Tender For Special Repair And Replacement Of Point Wiring And Electrical Fittings Fixtures At Md Accn Bldgs Pmt801, Pmt802, Pmt803, Pmt804, Pmt805, Pmt806, Pmt807, Pmt808 At Bn Hq Ghaspani., Dimapur-Nagaland

Assam Rifles-AR has published Tender For Special Repair And Replacement Of Point Wiring And Electrical Fittings Fixtures At Md Accn Bldgs Pmt801, Pmt802, Pmt803, Pmt804, Pmt805, Pmt806, Pmt807, Pmt808 At Bn Hq Ghaspani.. Submission Date for this Tender is 23-10-2023. Electrification Work Tenders in Dimapur Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

39977167
Tender For Special Repair And Replacement Of Point Wiring And Electrical Fittings Fixtures At Md Accn Bldgs Pmt801, Pmt802, Pmt803, Pmt804, Pmt805, Pmt806, Pmt807, Pmt808 At Bn Hq Ghaspani.
Open Tender
Indian
Nagaland
Dimapur
23-10-2023

Tender Details

Special Repair And Replacement Of Point Wiring And Electrical Fittings Fixtures At Md Accn Bldgs Pmt801, Pmt802, Pmt803, Pmt804, Pmt805, Pmt806, Pmt807, Pmt808 At Bn Hq Ghaspani.

Key Value

Document Fees
INR 1000 /-
EMD
INR 70600.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : Special repair and replacement of point wiring and Electrical Fittings/Fixtures at Md accn Bldgs PMT-801,PMT-802,PMT-803,PMT-804, PMT-805, PMT-806,PMT-807,PMT-808 at Bn HQ Ghaspani.
Sl. No. Item Description
1SCHEDULE ‘A’ PART - I (Internal Electrifications)
2Rewiring of light point/ fan point /exhaust fan point / call bell point with 1.5 sqmm FR PVC insulated conductor single core cableand 1.5 sqmm FR PVC insulated copper conductor single core cable as steel conduit including dismantling as required.
3Rewiring of twin control light point with 1.5 sqmm FR PVC insulated copperconductor single core cable and 1.5 sqmm FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.
4Supplying and fixing 1 or 2 module (75mmx75mm) modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
5Supplying and fixing 4 modules (125mm x75mm) modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
6Supplying and fixing 6 modules (200mmx75mm) modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
7Supplying and fixing of 1 or 2 modulemodular base & cover plate on existing modular metal boxes etc as required.
8Supplying and fixing of 4 modulemodular base & cover plate on existing modular metal boxes etc as required.
9Supplying and fixing of 6 modulemodular base & cover plate on existing modular metal boxes etc as required.
10Supplying and fixing 5/6 amps modular switch on the existing modular plate & switch box including connection but excluding modules plate etc as required
11Supplying and fixing 2 way 5/6 amps modular switch on the existing modular plate & switch box including connection but excluding modules plate etc as required
12Supplying and fixing 15/16 ampmodular switch on the existing modular plate & switch box including connection but excluding modules plate etc as required
13Supplying and fixing 3 pin 5/6 amp modular socket outlet on the existing modular plate & switch box including connection but excluding modules plate etc as required
14Supplying and fixing 6 pin 15/16 ampmodular socket outlet on the existing modular plate & switch box including connection but excluding modules plate etc as required
15Supplying and fixing Bell Push on the existing modular plate & switch box including connection but excluding modules plate etc as required
16Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 No. 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
17Supply and fixing call bell Suitable for single phase 230 volts complete as required.
18Supping and fixing 3 pin 5 amp ceiling rose on the existing junction box etc as required.
19Installation, testing and commissioner of pre-wired florescent fitting/compact fluorescent fitting of all types with all accessories and tube etc, directly on ceiling/wall including connetion with 1.5 sqmm FR PVC insulated, copper inductor, single core cable and earthing etc as required.
20Earthing with copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc with charcoal/ coke and salt as required.
21Supplying and laying 25mmx5mm copper strip at 0.50 meter below ground as strip electrode, including connection/ termating with nut bolt spring washer etc as required.
22Supplying and fixing 2+6 way double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
23Supplying and fixing 2+8 way double door , single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
24Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.
26Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
27Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
28Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.
29Wiring for circuit/ submain wiring along earth wire with the 2x10 sq mm+1x6 sq mm earth wire FR PVC insulated copper conductor, single core cable in casing caping as required.
30Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (two or more coats) including prepariong surface by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
31SCHEDULE OF CREDIT :-Unserviceable all type of switch, socket, ceiling rose etc.
32Unserviceable light point/ fan point /exhaust fan point / call bell point all type of wire
33Unserviceable all type of MCB box with MCB etc