Tender For Repair/ Maint Work For Internal Electrification, Rewiring, Ceiling Fans, Geysers Incl Their Parts And Repair/Maint Of Dg Set With Amf Panel,Voltage Stabiliser, Lightening Conductor,Garden Lights At Age Charduar Area Under Ge (N) Tezpur, tezpur-Assam

Military Engineer Services-MES has published Tender For Repair/ Maint Work For Internal Electrification, Rewiring, Ceiling Fans, Geysers Incl Their Parts And Repair/Maint Of Dg Set With Amf Panel,Voltage Stabiliser, Lightening Conductor,Garden Lights At Age Charduar Area Under Ge (N) Tezpur. Submission Date for this Tender is 31-10-2023. Electrification Work Tenders in tezpur Assam. Bidders can get complete Tender details and download the document.




Tender Notice

39973762
Corrigendum : Tender For Repair/ Maint Work For Internal Electrification, Rewiring, Ceiling Fans, Geysers Incl Their Parts And Repair/Maint Of Dg Set With Amf Panel,Voltage Stabiliser, Lightening Conductor,Garden Lights At Age Charduar Area Under Ge (N) Tezpur
Open Tender
Indian
Assam
tezpur
31-10-2023

Tender Details

Repair/ Maint Work For Internal Electrification, Rewiring, Ceiling Fans, Geysers Incl Their Parts And Repair/Maint Of Dg Set With Amf Panel,Voltage Stabiliser, Lightening Conductor,Garden Lights At Age Charduar Area Under Ge (N) Tezpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-10-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 94000.0 /-
Tender Value
INR 47 Lakhs /-

BOQ Items

Name of Work: REPAIR/REPLACEMENT MAINT WORK FOR INTERNAL ELECTRIFICATION, REWIRING WORK, CEILING FANS, GEYSERS INCL THEIR PARTS AND REPAIR/MAINT OF DG SET WITH AMF PANEL,VOLTAGE STABILISER, LIGHTENING CONDUCTOR,GARDEN LIGHTS AND CONNECTED ACCESSORIES ANDALLIED WORKS AT AGE CHARDUAR AREA UNDER GE (N) TEZPUR
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring (light, fan socket or power ) completefitting such as switches , ceiling rose pendent , regulators , sockets light fitting etcto be measured separately) removing material from siteand making good disturbed surface of wall floor etc complete all as specified and as directed.
2Material and labour for point wiring with 1.5 sqmm (nominal area)PVC insulated and sheathedmultistranded copper conductorcable FRLSH 1100 volts gradedrawn in and includingPVC casing & capping of suitable size including all accessiries fixed to wall/ceiling including PVC closed recessed boxes ISI markedwith 3.00 mm thick plastic laminated sheet top cover as per manufacturer"s design for mounting of switches, sockets or regulators etcincluding1.50 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade single core as earth continuity conductorand connected to common earth dolly for following:- Note:These point wiring is not necessary to be full bldg part it may part of bldg/certain point of bldg. (a) One light /fan point controlled by one switch.
3(b) One bell /buzzer point controlled by one buzzer switch.
4(c ) One 3 pin socket outlet 5 Amps on same board with other switches.
5(d) One 3 pin socket outlet 5 Amps on indpendent board
6Ditto all as per item No.2 above but with 2.50 sqmm single core multistranded copper conductor cable for 15 Amp socket outlet point on independent board.complete all as specified and as directed.
7Supply and fix switch piano flush type single pole, one way, 5/6 Amps complete all as specified and directed.
8Supply and fixsocket 2 in one , 5 pin 5 Ampsflush type, universal complete all as specified and directed.
9Supply and fix Switch socket combination 2 in one , 5 pin 5 Ampsflush type, universal complete all as specified and directed.
10Supply and fixofswitch socket combination 2 in one , 5 pin 5 Amps & 15 Amps flush type, universal complete all as specified and directed.
11Supply and fix bell push flush type 5 Amps complete all as specified and directed.
12Supply and fix call bell Ding dong AC 230 Volts single pole complete all as specified and directed.
13Supply and fix lamp holder PVC/Polycarbonate type with back plate suitable for batten fitting, straight or angular type complete all as specified and directed.
14Supply and fix fan regulator electronic step type 230 V AC complete all as specified and directed.
15M&L ceiling rose,surface bakelite 65x50mm two to three terminal complete all as specified and directed.
16S& F surface and wall mounted LED T/L Fitting with wide angle profile high lumen with efficiency of 100 lumens batten extruded aluminium housing provided for efficient heat dissipation with polycarbonate housing & integrated electronic driverincluding LED tube light 20 watt3000K-6500K 4 feet complete all as specified and directed. Make:Surya Cat part NoSLE BT 20 NEO or any equivalent make.
17S& F Recess mounted SQUARE shaped 1"x1" size LED downlighter with durable housing with AIuminium heat sink with PC diffuser in white powder coated finish with integrated driver to give glare free light with removable driver 15 W LED 3000K-6000K complete all as specified and directed.Make SURYA CAT Part No ATHENA SLE DLR 15 WXXSQ or equivalent (note these fitting should matched the existing fittingand white/cool day as per requirement at site)
18S& F Recess mounted roundLED downlighter with durable housing with AIuminium heat sink with PC diffuser in white powder coated finish with integrated driver to give glare free light with removable driver 12 W LED 3000K-6000K complete all as specified and directed.Make SURYA CAT Part No ATHENA SLE DLR 12 W 6K RD or equivalent (note these fitting should matched the existing fittingand white/cool day as per requirement at site)
19S& F Recess mounted SQUARE shaped 2"x2" size LED downlighter with durable housing with AIuminium heat sink with PC diffuser in white powder coated finish with integrated driver to give glare free light with removable driver 36 W LED 3000K-6000K complete all as specified and directed.MakeSURYACAT PArt No TROFFER SLE DS 36 22 R or equivalent make.
20Supplying andfix sheet metalenclosure forDB’s when MCB’s to beused of 240 volt 4way with 200 amps rated bus bar SPN doubledoorcomplete all asspecified anddirected. Make: L&T/ABB/SCHNIEDER/LEGRAND: MCB Should be fix in separate ktems.
21Supply andfix sheet metalenclosure forDB’s when MCB’s to beused of 240 volt 8way with 200 amps rated bus bar SPN doubledoorcomplete all asspecified anddirected.L&T/ABB/SCHNIEDER/LEGRAND Note : MCB Should be fix in separate ktems.
22Supplying andfix sheet metalenclosure forDB’s when MCB’s to beused of 240 volt 2 way with 200 amps rated bus bar SPN doubledoorcomplete all asspecified anddirected.L&T/ABB/SCHNIEDER/LEGRAND : MCB Should be fix in separate items.
23S& F MCBsinglepole 6amps to 16 amps , C series complete all asspecified anddirected. Note:- MCB Rating shall be suitable to the existing DB .Make- L&T Cat Part No BB10320C/AAB/LEGRAND or equivalent
24Supply and fixMCB single pole & neutral 240 volts 20-32 Amps, 10 KA , C Series complete all as specified and directed. Note:- MCB Rating shall be suitable to the existing DB.Make- Cat Part NoBB20320C or equivalent make
25M&L for providing fan hook made out of MS round bars of 20 mm dia cut to size and made to shape hanging from roof supporting bars to the required length up to the ceiling level including shackle type rubber bush, MS clamp, nuts, bolts, washers etc, complete all as specified and as directed.
26Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) including hanging up the light without remote. complete all as specified and as directed.
27M & L for submain wiring withtwo runs of PVC insulated multistranded,copper coductor of size 4 Sqmmcable single core 1100 Volts Gradeand one run ofearth continuity conductor cableof 4 Sq mm solid strand cable drawn in and incl 30/32 mm PVC casing caping complete all as specified and as directed. Note:- 2 run of 4sqmm cable+ 1 run of 4sqmm earthed cable+ 1 run of casing capping shall be measured as one unit. complete all as specified and as directed.
28M & L for submain wiring withtwo runs of PVC insulated multistranded,copper coductor of size 6 Sqmmcable single core 1100 Volts Gradeand one run ofearth continuity conductor cableof 6 Sq mm solid strand cable drawn in and incl 30/32 mm PVC casing caping complete all as specified and as directed. Note:- 2 run of 6sqmm cable+ 1 run of 6sqmm earthed cable+ 1 run of casing capping shall be measured as one unit. complete all as specified and as directed.
29Supply and fixMCB changeover63 Amps, 10 KA , C Series complete all as specified and directed. Note:- MCB Rating shall be suitable to the existing DB.Make-havelles cat Part No-DHMGODPX063 or equivalent
30S&F metal clad socket out let with MCB three pole(3 P) 20 Amp including sheet metal enclosure complete 2nd class hard wood wooden board including complete electrical connection by proper size of copper lugs complete all as specified and directed.Havells Cat No DHDPUTN020 / DHDPUTN030
31S&F metal clad socket out let with MCB two pole(P+N) 20 Amp including sheet metal enclosure complete 2nd class hard wood wooden board including complete electrical connection by proper size of copper lugs complete all as specified and directed.Make Havells cat part No DHDPUSN020/DHDPUDP020
32M&L for earthing with galvanised iron earth plate electrode 60 cm x 60 cmx 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.5 metre below ground level surrounded from all sides 15 mm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using earth lead GI wire 4mm dia(8 SWG)by means of bolts, nuts, check nuts and washers of galvanisediron or steelconnected to common earth dolly and protected by galvanised iron light grade pipe 15 mm bore in wall/floor and including 20 mm galvanised pipe for watering with funnel and wire meshall as specified or indicated including excavation and connected earth work, in soft/loose soil, PCC1:3:6 type C1 using 20mm graded stone aggregate as in pit andRCC 1:2:4 type B1 cover for earth pit cover reinforced with 8 mm dia TMT Bars @ 75mm C/C both ways and with handle made out of 08mm dia bars,GI funnel, strainer, including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part I and testing on completion , complete all as specified and directed.
33Supply, fixing and passing through service bracket, 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4mm suspension wire one twin core cable of size 6 Sqmm including taking down old complete all as specified.
34Supply, fixing and passing through service bracket, 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4mm suspension wire one twin core cable of size 10 Sqmm including taking down old complete all as specified.
35Supply, fixing and passing through service bracket, 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4mm suspension wire one twin core cable of size 16 Sqmm including taking down old complete all as specified.
36Supply only 15W LED new adore 15W B22 cool day light ball lamp all as specified and directed. Make HavellsCatNo CLASSYLED 15 W B22CDL 3 STAR
37Supply only 13 W LED new adore 13W B22 cool day light ball lamp all as specified and directed. Make HavellsCatNo CLASSYLED 13 W B22CDL 3 STAR
38Supply Only Insulation tap of Red,yellow,blue ,green or black colour for day to day complain and wiring working at 240 V ac and for phase must be colour and for neutral must be black colour . complete all as specified and as directed.
39Disconnecting of ceiling fans of 1200/1400 mm sweep from ceiling rose/connector for cleaning,servicing /oiling and greasing of fan by using appropriate grade of oil/greaseand re-hanging the same after proper cleaning and making connection with ceiling fan/connector with flexible wire of size 23/0076 copper conductor multi stranded complete all as specified and directed.
40Disconnecting of ceiling fans of 1200/1400 mm sweep from ceiling rose/connector for re-winding,servicing /oiling and greasing of fan by using appropriate grade of oil/grease and replacing defective parts such as bush bearing , split pin rubber bush, capacitor etc and re-hanging the same after proper cleaning and making connection with ceiling fan/connector with flexible wire of size 23/0076 copper conductor multi strandedcomplete all as specified and directed. (NOTE :- Parts/spares will measured and paid separtely under relevant item of the schedules).
41Rewinding of ceiling fan 1200 mm sweep AC 230 volts single phase with super enamelled copper winding wire of appropriate / existing gauge / size including packing, insulating material soldering varnishing, assembling and testing material soldering varnishing, assembling and testing including transportation charges to and from contractor"s workshop complete all as specified and directed.
42Rewinding of ceiling fan 1400 mm sweep AC 230 volts single phase with super enamelled copper winding wire of appropriate / existing gauge / size including packing, insulating material soldering varnishing, assembling and testing material soldering varnishing, assembling and testing including transportation charges to and from contractor"s workshop complete all as specified and directed.
43S&F bearing of ceiling fans for ceiling fans of 1200/1400mm sweep to suit for different makes of fans of approved quality including necessary greasing complete all as specified and directed. Make- NBC/SKF/NORE/TATA
44S&F bushes gun metal suitable for ceiling fans 1200/1400mm sweep complete all as specified and directed.
45S&F rubber bushes and reel type synthetic rubber with 14.5 mm hole suitable for fan hooks for hanging of ceiling fans complete all as specified and directed.
46S&F split pins of galvanised iron 1/8" dia, 2 length all as approved by Engr in charge complete all as specified and directed.
47S&F down rod 30cms long made out of heavy grade MS pipe with necessary threading at both ends holes as required with suitable matching colour of ceiling fan 1200/1400mm complete all as specified and directed.
48S&F top/bottom canopy of required size complete with tightening screws complete all as specified and directed.
49S&F condenser/capacitor suitable for 230 volts single phase ceiling fan 1200mm /1400 sweep of any make and quality of capacity 2.5 MFD complete all as specified and directed. Make- Bajaj/Havells/Usha.
50S&F condenser/capacitor suitable for 230 volts single phase ceiling fan 1200mm /1400 sweep of any make and quality of capacity 3.15 MFD complete all as specified and directed. Make- Bajaj/Havells/Usha
51S&F condenser/capacitor suitable for 230 volts single phase exhaust fan 300mm to 450 sweep of any make and quality of capacity 4 MFD complete all as specified and directed. Make- Bajaj/Havells/Usha
52S&F body screw and blade screw of ceiling fan 1200mm/1400 mm sweep off sizes complete all as specified and directed.
53Taking down exhaust fans any size, sealing cable end, and dismantling blade and removing fan and blade to contractor workshop for repair/overhauling etc complete all as specified and directed.
54Rewinding of exhaust fan 300mm to 450mm sweep AC 230 volts single phase with super enamelled copper wire of appropriate size including packing insulating material, soldering, varnishing, assembling and testingincluding transportation charges to and fro from contractor"s workshop complete all as specified and directed.
55S&F ball bearing suitable for exhaust fan 300 to 450mm sweep of different Makes complete all as specified and directed. Make- NBC/SKF/NORE/TATA
56S&F fan blade (ISI Marked) complete with tightening bolts/screws, made of aluminium suitable for any make and colour of exhaust fan complete all as specified and directed. Make- Bajaj/Havells/Usha/CG
57S&F Exhaust fan 300 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi strandedcopper wire of appropriate size includingtesting complete all as specified and directed.
58S&FExhaust fan 450 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi strandedcopper wire of appropriate size includingtesting complete all as specified and directed.
59S&F Exhaust fan fresh air 250 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi strandedcopper wire of appropriate size includingtesting and fixing will be done in appropriate existing hole with fixing of sheet required is deemed to be inculded in the rate complete all as specified and directed.
60Disconnecting / taking down water heaters (Geysers) of any make & capacity, horizontal or vertical type their existing locations, for carrying out overhauling / repairs fromcomplete all as specified and directed.
61Overhauling, repairing, reassembling, refixing, installation of water heaters / Geysers to their original position, making all necessary water & electric connections and testing complete all as specified and directed. Note-(Parts renewed shall be measured and paid separately under relevant items).
62Supply only heating element 1.5 KW (ISI Marked) suitable for geyser of 25 litres capacity, horizontal or vertical type complete all as specified and directed. Note:these heating element must be suitable for existing geyser of different make.
63Supply only heating element 2 KW (ISI Marked) suitable for geyser of 50litres capacity, horizontal or vertical type complete all as specified and directed. Note:these heating element must be suitable for existing geyser of different make.
64Supply only thermostat (ISI Marked), minimum 300 mm long, suitable forgeyser 25/50 litrescapacity horizontal or vertical type complete all as specified and directed.
65Supply only indicating lamp (ISI Marked) for geysers complete all as specified and directed.
66Supply only door assembly (ISI Marked) comprising of inlet & outlet thermostat housing with gasket complete with bolts, nuts, washers, washers screws & packing etc. suitable for 25 litres capacity horizontal or vertical geysers complete all as specified and directed.
67Supply only door assembly (ISI Marked) comprising of inlet & outlet thermostat housing with gasket complete with bolts, nuts, washers, washers screws & packing etc. suitable for 50 litres capacity horizontal or vertical geysers complete all as specified and directed.
68Supply and filling up glass wool (ISI Marked) for geysers of 25 litrescapacity complete all as specified and directed.
69Supply and filling up glass wool (ISI Marked) for geysers of 50 litrescapacitycomplete all as specified and directed.
70M&L for repairing leakage of inner copper/stainless steel tank of geyser (any make), 25 litres capacity by brazing includinggas welding from outside/on site necessary welding for repair of leakageand material included items complete all as specified and directed.
71M&L for repairing leakage of inner copper/stainless steel tank of geyser (any make), 50 litres capacity by brazing including includinggas welding from outside/on site necessary welding for repair of leakageand material included, all necessary denting etc. complete all as specified and directed.
72Renewal of inner stainless steel container of geyser (any make), 25 litres capacity by brazing including all necessary asseccories etc. complete all as specified and directed.
73Renewal of inner stainless steel container of geyser (any make), 50 litres capacity by brazing including all necessary asseccories etc complete all as specified and directed.
74S&F top cover of geyser suitable for 25 Ltr cap complete with screw, washer etc complete all as specified and directed.
75S&F (in repair) for PVC connection 15 mm dia with brass ferule both end length 450 mm complete all as specified and directed.
76Supply only twisted flexible cord PVC insulated, 3 core, 23/0.0076 complete all as specified and directed.
77S&F (in repairs) fancy type chromium plated stop cock with brass spindle & with crutch or butterfly handle screwed down high pressure suitable for 15 mm bore GI tubing complete all as specified and directed.
78S&F Bib taps, cast copper alloy with crutch handle, screwed for 15 mm bore dia iron pipe or for brass ferrule complete all as specified and directed.
79S&F fuseable plug suitable for any type of storage water heater of any makecapacity complete all as specified and directed.
80S&F (in repairs) Gun metal non-return valve,suitable for 15 mm bore GI tubing complete all as specified and directed.
81S&F pressure releasing safety valve ISI marked complete all as specified and directed.
82S&F plug top polycarbonate 3 pin, 16 Amp complete all as specified and directed. Make-Anchor Cat No-38637or equivalent of (I) HAVELLS ((II) LEGRAND (III) SCHNIEDER
83Supply,installation testing and commissioning of storage type water heater 25 ltrs capacity vertical mounting type complete made out of CRCA outer body, stainless steel storage tank, heating element,thermostat,thermal cut out, glass wool etc. complete including making necessary electrical connections with suitable size copper multistranded cable complete all as specified and directed.
84S&F in repairs prepainted inspection plated rounded in two pieces made out of 22 gauge MS sheet and with fixing space for indicating lamp of any type and make of Geyser 25/50 ltrs capacity including fixing screws complete all as specified and directed.
85Dismantling any type and capacity of geysers and re-fixing after descalling of geyser tank 25/50 Ltrcapacity including geysers and element holding assembly complete all as specified and directed.
86S&F Sheet metal enclosures Single door SPN, 2 ways suitable for mounting MCB complete all as specified and directed.
87S&F MCBSPN,6 to 32 Amps, 240 Voltsto be housed in DBs catered here in after complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are including in unit rate of each MCB of any rating)
88Taking up or down steel tubing and connections, including removal of 15 mm bore complete all as specified and directed. Note-(Excavation and earthwork deemed to be included in the rate.
89Supplying, laying, jointing and testing 15 mm nominal bore steel water tubes"medium grade", galvanised, with all fittings, laid in trenches or fixed to wall complete all as specified and directed.
90Refixing old steel tubing and connections in new and old position walls,ceiling, floors etc.) of following bore complete all as specified and directed.
91S&F GI nipple, 15 mm bore, medium grade upto 150 mm length complete all as specified and directed.
92S&F pvc flexible conduit for cable/wire proper connection and make surface good to all existing connection of post top enegy saving lamp/bollard light,garden light,street light etc. complete all as specified and as directed.
93Supply only twin twisted flexible cable, PVC insulated with stranded copper conductor of size 24/0.0076, AC 1100 volts grade complete all as specified and directed.
94Supply onlyswitch piano flush type single pole, one way, 15/16 Amps complete all as specified and directed.
95Supply only tube rodwith wide angle profile high lumen with efficiency of 100 lumens batten extruded aluminium housing provided for efficient heat dissipation with polycarbonate housing & integrated electronic driverincluding LED tube light 20 watt3000K-6500K 4 feet complete all as specified and directed. Make:Surya SLE TL DS 20 PC REFORM (NANO) or any equivalent make.
96Supply onlywall mounted LED T/L Fitting with wide angle profile high lumen with efficiency of 100 lumens batten extruded aluminium housing provided for efficient heat dissipation with polycarbonate housing & integrated electronic driverincluding LED tube light 20 watt3000K-6500K 4 feet complete all as specified and directed. Make:Surya Cat part NoSLE BT 20 NEO or any equivalent make.
97Supply onlycondenser/capacitor suitable for 230 volts single phase ceiling fan 1200mm sweep of any make and quality of capacity 2.5 MFD complete all as specified and directed.
98Supply onlycondenser/capacitor suitable for 230 volts single phase ceiling fan 1400 mm sweep of any make and quality of capacity 3.15 MFD complete all as specified and directed.
99Decanting of used lub oil from chamber/sump of the DG set of capacity 30 to 40 KVA and cleaning of chamber thoroughly to remove all types of deposites and supply & filling of new lub oil SAE 20 W/40 W at required level including replacement of all types of filters such as fuel filter, screen filter, oil filter etc. all as specified and directed.NOTE:- (i) Spares and engine oil shall be measured and paid separately under respective items.(ii) Periodicity/location of the DG set shall be intimated by Engr-in-Charge as and when required. (iii) Work shall be carried out at scattered locations at different sector.
100All as item No-99 hereinbefore but DG set of capacity 50 to 62.5 KVA. complete all as specified and as directed.
101Supply only the following spares of DG set :- (a) Oil filter
102(b) Fuel filter
103(c) Screen/Air filter
104M&L for taking out FIP from DG set and calibration of fuel injection pump as per standard calibration procedure for 30 to 62.5 KVA DG set including pressure cleaning og fuel nozzals,replacement of minor spares, gaskets etc and refixing the same at its original position including transportation to and fro and testing at site on full load all as specified and directed.
105labour for strip opening and taking out of cylinder head of 30 to 62.5KVA DG Set at site including dismantling of inlet/exhaust valves,pistons,head gasket, bearings of any description hose pipes fan belt etc all as required and setting/tunning up of DG set and replacement of faulty parts, gaskets etc,including turning/tappering of any parts at lath machine, re-assembling and testing complete all as specified and directed.Note: Spares shall be measured and paid separately.
106Supply & fix in replacement of the following worn out parts of existing size for DG sets of capacity 30 to 62.5 KVA complete all as specified and directed. Note: other minor item which are not inlisted belowdeemed to be included in item sl no 99 and 100 no other extra charge shall be provided for the same. (a) Cylinder liner
107(b ) Piston including pin and circlip-08
108(c) Piston ring set
109(d) Inlet/Exhaust valve
110(e) Valve lock
111(f) C R bearing
112(g) Liner O ring
113(h) By pass hose with clamps
114(j) Cupper washer set
115(k) Oil sump gasket
116(l) Water pump gasket
117(m) Fuel pipe suction/return
118(n) Injector over flow pipe
119(o) Valve seal
120(p) Fly wheel housing gasket
121(q) Head gasket
122(r) Turbo charger
123(s) Top cover gasket
124M&L for taking out unsv Turbo Charger from DG set and repair/overhauling/setting of Turbo Charger including replacement of charger kit for DG set of capacity 40 to 62.5 KVA and refixing the same with DG set and testing of DG set for smooth functioning complete all as specified and directed.
125M&L for rewinding of alternator with existing class copper super enamelled wire of existing gauge including servicing and overhauling, varnishing,drying and fixing insulating sleevs etc including transportation from site to workshop and back from workshop to site and refixing the same to its original position and testing at site on full load all as specified for DG set 40 to 62.5 KVA and as directed.
126M&L for rewinding of commutator/armature including servicing and overhauling, varnishing in field coil etc including transportation from site to workshop and back from workshop to site and refixing the same to its original position and testing at site all as specified for DG set 40 to 50 KVA and as directed.
127M&L for strip opening and rewinding of dynamo assy with super enamelled copper winding wire of existing gauge and insulation including insulating material and replacement of unsv parts such as carbon bush set,bush holder etc and refixing the same to its original position and testing on full load including taking out/dismantling of Dynamo assy from the DG set transporting it to workshop and back to site. Note:- Cost of any other essential spares required for repair shall be deemed included in unit rate quoted and no extra cost shall be paid for the same. complete all as specified and as directed.
128M&L for taking out/dismantling of water pump after disconnecting of radiator assy for complete repair and servicing of water pump replacement of kit,bearing etc for 40 to 62.5 KVA DG set including transportation from site to workshop and workshop to site incld distill water and other material used in cleaning with lath work if any for leakage and refixing the same to its original position including testing on completion.complete all as specified and as directed.
129M&L for taking out/dismantling of water pump after disconnecting of radiator assy for complete replacementof radiator assembly along with necessarykit,bearing etc for 40 to 50 KVA DG set including transportation from site to workshop and workshop to site and refixing the same to its original position including testing on completion.(Location: as per require where damage of radiator)
130Dismantling / taking down the governor assembly including all connected parts from DG set 30 KVA to 62.5 KVA and over hauling, calibration of fuel supply system,governor etc complete including renewal of wornout parts such as copper gasket, injector nozzle to maintain the desired fuel supply and provide fluctuation free output complete all as specified and directed.
131Draining out old used water with coolent from the radiator ofGen Set of capacity 30 KVA to 62.5 KVA capacity after disconnecting the water pipe, de-scaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and renewal of coolant solution complete all as directed by EIC.(Coolant shall be measured separatelyunder appropriate items).
132Supply, fixing, connecting, testing maintenance free battery, 12 volts, 180 Ah with lead acid terminals including initial charging of battery complete all as specified. (Make EXIDE / AMRON) including disconnection existing unserviceable battery.
133Supply, fixing, connecting, testing maintenance free battery, 12 volts, 150 Ah with lead acid terminals including initial charging of battery complete all as specified. (Make EXIDE / AMRON) including disconnection existing unserviceable battery.
134Dismantling and taking out unserviceable onload change over switch flush mounting type and supply & fixing new onload change over, 4 pole with front handle operated flush mounting of rating 100 Amps including making all electrical connections of incoming/outgong cables of any description/size with suitable size of lugs/thimbles,nuts,bolts & washers complete all as specified and directed.
135Supply & fixing in replacement battery charging sets 12V with transformer, rectifyre,DC Ammeter, DC voltmeter,charging rate selector switch with OFF/TRICKLE/BOOST including rewiring of faulty control circuit,suitable length of stranded copper conductor PVC cable 2.5 sqmm 3 run from power point to battery charger and 2 run from battery charger to battery etc suitable for 12 volt battery charging unitcomplete all as directed.Make: Elak or equivalent
136Supply & fix in replacement dynamo 12V suitable for DG sets of capacity 30 to 62.5 KVA complete all as specified and directed.
137Supply & replacement of rubber coupling of DG sets of capacity 40KVA complete including nuts,bolts and other connected items all as specified and directed.
138Supply & fix in replacement carbon bush holder suitable for DG sets of capacity 30 to 62.5 KVA complete all as specified and directed.
139Supply & fix in replacement carbon bush suitable for DG sets of capacity 30 to 62.5 KVA complete all as specified and directed.
140M&L for preparation of surface by scrapping existing painted surface and spray painting of canopy, alternator/diesel engine body, radiator base frame etc and applying one coat of synthetic enamel paint of existing colour and one coat of heat resistant paint of approved quality to engine and exhaust pipe including writing SM/MES No of DG set capacity 30 to 62.5 KVA all as directed by Engineer-in-charge.
141M&L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in to ground (earth pit) not less than 2.25 meters deep below GL with top edge of earth plate not less than 1.50 m below ground level, connected to GI strip of size 24x3mm. (7.50 m long) by means of nuts, bolts and washers, check nuts of GI and protected by the GI pipe light grade 1.5 mm nominal bore (7.50 m Long) for earth plead wire, watering pipe light grade of 20 mm nominal bore, 0.63 mm thick CI funnel, wire mesh etc complete including necessary earth work and excavation in any type of soil, PCC 1:2:4 type B1 earth pit and Precast RCC cover 50 mm thick dully reinforced with 6 mmdia, MS round bars @ 100 mm C/C both ways, earth testing point, making good to floor complete all as specified.
142Supply and fixing, in replacement, ofAutomatic Voltage Regulator (AVR) suitable for DG Set of 30 KVA to 62.5 KVA capacity of any make, with and including taking out old AVR and making all connection, testing for smooth functioning complete all as directed.
143Supply and fixing synthetic insulating mat of size 2mx1mx25mm suitable for working pressure 3.3 KV complete all as specified and directed.
144M&L for rewinding of excitor coil with existing size of super enamelled copper wire including necessary insulating material such as ampere tube tape,resin tape,applying F class varnishing and heating,drying up for better insulating resistance and testing after completion including commissioning complete all as specified and directed.
145M&L renewal of burnt battery lead heavy duty with & including 2.0 metre long copper conductor wire suitable for 30 KVA to 62.5 KVA DG set consisiting with suitable size of lugs and heavy duty terminal complete all as specified and directed.
146M&L for renewal of battery terminal heavy duty made out of brass suitable for 12 V lead acid battery.complete all as specified and as directed.
147Engine oil 20 W 40 suitable for DG sets of any capacity.complete all as specified and as directed.
148Coolant for radiator of DG sets of any capacity.complete all as specified and as directed.
149M&L for fan belt of any size suitable for DG sets of any capacity.complete all as specified and as directed.
150Dimantling and fixining in replacement of MCCB160 Amps, 4 pole, 415 Volts, 50 Hz, 36 kAin existing panels / sheet metal enclosures complete all as specified.
151Dimantling and fixining in replacement of MCCB200 Amps, 4 pole, 415 Volts, 50 Hz, 36 kAin existing panels / sheet metal enclosures complete all as specified.
152Supply and wrapping Asbestos rope 8mm dia of superior quality to the silencer pipe and muffler of DG set of capacity 30 KVA to 62.5 KVA including binding with 2mm dia GI binding wire and provinding white cement/plaster of paris to the Asbestos rope for smooth finishing all as specified and directed.
153Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable)insulated, two or more core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts grade og following sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items). (a) 50 Sq mm cross sectional area, 3½ core.
154Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundations etc. or for shafts, well cess pits, manholes, pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing /trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified.
155Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified.
156Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified.
157Material and labour for river sand, washed and screened dry for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete as specified and directed.
158M&L laying well burnt old size bricks, sub calss "B" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all as specified.
159Dismantling of old rusted flexi glow sign board of any description from various installations of any size under AGE Charduar and M& L for glow sign board mounted on angle iron box of size 3.0Mx0.90Mx0.3M fabricated with MS flat angleof size 40x40x5mm by means of cutting or welding in shape covered with0.7mm thick aluminium sheet on back side and blue acrylic sheet 2mm thick sheet on front side in background and writing letter such as PUMP HOUSE/SUB STATIONNO, MILITARY ENGINEER SERVICES, GARRISON ENGINEER (N) TEZPUR with white acrylic sheet on blue background with suitable sizes of letters as directed by Engr-in- Charge including 4 Nos 1x20 watt LED light fitting and making electrical connections with copper multistranded PVC insulated wire of nominal dia 1.5 sqmm single core and fixing /grouting it at suitable height as directed at site by means of all welding /grouting in PCCand other materials such as angle iron/GI or MS pipe etc all as required at site and testing on completion of job. Note: The light inserted in glow sign board should be openable type,no fixed ribet or joint should be there for ease out of damaged fitting for replacement.complete all as specified and as directed.
160Dismantling of old rusted flexi glow sign board of any description from various installations of any size under AGE Charduar and M& L for glow sign board mounted on angle iron box of size 1.50Mx0.90Mx0.3M fabricated with MS flat angleof size 40x40x5mm by means of cutting or welding in shape covered with0.7mm thick aluminium sheet on back side and blue acrylic sheet 2mm thick sheet on front side in background and writing letter such as PUMP HOUSE/SUB STATIONNO, MILITARY ENGINEER SERVICES, GARRISON ENGINEER (N) TEZPUR with white acrylic sheet on blue background with suitable sizes of letters as directed by Engr-in- Charge including 4 Nos 1x20 watt LED light fitting and making electrical connections with copper multistranded PVC insulated wire of nominal dia 1.5 sqmm single core and fixing /grouting it at suitable height as directed at site by means of all welding /grouting in PCCand other materials such as angle iron/GI or MS pipe etc all as required at site and testing on completion of job. Note: The light inserted in glow sign board should be openable type,no fixed ribet or joint should be there.complete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail