| 1 | Earthwork in excavation over areas (exeeding 30cm in depth,1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 2 | Oridinary and Hard Soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 4 | Providing and laying in position cement concrete of specified grade excludingcost of centering and shuttering - All work upto plinth level: |
| 5 | 1:2:4 (1 cement :2 course sand :4 stone aggregate 20mm nominal size) |
| 6 | Providing and laying in position reinforced cement concreteexcluding cost of centering and shuttering , finishing and reinforcement in - |
| 7 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20mm nominal size) |
| 8 | Reinforced cement concrete work in walls including attached pillasters, columns, pillers, posts, piers, abutments, return walls, retaining walls,struts, buttresses, string or lacing courses, fillets etc. upto floor five level excluding cost of centering shuttering etc complete. |
| 9 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20mm nominal size) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement complete. |
| 11 | 1:1.5:3 (1 Cement:1.5 Coarse Sand:3 graded Stone aggregate 20 mm nominal size.) |
| 12 | Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 13 | Providing M-25 grade concrete instead of M-20 grade BMC/ RMC. (Note:- Cement content considered in M-25 is @ 330 kg/cum) |
| 14 | Centering and shuttering including strutting, propping, etc.and removal of form works in - |
| 15 | Foundations, footings, bases of columns etc. for mass concrete. |
| 16 | Walls including attached pillasters, buttresses, string courses, etc. |
| 17 | Columns, pillars, piers, abutments, posts and struts. |
| 18 | Lintels, beams, plinth beams, girders, bressumers and cantilevers, etc. |
| 19 | Suspended floors, roofs, landings, shelves and their support, balconies and chajjaj,etc. |
| 20 | Smooth finishing of exposed surface in R.C.C. work with cement plaster 6mm thick in cement mortar 1:3 (1cement : 3fine sand). |
| 21 | Steel reinforcement for RCC work including straighthening, cutting, bending, placing in position and binding all complete. |
| 22 | Thermo-Mechanically Treated bars of grade Fe-500 or more. |
| 23 | First class brickworkin superstructure above plinth level upto floor V level in: |
| 24 | in cement mortar 1: 6 ( 1 cement : 6 coarse sand ) |
| 25 | Structural steel work rivetted, bolted welded in built up sections, trusses and framed works, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (In Tees, R.S. Joists, Angles, Flats and Channels.) |
| 26 | Supplying and fixing M.S. decorative railing consisting of top and bottom rails of 40mmx40mm square or circular section at distance of 788mm apart, 30mmx30mm square or circular section decorative intermediate balusters welded to top and bottom rails at 280mm apart. The base of balusters at 560mm apart welded with base plate of 60mmx3mm thick and fixed with cement grouting firmly to concrete section including steel priming ans steel painting complete etc. |
| 27 | Providing and fixing M.S. grills of required pattern in frames ofwindows etc. with M.S. flats, square or round bars etc. includingpriming coat with approved steel primer all complete. |
| 28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of 80cm high in staircase, etc consisting of 75mm for rail and post, 63mm for longitudinal intermediate rail and 25mm of vertical section, spacing 125mm interval and as per approval of Engineer-in-charge. |
| 29 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 30 | Dark shade using ordinary cement |
| 31 | Providing Trapezoidal Polyester Coated Galvanised Steel SheetsRoofing of any colour of 1.06m width at all levels including fittingand fixing ridging with self drilling , self tapping screws, EPDMwashers etc. complete excluding the cost of purlin, rafter andtrusses. |
| 32 | For 0.50 mm thick : |
| 33 | Extra for providing and mixing water proofing chemical (latex or equivalent chemical) @ 2kg per bag of cement in - |
| 34 | 20mm cement plaster 1:3 (1 cement :3 sand) |
| 35 | 15mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 36 | 6mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand) |
| 37 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 38 | White washing with lime to give an even shade : New work (three or more coats) |
| 39 | Finishing walls withexterior emulsion of required shade on new work (three or more coats) to give an even shade. |
| 40 | Premium exterior emulsion like weather shield, weathercote etc. |
| 41 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead: |
| 42 | In cement mortar |
| 43 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: |
| 44 | Of area 3 sq. metres and below |
| 45 | Providing 46mm thick single leaf fire door, made of 0.8mm thick galvanized skin pass (GSP) sheet. ? View window : 5x200x300 mm wired glass with framed window. ? In-fill core : Honey comb craft paper bonded with high quality PU adhesive for strength and flatness. ? Frame : 100x58mm sectioned single rebate frame made of 1.2mm thick galvanized skin pass (GSP) sheet. ? Surface finish : Powder coating paint. ? Color shade : Client\"s choice ? Hardaware: 4 SS ball bearing butt hinges, single point locking rim latch panic bar, one surface mounted door closer and 10 anchor screw & fisher sets Ø8mm (including transporation, installation ) |
| 46 | ELECTRICAL |
| 47 | SURFACE STEEL CONDUIT COPPER WIRING ( GRADE-I |
| 48 | LIGHT POINT,CEILING FAN POINT,EXHAUST FAN POINT ETC (MODULAR TYPE) |
| 49 | Wiring for industrial areas in looping system with PVC wire sheathed standard copper conductor/ wires as per IS:694(1990) and Halogen Free Flame Retardant (HFFR) 1100 voltage graded copper flexible wire stranded copper running inside ISI Steel Conduit 20mm dia fixed, surface on the wall/ceiling/floor as per convenience including junction box having required numbers of ways from controlswitch to the light point etc as required:. (For Lift Shaft) |
| 50 | Short Point (modular) |
| 51 | Medium Point (modular) |
| 52 | Supply of LED Bulkhead luminaire, Vandal resistant Polycarbonate diffuser with IP 65, IK08 dust tight and water Jet proof for clean operation with total system wattage 9-10W and system lumen >600 lm, luminaire efficiency of luminaire not less than55 lm/w,( similar to Bajaj CAT No.BIBWP 10W LED/ Philips CAT No. WT202W LED6S CW PSU S2 PC/ TRILUX 9W LED or equivalent as per approved list of make.).( Lift Shaft & terrace) |
| 53 | Supply of indoor type surface mounted Linear LED fitting white CRCA powder coated with total system wattage 18-20W covered by PMMA acrylic diffuser, die cast aluminium housing, high efficiency reflecctor, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED shall be SMD type, fixture should have minimum efficacy >=100 lm/W and minimum system lumens 2000. Similar toBajaj :- BCLAB 20W LED/ PHILIPS-BN108C LED 20S PSU CDL WH LED LUMINAIRE or equivalent as per approved list of make. |
| 54 | POWER PLUG/SOCKET POINT 15/16 AMPERES (MODULAR TYPE |
| 55 | Wiring for industrial areas in looping system with PVC wire sheathed standard copper conductor/ wires as per IS:694(1990) and Life shield- Halogen Free Flame Retardant (HFFR) 1100 voltage graded copper flexible wire stranded copper running inside ISI Steel Conduit pipe 20mm dia. fixed, surface on thewall/ceiling/ floor as per convenience including junction box having required numbers of ways from DB to the power plug/socket 15/16A point etc. as required :- |
| 56 | Short Point (modular) |
| 57 | Medium Point (modular) |
| 58 | MAIN TO SUB-MAIN IN COPPER WIRE GRADE-I SURFACE (SINGLE PHASE TWO WIRES) |
| 59 | Wiring for industrial areas in looping system with PVC wire sheathed standard copper conductor/ wires as per IS:694(1990) and Life shield- Halogen Free Flame Retardant (HFFR)/FR 1100 voltage graded copper flexible wire stranded copper running inside ISI Steel Conduit pipe of all available sizes diameter fixed, surface on the wall/ceiling/floor as per convenience including junction box having required numbers of ways from Main to Sub-Main/DB/Sub-Main/DB to SDB/SDB/Switch boards/SDB to switch boards as required:- |
| 60 | 2X2.5 Sqmm copper conductor/cable + 1x2.5 Sqmm earth wire |
| 61 | 2X 4 Sqmm copper conductor/cable + 1x 4.0 Sqmm earth wire |
| 62 | 2X 10 Sqmm copper conductor/cable + 1 x 10 Sqmm earth wire |
| 63 | MCB DISTRIBUTION BOARD |
| 64 | Supplying,fitting,&fixing of 4-Ways MCB DB single door in sheet steel,Phosphatised powderpainted MCB DBs with Bus Bar, Neutral link,earth bar and din rail conforms to IS:13032, IS:8623, BS:5486 240 Volts 50 Hz, on surface/recess including inter-connection,painting etc, as required. |
| 65 | 12-ways MCB DB SP&N SD metallic door |
| 66 | MCBs/RCCBs/ELCBs/MCCBs/EARTH FAULT RELAY SP/SPN/DP/DP&N/TP/TP&N/FP |
| 67 | MCBs SP/SP&N/DP/TP/TP&N/FP |
| 68 | Supplying and fixing of all types and rating MCBs, RCCBs, ELCBs etc, 240/415 Volts 50 Hz AC supply in the existing MCB DB complete with connections, testing & commissioning etc in completed: |
| 69 | 5 to 32 Amps ,SP, MCB B- series |
| 70 | 40 Amps,DP, MCB B- series |
| 71 | 40 Amps\" DP, RCCB 30mA |
| 72 | LIFT |
| 73 | Supply, Installation, Testing and commissioning of the hydraulic Elevatorincluding Provision for necessary arrangements for like Installation permission & Lift Licensing scaffolding, Mcb, Power Supply, Extension, Pit Buffer Blocks, Pit & Shaft Lighting, brackets, hooks... Etc. refer tender documentPart – 3- DETAILED TECHNICAL SPECIFICATION – ELEVATORS |
| 74 | Compliance to ESMP |