Tender For Construction Of Common Facilitation Centre At Zakura Srinagar
Tender Value
29.48 Lakhs
Estimated cost
Bid Submission
11 Oct 2023
0 days left
EMD
58960
Bank guarantee accepted
Document Fee
1100
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
zakura → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Common Facilitation Centre At Zakura Srinagar
BOQ
| Sl. No. | Item Description |
| 1 | Clearance of site by way of Surface dressing incl removal of vegetations uprooting of trees etc incl disposal of sames beyond municipal limits complete job. |
| 2 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres in All kinds of soil : |
| 3 | P/L stone soling(Hand packed) in trenches incl. ramming, dressing ,watering etc.incl. all leads, lifts and carriage upto site of work complete. |
| 4 | Providing and laying in position specified grade of cement concrete excluding the cost of centering and shuttering - All work at all levels in : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) including cost and carriage of all materials involved upto site of work complete. |
| 5 | Providing and laying in position specified grade of reinforced cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) Incl Cost and carriage of material upto site of work complete. |
| 6 | Providing and laying in position reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) Incl Cost and carriage of material upto site of work complete. |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Incl Cost and carriage of material upto site of work complete. |
| 8 | Steel reinforcement of Thermo-Mechanically Treated bars of grade Fe-500D or more for R.C.C. work includingstraightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 9 | Brick masonry with FPS bricks of class designation 75 in super structure upto floor V level in cement mortar 1:6 (1cement:6cement coarse sand) comp-lete inculding cost & carriage of all materials involved upto site of work complete. |
| 10 | 15mm Cement plaster on the rough side of single or half brick wall of mix:1 : 4 ( 1 cement : 4 fine sand) Incl Cost and carriage of material upto site of work complete. |
| 11 | Providing Imported /budloo wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) |
| 12 | Providing and fixing 35 mm thick Second class Kail wood glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 13 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.50mm thickinculding cost & carriage of all materials involved upto site of work complete |
| 14 | Providing and fixing of 50mm thick glass pans in joints of flooring completeinculding cost & carriage of all materials involved upto site of work complete as per direction of Engineer -IN-charge. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 16 | Foundations, footings, bases of columns etc. for mass concrete |
| 17 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 18 | Suspended floors, roofs, landings, balconies and access platforms. |
| 19 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 20 | Structural steel work in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 21 | Providing & fixing precoated galvalume profile sheets 0.50mm TCT having a crest height of 28-32mm at 195mm pitch and effective width of 975-1000mm and length to suit site requirement to the purlins using self drilling and self tapping fasteners of reputed make with purlin sheet using self drilling and self tapping fasteners & fixingFlashings, Valleys and ridges of colour coated galvalume plain sheets using self drilling and self tapping fasteners of reputed make complete and as directed. The contractor shall give a minimum of 10years guarantee for sheets against deterioration, disintegration loss of luster, variation in colour, etc and leakage across laps, fasteners etc. all types of steel sheets shall be load tested to satisfy 1:10 times the design wind load and coating thickness to the satisfaction of EIC. Fasteners shall also be load tested. the contractor is to submit desgin and shop drawing for approval on the sheet profile, design and fabrication details before installation (including cost of all material, leads lifts and carriages etc upto site of work complete) (High Rib Colour coated) |
| 22 | P/F of colour coatedridges or hips of width 60cm width of G.S sheet fixed with polymer fixed with polymer coated j or l hooks bolts & nuts 8mm dia (0.50mm thick all cost carriages complete. |
| 23 | Dry random rubble masonry with hard stone in foundation and plinth incl. Carriage and cost of material upto site of work complete. |
| 24 | Providing and applying 2 mm thick white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 25 | Applying priming coats With water thinnable cement primer on wall surface having VOC (Volatile Organic Compound)content less than 50 grams/liter of approved brand and manufacture |
| 26 | Wall painting with two coats ofacrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 27 | Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 28 | Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture of required shade and colour to give smooth finish with two or more coats on new wood and based surfaces |
| 30 | Providing and fixing of glass panes using 4mm thick glass incld cost of beeding nails etc.As per directions of Engineer-incharge at site complete |
| 31 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 32 | Providing and fixing W.C. pan with ISI marked white solid plastic seat and lid. white vitreous china pedestal type water closet (Indian type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required |
| 33 | Providing and fixing W.C. pan with ISI marked white solid plastic seat and lid. white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required |
| 34 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. |
| 35 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 36 | P/Fixing of PPR fittings of approved quality |
| 37 | Pipe 32mm dia |
| 38 | Pipe 25mm dia |
| 39 | Union32mm dia |
| 40 | Union 25mm dia |
| 41 | Gate valve 32mm dia |
| 42 | Gate valve 25mm dia |
| 43 | Providing and Fixing PVC Fittings of approved make |
| 44 | PVC Pipe 100mm dia |
| 45 | PVC Pipe 75mm dia |
| 46 | Plain bend 100mm dia |
| 47 | Plain bend 75mm dia |
| 48 | Door bend 100mm dia |
| 49 | D/Junct 75mm dia |
| 50 | F/Trap 100mm dia |
| 51 | Providing and Fixing CP Fittings of approved make |
| 52 | Angle valve |
| 53 | 15mm bib cock |
| 54 | Health faucet with shower |
| 55 | CP Grating |
| 56 | CP Soap case |
| 57 | CP Wall mixer |
| 58 | CP Basin mixer |
| 59 | Providing , installation, commissioning and testing Hot water Geyser of approved make including fixing with bolts and making necessary connections.Sample to be approved by the Engineer-in-Charge.50 litre capacity |
| 60 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per directions of Engineer incharge at site complete. |
| 61 | Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:6 (1 cement : 4 coarse sand),200mm thick foundation concrete 1:4:8 mix (1 cement : 4 coarse sand; 8 graded stone aggregate 40mm nominal size), inside and outside plastering 12mm thick with cement mortar 1:3 (1 cement:3 coarsesand), finished with a floating coat of neat cement inside and rough plaster on outside and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size), neatly finished complete as per standard design including excavation, refilling and disposal of surplus earth. incl. cost of C.I. manhole cover with frame. |
| 62 | 12\"x12\" |
| 63 | 18\"x18\" |
| 64 | Electric Fitting |
| 65 | Point wiring for switch controlled primary light points with 3x1.5 sq mm (P+N+E) FRLS PVC insulated flexible stranded copper conductor wires of Polycab /Havells / Finolex /Anchor make in recessed or surface conduitng system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch of Anti fungal & Anti Bacterial of Schneider /ABB /L&T /Honeywell make and colour housed in zinc chromate passivity GI boxes with modular cover plate complete as per specification and as required . (Excluding cost of conduits.) |
| 66 | Point wiring for ceiling fan points with 3×1.5 sq mm (P+N+E) FRLS PVC insulated flexible stranded (50 strands of 0.25 mm dia.) copper conductor wires of Polycab /Havells / Finolex /Anchor make in recessed or surface conducting system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch and 240 volts 300 watt 5 step electronic speed regulator of Anti fungal & Anti Bacterial of Schneider /ABB /L&T /Honeywell make and colour housed in zinc chromate passivity GI boxes with modular cover plate and with inter connections complete as per specification and as required. (Excluding cost of conduits.) |
| 67 | Point wiring for 10 Amp Socket out lets with 2 ×2.5 sq mm (P+N+E) FRLS PVC insulated flexible stranded copper conductor wires of Polycab /Havells / Finolex /Anchor make in recessed or surface conducting system incl the cost of supplying and fixing modular grid plate mounted flush mounted 2 no 240 volts 6 amp 5 pin socket out let along with 2 No\"s of 6 Amp control Switch of of Anti fungal & Anti Bacterial of Schneider /ABB /L&T /Honeywell make and colour housed in zinc chromate passivity Gl boxes with modular cover plate and inter connections and including cost of loop Earthing with 2.5 sq mm FRLS PVC Insulated circuit wiring( from DB to first switch in the sub circuit) complete as per specification and as required volt grade flexible stranded copper conductor wires complete as per specifications and as required ,complete job excluding pvc conduitng Complete as required The Job includes providing and laying of circuit wiring of same size from DB to first switch in sub circuit upto 8 Mtrs in length (Maximum two points shall be connected / provided in one circuit ) Complete as required (Excluding cost of PVC conduits) |
| 68 | Point wiring for 16 Amp Socket out lets ( Two out lets wired in one sub circuit ) with 3x4 sq mm (P+N+E) FRLS PVC insulated flexible stranded copper conductor wires of Polycab /Havells / Finolex /Anchor make in recessed or surface conducting system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 16 amp 6 pin combined shuttered socket out let along with 240 volt 16 Amp control Switch of of Anti fungal & Anti Bacterial of Schneider /ABB/L&T /Honeywell make and colour housed in zinc chromate passivity Gl boxes with inter connection complete as per specifications and as required. The Job includes providing and laying of circuit wiring of same size from DB to first switch in sub circuit upto 8 Mtrs in length (Maximum two points shall be connected / provided in one circuit ) Complete as required (Excluding cost of PVC conduits) |
| 69 | Supply, Installation, Testing and commissioning of 12 watt LED surface mounted Down lighters having Aluminium Body ,minimum lumens 100 Im/w,the luminaries housing should be aluminium and the luminary optics shall have a high efficiency with transmittance average life of 50000 hrs operating temperature -10 C to + 45 C of Phillips/Bajaj/Trile×/WIPRO/Jaguar make incl making of necessary Connections.. The job further includes replacement warranty of fixture (if damaged /burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. The fixture should have LM-79/LM-80 certificates and same are to be submitted before approving of fixture. |
| 70 | Supply, Installation testing and commissioning of 1200mm sweep Ceiling Fans of Compton Greaves / Havel\"s / Usha /Bajaj make ( Sample to be got approved ) Complete incl making of necessary connections |
| 71 | Circuit / sub-main wiring along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of Polycab /Havells / Finolex /Anchor in recessed or surface conducting system excluding cost of conduit of following sizes. |
| 72 | 12 x 2.5 SQ. mm + 1 x 2.5 SQ. MM Earth Wire |
| 73 | 2 x 4 SQ. mm + 1 × 4 SQ. MM Earth Wire. |
| 74 | 2 x 6 SQ. mm. For Normal Lighting Sub main |
| 75 | 12 x 10 SQ. mm + 1 x 10 SQ. MM Earth Wire. For Heating submain |
| 76 | Supply and Fixing of 25 mm dia medium grade PVC conduit incl its allied accessories like bends etc for laying of wires recessed in floors /walls through conduits. as per site requirement and as directed |
| 77 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) of Legrand / Siemens/ ABB /Schneider /L&T make 16 way, SPM Double door |
| 78 | Supplying and fixing of 5 Amps to 32 Amp S Pole rating 240/415 volts (10 kA) \"C\" curve MCB of Legrand / Siemens/ ABB/Schneider /L&T make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required. |
| 79 | Supplying and fixing of 63 Amp rating DP 240/415 volts (10 kA) \"C\" curve MCB\"s Legrand /Siemens/ ABB/Schneider /L&T make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required. |
| 80 | Changing over Switch |
| 81 | P/F of 10 Sq.mm Service line of approved make |
AI Tender Summary
Tender Timeline
Oct 04, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedOct 11, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 12, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender