Replacement Of Damage Cable And Feeder Pillars Of Dispensary, Community Centre , Tube Well No. 3. (Electrical Works) Replacement Of Damage Cable And Feeder Pillars Of Dispensary, Community Centre ,Tube Well No.-3. (Electrical Works)
BOQ
| Sl. No. | Item Description |
| 1 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. CI/MS cover plate hinged to frame with locking arrangement-01 No.,Charcoal-96.00 KG, Salt-5.00 kG, Common burnt clay F.P.S.-50 Nos.) and Earthing pit depth- 12\"-15\" with all etc. as required. |
| 2 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required |
| 3 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing pipe etc. as required. |
| 5 | Above 35 sq. mm and upto 95 sq. mm |
| 6 | Above 95 sq. mm and upto 185 sq. mm |
| 7 | Providing and laying position cement concrete 1 : 2 :4 (1 cement : 2 Courase sand: 4 graded stone aggregte 20 mm nominal size)in foundation of pump, DG set, panels etc. Including form work etc. As required. |
| 8 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required |
| 9 | 150 mm dia |
| 10 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required |
| 11 | 3½ X 70 sq. mm (38mm) |
| 12 | 3½ X 120 sq. mm (45mm) |
| 13 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 14 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 15 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 16 | Supplying and laying of following size ISI marked PVC insulated and PVC sheathed/XLPE /FRLS (Flame proof, water proof) aluminium conductor steel armoured cable of 1.1KV grade as required. |
| 17 | 3.5 x 70 sq mm |
| 18 | 3.5 x 120 sq mm |
| 19 | Supplying & febrication,installation,testing and commissioning of 4 poles,LT Outdoor panel with double wall housing with spacing about 6 inchs with each other (Duble wall cubical panel for environmental protection) made of 2 mmthick CRCA-MS sheet suitable housing(1200 MM X 900 MM) of 500 mm deep with mounting arrangement, 1000 A 4 STRIP Aluminioum busbar duly sleeved making suitable hole for cable entries detachble gland plates at bottom painting with supierior quaility . bus bar with heat shirnk sleeves etc, dust and vermin proof IP 65 standred having the switch gears and metering facility compelete with connections & inter connections painting etc.as required. (Every seperate feeder name plate fabrication and installation work and about 4-5 feet height solid high quality angle iron stand is also included in this Item). The panel must be factory fabricated.The drawing of the panel fabricated and after fabrication the same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. INCOMING:-A. 250 A,Four Pole MCCB adjustable thermal & adjustable magnetic setting, Breaking capacity 25 KA,-01 No. OUTGOING:- A..250 A,Four Pole MCCB, 25 Ka -01 No. 200 A,Four Pole MCCB,Breaking cap-25 kA-01 No. Note:- Dismentaling the old panels, Cables & switchgears and fixing of new panels, all cable and Supplying & fixing of new switchgears Installaton, testing snd commissionning & other fixing works are included with the same. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender