Assam Rifles-AR has published Tender For Special Repair And Replacement Of Point Wiring And Electrical Fittings Fixtures At Md Accn Bldgs Pmt801, Pmt802, Pmt803, Pmt804, Pmt805, Pmt806, Pmt807, Pmt808 At Bn Hq Ghaspani.. Submission Date for this Tender is 23-10-2023. Electrification Work Tenders in Dimapur Nagaland. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | SCHEDULE ‘A’ PART - I (Internal Electrifications) |
2 | Rewiring of light point/ fan point /exhaust fan point / call bell point with 1.5 sqmm FR PVC insulated conductor single core cableand 1.5 sqmm FR PVC insulated copper conductor single core cable as steel conduit including dismantling as required. |
3 | Rewiring of twin control light point with 1.5 sqmm FR PVC insulated copperconductor single core cable and 1.5 sqmm FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. |
4 | Supplying and fixing 1 or 2 module (75mmx75mm) modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
5 | Supplying and fixing 4 modules (125mm x75mm) modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
6 | Supplying and fixing 6 modules (200mmx75mm) modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
7 | Supplying and fixing of 1 or 2 modulemodular base & cover plate on existing modular metal boxes etc as required. |
8 | Supplying and fixing of 4 modulemodular base & cover plate on existing modular metal boxes etc as required. |
9 | Supplying and fixing of 6 modulemodular base & cover plate on existing modular metal boxes etc as required. |
10 | Supplying and fixing 5/6 amps modular switch on the existing modular plate & switch box including connection but excluding modules plate etc as required |
11 | Supplying and fixing 2 way 5/6 amps modular switch on the existing modular plate & switch box including connection but excluding modules plate etc as required |
12 | Supplying and fixing 15/16 ampmodular switch on the existing modular plate & switch box including connection but excluding modules plate etc as required |
13 | Supplying and fixing 3 pin 5/6 amp modular socket outlet on the existing modular plate & switch box including connection but excluding modules plate etc as required |
14 | Supplying and fixing 6 pin 15/16 ampmodular socket outlet on the existing modular plate & switch box including connection but excluding modules plate etc as required |
15 | Supplying and fixing Bell Push on the existing modular plate & switch box including connection but excluding modules plate etc as required |
16 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 No. 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
17 | Supply and fixing call bell Suitable for single phase 230 volts complete as required. |
18 | Supping and fixing 3 pin 5 amp ceiling rose on the existing junction box etc as required. |
19 | Installation, testing and commissioner of pre-wired florescent fitting/compact fluorescent fitting of all types with all accessories and tube etc, directly on ceiling/wall including connetion with 1.5 sqmm FR PVC insulated, copper inductor, single core cable and earthing etc as required. |
20 | Earthing with copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc with charcoal/ coke and salt as required. |
21 | Supplying and laying 25mmx5mm copper strip at 0.50 meter below ground as strip electrode, including connection/ termating with nut bolt spring washer etc as required. |
22 | Supplying and fixing 2+6 way double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
23 | Supplying and fixing 2+8 way double door , single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
24 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
25 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
26 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
27 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
28 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
29 | Wiring for circuit/ submain wiring along earth wire with the 2x10 sq mm+1x6 sq mm earth wire FR PVC insulated copper conductor, single core cable in casing caping as required. |
30 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (two or more coats) including prepariong surface by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
31 | SCHEDULE OF CREDIT :-Unserviceable all type of switch, socket, ceiling rose etc. |
32 | Unserviceable light point/ fan point /exhaust fan point / call bell point all type of wire |
33 | Unserviceable all type of MCB box with MCB etc |