| 1 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 2 | Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 3 | Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 4 | Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 5 | Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 6 | Reinforcedcementconcreteworkinbeams,suspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges |
| 9 | providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. (a) 10mm (TMT coilFe 500) {Only Vaild for Tata(Tiscon), Sail, JSPL,ElectrosteelSteels Ltd. Bokaro,and Vizag (RINL) } |
| 10 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 11 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. |
| 12 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 13 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 15 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 16 | Stainless steel wire guage (Grade-304) a[erture 1.4 mm and 0.50 mm dia wire (For Three Track Aluminium Shutter) |
| 17 | Renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer. |
| 18 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 19 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 20 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 21 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 22 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 23 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated andgroutedwithfinesand,includingnecessaryexcavation,levelling& dressing & finishing the top smooth. |
| 24 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 25 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 26 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 27 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/ltr and viscosity 70 -160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C.Cold flexibility shall be upto -2°C when tested in accordance with ASTM,D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane. |
| 28 | Providing and filling of 6 mm thickGroove between 25 mm PCC Panels with Polysulphide Sealant(Poring Grade)as per drawings and technical specifications and direction of E in Charge.(with18% |
| 29 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 30 | Coupler 110 mm |
| 31 | Shoe 110 mm |
| 32 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia |
| 33 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 34 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 35 | Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I. |
| 36 | Marble stone flooring with 18mm thick marble stone as per sample of marble shall be approved by Engineer-in-charge over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with :Udaipur green marble |
| 37 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 38 | Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete. |
| 39 | Providing and laying Doublecharge vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with water absorptionless than 0.08% and conforming to IS: 15622 / ISO 13006 of approvedmake, in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 40 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm. |
| 41 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 42 | Taking down R.W.D. Pipe carefully stacking on the ground and refixing the same in proper place after cleaning at throughly all complete as per direction of E/I. |
| 43 | Carriage of Materials :- |
| 44 | Sand with lead (1K+8P) 9 Km/Dust |
| 45 | Stone Chips with lead (1K+7P) 8 Km |
| 46 | Stone Metal with lead8 Km |
| 47 | Bricks with lead (1+7) Km |
| 48 | Providing and fixing male ended 15 mm dia brass bib cock of approved quality ( wt not less than 350 gms ) with extra socket all complete as per specification and direction of E/l . |
| 49 | Providing and fixing N.P/C.P brass/P.V.C porcelain shower rose of 15mm inlet etc. all complete as per specification and direction of E/l Shower Rose -125 mm |
| 50 | Providing and fixing 15mm size C.P brass pillar cock (Weight not less than 350 gms) C.I body brass spindle pillar cock of approved quality as per spcification and direction of E/l. |
| 51 | Providing and fixing brass / C.I. Stop cock of approved quality all complete as per specification and direction of E/l .15 mm dia |
| 52 | Providing and fixing G.M. non return valve Horizontal / vertical type of approved quality as per specification and direction of E/l. |
| 53 | Horizontal - 25 mm dia |
| 54 | Horizontal - 32 mm dia |
| 55 | Making holes in walls for laying G.I pipes and restoring the same after pipe laying as per specification and direction of E/l |
| 56 | (a) 125 mm thick wall. |
| 57 | (b) 250 mm thick wall. |
| 58 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/l. |
| 59 | Mirror (300x450 mm) 6mm thick plate glass bevelled edgemirror including C.P. Brass revolvingfittings 3 mm ply wood boardand C.P.Hinges to fixwith mirror. |
| 60 | C.P. brass towel Rail 20mm X 600mmwith bracketcontainer |
| 61 | C.P brass liquid shop dish container medium quality with screw and hinges etc. |
| 62 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., \"p\" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. |
| 63 | (A) 580 mm longwith 12.5 liter low level cistern |
| 64 | Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with \"p\" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. |
| 65 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed c.l. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l. |
| 66 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 67 | 250 mm dia. R.C.C. pipe |
| 68 | Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750 mm deep, 600 x 450 internal dimension having 250 mm wall thickness in cement mortar ( 1:6 ) including 3 mm cement plaster ( 1:4 ) with punning on inside and cement plaster (1:6 ) with 600 x 475 mm G.I. cover with frame (Weight not less than 36 Kg.) in foundation andrefilling all complete as per specification and direction of E/l. |
| 69 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. |
| 70 | 75 mm diameter |
| 71 | 110 mm diameter |
| 72 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 73 | Single tee without door 75x75x75 mm |
| 74 | Single tee without door 110x110x110 mm |
| 75 | 75 mm bend |
| 76 | 110 mm bend |
| 77 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 78 | 15 mm nominal outer dia.Pipes. |
| 79 | 20 mm nominal outer dia.Pipes. |
| 80 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 81 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 82 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with piano type switch phenolic laminated sheet, suitable size PVC / GI box etc. as required. Group c |
| 83 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required. |
| 84 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 85 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizesPVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required |
| 86 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 87 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 88 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 89 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 90 | 5/6 amps switch, one way switch |
| 91 | 3 pin 5/6 amp socket outlet |
| 92 | 15/16 amps switch, one way switch |
| 93 | 6 pin 15/16 amp S.S combined |
| 94 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 95 | Supplying and fixing suitable size GI/PVC boxon surface or in recess,withphenolic laminated sheet cover in front including providing and fixing 5 pin 5/6 ampssocket outlet and 5/6 amps piano type switch, connection,painting etc. as required. |
| 96 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection,painting etc. as required. |
| 97 | Supplying and fixing2 pin 5 amp Ceiling rose on the existing junction box/ wooden blockincluding connection etc. as required. |
| 98 | Supplying and fixingbatten/ angle holder including connection etc. as required. |
| 99 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 100 | Supply of 9/10 watt LED blub |
| 101 | S.I.T.C. of Followingrating surface mounted LED tube light fittings suitable for 230 V 50 Hzsingle phasesupply etc.Completeas requirement 220/22W LED Tubelight |
| 102 | Recess mounting LED Round down light (12 W) |
| 103 | Supplying and fixing of bilk head fitting with 9/10 watt CFL/LED |
| 104 | Supply LED street light (45/48W) |
| 105 | Supply and installation, Testing and commissioningof followingsizeceiling fan 3 bledsconfirmingto IS: 374: 2019including wiringthe downrods of standardslength(upto 30cm)with1.5 sq . MmFRPVCinsulated , copperwiresuiteblefor 230 V 50 Hz , singlephasesupply etc.complete as required. 1200mm (48\")Ceiling Fan |
| 106 | Supplying fitting and fixing and testing of 9\" (230mm) metal exhaust fan. |
| 107 | Supplying fitting and fixing and testing of 16\" (400mm) metal exhaust fan. |
| 108 | Stone crusher dust finer than 3 mm with not more than 10% passing 0.075 sleves at Quarry all complete job as per direction of E/I |
| 109 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer-in-charge. |
| 110 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil itemA) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 111 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 112 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 113 | Providing designation 75B brick work inC.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 114 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 115 | Providing designation 12 mm C.P. (1:3) with1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I. |
| 116 | Cost of Drilling 200mmx165mmx125 mm meter Deep borewell in all kinds of soil and rock in rural area for installation of pump set with Hydraulic DTH Rig machine, all complete including supplying all materials , tools , drilling rig, Air Compressor and equipment, as well as fuel, lubricants and cost transportationof Rig machine and other vehicles up to the site. |
| 117 | (a) From 0.00 Mtr to 50.00 Mtr below G.L |
| 118 | (b) From 51.00 Mtr to 200.00 Mtrbelow G.L |
| 119 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. |
| 120 | Supplying all materials Labours ,tools ,equipments for cleaning ,flushing & developing the borewell till clear and potable discharge of water etc . all complete job as per direction of E/I |
| 121 | Supplying submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various Rpolypropylene/ noryl impeller. Motor suitable for working on OF JHARKHAND SCHED ND SCHEDULE OF RATES RAT delivery head and discharge with stainless steel pump shaft and AND SCEDULE OF RATE 415V+10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust HARKHAN SCHEDULE OF Carbon/ fiber bearing to withstand entire hydraulic thrust, water ENT OF JHARKHAND SCH RKHANDCHEDU OF R RKRAD SCHEDULE proof winding shall be provided. The pump set shall be suitable CHOULE OF RATES GOVERNMENT CHARKHA JHARKHAND SCHEDULE for direct coupling. Pump shall have suitable outlet as per PULL OF RAIL GOVERNMENT OF HAKHAND manufacturers design. Anti thrust stream lined non return valve RNMENT OF ARKHAND ERNMENT OF JHARKHAND SC RNMENT OF JHARKHAND S ERNMENT OF HARKHAND shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided each pump. JHAR HA HANN HAN witheach pump- Submersible Pump set 100 mm dia (with Polypropylene/Norly lmperller) up to 20 stages |
| 122 | 2.H.P |
| 123 | Supplying 3 core PVC insulated PVC sheathed copper conductor flat submersible cable. 2 core 4 sq. mm |
| 124 | Supplying and fitting MS clamp of required dia to the top of casing/ housing pipe of tube well as per IS 2800 (Part I), including necessary bots & nuts of required size of all complete job as per direction of E/I200 mm clamp |
| 125 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work 32 mm nominal outer dia. Pipes. |
| 126 | Add 18 % GST (in Basic Rate must fill 12) |
| 127 | Add 1% Labour Cess (in Basic Rate must fill 1) |