Tender For Work Contract For Aoh Of Boilers- Pressure Parts Of Unit 3 At 2X660 Mw, Sstpp, Mppgcl, Dongalia.
Tender Overview
Project Description
Tender For Work Contract For Aoh Of Boilers- Pressure Parts Of Unit 3 At 2X660 Mw, Sstpp, Mppgcl, Dongalia.--1 Section-A 2 Preparation Of Quick Erect Scaffolding System ( Cup-Lock System ) In Boiler Furnace: 3 Internal Cleaning Of Boiler Ii Nd Pass 4 Cleaning Of Ash From Economizer Hopper, Dead Chamber, Cat House Dog House 5 Preparation Of Scaffolding In Boiler Horizontal Pass ( Screen Tubes, Re-Heater Hanger, Super Heater Hanger Tubes ) 6 Preparation Of Scaffolding Above Economizer Hopper For Inspection Of Economiser Lower Bank Coils. 7 Preparation Of Scaffolding At Ww Ring Header For Inspection Of Ring Header & Refixing / Replacement Of Orifices. 8 Inspection Of Complete Boiler Pressure Parts ( I St & Ii Nd Pass ) 9 Inspection / Repair Of All Peep Holes In Boiler 10 Cleaning And Repair Of All Wind Boxes 11 Servicing Of Secondary / Additional Air Port Dampers 12 Preparation Of Scaffolding In Bottom Ash Hopper And Front / Rear S- Panel Backside, Covering The S- Panel Completely With Sheets For Simultaneous Checking, Repairing Work In Bottom Ash Area And Furnace Togather: 13 Dye Penetrationn Test ( Dpt ) 14 Transportation Of Ash, Scraps, Debris And Other Waste Material ( Incl. Loading. / Unloading ) 15 Thorough Cleaning Of Boiler From Inside By Using Hydro-Jet Cleaning Method. 16 Complete External Cleaning Of The Boiler From Top To Bottom 17 Section-B 18 Rectification, Replacement And Refixing Of Protection Sleeve ( Shielding ) In Various Areas Of Boiler Tubes. 19 Preparation Of Boiler Tube Surface For Tube Thickness Survey 20 ( Section-C ) Welding Of Hp Joints And Alighmentof Boiler Tubes / Coils / Banks 21 Water Wall Tubes ( Primary And Secondary Pass ) / Rifle Tubes, Screen Tubes, Hanger Tubes Etc. 22 Primary Super Heater Tubes 23 Secondary Super Heater Tubes 24 Tertiary Super Heater Tubes 25 Primary Superheater Support / Hanger Tubes 26 Primary Reheater Support / Hanger Tubes 27 Primary And Secondary Reheater Tubes 28 Roof Tubes 29 Economizer Support Tubes 30 Economizer Coils In Reheater And Superheater Pass 31 Alignment Of Coils Oftertiary / Final Superheaters 32 Alignment Of Coils Ofsecondary Superheaters 33 Alignment Of Coils Ofsecondry / Final Reheaters 34 Alignment Of Coil Of Economizer 35 Alignment Of Coil Of Primary Superheater 36 Alignment Of Primary Reheater Coil 37 Welding Of Fins 38 Re-Enforcement Of Welded Joints 39 Checking And Rectification Of Supports / Hangers Of Critical Pipe Lines 40 Checking And Rectification Of Expansion Indicator In Boiler Area 41 ( Section-D ) Application / Repair Of Refractory ( Whytheat C / Whytheat C Patch ) / Bsf Blanket At Various Locations Of Boiler 42 Bottom Ash Hopper Gr-C 43 Pent House, Doors & Windows Etc. ( Additional Air Port / Waterwall Tubes ) Gr.-C / Htc 44 Man Holes, Peep Holes, Roof Seal Boxes Gr-C 45 Hydraulic Test Of Boiler Pressure Part & Preparation For Boiler Light Up 46 ( Section-E ) 47 Complete Servicing / Overhauling Of Hp Valves ( Miv / Mov ) 48 >25 Mm & Upto 50 Mm 49 >50Mm & Upto 100 Mm 50 >100 Mm & Upto200 Mm 51 Above 200 Mm 52 Complete Servicing Of Control Valves ( Excluding Actuator ) . 53 >25 Mm & Upto 50 Mm 54 >50Mm & Upto 100 Mm 55 >100 Mm & Upto200 Mm 56 Above 200 Mm
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Nov-2023 | Third Extension of due date | Date | 28-Nov-2023 |
| 2 | 30-Oct-2023 | First Extension of due date | Date | 08-Nov-2023 |
| 3 | 09-Nov-2023 | Second Extension of due date | Date | 20-Nov-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | SECTION-A |
| 2 | PREPARATION OF QUICK ERECT SCAFFOLDING SYSTEM (CUP-LOCK SYSTEM) IN BOILER FURNACE: |
| 3 | INTERNAL CLEANING OF BOILER II ND PASS |
| 4 | CLEANING OF ASH FROM ECONOMIZER HOPPER, DEAD CHAMBER, CAT HOUSE DOG HOUSE |
| 5 | PREPARATION OF SCAFFOLDING IN BOILER HORIZONTAL PASS (SCREEN TUBES, RE-HEATER HANGER, SUPER HEATER HANGER TUBES) |
| 6 | PREPARATION OF SCAFFOLDING ABOVE ECONOMIZER HOPPER FOR INSPECTION OF ECONOMISER LOWER BANK COILS. |
| 7 | PREPARATION OF SCAFFOLDING AT WW RING HEADER FOR INSPECTION OF RING HEADER & REFIXING/REPLACEMENT OF ORIFICES. |
| 8 | INSPECTION OF COMPLETE BOILER PRESSURE PARTS (I ST & II ND PASS) |
| 9 | INSPECTION/REPAIR OF ALL PEEP HOLES IN BOILER |
| 10 | CLEANING AND REPAIR OF All WIND BOXES |
| 11 | SERVICING OF SECONDARY/ADDITIONAL AIR PORT DAMPERS |
| 12 | PREPARATION OF SCAFFOLDING IN BOTTOM ASH HOPPER AND FRONT/REAR S- PANEL BACKSIDE, COVERING THE S- PANEL COMPLETELY WITH SHEETS FOR SIMULTANEOUS CHECKING, REPAIRING WORK IN BOTTOM ASH AREA AND FURNACE TOGATHER: |
| 13 | DYE PENETRATIONN TEST (DPT) |
| 14 | TRANSPORTATION OF ASH, SCRAPS, DEBRIS AND OTHER WASTE MATERIAL (INCL. LOADING. /UNLOADING) |
| 15 | THOROUGH CLEANING OF BOILER FROM INSIDE BY USING HYDRO-JET CLEANING METHOD. |
| 16 | COMPLETE EXTERNAL CLEANING OF THE BOILER FROM TOP TO BOTTOM |
| 17 | SECTION-B |
| 18 | RECTIFICATION, REPLACEMENT AND REFIXING OF PROTECTION SLEEVE (SHIELDING) IN VARIOUS AREAS OF BOILER TUBES. |
| 19 | PREPARATION OF BOILER TUBE SURFACE FOR TUBE THICKNESS SURVEY |
| 20 | (Section-C) WELDING OF HP JOINTS AND ALIGHMENTOF BOILER TUBES/COILS/BANKS |
| 21 | WATER WALL TUBES (PRIMARY AND SECONDARY PASS)/RIFLE TUBES, SCREEN TUBES, HANGER TUBES ETC. |
| 22 | PRIMARY SUPER HEATER TUBES |
| 23 | SECONDARY SUPER HEATER TUBES |
| 24 | TERTIARY SUPER HEATER TUBES |
| 25 | PRIMARY SUPERHEATER SUPPORT/HANGER TUBES |
| 26 | PRIMARY REHEATER SUPPORT/HANGER TUBES |
| 27 | PRIMARY AND SECONDARY REHEATER TUBES |
| 28 | ROOF TUBES |
| 29 | ECONOMIZER SUPPORT TUBES |
| 30 | ECONOMIZER COILS IN REHEATER AND SUPERHEATER PASS |
| 31 | ALIGNMENT OF COILS OFTERTIARY/FINAL SUPERHEATERS |
| 32 | ALIGNMENT OF COILS OFSECONDARY SUPERHEATERS |
| 33 | ALIGNMENT OF COILS OFSECONDRY/FINAL REHEATERS |
| 34 | ALIGNMENT OF COIL OF ECONOMIZER |
| 35 | ALIGNMENT OF COIL OF PRIMARY SUPERHEATER |
| 36 | ALIGNMENT OF PRIMARY REHEATER COIL |
| 37 | WELDING OF FINS |
| 38 | RE-ENFORCEMENT OF WELDED JOINTS |
| 39 | CHECKING AND RECTIFICATION OF SUPPORTS/HANGERS OF CRITICAL PIPE LINES |
| 40 | CHECKING AND RECTIFICATION OF EXPANSION INDICATOR IN BOILER AREA |
| 41 | (Section-D) APPLICATION/REPAIR OF REFRACTORY (WHYTHEAT C/WHYTHEAT C PATCH) / BSF BLANKET AT VARIOUS LOCATIONS OF BOILER |
| 42 | BOTTOM ASH HOPPER GR-C |
| 43 | PENT HOUSE, DOORS & WINDOWS ETC. (ADDITIONAL AIR PORT/WATERWALL TUBES) GR.-C/HTC |
| 44 | MAN HOLES, PEEP HOLES, ROOF SEAL BOXES GR-C |
| 45 | HYDRAULIC TEST OF BOILER PRESSURE PART & PREPARATION FOR BOILER LIGHT UP |
| 46 | (SECTION-E) |
| 47 | COMPLETE SERVICING/OVERHAULING OF HP VALVES (MIV/MOV) |
| 48 | >25 mm & upto 50 mm |
| 49 | >50mm & upto 100 mm |
| 50 | >100 mm & upto200 mm |
| 51 | Above 200 mm |
| 52 | COMPLETE SERVICING OF CONTROL VALVES (EXCLUDING ACTUATOR). |
| 53 | >25 mm & upto 50 mm |
| 54 | >50mm & upto 100 mm |
| 55 | >100 mm & upto200 mm |
| 56 | Above 200 mm |
| 57 | REPLACEMENT OF VALVES (WELDED TYPE) |
| 58 | Upto 25 mm |
| 59 | >25 mm & upto 50 mm |
| 60 | >50mm & upto 100 mm |
| 61 | (SECTION-F) COMPLETE SERVICING OF SPRING-LOADED SAFETY VALVES |
| 62 | WATER SEPARATOR SV |
| 63 | MAIN STEAM LINES SV |
| 64 | CRH LINES SV |
| 65 | HRHLINES SV |
| 66 | ELECTROMATIC RELIEF VALVE AND PILOT VALVE |
| 67 | (SECTION G) |
| 68 | PREPARATION OF HP TUBE BENDS |
| 69 | REPAIR OF PENT HOUSE/SKIN CASING OF BOILER |
| 70 | REPAIRING OF DEAD CHAMBER |
| 71 | (SECTION H) APPLICATION OF THERMAL INSULATION |
| 72 | COMPLETE BOILER FROM BOTTOM ASH HOPPER TO PENT HOUSE |
| 73 | STEAM AND WATER PIPING |
| 74 | ESP |
| 75 | AIR HEATER & HOPPER |
| 76 | FUEL OIL AND ITS STEAM PIPING INCLUDING HEATERS FILTERS ETC. |
| 77 | (SECTION -I) |
| 78 | SERVICING OF MAIN STEAM STOP VALVE |
| 79 | SECTION-J |
| 80 | COMPLETE OVERHAULING & RESETTING OF WATER WALL SOOT BLOWER: - |
| 81 | COMPLETE OVERHAULING & RESETTING OF LONG RETRACTABLE SOOT BLOWER: - |
| 82 | (SECTION -K) INSTALLATION AND MAINTENANCE OF CCTV CAMERA TO DIFFERENT LOCATIONS OF BOILER |
| 83 | work of installation and implementation of CCTV surveillance system during AOH |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender