Border Security Force-BSF has published Tender For Construction Of 8 Bedded Mahila Barrack At Bop Ramnagar Of 08 Bn Bsf Under Shq Bsf Krishnanagar Sh Ei Fans Solar Plant Solar Water Heater. Submission Date for this Tender is 12-10-2023. Electrical Maintenance Tenders in Nadia West Bengal. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group "B" |
2 | Wiring for light/ power plug with 2X4 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
3 | Wiring for light/ power plug with 4X4 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 1.5 Sq. mm + 1 X 1.5 Sq. mm earth wire |
5 | b) 2 X 6 Sq. mm + 1 X 6 Sq. mm earth wire |
6 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (i)3 x 1.5 sq. mm |
7 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 A switch |
8 | b) 3 pin 5/6 A socket outlet |
9 | c) Telephone Socket Out let |
10 | d) TV antenna socket outlet |
11 | Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
12 | Supplying and fixing of 1 or 2 Module (75 mm X 75 mm)size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
13 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
14 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
15 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
16 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. |
17 | Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
18 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) a) 12 way double door |
19 | b) 16 way double door |
20 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
21 | Supplying and fixing Cable End Boxes (IP 43) suitable for 14 way, Double door SPN MCBDB, 240 volts, on surface/ recess, complete with testing and commissioning etc. as required. |
22 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
23 | Earthing with G.I.earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and wateringpipe of 2.7 mtrs long etc. with charcoal or coke and salt complete as required. |
24 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
25 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
26 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
27 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, GI tube, having single prong at top with 85 mm dia 6 mm thick GI base plate including holes etc complete as required. |
28 | Jointing of copper/GI tape (with another copper/GI tape, base of the finial or any other metallic object) by reveting/ nut bolting/ sweating and soldering etc as required. |
29 | Providing and fixing of GI tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
30 | Providing and fixing of GI tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required (For vertical run) |
31 | Providing and fixing testing joint, made of 20 mm x 3 mm thick GI strip, 125 mm long, with 4 nos of GI bolts, nuts, check nuts and spring washers etc compete as required. |
32 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3.5 x 35 Sqmm |
33 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. (a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
34 | Supplying & laying of one numberXLPE insulated and PVC sheathed, armoured aluminium power cable of 1.1 KV Grade of size3.5X35 Sq. MM conf to IS: 7098 (Part-I), direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. |
35 | Supplying & laying of one numberXLPE insulated and PVC sheathed, armoured aluminium power cable of 1.1 KV Grade of size 3.5X35 Sq. MM conf to IS: 7098 (Part-I) in the existingHume/METAL/PVC PIPE as required. |
36 | Supplying & laying of one numberXLPE insulated and PVC sheathed, armoured aluminium power cable of 1.1 KV Grade of size 3.5X35 Sq. MM conf to IS: 7098 (Part-I) in the existing mesonry open duct as required. |
37 | Supplying and fixing of 63 Amp, 240 Volt, 10 kA, "C" curve, double pole MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
38 | Supplying and fixing of 63 Amp, 240 Volt, 10 kA, "C" curve, Four pole MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
39 | SITC of 1200 mm sweep ceiling fan, suitable for 240 Volts 50 Hz, AC supply, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc as required. |
40 | SITC of 900 mm sweep ceiling fan, suitable for 240 Volts 50 Hz, AC supply, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc as required. |
41 | Supplying and fixing Fan Hook/ Clamps box suitable for mounting 900/ 1200 mm sweep ceiling fan etc. as required. |
42 | Supplying and fixing of 250 mm sweep,PVC Exhaust fan suitable for single phase, 50 Hz, 240 volts, AC supply in existing opening including making hole to suit the size and making connections etc. as required. |
43 | Supplying & fixing of20 watt, 4 feet,6500k environmental friendly, energy efficient, LED batten directlyon ceiling/wall, including connections etc as required. |
44 | Supplying and Fixing of 9 WLED Mirror Light, 2 feet,6500k environmental friendly, energy efficient, LED batten directlyon ceiling/ wall, including connections etc as required. |
45 | Supplying and fixing of 12 Watt, 6500K, round shaped surface mounted LED panel with premium diffuser to ensure glare free & even light distribution including connection etc as required. |
46 | Providing and fixing of 9 Watt, LEDbulb including connection etc as required. |
47 | Providing and fixing of 70 watt energy saving and environmental friendly LED street light, made up of pressure die cast aluminium housing, separate driver compartment with IP66 protection, includingSupplying and fixing of 32 mm dia G.I pipe (medium duty) bracket of 0.75 Mtr length bend to required shape on existing wall by suitable clamping arrangement for installation of 70 watt LEDlight fittingetc. as required. |
48 | Supplying and fixing of Ding-dong call bell, suitable for single phase, 230 volts, complete as required. |
49 | SITC of Solar water heaterincluding electrical heater backup optional upto 2 KW with Tank volume - 200 LPD, Inner Tank Material stainless steel, Outer tank material - power coated, collectro type- Evacuted tube collector, can handel upto 350 ppm of water hardness etc as required. |
50 | SITC of3 KW, 24Volt single phase PWM Solar power package consisting of 3.75 KVA capacity, 24 V rated solar conditioning unit 9 X 335 WP solar PV module having nominal voltage 48 V with 25 Year warranty, 04Nos, C-10 rated 12 V, 200 AH tubular solar battery with 60 month warranty including field junction box, suitable galvanized iron stand for module, interconnectionof modules and junction box through 10 Sq mm cross linked polyolefin insulated & battery through PVC insulated PVC sheathed 16 Sq mm stranded copper conductor cable including of panel G.I Pipe earthing and all accessories includingbrick work for making foundation for solar panel legs including plastering etc as required as per site requirement. The module/panel should compliance with IEC- 61215. The solar PCU unit should consists of the following:- A) Solar charger controller:- Single phase solar charge controller based on PWM technology, max input PV current 40 A, protection against overcurrent, battery overcharge, PV/ battery reverse polarity, reverse current & high temperature B) Inverter :- Solar hybrid inverter with inbuilt charge controller 3 KW, 24 V DC input and 220 V pure sine wave output at rated load 3.75 KVA @ 0.8 PF, efficiency>85%having 3 years warranty. C) Battery :- 04Nos, C-10 rated 12 V, 200 AH tubular solar battery with 60 month warranty. |
51 | Applicable rate of GST@18% (MF@1.0633) in place of 12 % on total of DSR item No.01 to 28 |
52 | Add labour cess @1% on Total |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy