}

Tender For Purchase Of Lab Equipments , Equipment To Chemistry Department , Flame Photometermicro Controller Based Flame Photometer With Auto Ignition Instrument Should Havedetermination Up-To Three Elements With Single Aspiration Calibration Standar, palakkad-Kerala

Government College-GC has published Tender For Purchase Of Lab Equipments , Equipment To Chemistry Department , Flame Photometermicro Controller Based Flame Photometer With Auto Ignition Instrument Should Havedetermination Up-To Three Elements With Single Aspiration Calibration Standar. Submission Date for this Tender is 21-10-2023. Laboratory Equipment Tenders in palakkad Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

40060392
Tender For Purchase Of Lab Equipments , Equipment To Chemistry Department , Flame Photometermicro Controller Based Flame Photometer With Auto Ignition Instrument Should Havedetermination Up-To Three Elements With Single Aspiration Calibration Standar
Open Tender
Indian
Kerala
palakkad
21-10-2023

Tender Details

Purchase Of Lab Equipments , Equipment To Chemistry Department , Flame Photometermicro Controller Based Flame Photometer With Auto Ignition Instrument Should Havedetermination Up-To Three Elements With Single Aspiration Calibration Standard Up-To Five Point. Auto Ignition And Auto Gas Cut-Off Gas Leak Sensor Separate Login For Administrator And Guest Results Of A Measurement Taken Earlier Can Be Recalled And Displayed (Max.Results Storage: 500) Graphics Lcd Readout (240 X 128 Dot) Lcd Readout Online Reading Facility Sensitivity Of Calibration Elements Minimum(Ppm) Maximum(Ppm)Curve Fitting Accuracy : + 2% On Full Scale Filters Na, K, Ca, Lisample Volume: Approx. 3Mlaspiration Time: Five Element Analysis Within 20 Second On Single Aspiration Accessories: Glass Beaker 10 Number, Compressor, Gas Valve, Instruction Manual. Warranty 3 Years , Ph Meterph Range 0 To 14, Resolution 0.001Ph, Temperature 0 To 99 Deg Celsius, Glass Electrode With Temperature Sensor. Warranty 3 Years , Digital Conductivity Meter Conductivity Range-0 Micro S To 200 Ms, Accuracy 0.1 Micros, Temperature 0 To 100 Deg Celsius. Warranty 3 Years , Digital Potentiometer Mv 0 To 1999 Mv, Temp 0 To 100 Deg Celsius, Platinum Electrode, Reference Ag/Agcl Electrode Temperature Range 0 To 100 Degree Celsius. Warranty 3 Years , Four Digit Electronic Balance 0.0001G Resolution (0.1Mg), 4-Digit Electronic Weighing Balance Capacity: 220Gx0.1 Mg Scale, Readability 0.1 Mg, Linearity(+/-) 0.2Mg Calibration Internal, Accuracy 0.1Mg, Pan Size 90 Mm. Warranty 3 Years , Equipment To Physics Department , Searles Vibration Magnetometer - Vibration Magnetometer Suitable For Comparison Of Magnetic Moments And Magnetic Fields - Type: Vibration - Size: Customized Backed By Rich Industry Experience, We Are Affianced In Providing A Qualitative Assortment Of Vibration Magnetometer That Is Suitable For Comparison Of Magnetic Moments And Magnetic Fields. , Optical Fiber Charecteristics Apparatus:To Find The Numerical Aperture, Attenuation And Bandwidth Of Optical Fibers: Laser Source, Powersupply, Adapter , And Function Generator, Two Fibers Of Dfferent Legth, Ldr Detector, Optical Voltmeter, Graduated Screen , Fiber Coupler Mounted On Translation Stage. , Torsion Pendulum - Steel Disk20 Cm Diameter, With Pair Ofadjustable Chuck Nuts, Brass Wire Of 100Cm Length And 1.5 Mm Diameter, Steel Wire 100Cm Legnth And 1Mm Diameter, Pair Of Identical Mass, And Stand With Heavy Base And Length Of 90 Cms Height , Travelling Microscope - Three Axis Measurement Possibility: Horizontal, Vertical And Right Angled Transverse Motion, Coarse And Fine Movements,Resolution Of The Fine Movement: 10 Micron, Rack And Pinion Type Focusing Mechanism,3X Long Working Distance Objective And A 10X Eyepiece With Cross Hair,Achromatic Type Objective, Base Construction : Cast Aluminium,Only High Quality Makes Need To Be Quoted , Lamp And Scale Arrangement (With Telescope)- Vertical Arrangement, Transformer, For Use With 220 Volts, Good Quality Make , Scale And Telescope With Stand For Both , Mercury Vapour Lamp - (1)Lamp House • Made Of Rectangular Steel Tubes • With Proper Mounting For Cables • Bulb And Holder • Adjustable Light Output Port • With Fixed Height From The Base (2)Transformer (3)Power Supply Warranty For Lamp And Power Supply , Sodium Vapor Lamp - (1)Lamp House • Made Of Rectangular Steel Tubes • With Proper Mounting For Cables • Bulb And Holder • Adjustable Light Output Port • With Fixed Height From The Base (2)Transformer (3)Power Supply Warranty For Lamp And Power Supply , Induction Heater (For Doing Heat Experiments) High Quality Full Glass Panel, Upto 2100 W, Preset Timer And Sensor Touch , Gm Counter- Radiation Counting System With Alpha/Beta And Gamma Probes. Should Provide Alpha,Beta And Gama Sources. Also Absorber Kit And Necessary Accessories For Carrying Out A Number Of Nuclear Physics Experiments Such As Characteristics Curve Of A G.M. Counter, To Verify The Inverse Square Law For Gamma Radiation, Absorption Of Beta Radiations, Efficiency Of G.M.Counter For Beta Radiation, Determination Of The Back Scattering Factor Of A Material For Beta Rays Etc,. Shouls Also Provide Lead Storage Container. Specifications G.M. Input (From G.M.Counter)(A) Polarity : Negative (B) Amplitude : 250 Mv (Min), Resolving Time6 Micro Sec (Approx), Hv Output:Variable Hv Using Tenturn Pot Upto A Maximum Of 1500 Volts At 1 Ma. Line And Load Regulation Better Than 0.05%. Ripple Less Than 10Mv (Rms). Display: 20 X 2 Lcd Dotmatrix Display Has Been Provided To Indicate Data Counts, Elapsed Time And Hv. Counts Capacity : 999999 Counts Preset Time(0-9999) Sec., Command Buttons: Start, Stop, Prog, Store, Inc & Dec Command Buttons Have Been Provided On The Front Panel Key Pad. Programmability: Includes Selection Of Preset Time, Storing / Recalling Of Data, Starting And Stopping Of Acquisition Etc,. G.M. Socket: Mhv Connector For Connecting To G.M. Detector. Power: Unit Is Powered Works On 230V, Ac, 50Hz Through Power / Adapter Which Delivers +12V Input To Unit. Mechanical Dimensions: 236Mm(W) X 133Mm(H) X 246Mm(D) Approx. , Electronic Balance - With Precision Of 0.001Gram, Diameter Of 10-15 Cm Balance Pan, Transparent Sheild And Sliding Doors, Tare Button, Level Adjust, And Display , Digital Outside Micrometre- Range 0-25 Mm, Resolution 0.001Mm, Range 0-1 Inch , Micrometer Screw Gauge (Stainless Steel) - Type: Analog, Measuring Range: 0-25Mm, Accuracy: 0.001Cm, Only High Quality Make Need To Be Quoted , Vernier Callipers - Stainless Steel, Measuring Range: 450 Mm,Accuracy: 100%, Display Type: Analog, Only High Quality Make Need To Be Quoted , Transistor Characterestics Apparatusfor Common Emitter Configuration- Two Regulated Dc Power Supplies, One Is 0-1 Volt And Other Is 0-10 Volts. 1Pnp & Npn Transistor With Three Terminals For Base, Emitter & Collector. Four Deluxe Quality Moving Coil Type Meters, Two Meters Are For Measurement Of Different Voltages And Other Two Are For Measurement Of Different Currents. 1St Meter 0-1V For Measurement Of Base Voltage (Input) (Vb), 2N D Meter 0-1/10V (Double Range) For Measurement Of Collector Voltage (Output) (Vc).3Rd Meter 0-250?A/25Ma (Double Range)For Measurement Of Base Current. (Ib). 4Th Meter 0-25Ma For Measurement Of Collector Current. (Ic). Connecting Chords. , Ballistic Galvanometer - For Low Current Measurement. Leveling Screws For Balancing The Coil. Coil With Mirror Suspended Between The Long Suspension At The Upper End And A Spring At The Lower End. Suspension And Spring Made Of Special Alloy( Phosphor -Bronze) To Provide High Degree Of Sensitivity To The Movement. Movement Housed In A Bakelite Case. Resistance 500 Ohm, Time Period - 12 S, Charge Sensitivity - 600Mm/?C, Current Sensitivity - 1400Mm/?A, Critical Damping Resistance - 3500 O , Compass Box ( 10 Cm Diameter) , Permanent Bar Magnets 7.5Cm X 1.5 Cmx1cm , Steel Cylindrical Die : 14 Mm Diameter Can Go Upto 100 Megapascal , Digital Stop Watch , Jeagers Apparatus-For Measuring The Surface Tension Of A Liquid At Different Temperatures- Full Set , Equipment To Zoology Department , Refrigerator 190 L Single Door , Binocculars 42 Mm Objective Diameter Bak 4 Roof Prismwide Angle View 6.8 0 , 60X60 High -Definition Dual -Tube Night Vision Telescopemonocular , Smartphone Attached Macrolens , Calorimeter , Weighing Balance (1Mg) , Induction Cooktop , Micropipette 100-1000 Variable , Micropipette 10-100 Variable , Tabletop Centrifuge 5Krpm (15 Ml Tube) , Micropipette 20-200 Variable , Micropipette 2-20 Variable , Haemoglobinometer , Haemocytometer , Equipment To Botany Department , -20 Lab Deep Freezer 200L , Spectrophotometer (Uv/Vis)Manufacturer Should Be An - Iso 9001 : 2015Certified Company-Features -Photometric Analysis, Quantitative Analysis, Spectral Scanning, Kinetics, Dna/Protein Analysis, Multi-Wavelength Test, Etc.-Data Storage – Minimum 150 Test Data And 50 Standard Curves;-Wavelength Range 190~1100Nm-Spectral Bandwidth 2 Nm-Wavelength Accuracy 1Nm-Wavelength Repeatability <=0.2 Nm-Photometric Accuracy 0.5%T-Photometric Repeatability 0.2%T-Photometric Range 0 - 200%T, - 0.3 - 3A-Stray Light 0.15%T-Stability ±0.0002A/H @500Nm-Baseline Flatness ±0.002 A-Noise ±0.001 A-Automatic Wavelength Setting -Grating 1200 Lines/Mm-Light Source -Deuterium & Tungsten Lamp-Displaylcd With Backlit -Detector -Silicon Photodiode-Output Usb Port Orparallel Port -Printer Support Is Preferable -Power Ac 220V/50Hz; Ac 110V/60Hz-Approximate Dimension 500*500*250Mm-Standard Accessories-2 Glass Cell , 2 Quartz Cell, Software -Weight Should Be Less Than 20 Kg -Onsite Installation -Supplier Should Have Service Facility In Kerala

Key Value

Document Fees
INR 2124 /-
EMD
INR 6000.0 /-
Tender Value
INR 6 Lakhs /-

BOQ Items

Name of Work: PURCHASE OF LAB EQUIPMENTS TO VARIOUS DEPAERTMENTS
Sl. No. Item Description
1EQUIPMENT TO CHEMISTRY DEPARTMENT
2Flame photometerMicro controller based Flame photometer with auto ignition Instrument should haveDetermination up-to Three elements with single aspiration Calibration standard up-to five point. Auto Ignition and Auto Gas cut-off Gas leak sensor Separate login for Administrator and Guest Results of a measurement taken earlier can be recalled and displayed (Max.Results storage: 500) Graphics LCD readout (240 x 128 Dot) LCD readout Online reading facility Sensitivity of calibration Elements Minimum(ppm) Maximum(ppm)Curve fitting accuracy : + 2% on full scale Filters Na, K, Ca, LiSample volume: Approx. 3mlAspiration Time: five element analysis within 20 second on single Aspiration Accessories: Glass beaker 10 Number, Compressor, Gas valve, Instruction manual. Warranty 3 years
3pH MeterpH range 0 to 14, resolution 0.001pH, temperature 0 to 99 deg celsius, Glass electrode with temperature sensor. Warranty 3 years
4Digital Conductivity meter Conductivity range-0 micro S to 200 mS, accuracy 0.1 microS, Temperature 0 to 100 deg Celsius. Warranty 3 years
5Digital Potentiometer mV 0 to 1999 mV, Temp 0 to 100 deg Celsius, Platinum electrode, Reference Ag/AgCl electrode temperature range 0 to 100 degree celsius. Warranty 3 years
6Four digit electronic balance 0.0001g resolution (0.1mg), 4-digit Electronic weighing Balance Capacity: 220gx0.1 mg scale, readability 0.1 mg, linearity(+/-) 0.2mg Calibration internal, Accuracy 0.1mg, pan size 90 mm. Warranty 3 years
7EQUIPMENT TO PHYSICS DEPARTMENT
8Searle"s Vibration Magnetometer - Vibration Magnetometer Suitable for comparison of magnetic moments and magnetic fields - Type: Vibration - Size: Customized Backed by rich industry experience, we are affianced in providing a qualitative assortment of Vibration Magnetometer that is suitable for comparison of magnetic moments and magnetic fields.
9optical fiber charecteristics apparatus:to find the numerical aperture, attenuation and bandwidth of optical fibers: laser source, powersupply, adapter , and function generator, two fibers of dfferent legth, LDR detector, optical voltmeter, graduated screen , fiber coupler mounted on translation stage.
10Torsion Pendulum - Steel disk20 cm diameter, with pair ofadjustable chuck nuts, brass wire of 100cm length and 1.5 mm diameter, steel wire 100cm legnth and 1mm diameter, pair of identical mass, and stand with heavy base and length of 90 cms height
11Travelling Microscope - Three axis measurement possibility: horizontal, vertical and right angled transverse motion, coarse and fine movements,resolution of the fine movement: 10 micron, rack and pinion type focusing mechanism,3X long working distance objective and a 10X eyepiece with cross hair,Achromatic Type objective, Base construction : Cast Aluminium,Only high quality makes need to be quoted
12Lamp and scale arrangement (with telescope)- Vertical arrangement, Transformer, for use with 220 volts, Good quality make
13Scale and telescope with stand for both
14Mercury vapour lamp - (1)Lamp house • made of rectangular steel tubes • with proper mounting for cables • bulb and holder • adjustable light output port • with fixed height from the base (2)Transformer (3)Power supply WARRANTY FOR LAMP AND POWER SUPPLY
15Sodium vapor lamp - (1)Lamp house • made of rectangular steel tubes • with proper mounting for cables • bulb and holder • adjustable light output port • with fixed height from the base (2)Transformer (3)Power supply WARRANTY FOR LAMP AND POWER SUPPLY
16Induction heater (for doing heat experiments) High quality full glass panel, upto 2100 W, preset timer and sensor touch
17GM Counter- Radiation counting system with alpha/beta and gamma probes. Should provide alpha,beta and gama sources. Also absorber kit and necessary accessories for carrying out a number of Nuclear Physics experiments such as Characteristics curve of a G.M. Counter, to verify the inverse square law for Gamma Radiation, Absorption of Beta Radiations, efficiency of G.M.Counter for Beta Radiation, determination of the back scattering factor of a material for beta rays etc,. Shouls also provide lead storage container. Specifications G.M. Input (From G.M.Counter)(a) Polarity : Negative (b) Amplitude : 250 mV (min), Resolving Time6 micro sec (approx), HV Output:Variable HV using tenturn pot upto a maximum of 1500 volts at 1 mA. Line and load regulation better than 0.05%. Ripple less than 10mV (rms). Display: 20 x 2 LCD dotmatrix display has been provided to indicate data counts, Elapsed Time and HV. Counts Capacity : 999999 counts Preset time(0-9999) sec., Command Buttons: START, STOP, PROG, STORE, INC & DEC command buttons have been provided on the front panel key pad. Programmability: Includes selection of Preset Time, Storing / Recalling of data, starting and stopping of acquisition etc,. G.M. Socket: MHV connector for connecting to G.M. Detector. Power: Unit is powered works on 230V, AC, 50Hz through power / adapter which delivers +12V input to unit. Mechanical Dimensions: 236mm(W) X 133mm(H) X 246mm(D) Approx.
18Electronic balance - with precision of 0.001gram, diameter of 10-15 cm balance pan, transparent sheild and sliding doors, tare button, level adjust, and display
19Digital outside micrometre- Range 0-25 mm, Resolution 0.001mm, Range 0-1 inch
20Micrometer Screw Gauge (Stainless Steel) - Type: Analog, Measuring Range: 0-25mm, Accuracy: 0.001cm, Only high quality make need to be quoted
21Vernier Callipers - Stainless Steel, Measuring Range: 450 mm,Accuracy: 100%, Display Type: Analog, Only high quality make need to be quoted
22Transistor Characterestics ApparatusFor Common Emitter Configuration- Two regulated DC power supplies, one is 0-1 volt and other is 0-10 volts. 1PNP & NPN transistor with three terminals for base, emitter & collector. Four deluxe quality moving coil type meters, two meters are for measurement of different voltages and other two are for measurement of different currents. 1st meter 0-1V for measurement of base voltage (input) (VB), 2n d meter 0-1/10V (double range) for measurement of collector voltage (output) (VC).3rd meter 0-250µA/25mA (double range)for measurement of base current. (IB). 4th meter 0-25mA for measurement of collector current. (IC). Connecting Chords.
23Ballistic Galvanometer - For low current measurement. Leveling screws for balancing the coil. Coil with mirror suspended between the long suspension at the upper end and a spring at the lower end. Suspension and spring made of special alloy( phosphor -bronze) to provide high degree of sensitivity to the movement. Movement housed in a bakelite case. Resistance 500 Ohm, Time Period - 12 s, Charge Sensitivity - 600mm/µC, Current Sensitivity - 1400mm/µA, Critical Damping Resistance - 3500 O
24Compass box ( 10 cm diameter)
25Permanent bar magnets 7.5cm x 1.5 cmx1cm
26Steel cylindrical die : 14 mm diameter can go upto 100 megapascal
27Digital stop watch
28Jeager"s Apparatus-for measuring the surface tension of a liquid at different temperatures- full set
29EQUIPMENT TO ZOOLOGY DEPARTMENT
30Refrigerator 190 L single door
31Binocculars 42 MM Objective diameter BAK 4 Roof prismWide angle view 6.8 0
3260x60 high -definition dual -tube night vision telescopemonocular
33Smartphone attached Macrolens
34Calorimeter
35Weighing balance (1mg)
36Induction cooktop
37Micropipette 100-1000 variable
38Micropipette 10-100 variable
39Tabletop centrifuge 5kRPM (15 ml tube)
40Micropipette 20-200 variable
41Micropipette 2-20 variable
42Haemoglobinometer
43Haemocytometer
44EQUIPMENT TO BOTANY DEPARTMENT
45-20 Lab deep Freezer 200L
46Spectrophotometer (UV/VIS)Manufacturer should be an - ISO 9001 : 2015Certified Company-Features -Photometric analysis, Quantitative analysis, Spectral scanning, Kinetics, DNA/protein analysis, Multi-wavelength test, etc.-Data Storage – Minimum 150 test data and 50 standard curves;-Wavelength Range 190~1100nm-Spectral Bandwidth 2 nm-Wavelength Accuracy 1nm-Wavelength Repeatability <=0.2 nm-Photometric Accuracy 0.5%T-Photometric Repeatability 0.2%T-Photometric Range 0 - 200%T, - 0.3 - 3A-Stray light 0.15%T-Stability ±0.0002A/h @500nm-Baseline Flatness ±0.002 A-Noise ±0.001 A-Automatic Wavelength Setting -Grating 1200 lines/mm-Light Source -Deuterium & Tungsten lamp-DisplayLCD with backlit -Detector -Silicon Photodiode-Output USB port orParallel port -Printer support is preferable -Power AC 220V/50Hz; AC 110V/60Hz-Approximate Dimension 500*500*250mm-Standard accessories-2 glass cell , 2 Quartz Cell, Software -Weight should be less than 20 kg -Onsite installation -Supplier should have service facility in Kerala
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail