Havells Cat No- IHCNF00400 or eqvl make /L&T / Schnieder /Siemens
50S&F in replacement Aluminium thimble of size 35 sqmm for terminal end of cable complete all as specified and directed.
51S&F in replacement Aluminium thimble of size 50 sqmm for terminal end of cable complete all as specified and directed.
52S&F in replacement Aluminium thimble of size 70 sqmm for terminal end of cable complete all as specified and directed.
53S&F in replacement Aluminium thimble of size 95 sqmm for terminal end of cable complete all as specified and directed.
54S&Fin replacement Aluminium thimble of size 120 sqmm for terminal end of cable complete all as specified and directed.
55S&F in replacementAluminium thimble of size 150 sqmm for terminal end of cable complete all as specified and directed.
56S&F in replacement Aluminium thimble of size 185 sqmm for terminal end of cable complete all as specified and directed.
57S&F in replacementAluminium thimble of size 240 sqmm for terminal end of cable complete all as specified and directed.
58S&F in replacementAluminium thimble of size 300 sqmm for terminal end of cable complete all as specified and directed.
59S&F in replacementAluminium thimble of size 400 sqmm for terminal end of cable complete all as specified and directed.
60S&F earth pit chamber alongwith cover of Polymer, FRP Pit Cover of heavy high grade polypropelene for high stress and strain level of size 225x300x195 mm complete all as specified and directed.
61Restringing of existing ACSR’s conductors and earth wires including cradles, of any description, size & shape and in any position, as in LT/HT overhead lines, on existing poles, including opening of connections and binding wires, restringing and tightening of conductors/earth wire in position, removing sag, binding to insulators with new aluminum wire, making and connecting jumper connections etc. including testing complete all as specified and directed. Note :-The quoted rates shall be deemed to include the following provisions also :- (i)Setting/adjusting etc in position of cradles. (ii) Old serviceable spacers of ACSR conductor shall be reused and fixed complete all as specified and directed.
62Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any description /size & in any position from existing LT/HT Poles/Lines complete all as specified and directed.
63S&Faluminium conductor, steel reinforced (ACSR) of any size/description on LT poles/linesincluding stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing complete all as specified and directed. Note:-Old serviceable spacers obtained from taking down of ACSR conductor under item No. 50.00 shall be reused and fixed complete all as specified and directed.
64Re-Fixing and stringing of old ACSR’s conductors and earth wires including cradles, of any description, size & shape and in any position, as in LT/HT overhead lines, on existing poles, including opening of connections and binding wires, restringing and tightening of conductors/earth wire in position, removing sag, binding to insulators with new aluminum wire, making and connecting jumper connections etc. including testing complete all as specified and directed. Note :-The quoted rates shall be deemed to include the following provisions also :- (i)Setting/adjusting etc in position of cradles. (ii) Old serviceable spacers of ACSR conductor shall be reused and fixed as directed by Engineer-in-Charge
65Dismantling & taking down of existing worn out / unserviceable GI wire of any description/size & in any position from existing LT/HT Lines including cradle guard wires complete all as specified and directed.
66S&F GI continuous earth wire of size 4mm/3.15mm dia on LT/HT poles as in cradle guards / earth wires etc including binding complete all as specified and directed.
67Dismantling & taking out of old existing unserviceable steel & iron items from poles such as cross arms, bracing, supports, clamps andback plate fabricatedfrom structural steel sections including nuts & bolts, washersof any description and in any position from LT over head line poles/ street light poles complete all as specified and directed.
68Fixing Only old serviceable steel & iron ,mild steel such as cross arms, bracing, supports, clamps andback plate fabricated from structural steel sections including nuts & bolts, washers and encluding painting with one coat of synthetic enamel paintcomplete all as specified and directed.
69Supply, fabrication and fixing for mild steel such as cross arms, bracing, supports, clamps andback plate fabricated from structural steel sections including nuts & bolts, washersof any description ofLT over head line poles/ street light poles complete all as specified and directed.
70Dismantling & taking out of old existing unserviceable insulators of any description and in any position from LT/HT poles complete all as specified and directed.
71S&F single disc assembly for disc type insulator porcelain vitreous 145mm high and 255mm dia ball and socket type, white , brown or green HT 11 KV grade for HT overhead lines complete all as specified and directed. Make Jayshree/Modern /Jaipuria brothers/Mysore porcelain /WS insulator.
72S&F pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 150mm height and 150mm dia suitable for working pressure upto and including 11000 volts grade for HT lines fixed on poles complete all as specified and directed. Make Jayshree/Modern /Jaipuria brothers/Mysore porcelain /WS insulator
73All as per item Ser No 61.00 above but of size 100mm height and 65mm dia suitable for 1100 volts grade for LT lines fixed on poles complete all as specified and directed. Make Jayshree/Modern /Jaipuria brothers/Mysore porcelain /WS insulator
74S&F Shackle type 75mm height and 90mm dia insulator, porcelain,vitreous, white, brown or green including galvanised mild steel strap 31mm X 3mm, insulator bolts 12mm dia with suitable washers and nut, suitable for working pressure upto & including 1100 volts, fixed on LT poles complete all as specified and directed. Make :- Jayshree/Modern /Jaipuria brothers/Mysore porcelain /WS insulator.
75Disconnecting, dismantling and taking down existing unserviceable spacers of any description and in any position from the LT electric overhead lines of any height and supplying and fixing new PVC insulated spacers, 12mm dia flexible type suitable for making / turning to any shape and size and suitable for 2 or 3 conductor runs complete all as specified and directed.
76All as per item Ser No 64.00 above but spacers suitable for five conductors run.
77All as per item Ser No 64.00 above but PVC insulated straight strip type spacers suitable for five conductor run overhead lines. Note for item No 64 to 66: The spacer shall be of best quality and as per the sample kept in GE office.
78Disconnecting, dismantling & taking out existing unserviceable gang operated switch of any description and in any position complete all as specified and directed.
79Supply, fixing, commissioning and testing of outdoor, gang operated switch, tilting type, 11KV of current rating upto 200 Amps, triple pole, each pole consisting of galvanizedsteel base, HT insulators as per IS, non ferrous knife and spray, loaded contacts, arcing horns of adequate section to break magnetizing current of the transformers, horizontal GI pipe of adequate length for phase separation, adequate length of GI pipes for operation from ground level and operating handle with locking arrangement complete in both OFF & ON positions.All ferrous parts hot dripped galvanized and non ferrous heavily tinned to with stand weather and suitable for vertical mounting complete all as specified and directed. Make: - Pactil/Jaipuria Brothers/Atlas.
80Dismantling 11 KV air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for insulators and operating mechanism or repair/replacement o broken/worn out components and insulators etc complete all as specified and directed. Note :- New spare parts replaced for GOD shall be measured and paid for separately under respective items of BOQ as “supply only” but fixing element of same shall be deemed to be included under this item.
81Supply only the following new parts suitable for GOD of 11KV repaired under BOQ item No 69.00 above. Note :- (i)The new parts shall be suitable to match with the existing GOD. (ii) Fixing element of these items is deemed to be included under the rates quoted by the contractor for respective Schedule `A" item No 20 above.
8211KV post type insulator
83Male contact/moving contact blade.
84Female contact/fix contact Jaw
85MS Jumper carrier
86Tinned copper flexible jumper
87Back connector plate
88Dismantling and taking down existing unserviceable lightening arrestor of any capacity and any description complete all as specified and directed.
89S&F commissioning & testing of Lightning arresters HIGH TENSION 11000 VOLT expulsion type complete with all fittings,transmission class discharge capacity 65 kilo amp confirming to EC-99 -41/1990 including brackets, clamps, bolts, nuts and washers complete all as specified and directed. Make:- Oblum/ Jaipuria Brothers/Elpro.
90Dismantling and Taking down existing unserviceable stay assembly and supply and fixingfor stay assembly comprising of 16mm dia, 1.80 metre long galvanized stay rod, having 7/3.15mm GI stay wire stranded and 230mm x 230mm x 6mm thick stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/ accessories like loop type insulator, stay clamps, necessary excavation and earth work in any type of soil and PCC works in (1:3:6) type C-2 (using 40mm graded stone aggregate) including taking down and dismantling old unserviceable stay assembly etc complete all as specified and directed.
91All as per item Ser No 79.00 above but stay assembly having stay rod of 20mm diaand 2.15 metre long with 300mm x 500mm x 6mm thick MS plate.
92Trimming/cutting of all trees branches and cleaning of buses upto 2 metre distance both side from nearest conductor/Earth wire at LT/HT overhead line including cleaning of site and depositing of material upto 250 metre distance complete all as specified and directed.
93Surface excavation,grass cutting over the areas around the poles/feeder piller boxes/ sub stations not exceeding 15cm depth includingcleaning the bushes and vegetation/root of small trees and leveling incl removal of surplus soil in soft/hard dense soil.and deposited where 15 cm complete all as specified and directed. Note:- Two time over contact
94Dismantling and taking down existing unserviceable/worn out danger notice plateof any description& any position and supply & fixing for danger notice plate 20x15 cm size and 1.6 mm thick mild steel vitreous enameled white, with letters, figures and conventional skull andbones in signal red colour and fixed with including connected accessories complete all as specified and directed.
95Dismantling and taking out unserviceable 11 KV HT sleeves by opening PG clamps of any description of any position supplying & fixing HT 11 KV heat shrinkable epoxy sleeves in prescribedcolour complete all as specified and directed.
96S&F (PG Clamp) by Compression/crimping type sleeve joints for jointing conductors/jumper connections including treatment with conducting jelly complete all as specified and directed.
97Dismantling & Taking down OldAnti climbing devices and Supply and FixingFor Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered clamps measured separately complete all as specified and directed.
98Demolition for cement concrete/in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified and directed.
99M&L for 100 mm thick PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) complete all as specified and directed.
100M&L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded aggregate) as in floor finishing even and smooth with using extra cement and making impression of expanded metal, while concretemaking good as per existing surface etc complete all as specified and directed.
101M&L for preparationof old painted surfaces of steel tubularpole of 9 mtr strut pole (LT/HT) includingprotectionpipe, cross arms, clamps, GI pipebracket ofstreet/ security light , anti climbing devices etc. including scraping out old rusted paint and applying one coat of red oxide primer and two coat of aluminiumpainton all the metallic surfaces complete all as specified and directed. Note:- Numbering of the poles andrepainting blue bands shall be done with syntheticenameled paint, letter/ band"s shape & size shall be as per existing complete all as specified and directed.
102M&L for preparationof old painted surfaces of steel tubularpole of 11 mtr strut pole (LT/HT) includingprotectionpipe, cross arms, clamps, GI pipebracket ofstreet/ security light , anti climbing devices etc. including scraping out old rusted paint and applying one coat of red oxide primer and two coat of aluminiumpaint on all the metallic surfaces complete all as specified and directed. Note :- Numbering of the poles and repainting red bands shall be done with synthetic enameled paint, letter/ band"s shape & size shall be complete all as specified and directed.
103M&L for preparationof old painted surfaces of twopole structure of steel tubularpole of 9/11 mtr strut pole (LT/HT) includingprotectionpipe, cross arms, clamps, GI pipebracket for street/ security light , anti climbig devices etc. including scraping out old rusted paint and applying one coat of red oxide primer and two coat of aluminium painton all the metallic surfaces complete all as specified and directed. Note :- Numbering of the poles and repainting red bands shall be done with syntheticenameled paint. letter/ band"s shape & size shall be complete all as specified and directed.
104Supplying, laying, jointing & testing, in replacementof 1100 volts grade, heavy duty, LT XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed,3.5 Core, 25 Sqmm nominal cross section in service connections laid in loops /ducts, along wall /pole orunder floor /roador laid in trenches including taking out old unserviceable cable complete all as specified and directed.
105All as per item Ser No. 93.00 above but16 Sqmm 4 Core.
106All as per item Ser No. 93.00 above but10 Sqmm 2 Core.
107Dismantling and taking down unserviceable street light / security light fitting/hanger light(highbay type) of 30/45/48/60/70/90/120 watt from existing Bldgor Street light pole after disconnecting all electrical connections for repair or replacement of unserviceable parts and re-fixingthe same after making it serviceable and including all electrical connections complete all as specified and directed.
108Dismantling and taking down unserviceable High mast lantern complete set ( 9 Nos x 180 watt / 8 Nos x 180 watt ) from high mast pole after disconnection all electrical connections and refixing the same after making it serviceable including all electrical connections complete all as specified and directed.
109Dismantling and taking down unserviceable street light driver of 30/45/48/60 watt from existing LED street light after disconnecting all electrical connections for repair or replacement of unserviceable parts and re-fixingthe same after making it serviceable and including all electrical connections complete all as specified and directed.
110S&F New generation energy saving and environmental friendly long life LED street light fitting 45 Watt,made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete all as specified and directed.
111S&F LED Energy saving, environment friendly, long life, exclusive innovative die-cast aluminium flood light 180 Watt, with highly efficient LEDs as light source, suitable for highlighting architectural features or retail spaces complete all as specified and directed.
112M&L for wiring for circuit/submain wiring with 2 run of 1.5 sqmm, FRLS PVC insulated single core, copper conductor for phase and neutral and 1 run of same size of copper conductor for earth wire,in PVC Conduit of size 20 mm dia including fixing clamp, nuts, bolts, screw etc and connectiin up with street light/ security light/ junction box, including dismantling/ taking down of old unserviciable wiring circuit from existing Pole complete all as specified and directed.
113Disconnecting the all electrical connections from street light junction box/timer panel and taking out the loop ofXLPE UG cable of any size and connecting to the street light junction box/ timer panel after cutting the faulty/burnend out end and opening of UG cable loop complete all as specifed and directed. Note:- 1.Taking out the old brick and relaying the same after opening of loop shall be included in quoted rate. 2.Exavation work as required for LT cable ( Depth upto than .5 Mfrom GL and width not less than .4 M) shall be included in the quoted rate. 3.Sand as requiredwill be measured and paid seperately. 4.Material required for electrical connections such as lugs,cable gland ,PVC tape etc shall be included in the quoted rate.
114S& F IntegralLED aviation light luminiariescomprising of aluminiumhousing withpolycornonate enclosureincluding connectingup with twincore twisted flexible copper conductorcable including taking out the old one complete all as specified and directed. Make:- Bajaj, Cat Part No-110731 and Luminaure type BGAV 302 LEDor equvilant as approved by GE. Note:- Cutting,drilling,welding,GI nuts,bolts and washers as required for fitting of LED aviation light at the place of conventional aviation light shall be included in quoted rate.
115M & L forold painted surfaces of LT/HT Steel tubular polesof any size shape and height complete andapplying synthetic enamel paint of 200 mm widthwith alternate block ofwhite /black upto 5 feet height from ground level including writing the pole No with black enameled paint of size 70 mmwideand 100 mm height, and applying two coatsof alluminiumpaint on the balance portion of pole after necessary preparation of surfaces and cleaning the vegetation approximately 4 square meter around the pole including following works complete all as specified and directed :- (a)Cross arms (each pole 2 Nos). (b)45/50 mm dia bracket (each pole 1 Nos) including clamps (c)Junction Box with two coats of synthetic enamle paint over a coat of red oxide primerafter necessary preparation of surfaces including clamps,nuts ,bolts,wahers etc. Note :- Two coats of aluminimum paint will be used and deemed to be included into quoted rate .
116Supply and erecting in true vertical position steel tubular swaged poles type 410 SP-22 (8.5 meter long) complete with CI base plate pole cap,finial taper plug,bolts, nuts, washersetc including painting with two coats of synthetic enamel paint over a coat of red oxide primer including taking down old unserviceable pole complete all as specified and directed. Note:- (i)The portion above coping shall be painted in alternative bands of black & white colours starting with black colour (each band of 30 Cm wide) by two coats of Synthetic enamel paint upto 1.5 meter height and the cost of same shall be deemed to be included in the rate quoted. (ii) The pole numbers etc shall be enumerated on the poles and the cost of writing letters with synthetic enamel paint shall be deemed to be included in the rate quoted. (iii) PCC and and exavation shall be measured and paid seperately. (iv)The rates alsoincludedrilling of holesinsteel tubular poles for continuous G.I. earth wire etc. to the required size and number.
117M&L in replacement for GI pipe (light grade) with all fittings laid in trenches/wall complete for protection UG cable when crossing the road of size 40 mm bore complete all as specified and directed.
118M&L for boring of holes by manually / machine under road, pavement, hard standing by trenches for laying of 40 mm GI pipe for cable laying, complete all as specified and directed.
119S&F street light bracket made out GI Tubing, 40 mm dia medium grade of length 1.5 Mtr rendering bend of 120 degree including 2 pairs of clamps 30mm X 5 mm including nuts,bolts,washers including painting with two coat of synthetic enamel paint over a coat of red oxide primer on externalsurface of brackets complete all as specified and directed.
120Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron wire 4mm dia by means of Copper nuts, bolts and washers. GI wire laid in 20mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a)GI wire 4 mm dia (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
121M& L for fixingjunction boxmade of plastic material of size 239X328X129 mm withopaque cover ,conical cable gland aluminium lugs, Protection Class IP 65,04 nos aluminium bus bar of size 25x3 mm for three phase and neutral including 01 nos 06 Amps MCB SP for controlling street light and2 Nos MS clamp of size 30x5 mm complete with nut, bolt and washers for mounting the junction box on street light pole complete all as specified and directed. Make:- SINTEX RAL7035 SIL-EV322 or as equivalent as per approval by GE.
122Supply & fixing PVC insulated aluminium conductor 2.5 Sqmm 2 Core cable with 1x2.5 sqmm PVC instulated aluminium conductor asearth wire for service connection of street light from junction box of LTelectric pole complete all as specified and directed. Including dismantling old unserviceable cable. Complete all as specified and directed.
123Supply & fixing PVC insulated aluminium conductor 10 Sqmm 2 Core cable with 1x10 sqmm PVC instulated aluminium conductor asearth wire for service connection of street light from junction box of LTelectric pole complete all as specified and directed. Including dismantling old unserviceable cable. Complete all as specified and directed.