}

Tender For Development Of Integrated Traffic Management System To Enhance Logistic Efficiency For Ghojadanga-Sangrampur Road (At 1.60 Km Of The Road Stretch Ghojadanga Border) For The Commercial Vehicles Under Barasat Highway Division No. I In The Stat, kolkata-West Bengal

Public Works Department-PWD has published Tender For Development Of Integrated Traffic Management System To Enhance Logistic Efficiency For Ghojadanga-Sangrampur Road (At 1.60 Km Of The Road Stretch Ghojadanga Border) For The Commercial Vehicles Under Barasat Highway Division No. I In The Stat. Submission Date for this Tender is 17-11-2023. Traffic monitoring system Tenders in kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

40020369
Corrigendum : Tender For Development Of Integrated Traffic Management System To Enhance Logistic Efficiency For Ghojadanga-Sangrampur Road (At 1.60 Km Of The Road Stretch Ghojadanga Border) For The Commercial Vehicles Under Barasat Highway Division No. I In The Stat
Open Tender
Indian
West Bengal
kolkata
17-11-2023

Tender Details

Development Of Integrated Traffic Management System To Enhance Logistic Efficiency For Ghojadanga-Sangrampur Road ( At 1.60 Km Of The Road Stretch Ghojadanga Border ) For The Commercial Vehicles Under Barasat Highway Division No. I In The State Of Wes

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Nov-2023 1st corrigendum Date 17-11-2023

Key Value

Document Fees
Refer document
EMD
INR 361644.0 /-
Tender Value
INR 1.80 Crore /-

BOQ Items

Name of Work: Development of Integrated Traffic Management system to enhance logistic efficiency for Ghojadanga-Sangrampur Road(at 1.60 Km of the road stretch Ghojadanga Border) for the Commercial Vehicles under Barasat Highway Division No. I in the State of West Bengal during the year 2022-23.(4th Call)
Sl. No. Item Description
1ROAD WORK
2Dismantling of Cement Concrete Pavements Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202 for Rural Roads of MORD.
3Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specifications Clause 202 for Rural Roads of MORD. By Manual Means Reinforced Cement Concrete
4Dismantling Kerb Stones Dismantling kerb stones by manual means and disposal of dismantled material with all lifts and upto a lead of 1000 m as per Technical Specification Clause 202 for Rural Roads of MORD.
5Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
6Supplying, spreading and compacting Sand (Yellow, medium) to required thickness, in layers not exceeding 150 mm to proper gradient and camber, inundating each layer by water and packing and ramming layer by layer to achieve desired compaction, including lighting, guarding, barricading and making adequate earthen bundh where necessary, curing with water as per direction, mending cracks and depressions by ramming wherever necessary.
7Supplying, spreading and consolidating Stone Dust to a depth of 100 mm and above at desired density and C.B.R. as per Specification with power roller to proper gradient and camber including watering as necessary, and lighting, guarding, barricading and making adequate earthen bundh where necessary to protect the edges and curing with water for 2 to 3 days, mending cracks and depressions by rolling where necessary including all incidental charges of roller, cost of fuel & lubricants complete as per specification. (Compaction factor = 0.70)
8Granular Sub-base with Graded Material (Table:- 400-1) A. Plant Mix Method: Construction of granular sub-base by providing graded material (Pakur Variety), mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). Grading – II
9Granular Sub-base with Graded Material (Table:- 400-1) A. Plant Mix Method: Construction of granular sub-base by providing graded material (Pakur Variety), mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). Grading – III
10Wet Mix Macadam Base Course Providing, laying, spreading and compacting graded stone aggregate (Pakur Variety) to Wet Mix Macadam specification including screening of aggregates and granular materials, premixing the material with water at OMC in Wet Mix Plant, carriage of mixed material by tipper to site, laying in uniform layers with Paver in Sub- base / Base course on well prepared surface and compacting with Vibratory Roller to achieve the desired density, including supply of all materials, machinery, fuel and lubricants, including incidental costs for lighting, guarding, barricading, making earthen bundh to protect the edges including cost of quality control complete as per Clause 406 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
11Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate (Pakur Variety) not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing. (As per clause 601 of specifications for Road & Bridge Works of MoRT&H (5th Revision).
12Cement Concrete Pavement (laying manually) Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with cement content as per IRC: 15-2011, coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate (Pakur Variety) not exceeding 25 mm, mixed in a batch mix plant / RMC and appropriate weigh batcher using approved mix design (as per IRC:44 2008), laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing, spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, polysulphide sealant, dowel bars, near approaches to bridge/ culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501 for Rural Roads of MORD. With RMC
13Plain / Reinforced Cement Concrete in Open foundation with or without reinforcements, in any part of foundation of bridges / culverts with graded stone chips of appropriate nominal sizes, including screening and cleaning of coarse aggregates, fine aggregate (sand) conforming to proper grading zone, both of approved quality and cement, as necessary, cost of curing with water, including cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge, cost for quality control, sampling, testing etc. including cost of formwork but excluding reinforcement complete as per drawing and technical specifications.RCC Grade M25 With Batching Plant,Transit Mixer and Concrete Pump
14Supplying, fitting and placing HYSD bar reinforcement in Sub-structure including initial straightening, straightening of coils bars, removal of loose rust (if any), cutting to requisite length bending, binding with annealed wire not less than 1 mm in size and conforming to IS 280 at every intersection hooked and bent to correct shape and placed on forms etc. including cost of black annealed wire and cost of loading, unloading, carriage of all steel materials complete as per drawing and technical specifications and direction of Engineer-in-charge. TATA/SAIL/RINL
15Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-inCharge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
16Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. In Ground Floor Two Coats
17Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer. In Ground floor (Two Coat) Super Protective100% Acrylic Emulsion
18TRAFFIC SAFETY
19Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). 90 cm equilateral triangle
20Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). 80 cm x 60 cm rectangular
21Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). 60 cm circular
22Direction and Place Identification Signs with size more than 0.9 sqm size Board. Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision)
23Direction and Place Identification Signs upto 0.9 sqm Size Board. Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision)..
24Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes complete as per Clause 803 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
25B Type - B, "THRIE" : Metal Beam Crash Barrier Providing and erecting a "Thrie" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2 m high with 1.15 m below ground level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a space of channel section 150 x 75 x 5 mm, 546 mm long complete as per Clause 811.3 of Specifications for Road & Bridge Works of MoRT&H (5th Revision
26Supplying & fixing of Raised Pavement Markers / Road Studs / Cats Eye made of polycarbonate moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face which shall support a load of 13635 kg tested in accordance to ASTM D 4280 Type H and complying to clause no 804 of MoRT&H"s specification for Road &Bridge Works (Fifth Rev.). Marker height shall not be less than 10 mm and shall not exceed 20 mm, width shall not exceed 130mm and with minimum reflective area of 13 sq.cm. on each side and slope to the base shall be 35 ± 5 degree. Fixing will be without nails but by using epoxy resin based adhesive as per manufacturer"s recommendation including site clearance etc. and complete as directed by the Engineer in Charge .The contractor will have to provide a test certificate from a reputable national/international laboratory conforming the above specifications.
27Road Delineators Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and conforming to IRC-79 and the drawings
28RUF- BOOTH & OFFICE BUILDING
29Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
30Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity).Do - by fine sand
31Cement concrete with graded stone ballast (40 mm size excluding shuttering)In ground floor [Pakur Variety] 1:3:6 proportion
32Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
33Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
34125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
35Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar 20 mm thick plaster
36Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar, 15 mm thick plaster
37Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar, 10 mm thick plaster
38Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety
39Ordinary Cement concrete (mix 1:2:4) with graded Stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety
4025mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer"s specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).[Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).
41Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement. 25 mm. thick
42Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of Concrete, Iron Butt Hinges and M.S clamps. (The quantum shouldbe correted upto three decimals). Sal : Local. For Office and Server room.
43Supplying solid flush type doors of deluxe decorative (both side) quality,conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid coreand internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: 35mm thick shutters (single leaf)
44Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria..(i) 66mm x 90mm
45Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor. (i) 32 mm thick
46Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m.
47Supplying, fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white window ( two track)
48M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
49Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer"s specification) including cleaning and smoothning of surface. Two Coats
50Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. In Ground Floor: One Coat
51Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer. In Ground floor (Two Coat) a) Normal Acrylic Emulsion
52Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:(v) 100 x 63 x 3.2mm.
53Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal/ Round rod)(ii) 100 mm grip x 10 mm dia rod.
54Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete(iii) 300mm x 16mm dia. bolt.
55Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc.(a) With "P" trap (with vent)
56Supplying,fitting and fixing cast iron "P" or "S" trap conformimg to I.S. 3989/ 2009 and 1729/ 2002 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately). (A) "P" Trap 100 mm
57Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
58Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer(b) 1000 litre capacity
59Labour for punching hole in plastic water storage tank upto 50 mm dia.
60Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes 40 mm (Dia)from water tank to bath
61For Concealed Work 20 mm (Dia)
6215 mm (Dia)
63Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). 40 mm dia
6420 mm dia
65Supplying, fitting and fixing bib cock or stop cock. (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511& Model - Tropical / Sumthing Special of ESSCO or similar brand).
66Chromium plated Stop Cock (Equivalent to Code No. 513(A) &513(B) & Model - Tropical / Sumthing Special of ESSCO or similar
67Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (i) 450 mm X 300 mm size
68Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length, (b) 110 mm
69Fittings Door Bend (T.S.) (b) 110 mm
70Vent Cowl (b) 110 mm
71Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A) Above ground, (ii) 110 mm dia.
72Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (JSW/JSPL/ SHYAM/ RINL Etc..)
73Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. (ii) For 20 users i) With Pakur variety. (JSW/JSPL/ SHYAM/ RINL Etc..)
74Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. i) With Pakur variety. (JSW/JSPL/ SHYAM/ RINL Etc..)
75Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety
76Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
77Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel/Mild Steel I. SAIL/ TATA/RINLconsidered 1.50% for base
78M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.III) For built up sections / srtuctural members of specified sections weighing not less than 22.5 Kg./m
79Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed.ii) 20 mm dia bolt.,600 mm long
80M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete.i) For roof truss works a) Span up to 12 Mtr
81Supplying, fitting & fixing Industrial Troughed Aluminium sheet (excluding the supporting frame work) of approved make & brand in alloy 3105 conforming to IS: 1254-1991 fitted and fixed with 75 mm & 25 mm Self tapping screw , EPDM Washer 16 mm dia & 3 mm th washer etc complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work) (Aluminium sheet to be supplied by contractor).(i) In Roof:- a) With 0.65 mm thick sheet
82Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge. (Excluding cost of glass/ panel board,10-12 Micron thickness Annodizing film. Natural white.b) For unsupported length of vertical member above 1.50m. height of both ends of vertical member restrained but panel above 0.90 sqm
83Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white
84Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. xiii) 12 mm thick cleared toughened glass coforming to IS: 2553-1992 (Part-II)
854mm thick cleared glass.
86Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP)(a) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating)
87Supplying "Godrej" mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete.
88Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5.a) 25 mm thick Tiles as per IS: 1237-2012 for footpath,ramp,staircase of public building(over 25 mm thick (Avg) Cement mortar (1:3) & Cement Slurry @ 4.4 kg/Sq.m at back side of Block. Cement for Mortar & Slurry to be supplied by Department).(ii) Coloured Decorative
89Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor.
90Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
91Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
92TUBEWELL
93Labour for boring tubewell of required dia by water jet system through any type of soil, strata including hire and labour charges for boring pipes, scaffolding, other tools and plants as necessary and taking outthem and lowering pipes and strainers, blank pipe etc. and fitting,fixing the same complete including bucket washing and other incidental works in this connection. (The tubewellshould have a minimum 50mm. gap in between the outside ofthe tubewell pipe and the bore). For depth upto 150mtr. for 50mm dia tubewell with top enlargement of 100mm dia.
9450mm dia.
95For depth more than 150mtr. for 50mm dia tubewellwith top enlargement of 100mm dia. 50 mm Dia
96Supply of PVC pipes & fittings, Schedule - 80 (Medium Duty) conforming to ASTM-D 7785, and threaded to match with GI Pipes as per IS 1239 (Pt-1) i) 40mm dia.( Column pipe.)
97ii) 50mm dia.pipe. Blank pipe-3.65m Main pipe-35X6=210.00m
98100mm dia.pipe. Housing pipe-7X5.00=35.00m
99Supply of High density polythene strainer of approved make with adopter conforming to IS Specification 50mm dia.
100Supplying fitting & fixing 100 x 50 mm P.V.C. Reducing Socket (Med)
101Supplying fitting & fixingP.V.C.Nipple (150mm long),100mm dia.
102Supplying fitting & fixingP.V.C.Threaded Adopter .40mm dia.
103Supplying fitting & fixing steel cutter piece upto 450 mm long with socket.
104Supplying fitting & fixing 40 mm dia. Plug of approved make conformins to IS Specifications.
105Supplying fitting & fixing G.I cap at top. (I) 100mm
106Supply ofG.I short piece of TATA ( Above 50mm & 150mm long) 40mm
107Supply ofG.I plain tee of approved brand and make 40mm
108Supplying of G.I reducing soket with I.SI mark 32mm
109Labour for fitting and fixing G.I specials including cost of jointing materialss. Socket,Reducing socket,bend ,plain equal elbow,reducing elbow,Nipple,Short piece. Above 25mm upto 50mm dia. Plain tee,reducing tee, pendent tee, Jamnut,Socket and Nipple
110Above 25mm upto 50mm dia.
111Supplying solvent cement
112Supplying,fitting and fixing 300mm M.S housing clamp of approved quality.
113Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
114Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with "V" notch including hire and labour charges for all tools and plants and scaffolding as required.
115ELECTRICAL WORKS
116Supplying and fixing 415V, 63A, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [Make - Legrand/ Schneider/ Siemens /ABB/L&T)
117Supplying and fixing 415V, 63A, TPN onload change over switch with sheet steel enclosure on angle iron frame on wall with nuts bolts etc. [Make - Legrand/ Schneider/Siemens /ABB/L&T)
118Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make - Legrand/ Schneider/ Siemens / ABB/ L&T) 6 Way Enclosure (upto 160A) [15/D-11]
119Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make - Legrand/ Schneider/ Siemens / ABB/ L&T) 2+4 Way [13/D-9]
120Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. [Make-Legrand/ Schneider/Siemens /ABB/L&T) (a) 63A FP
121Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ] 32 A DP [ 6 / D- 5 ]
122Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens /ABB/L&T) as per direction of EIC. ] 6-32 SP [ 7 / D- 6]
12332 TP [ 7 / D- 6]
124Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit "FR" (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. (i) Average run upto 5 mtr. [1(a)/E-24]
125Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit "FR" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. On Board [ 3(a) / E- 24 ]
126Average run 3 mtr[ 3(c ) / E- 24 ]
127Distribution wiring in 1.1 KV single core stranded "FR"PVC insulated & unsheathed copper wire (Brandapproved by EIC) in 20mm size PVC rigid conduit "FR"(Precision make) incl. necy. fittings as required. [1(a)/E-14] (a) 2 x 36/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC.
128(b) 2x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC (for office room SPNDB incomer)
129(a) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (For midbay LED Light circuit wiring & computer Board)
130S & F solderless Copper socket by crimping of Copper wires. a)1.5 sq mm [N.S]
131b) 2.5 sq mm [9(i) / F-5]
132c) 4 sq mm[9(ii) / F-5]
133d) 6 sq mm[9(iii) / F-5]
134Supply & Delivery of2/4Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make - Gloster / RR/ KEI/Havells as approved by E.I.C] 4 Core 10 Sqmm[N.S.]
1352 Core 6 Sqmm[N.S.]
1364 Core 16 Sqmm[N.S.]
137Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
138Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 Core 10 Sq. mm [7(c)/F4 ]
1392 Core 6 Sq. mm [7(a)/F4 ]
1404 Core 16 Sq. mm [7(d)/F4 ]
141Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. 4 Core 10 Sq. mm [8(b)(xi)/F-5 ]
1422 Core 6 Sq. mm [8(b)(ii)/F-5 ]
1434 Core 16 Sq. mm [7(d)/F4 ]
144Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [12/E-18]
145Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C- Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
146Supplying & Fixing GI Modular Switch Boardcomplete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works including Supply & Fixing 240 V, 16 A,Modular typeswitch (approved make) on existing GI Modular switchboard having top cover plate and making necessary connections as required.
147Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
148Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
149Supply & Delivery of 4 feet Industrial boxtype Twin LED fitting including S & D of 2X20 wattt LED (Polycarbonate) with glare free light distribution , with minimum luminious efficacy 100 lumen/wt. (Mk. : Crompton/ Wipro/ Jaquar/ Bajaj/ Havells/ Panasonic)
150Supply & Delivery of 4 feet Industrial boxtype Single LED fitting including S &D of 1X20 wattt LED( Polycarbonate) with glare free light distribution , with minimum luminious efficacy 100 lumen/wt. (Mk. :Crompton/ Wipro/ Jaquar/ Bajaj/ Havells/ Panasonic)
151Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener. [14(b)/C-2]
152Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) [29/D-14]
153Supply& Delivery ofceiling fans with burst-proof P2/S3 Capacitorcomplete with all accessories without regulator.(Make - Usha/Havells/CG/Orient/Crompton) 1200 mmSweep
154Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
155Engraving the deptt. number with 10 mm lettering on the body as per GS.[ 24 (a) / C-3 ]
156Extra for additional one letter incl. hifen, stroke and stop.[24(b)/C-3]
157Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS[ 26 (a)/C-3]
158Extra painting for additional one letter of the engraved number with hifen, stroke etc. with black or red paint. [26(b)/C-3]
159Supply and fixing of 240V, 9" (230 mm) dia,1370 rpm AC exhaust fan (EPC Make)after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of given diameter. [Make-EPC/ Crompton/ Orient/ Usha]
160Supply and fixing of 240V, 12" (300 mm) dia, high speed full metal body, metall blade, wall bracket/ Cabin fan on wall incl. necessary fixing materials and mending good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire. [Make -EPC/Crompton/Orient/Usha/Cinni]
161Supplying & fixing medium gauge HDPE Pipe (ISI-Medium) with fittings like bend, tee and cast iron inspection boxfor underground cable Protection as per GS ( Make : Oriplast / Finolex/ Supreme/ AKG) 50 mm dia [11(d)/F-6]
162Fixing only outdoor / street light type fluorescent/LED light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one endand thread at the other end & suitable bend to house the fitting &making necy. connections with S&F necy. length of 1.5 sqmmPVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting.
163Supply & fixing of minimum 30 Watt or higher (Minimum lumen efficacy :110 Lumen/Watt)Street Lightwith fittings & fixures as per direction of EIC. (Make : Crompton/Wipro/Bajaj/ Havells) for street light.
164Supply & fixing of minimum 500 Watt or higher (Minimum lumen efficacy : 120 Lumen/Watt)Street Light (IP 66) (Detail specification as per Annexure-I attached) with fittings & fixures as per direction of EIC.(Make : Crompton/Wipro/Bajaj/ Havells ) for street light.
165Supply & fixing of minimum 150 Watt or higher (Minimum lumen efficacy :120 Lumen/Watt)Midbay Outdoor Lightwith fittings & fixures (Make : Crompton/ Wipro/ Bajaj/ Havells ) for Overhead light at Kiosk hanging from Struss with necessary arrangement as per direction of EIC.
166S&F of 230V timer DB ( with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 25A DPMCB (C-curve 10ka), 32A DP Power Contactor and 1 no 24 hr. digital time switchwith internal wiring with suitable size of copper wire including 1 no. toggle switch and LED indicator and earthing attachment as per direction of EIC. (Mk. - L&T/ Siemen/ABB/Legrand)
167Supplying & Fixing GI waterproof type looping cable box size 200 x 150 x 100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. [5/H-5]
168Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level[By TATA-Medium GI pipe] [2(a)/G-1].
169Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
170Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
171Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS No.-4 SWG [5(a)(i)/G-2]
172No.-10 SWG [5(a)(iv)/G-2]
173SITC of Traffic signal light ( Red / Green / Yellow ) with controller & interconnectioin.
174SITC OF DG Set "SITCof 15 KVA, 415V, 50Hz, 3Ø silent new DG Set incl. full tank HSD oil,comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-II approved Engine & Acoustic Enclosure having following specifications :- (Conformance Standard : IS 8528, IS 4722) "Engine:- Make : CUMMINS/ Kirloskar/ Ashok leyland/ Greaves Cotton/ Mahindra. Engine Type :4 Stroke Diesel Engine RPM :1500 MoEF certified power :20.5 BHP or Higher Duty : PRIME Cooling:Water cooled with radiator Cylinder : 2 or more Aspiration:Turbo Charged Type of Governor :Electronic Fuel Tank Capacity : Minimum capacity 50 Ltrs. or Higher FuelConsumption at 75% rated Load with Radiator or Fan : 3.0 Ltr./ Hr. or Less. Fuel Consumption at 100% rated Load with Radiator or Fan :4.3 Ltr./ Hr. or Less. Overload Capacity:10% overload for one hour for every 12 hours continuous running at full load or better. Engine instrument Panel : Consisting of starting switch with Key, Lube OilIndicator, water temperature Indicator, RPM indicator and hour meter.
175Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine over speed indicator,Battery charging and low battery indicator. Exhaust Silencer: Residential Type Starting system:12V/ 24 V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard. Battery:Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning. Alternator :- Make : Stamford/ Leroy Some/kirloskar/ABB/Crompton Rating: 415 V, 3Ph. 50 Hz., 15 KVA, 1500 rpm Type : Brushless, self excited and self regulated Insulation:Class H Protection : screen-protected drip proof with Min.IP-23 degree of protection RPM: 1500 Voltage Regulation (max) : ±1% Winding connection : Star with Neutral Total distortion in output waveform : < 5% AMF Panel ( CPRI APPROVED) :- Cubical type floor mounted AMF panel made from 14 SWG Sheet Steel,duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 15 KVA DG set having following specification/features. i) 2 Nos. 63 A AC1 duty, 4 Pole power contactorandU/V release etc. [Make: ABB/ Legrand/ Siemens/ Schneider/L&T]
176ii) 2 Nos. 63 A, 4 Pole, 25 KA MCCB with microprosser based LSIG protection. [Make:ABB/ L&T/Siemens/Legrand/ Schneider] iii) In Built By-Pass switch for rated capacity iv) On -delay timer for load change over v) Off-delay timer for engine shut off vi) Engine On-Off switch (Push button type) vii) Battery charger complete with voltage regulator, booster selector switch, on-off switch, voltmeter and ammeter for charging the battery from mains. This will be in addition to the battery charging alternator fitted on the engine. viii) Minimum five number indicating lamps to indicate "mains ON", "load on mains", Set running", "load on set" and "battery charger on". ix) Audio visual alarm for "Low lubricating oil pressure", "High water temperature, Start failure", and DG over load". ix) Mode selector for setting the panel on Auto/ Man/ Test Mode. x) Microprocessor based relay with composite meter for digital display of following. Generator voltage/AC Mains voltage. Generator Current in all phases Frequency Power Factor Energy Indication for alternator supply.
177Running time indications number of hours of operation and service intervals, service due indications. The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure. Acoustic Enclosure :- The DG set should have integrated acoustic enclosure at the manufacturing state itself.High quality acoustic enclosure must be certified as per CPCB-II norms. Base Frame :- Common iron channel fabricated base frame containing the engine and alternator, mounted onAVM pads and having provision for lifting Hook. Terms & Conditions :- (i) All materials, equipments & accessories must conform to relevant IS specifications. The DG Set to be supplied must be from the authorizedOEM of the respective Engine Manufacturer. (ii)Necessary manufacturer"s test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment. (iii) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competent Authority (As per CPCB-II). (iv) Circuit Diagram for AMF Panel must be submitted from the Manufacturer/ OEM.
178SITC of 30 mtr. over all length Polygonal segmented High Mast GI polewith luminaries carriage fixed on re-inforcement steel cement concrete foundation with anchoring "J" bolts with nuts as per attached specification, vide Annexure -I. (Make -Transrail/ Bajaj/ Philips-Signify/ Crompton/ Wipro).
179GST @ 18% over Sl. No. 1.00 to 4.17
180Labour Welfare Cess @ 1% over Sl. No. 1.00 to 5.00
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail