Supply Installation Testing Commissioning Of 250 Kva Dg Set With Amf Panel Board In Kmc Office Kmc, kollam-Kerala

Local Self Government Department has published Supply Installation Testing Commissioning Of 250 Kva Dg Set With Amf Panel Board In Kmc Office Kmc. Submission Date for this Tender is 13-10-2023. Diesel Generators Tenders in kollam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

40063056
Supply Installation Testing Commissioning Of 250 Kva Dg Set With Amf Panel Board In Kmc Office Kmc
Open Tender
Indian
Kerala
kollam
13-10-2023

Tender Details

Supply Installation Testing Commissioning Of 250 Kva Dg Set With Amf Panel Board In Kmc Office Kmc

Key Value

Document Fees
INR 2500 /-
EMD
INR 50000.0 /-
Tender Value
INR 28.64 Lakhs /-

BOQ Items

Work Name:Annual Plan-SITC of 250 KVA DG set with AMF panel board in KMC Office -KMC -General Electrical Work
Sl. No. Item Description
1Electrification
2OD914/2023-2024:Supply, conveyance, Installation, testing & commissioning of 250 KVA Diesel Generator set with AMF PROVISION Panel with integral acoustic enclosure as per CPCB norms with standardised accessories as per technical details given below. 1. Engine : a) Make of Engine - Kirloskar//Cummins/Leyland/Volvo b) Type of Engine - Diesel Engine c) No. of Cylinders - As per manufactures standards. d) Method of Cooling - Water cooled with radiator. e) Design - Suitable for generating set operation 2.Standard accessories with Diesel Engine a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d) Radiator with fan provided with fan guard. e) Fuel Pump f) Fuel filter g) Lubricating oil filter h) Exhaust silencer i) Exhaust Muffler j) Battery Charger/Generator 3. Engine Instrument Panel with the following items a) Starting switch with key or button b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPM Indicator with hour meter e) Battery charging Ammeter 4. Safety Controls for Engine a) Trip for low lubricating oil pressure b) Trip for high water temperature. 6. Brushless Alternator a) Make - Kirloskar/KEL//Stanford/LS b) Type - Self exited and self regulated. c) Capacity - 250 KVA/200 K W @ 0.8PF d) System of Voltage - 3 phase, 415 V, e) Frequency - 50 Hz f) Insulation - Class F/H The Alternator should confirm to IS 4722. Operation and service manual, spares and tools shall be provided. 7. Fuel Tank Suitable size built in type integrated with the acoustic enclosure Fuel connection shall be done as per standards 8. Battery Suitable size built in type integrated battery with leads and terminals of appropriate AH capacity as per Manufactures requirement. Automatic Battery charger Solid state phase indication lamp for supply ON/OFF with HRC protection. standard conrol panel as per kerala Electrical Inspectorate requirements, with 400A 4 pole MCCB and accessaries such as Multi function metre and seperate Energy metre etc.Complete.
3OD924/2023-2024:Supply and providing the following size of B class MS pipe conforming to relevant IS :1239 PART-1 (2004) specifications complete with heavy gauge specials such as bends, flanges etc welded and fixed at appropriate locations providing cork sheet in between the flanges at the joints, bolting the flanges together, painting the pipe, flanges etc with 2 coats of heat resistant paint suitable for outdoor applications fixing the pipe firmly with fabricated structure/ mechanical support etc as required 100 mm dia.
4OD1188/2023-2024:Supply and providing the following size of B class MS pipe IS:1239 PART-1 (2004) conforming to relevant IS specifications complete with heavy gauge specials such as bends, flanges etc welded and fixed at appropriate locations providing cork sheet in between the flanges at the joints, bolting the flanges together, painting the pipe, flanges etc with 2 coats of heat resistant paint suitable for outdoor applications fixing the pipe firmly with fabricated structure/ mechanical support etc as required 150 mm dia
590.12.2.34:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including wideningthe trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 185 sq mm
65.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
71.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
890.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
990.16.4.8:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip
1090.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
119.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
12OD1354/2023-2024:Supply and fixing Danger notice board of size, 125 x 75 mm
13OD1393/2023-2024:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
14OD1390/2023-2024:Supply and providing 6kg dry chemical powder type fire extinguisher with accessories fixed on wall in position
15OD1389/2023-2024:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of redoxide and written with white paint 'FIRE', filled with fine sand, mounted on existing MS angle frame work / wall bracket etc. as required
16OD1402/2023-2024:Supply of HSD for testing of the DG set including loading at the fuelpump,conveyance,unloading at site,filling in the tank etc
17OD1401/2023-2024:Supply and providing 2.5mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength including fixing with suitable synthetic adhesive,
1814.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
1914.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
20OD6445/2023-2024:steel reinforcement for RCC work including straightening, cutting , bending, placing in position and binding all complete upto plinth level.
2114.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
2214.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
2390.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
24OD1395/2023-2024:Copying charges of Electrical/fire Drawing per A3 sheet additional copies
25OD1394/2023-2024:Charges for preparation of Electrical/fire Drawing per A3 sheet first copy
2690.12.6.36:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 300 sq mm
274.1.4:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
289.1.30:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)
29OD5664/2023-2024:SITC of AMF control system using c and s Amf relay and should work both in auto mode and manual mode -Supply, installation , testing and commissioning of totally enclosed compartmentalized dust and vermin proof cubical segregated and modular in construction M.V. panel board (1.5m*2.2m*0.4m)free standing fabricated with14swg and 16swg of CRCA M.S. sheet, powder coated , bus-bar chamber ,outgoing switchgear etc. (all feeder unit Would be compart mentalized), color coded PVC sleeved vertical / horizontal Aluminium busbar of required size of length, ( bus-bar distances shall be minimum 32 mm ) insulators, hardware, neoprene gasket , hinged door, interconnecting single core multi strand lugged copper wire having current density of 2A / sqmm of suitable capacity & size with lugs from busbar to switchgears / MCCB / MCB or where ever required, control wiring with 1.5 sqmm FRLS cable, ON/OFF, RYB phase indicators, two earthing terminal busbar of size 25 x 5 mm copper with nut & bolts at outside of the panel, rating and name plates for all incoming & outgoings etc comprising with the followings as per the KE standard. Switch gears : L&T/ Equivalent, standard. Switch gears : L&T/ Equivalent, Contactors : L&T /Equivalent.etc complete. Electrical interlock should be provided for both incomers.
3090.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)