Tender For Certain Br Repair Works In Otm Accommodation Of Ge Complex Bso Yard Mes Mt Area Bldg In Domestic Area At Afs Bhisiana
Tender Overview
Project Description
Tender For Certain Br Repair Works In Otm Accommodation Of Ge Complex Bso Yard Mes Mt Area Bldg In Domestic Area At Afs Bhisiana
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-Oct-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-Nov-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling wall & ceiling board any type, any thickness including cover fillets complete all as specified & directed by Engineer in Charge. |
| 2 | S&F Solid PVC wall panelling consistingof 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified & directed by Engineer in Charge. |
| 3 | S&F 5mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame complete all as specified & directed by Engineer in Charge. |
| 4 | M&L for Non asbestos fibre cement boards 600x600x4mm thick fixed in ceiling Aluminium frame work with screws complete all as specified & directed by Engineer in Charge. |
| 5 | S&F Anodised aluminium snap grid frame work of grid 605x605mm for false ceiling including GI wire 4mm thick for fixing grid complete all as specified & directed by Engineer in Charge. |
| 6 | Taking down Aluminium door/window shutter exc 1 Sqm but not exc 4 sqm each including all accessories, complete all as specified & directed by Engineer in Charge. |
| 7 | S&F Powder coated Anodised aluminium frame for doors, windows, ventilators, partations with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer in Charge. |
| 8 | S&F Powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, mortice locks anodised aluminum snap beading screws etc. complete all as specified and directed by Engineer in Charge. |
| 9 | S & F sheet glass 5.5 mm thick ordinary quality and glazing with oil putty/ any type of beading in square/rectangular exceeding 1.00 Sqm in each pane complete all as specified and directed by Engineer in Charge. |
| 10 | S&F 12mm thick Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work, complete all as specified and directed by Engineer in Charge. |
| 11 | S&F Aluminium (Die Cast body) Door closer hydraulically regulateddesignation No1 universal type suitable for door shutters up to 1000mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed by Engineer in Charge. |
| 12 | Taking down cement plaster on brick orstone masonry Including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed by Engineer in Charge. |
| 13 | Demolition of brick or stone boulder masnory, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facing, dressed stonework and percast concrete articles complete all as specified and directed by Engineer in Charge. |
| 14 | M&L for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean redius, biult in cement mortar (1:6) complete all as specified and directed by Engineer in Charge. |
| 15 | M&L for 15mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and fair (without using extra cement) etc including applying three coats white wash and after preparation of plastered surfaces complete all as specified and directed by Engineer in Charge. |
| 16 | M&L for 15 mm thick Cement plaster in CM (1:4) on fair faces of brick work or concrete surfaces including applying two coat of cement base paint over and a coat of primer after preparation of new plastered surfaces complete all as specified and directed by Engineer in Charge. |
| 17 | Applying a coat of white wash over and after preparation of existing old decorated plastered/unplastered surfaces of walls, pillars, cornices by brooming down etc, complete all as specified and directed by Engineer in Charge. |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer in Charge. |
| 19 | S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of Fe-290 (Gde E165) complete all as specified and directed by Engineer in Charge. |
| 20 | S&F for Rolled mild steel in Rolled sections as in main and cross beams, hip and jack rafters: purlins where connected to common rafters and running rails and guides for sliding doors: fixed with angle cleats or other connecting plate complete all as specified and directed by Engineer in Charge. |
| 21 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer in Charge. |
| 22 | S&F for Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer in Charge. |
| 23 | S&F Plain, Aluminium sheeting,Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing 0.56mm thick complete all as specified and directed by Engineer in Charge. |
| 24 | M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer exposed to view surfaces complete all as specified and directed by Engineer in Charge. |
| 25 | Applying a coat of synthetic enamel paint over old painted steel/iron surfaces of any description having width/girth exceeding 10 cm complete all as specified and directed by Engineer in Charge. |
| 26 | Demolition of cement concrete ground floor and paving nexc 15cm thick (below or above ground level) and dispose with in the MD land 1.5km complete all as specified and directed by Engineer in Charge. |
| 27 | M&L for 50mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate)aggregate as in floor topping of hard standing/floor finished even and smoothwithout using extra cement (PCC shall be laid in alternate bays in panels of sizecomplete all as specified and directed by Engineer in Charge. |
| 28 | M&L for Plastic dividing strips 38 mm width, 1.5mm thick complete all as specified and directed by Engineer-in-charge. |
| 29 | M&L for 50mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection including glass dividing strips on joints, corners etc complete all as specified and directed by Engineer in Charge. |
| 30 | M&L for 75 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base to paving complete all as specified and directed by Engineer in Charge. |
| 31 | M&L forColoured Chequred cement concrete tiles 20cm x 20 cm x 25 mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and directed by Engineer in Charge. |
| 32 | M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS-15658-2006 of60mm thickness M-35 Gradewith grey cement and pigment complete all as specified and directed by Engineer in Charge. |
| 33 | M&L for sand cushning 25mm thick for interlocking tiles complete all as specified and as directed by the Engr-in-Charge. |
| 34 | S&F 100mm wide, 1.5mm thick crack seal self adhesive bitumen flashing tape to prevent leakages and to fill cracks, joints of various surfaces like Asbestos sheet, Metal, Mild steel, Mild steel, galvanised iron/FRP sheet complete all as specified & directed by Engr-in-Chage. |
| 35 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and directed by Engineer in Charge. |
| 36 | M&L for Non skid coloured ceramic tiles/Rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:4) for laying floor finishes complete all as specified and directed by Engineer in Charge. |
| 37 | M&L for Non skid coloured ceramic tiles/Rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick cement plaster in CM 1:3 to receive vertical tiles complete all as specified and directed by Engineer in Charge. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender