Tender For Revamping Of Cascade Chiller And Allied Works At Barc Mysuru, mysuru-Karnataka

Bhabha Atomic Research Centre has published Tender For Revamping Of Cascade Chiller And Allied Works At Barc Mysuru. Submission Date for this Tender is 27-10-2023. Chilling Plant Tenders in mysuru Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

40105379
Tender For Revamping Of Cascade Chiller And Allied Works At Barc Mysuru
Open Tender
Indian
Karnataka
Mysuru
27-10-2023

Tender Details

Tender For Revamping Of Cascade Chiller And Allied Works At Barc Mysuru; 1 Cascade Chiller Spares List : 2 4 Dial Ss Case Freon Gauge Glycerin Filled Ss Internals And 3 / 8 Bsp Brass Connection Range:-30X300 Psi And -30X500psi 3 A ) Back Panel Mount - Supply 4 A ) Back Panel Mount - Installation 5 B ) Bottom Direct Mount - Supply 6 B ) Bottom Direct Mount - Installation 7 C ) Bottom Surfacxe Mount - Supply 8 C ) Bottom Surfacxe Mount - Installation 9 Supply Of Pressure Switch, Indfos / Wika Make, Range:- -30 Cmhg To 7 Atmg, Model:- Psm 690 L2 2 A / Mp 1A 10 Installation Of Pressure Switch, Indfos / Wika Make, Range:- -30 Cmhg To 7 Atmg, Model:- Psm 690 L2 2 A / Mp 1A 11 Supply Of Johnso Thermostat ( Low Limit Thermostat ) Model:A19abc - 24 ( ( -30°C To -65°C ) 12 Installation Of Johnso Thermostat ( Low Limit Thermostat ) Model:A19abc - 24 ( ( -30°C To -65°C ) 13 Supply Of Interstage Thermostat ( -20°C To -40°C ) 14 Installation Of Interstage Thermostat ( -20°C To -40°C ) 15 Resistance Temperature Detector Model: Pt 100 16 Supply Of Temperature Sensor Pt 100 Probe Length 75Mm Wire 17 Installation Of Temperature Sensor Pt 100 Probe Length 75Mm Wire 18 Supply Of Temperature Sensor Pt 100 Probe Length 180Mm Wire 19 Installation Of Temperature Sensor Pt 100 Probe Length 180Mm Wire 20 Supply Of Expansion Valve Tes 2 3 / 8 For R404a ( 068Z3403 ) 21 Installation Of Expansion Valve Tes 2 3 / 8 For R404a ( 068Z3403 ) 22 Supply Of 1 / 2 Filter Drier Danfoss Make Model: Dml 304F Or Equivalent 23 Installation Of 1 / 2 Filter Drier Danfoss Make Model: Dml 304F Or Equivalent 24 Supply Of 1 / 2 Filter Drier Danfoss Make Model: Dml 304S Or Equivalent 25 Installation Of 1 / 2 Filter Drier Danfoss Make Model: Dml 304S Or Equivalent 26 Vibration Eliminator ( Post Compression ) Of Danfoss Make Or Equivalent 27 Supply Of Outer Dia. 32 Mm ( Inlet / Outlet ) 28 Installation Of Outer Dia. 32 Mm ( Inlet / Outlet ) 29 Supply Of Outer Dia. 26 Mm ( Inlet / Outlet ) 30 Installation Of Outer Dia. 26 Mm ( Inlet / Outlet ) 31 Supply Of 1 1 / 8 ( 28 Mm ) Oil Seperator Danfoss / Henry / Bos Make 32 Installation Of 1 1 / 8 ( 28 Mm ) Oil Seperator Danfoss / Henry / Bos Make 33 Supply Of Pressure Switch, Indfos / Wika Make, Range:-6 To 3 Atmg, Model:- Psm 690 H3 1 M / Mp5r 34 Installation Of Pressure Switch, Indfos / Wika Make, Range:-6 To 3 Atmg, Model:- Psm 690 H3 1 M / Mp5r 35 Supply Of Pressure Switch, Indfos / Wika Make, Range:- -6 To 30 Bar, Model:- Psm 520 400 / Ips400 36 Installation Of Pressure Switch, Indfos / Wika Make, Range:- -6 To 30 Bar, Model:- Psm 520 400 / Ips401 37 Supply Of Dml-165 Oil Filter Drier Of Danfoss Make, 5 / 8 End Connections 38 Installation Of Dml-165 Oil Filter Drier Of Danfoss Make, 5 / 8 End Connections 39 Supply Of Dml-165 Oil Filter Drier Of Danfoss Make, 16 Mmend Connections. 40 Installation Of Dml-165 Oil Filter Drier Of Danfoss Make, 16 Mmend Connections. 41 Supply Of Pressure Relief Valve ( 0 To 12 Bar ) , See Enclosed Drawing For More Details. 42 Installation Of Pressure Relief Valve ( 0 To 12 Bar ) , See Enclosed Drawing For More Details. 43 Supply Of Safety Relief Valve ( 0 To 5 Bar ) , See Enclosed Drawing For More Details. 44 Installation Of Safety Relief Valve ( 0 To 5 Bar ) , See Enclosed Drawing For More Details. 45 Supply Of Thermostatic Expansion Valve Suitable For ( R23 / R508b ) . See Enclosed Drawing For More Details. 46 Installation Of Thermostatic Expansion Valve Suitable For ( R23 / R508b ) . See Enclosed Drawing For More Details. 47 Supply Of Crank Case Heater Of 400 Watt Capacity, Heating Element Length Shall Be 4 To 6 Inch. 48 Installation Of Crank Case Heater Of 400 Watt Capacity, Heating Element Length Shall Be 4 To 6 Inch. 49 Solenoid Coils Of Following Sizes 50 Supply Of Coil Inner Dia. 15.2 Mm, 10 Watt, 230V Ac 51 Installation Of Coil Inner Dia. 15.2 Mm, 10 Watt, 230V Ac 52 Supply Of Coil Inner Dia. 13.5 Mm, 12 Watt, 230V Ac 53 Installation Of Coil Inner Dia. 13.5 Mm, 12 Watt, 230V Ac 54 Supply Of Coil Inner Dia. 10 Mm, 10 Watt, 24V Dc 55 Installation Of Coil Inner Dia. 10 Mm, 10 Watt, 24V Dc 56 Supply Of Water Flow Switch Of 0 To 10 Bar Range, End Connections One Inch Pipe Thread, Honeywell Make 57 Installation Of Water Flow Switch Of 0 To 10 Bar Range, End Connections One Inch Pipe Thread, Honeywell Make

Key Value

Document Fees
Refer document
EMD
INR 8460.0 /-
Tender Value
INR 4.23 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail