Mathura Vrindavan Development Authority has published Tender For Construction Of Gate On The Road Leading To Ter Kadam At Nandgaon, Work Of Railing, Solar System, Row And Chiller Etc. In The Premises.. Submission Date for this Tender is 25-10-2023. Solar Product Tenders in Mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Excavation in foundation in ordinary soil (Loam,Clay or Sand) Including lift upto 1.50 m and lead upto 30m and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer In-charge upto a distance of 30m from the foundation trenches.(small work). |
2 | Providing and laying cement concrete in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, Including cost of form work. in Foundation and floors. |
3 | Class-150 (Non Modular) brick work in 1:4 cement and Coarse sandmortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work. |
4 | 12mm thick plaster with cement mortar of1:4 cement and coarse sand ofsingle coatfor interior plastering up to floor two level including internal rounded angles chamfers and rounded angles not excluding 80mm in girth and finished even and smooth. |
5 | Providing and laying cement concrete in 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) (not less than strength of M-10 concrete )and curing complete, Including cost of form work. in Foundation and floors. |
6 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
7 | 13.50 Applying priming coat: 13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 13.61.1 Two or more coats on new work |
8 | 11.26 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 11.26.1 25 mm thick |
9 | 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. sqm 1810.05 |
10 | R.C.C. work Providing and laying in position specified grade of R,C,C, including the cost of centering,shuttering,finishing & excluding of reinforcement. 1:1.5:3(1cement:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal sizeAll works upto plinth level. |
11 | Above Plinth Level Up to Floor V Level |
12 | Reinforcement of reinforced concrete reinforced concrete or reinforced brick work (When not included in and an over all rates) brought to required shape as necessary including bending for proper completion of the work and including the supply of steel and its wastage Bend, hooks and authorized over lapping shall be measured upto floor to level.(FE500). |
13 | Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. |
14 | Stone work plain ashlar in arches in super structure upto floor V level in cement mortar 1:3 (1 cement : 3 coarse sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. Both face dressed Red sand stone |
15 | Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : Triangular or Square or rectangular pillars |
16 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) with joints finished flush. |
17 | Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. |
18 | Red Sand Stone work for wall lining etc. (Veneer work) 30mm thick in cement mortar 1:3 (cement:coarse sand) including camping jointing in white cement mortar 1:2 (white cement:stone dust)with an admixtureof pigment matching the stone shade |
19 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
20 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete Wedge expansion type Fastener with threaded dia 6 mm |
21 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (MARBLE WORK) |
22 | 70 mm thick rubbed red sand stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. |
23 | Extra for stone work ashlar sunk or moulded in cornices. |
24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm nominal outer dia pipes |
25 | SOLAR ENERGY SYSTEMS.I.T.C of Solar System (10 KW )complete in all respect,consisting of following parts :- 1- PV Module 250 kwp2-NOS.OF Panels-403-Solar PCU (Inverter) 10 KW 4-Batteries-105-Space required 80 sq meter6-Mounting Structure-5 |
26 | Maintenance of the solar system five year Including batteries replace |
27 | RO SYSTEM Supply and fixing RO system 1000 per hours capacity |
28 | SITC of 1000 litre Chiller plant including storage tank of 1000 litre |
29 | 1311(B) Supply and wiring of submain with two number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in (2mm thick) PVC conduit with one number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit on surface, complete in all respect. |
30 | P/F of 6Amp to 32 Amp SPMCB (10 kba) C Curve Categary A PWD 2018 (E)/1002 |
31 | 212(B) Supply and wiring of submain with two number 6 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage rigid steel conduit on surface, with one number 14 SWG copper earth continuity wire etc., complete in all respect. 212(C) As in item no. 212 (B) but in 25mm dia heavy duty (2mm thick) PVC conduit with one number 4 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. |
32 | Supply and burring of Safe Earthing Electrode T-39 Zn- Zinc Coated, Length 3000mm, outer pipe 76.3mm x 3.2 inner pipe 42.4mm x 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25 x 3 G.I. Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. |
33 | S&F of 100 Amp. four pole change over switch on 40mm x 40mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. |
34 | 1026 (C) S & F surface/Flush mounting 4ways V TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. CAT A |
35 | 1020 (A) S&F of 63 Amp. 4 pole MCB(10 KA) C Curve CAT A each 2290.00 |
36 | 1011 S&F of 63 Amp. DP MCB (10 KA) CAT A |
37 | 1026 S & F surface/Flush mounting 4ways TPN distribution board without additional Door without MCB complete in all respect, as directed at site by Engineer in charge. CAT A |
38 | 328 S&F of 100 Amp. 415 V metal clad TPN HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect. Cat. B. |
39 | Less 5% on overall BOQ Amount ( X ) as per govt. Approval NOTE : d`r dk;Z dh ek=k fu/kkZfjr ekudksa ds vo:Ik gksxh rks leku dk;Z dk rkRi;Z flfoy rFkk bysfDVªd eSdsfudy ds lHkh dk;ksZa ls ekuk tk;sxk A |