| 1 | AC AMC |
| 2 | OD27838/2023-2024:Annual Maintenance and servicing of 1TR/ 1.5TR/ 2TR/ 3 TR, 240/415V , High Wall/ Floor Mounting type Split / Ductable split/ Cassette type Air Conditioner Units covering all routine and preventive maintenance , attending to all breakdowns and rectifying the defects if any (excluding the cost of spare). The cleaning and servicing of IDU and ODU includes 1No. water servicing using chemicals, water pump etc. and 3 Nos. Air servicing using cleaning materials and pressure air pump etc. The operating status of the units should be regularly monitored and intimated to the department staff in charge and the Air conditioner Units should be maintained in proper working condition through out the period of contract. |
| 3 | OD27839/2023-2024:Supply and renewing of 2 Pole Power Contactor 12A AC 3 contactor for 1TR/ 1.5TR in place of the existing faulty ones and giving connections etc as required |
| 4 | OD27841/2023-2024:Supply and renewing of 2 Pole Power Contactors 18/22A AC 3 contactor for 2TRin place of the existing faulty ones and giving connections etc as required |
| 5 | OD27840/2023-2024:Supply and renewing indoorPCB board suitable for 1TR/1.5 TR/2TR air conditioner in the place of defective one |
| 6 | OD27842/2023-2024:Supply and renewingcopper condensing coil suitable for 1TR/1.5TR/2TR air conditioner unit in the place of defective one |
| 7 | OD27844/2023-2024:Supply and replacesensor suitable for 1TR/1.5TR/2TR/3TR air conditioner unit in the place of defective one. |
| 8 | OD27845/2023-2024:Supply and providing the following rubberized foam sleeve 10mm thick, brazing, leak testingin the existing copper pipe between indoor and out door 1/4 and 1/2, 3/8 and 3/8, 5/8 etc.:- rubberized foam sleeve |
| 9 | OD27846/2023-2024:Supply and providing the following size soft drawn copper pipe for extending the pipe betweenout door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testingetc.:- 3/8 inch (9.52 mm) and 5/8 inch (15.8 mm) 22 gauge |
| 10 | OD27847/2023-2024: Supply and renewing Running Capacitor 36 MFDforAC unit -1/2 TR in place of the existing faulty ones and giving connections etc as required. |
| 11 | OD27848/2023-2024:Supply and renewing Fan MotorCapacitorfor )1/1.5/2/3 TR AC unit-10 MFD (Out door motorin place of the existing faulty ones and giving connections etc as required. |
| 12 | OD27849/2023-2024:supply and renewingcapacitor 4 mffor 1TR/1.5TR/2TRair conditioner unit in the placedefective one. |
| 13 | OD27850/2023-2024:Supply and renewing ofOscillation motor for 1TR/1.5TR/2TR/3TR air conditioner unit in the place of defective one |
| 14 | OD27851/2023-2024:Supply and renewing ofoutdoor fan motor suitable for 1TR/1.5TR/2TR air conditioner in the place of defective one |
| 15 | OD27852/2023-2024:Charges for filling sufficient quantity of Freon 22/32/410A gas for existing air conditioner unit including leak testing rectifying the defects leak arresting including breezing and make the compressor in good working condition for the following. 1TR/2TR/3TR |
| 16 | OD27853/2023-2024:Supply and fixing of 25 mm dia pvc drain water pipe and along with all required accessory insurface/recess including cutting the wall and making good the damages etc,as required |
| 17 | OD27854/2023-2024:Painting of inner and outer side of the ODU ofAir conditioning unit in installed position with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent etc.and checking all connection, and petty repairs etc as required. |