Housing Urban and Rular Development Government Departments Closing in 0 days TDR #39969906

Tender For Construction Of Government Scheduled Tribes Hostel Building (100 Bedded Girls) At Tehsil - Marihan, Distt. - Mirzapur, (U.P.)

Issued by Government Departments · marihan, Uttar Pradesh
Tender Value
4.57 Crore
Estimated cost
Bid Submission
06 Oct 2023
0 days left
EMD
9.16 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
marihan → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Government Scheduled Tribes Hostel Building ( 100 Bedded Girls ) At Tehsil - Marihan, Distt. - Mirzapur, ( U.P. )

BOQ

Name of Work:-CONSTRUCTION OF GOVERNMENT SCHEDULED TRIBE\"S HOSTEL BUILDING (100 BEDDED GIRLS) AT TEHSIL - MARIHAN, DISTT. - MIRZAPUR, (U.P.)(44/GM-1/UPPCL/2023-24/E-TENDERDated-08.09.2023)
Sl. No. Item Description
1CONSTRUCTION OF GOVERNMENT SCHEDULED TRIBE\"S HOSTEL BUILDING (100 BEDDED GIRLS) AT TEHSIL - MARIHAN, DISTT. - MIRZAPUR, (U.P.)
2(Civil work)
3Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches.
4Filling of carted earth.
5Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.
6Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work.
7Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground.
8floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm
9(4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm.
10R.C.C. (M-20) work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.
11Ground floor
12First floor
13As in item no. 6 above but for Slab (Using 1:1.5:3 Mix concrete).
14Ground floor
15First floor
16As in item no. 6 above but for Beams (Using 1:1.5:3 Mix concrete).
17Ground floor
18First floor
19As in item no. 6 above but for column (Using 1:1.5:3 Mix concrete).
20Ground floor
21First floor
22As in item no. 6 above but for Footing (Using 1:1.5:3 Mix concrete).
23M-150 brick work in one cement & six coarse sand 2.25 F.M. mortar in foundation and plinth including supply of all materials labour, tools and plants etc. required for proper completion of the work.
24Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
25M-150 Brick work in super-structure above plinth level up to floor two level (up to two storeys) includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:4 cement & coarse sand)
26Ground floor
27First floor
28Same as in item no. 12 but in1:3 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
29Ground floor
30First floor
31Providing & laying \"brick Coba\" 120mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of
32coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick
33ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work.
34Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
35(a) 32 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
36(b) Add extra for Double leaf shutter
37Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.
38Hold fast for chaukhats of doors/windows.
39Door / windows & Staircase grill.
40Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
41Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class teak wood. 30 mm thick
42TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks.
43Fixing of Door, windows/ventilators chaukhats in position.
44(a) Door
45(b) Windows
46(c) Ventilator chaukhats
4715 mm plinth plaster (1 cement :4 coarse sand)
4812mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6 coarse sand.
49Ground floor
50First floor
5112 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand
52Ground floor
53First floor
5412 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 3 fine sand
55Making grooves 10 to 12mmwide x8mm deep in plaster of the walls or in ceiling vertically or horizontally as required
5625mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement.
57Providing and laying vitrified floor tiles Kajaria / KERRO Brand or equivalent brand in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. (size of tiles 600x600mm)
58Providing and laying vitrified floor tiles Kajaria / KERRO Brand or equivalent brand in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. (size of tiles 600x600mm)
59Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (Area of slab upto 0.50 sqm)
6025 mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)
61Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
62Supply & fixing 6 mm thick china white glazed tiles in flooring or in skirting or dado laid with 1 :3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials labours & tools etc, required for completion of the work. (size of tiles upto 200x 300 mm).
63Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement
64Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3, Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt, dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work.
65Same as item 30 above but on new wood surface.
66Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
67Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling)
68Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete.
69Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
70Providing and fixing Stainless Steel sliding door bolts ISI marked to required colour or shade with nuts and screws etc. complete :300x16 mm
71Providing and fixing stainless steel tower bolts (barrel type) with necessary screws etc. complete
72(a) 250 mm x 10mm
73(a) 200 mm x 10mm
74Providing and fixing stainless steel handles with screws etc. complete (a) 150 mm
75Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters. with ISI marked M.S. pressed butt hinges bright finished of required size. Second class teak wood
76Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
77Providing & laying of light cinder filling under floor of toilets & other sunken roofs.
78Providing and laying water proofing treatment in sunken portion of W.C., bathroom etc, by applying cement slurry mixed with water proofing cement compound consisting of applying :- (a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with water proofing cement compound @ 0.253 kg/Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
79Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete : 25 mm dia
80Providing and fixing ISI marked 25 mm thick shutters (for cupboard) conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws
81Making of drain along with apron (Size 150*150mm)
82Providing and Laying of Rubber moulded (Grey colour) Interlocking Concrete Block Pavements) having thickness 80 mm Including levelling and dressing of surface to required level and slope, spreading and moisting 30m thick local sand on bed, filling joints with local sand on bed, filing joints with local sand etc. for proper completion of the work as per drawings and Technical Specification Clause 1504.
83Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.
84Providing and fixing C.I. tee at the inlet and outlet of septic tank.
85Providing & fixing 75mm dia vent pipes.
86Providing & fixing of 75mm dia cast iron terminal guard.
87Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
88M.D. -10- Circular shape 500mm internal diameter
89M.D. -2.5- Circular shape 450mm internal diameter
90Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.
91With F.P.S. bricks
92Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
93M.D. -10- Circular shape 500mm internal diameter
94Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
95Drilling of 300mm dia bore hole manually.
96Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
97150 mm nominal size dia
98Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
99Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
100Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
101Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
102Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
103M.D. -10- Circular shape 500mm internal diameter
104Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks
105Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:Drain 300 wide average.Depth 45 cm
106ELECTRICAL WORK.
107Wiring point for light with 1.5 Sq. mm FR PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earth wire drawn inside. continuity wire, Modular type switch & ceiling rose/angle/ batten holder on 3mm thick phenolic laminated backelite sheet etc. complete in all respect. with Modular Box & Cover plate.
108Wiring point for two way light with 1.5 Sq. mm F.R. PVC insulated multistrand single core copper conductor cable in PVC conduit Pipe with 1.5 Sqmm FRLSH PVC insuleted multistrand copper conductor cable as earthwire drawn inside the conduit. Modular type switches & ceiling rose/angle /batten holder on 3mm thick phenolic laminated backelite sheet etc. complete in all respect. with Modular Box & Cover plate.
109Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 Sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earthwire drawn inside the conduit, Modular type switch & ceiling rose on 3 mm. thick backelite sheet etc. complete in all respect with Modular Box & Cover plate.
110Wiring point for plugwith 1.5 Sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earthwire drawn inside the conduit, Modular type switch & socket etc. complete in all respect with Modular Box & Cover plate.
111Supply & wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labourand T&P etc. required for proper completion of the work as directed by Engineer I/C.
112Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor.
113cable as earth contunity wire etc. complete in all respects.
114Supply and wiring of submain 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty ( 2 mm thick ) 32mm dia PVC conduitalong with two numbers 6 sqmm FRLSH PVC insulated multistranded copper conductor
115cable as earth contunity wire etc. complete in all respects.
116Supply and wiring of submain 4 number 16 sqmm . PVC insulated 1100 V grade single core copper conductor cable in 40mm dia PVC conduitalong with two numbers 10 sqmmsingle core PVC insulatedcopper conductor
117cable as earth contunity wire etc. complete in all respects.
118Supplyfixingand concealing of20mm dia. 2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work .
119Erection and testing of ceiling fan and regulator for room height upto 3.5 mts. including supply of 3mm thick G.I. Pipe 19mm dia duly painted, complete in all respects.
120Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
121Supply and fixing hexagonal/Round G.P. fan box of approved make made up of 1.0mm thick ISI Marked G.P. sheet spot weeldeed Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screewed fitted with 300mm round zink coted M.S Bar X 12mm & brand name should be embossed.Fixing with wiring conduit laid in the R.C.C roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.
122Supplyfixingofelectronic fan regulator(Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.
123Supply and Ceiling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS: 374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volt 50Hz, 1-ph AC the fan assemble should consist of down rod blades, shackle canopies etc and with double ball breaing system
124BEE 5 star rated-1200 mm sweep
125Supply & fixing of recess mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.(CAT: AAA)
126Supply & fixing of LED Tube Light witH Metal heavy duty Box type batten light fitting 2 x 22 watt suitable for upto 2X22W LED Polycarbonate tube light complete including tube etc on surface complete in all respects.(CAT: AAA)
127Supply & fixing of recess mounting round 15 to 18 watt LED Bulb. Holder complete.
128Supply & fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 160 Watt to 175 Watt and Confirming to IP66 protection having Company LOGO Engraved complete in all respect including Labour.(CAT: AAA)
129Supply and fixing of surface/flush mounting distribution boards with additional metal door withot MCB complete in all respects.
1306 Way TPN
1318 Way TPN
13212 Way TPN
133Supply and fixing of 6Amp to 32 Amp(10 KA) MCB in existing MCB, DB complete with connections as required.
134Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge.
13563 Amp. 4 Pole MCB (10 KA)
136Supply and fixing of power plug with 15A/250 V flush type modular switch and 5 Pin 15 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work.
137Supply and fixing sheet steel enclosure surface / flush mounting fitted with 20 Amp 2 Pin and earth metal clad scraping earth plug and socket complete in all respect as directed at the site by Engineer in charge
138Supply and fixing Single Pole MCBS Blanking Plate complete in all respects.
139Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I.
140pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.
141Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
142Supply and fixing of one number 8 SWG G.I wire in 15mm dia. G.I pipe for earthing laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site.
143Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the
144cable run shall be fixed on M.S. clamps etc. of suitable size.95 sqmm3.5 core
145Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire
14695 sqmm3.5 core
147Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
14895 sqmm
149S & F surface/Flush mounting 6ways VTPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge.(CAT A)
150S & F of 125 Amp 4P MCCB (25KA) Thermal Magnetic release.
151S & F of 63 Amp TP MCB (10KA) C Curve.
152S & F of 40 Amp TP MCB (10KA) C Curve.
153S & F 6 Amp. To 32 Amp. SPMCB (10KA) C Curve
154Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and
155adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used.
156All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports.
157The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.
158The minimum clearances between bus bars shall be as follows :
159Phase to phase - minimum 20mm
160Phase to neutral-minimum 15mm
161Main L.T. Panel
162Incoming :
163200 Amp. TPN-1 No.
164Outgoing :
165100 Amp. TPN-1 No., 63 Amp. TPN-3 No.
166Providing and Laying unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing , cuttingand making good the walls & floors as per requirement.
167150mm
168Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep.
169ENTERNAL SANITARY
170Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware / Hindware / Seabird / Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
171White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
172Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
173Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required.
174a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
175Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
176Semi rigid pipe
17732 mm dia
17840 mm dia
179Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
180Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required:
181Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
182Providing and fixing PTMT Bottle Trap for Wash basin and sink
183Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
184Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
185Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
186600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
187Providing and fixing unplasticised PVC connection pipe with brass unions
18845 cm length
18915 mm nominal bore
190Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
191a) 15 mm nominal bore
192Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms.
193a) 15 mm nominal bore
194Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931
195a) 15 mm nominal bore
196Providing and fixing C.P. brass shower rose with 15 or 20mm inlet
197100 mm diameter
198Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:
19915mm nominal bore
200Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
201110mm
202Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground)
203100 /90 mm dia
204Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.
205110 mm
206Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
207Bend 87.5 degree
208110 mm Bend
209Shoe (Plain)
210110 mm Shoe
211Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
212Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
213110 mm
214Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
215Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
216Concealed work including cutting chases and making good the walls etc.
21732mm dia nominal outer dia pipes
218Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
219Concealed work, including cutting chases and making good the walls etc.
22015mm dianominal bore
22120mm dianominal bore
22225mm dia nominal bore
22332mm dia nominal bore
224Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
225Internal work - Exposed on wall
22640mm dia nominal bore
227Providing and fixing gun metal gate valve with wheel of approved quality.
22825mm dia nominal bore
22932mm dia nominal bore
23040mm dia nominal bore
23180mm dia nominal bore
232Providing and fixing brass stop cock of approved quality.
233b) 20 mm nominal bore
234Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m.
235All kinds of soil
236Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm.
237Providing, laying and jointing glazed stoneware pipes grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.
238100mm diameter
239Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design
240100mm dia SW pipe
241Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.
242150 mm.dia. RCCPipes
243Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
244150 mm.dia. RCCPipes
245Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design
246150 x 100 mm size P type
247With Sewer bricks conforming to IS : 4885
248Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
249Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
250With FPS bricks of class designation 75
251(i) For Sewer Line
252Extra for depth for manholes:
253Size 90x80cm with FPS bricks class I).
254Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design
255With 20x20 mm square bar
256Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.
257a) 150mm dia P.V.C. pipe
258b) 100mm dia P.V.C. pipe
259Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince)
260P-Trap type Floor Trap 110 x 90mm
261Providing and fixingterminal guard.
262a) 110mm
263Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.
264110mm bend
26590 mm bend
266Coupler 110mm
26790mm
268Single tee with door 90x90x90 mm
269110x110x110 mm
270Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to15 mm nominal bore
271Providing and fixing clean out plug110 mm dia.
272Providing and fixing on wall face unplasticised-Rigid PVC pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.
273160mm dia Under floor
274Providing and fixing pvcInlet fitting with 2 inlets 80 mm size fabricated from 110 mm dia PVC pipes(approx. length=150mm to 300mm) and fixed to PVC trap with joint and set in cement concrete as per standard drawingcomplete.
275Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks
276EXT W/S
277Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
278up to 1.50 m depth
279Pipes 80 mm to 300 mmdiameter
2801.50 m to 3.00 m depth
281Pipes 80 mm to 300 mmdiameter
282Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)
283Depth not exceeding 1.5 meter
284Depth 1.5 to3.00meter
285Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.
286150 mm.dia. RCCPipes
287250 mm.dia. RCCPipes
288Providing and laying cement concrete 1:5:10(1cement:5coarse sand :10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
289150 mm. dia.
290250 mm. dia.
291Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
292Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg andweight of frame 100 kg) :
293With common burnt clay FPS (non modular) bricks of class designation 75
294(i) For Sewer Line
295Extra for depth for manholes:
296Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
297Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
298Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge. (external work)
29980mm nominal bore.
30065mm nominal bore.
301Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.
30280mm nominal bore.
30365mm nominal bore.
304Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
305With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
306BORING
307Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.All Types of Soil 300 MM DIA
308Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.Rocky strata including Boulders 350 mm dia
309Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia having minimum wall thickness 5.00 mm
310Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia
311Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Around Pipe (3.14*0.10*0.10*120.00)
312Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
313Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \"V\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge..
314Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 150 mm dia
315Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm dia
316Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 150 mm dia
317Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 80 mm dia nominal bore
318Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
31932 mm nominal dia Pipes
32025 mm nominal dia Pipes
321Supply and fixing of Armoured cable ISI marked (25 sqmm 3.5 core)
322Supplying & installation of pumping motor pumpset ISI marked, making connection suitable for tube-well/D.C.B. The job includes screwing and welding of flanges on G.I. riser pipes (50 mm dia minimum) installation, complete fittings accessories with riser pipes jointing of electrical cables other connections making switch board electrical connections, all labour for testing of pumpset and supply of water to water mains complete in all respects.
323FIRE FIGHTING
324Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
325100 mm
326Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
327100 mm
328Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
329Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required.
330Note: The Pipes of sizes 150mm & below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
331100 mm
33280 mm
33325 mm
334Supplying & fixing single headed internal yard hydrant valve with instantaneousGunmetal/Stainless Steel coupling of63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal
335Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
3364 way - 150 mm dia M.S. Pipe
337Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
33840 m
339Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
340Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal
341Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. Gun Metal
342Supplying, Installation, Testing & Commissioning ofElectric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required:
343(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal confirming to IS 1520.
344(b) Suitable HP Squirrel cage indution motor, TEFC type synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, confirming to IS-325.
345(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
346(d) Suitable cement concrete foundation duly plastered with anti vibration pads.
347900 lpm at 35 m Head
348Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
349Providing, laying, testing & commissioning of \"B\" class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
35032mm nominal bore.
351Surface dressing of road with Painting between using 2.25 kg. of bitumen per sq.mt with 1.65 cum of stone chipping ,13.2 mm nominal size/100 sq.mt of road surface including corolidation .(Although this job the fore will be given to civil contractor /Required Tank and pump house as per direction of Fire Department)
352Supplying Installation testing & Commissioning of 25 mm Ball valve PN -1 gunmental as perIS:778 includingnecessary accessories and connections.Make : Standard Make
353Providing/Fixing of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted “FIRE” in red luminous paint. The size of the box should be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete.Make : Standard Make
354Providing/Fixing of cubical type floor mounted Fire pump control panel fabricated from 16 G M.S. sheet duly powder coated finish of approved shade and comprisingof :a) One 63 amp. TP+NL M.C.C.B with rotary handle of beacking capacity 35 KA.b)One Volt meter (0-500 V) with selector switch.c) One set including lamps.Make : Standard Make
355Supplying and laying of Insulated PVC sheathed ,Steel Aromed ,Copper Aluminum Conductor, 1100V grade Powder Cable . The cable shall be laid in tray /in trenches/on wall /floor etc. As required (Approx quantities only). Make : RR Kabel / Policab / Finolex
3562 crore x 1.5 sq.mm Cu Cable
3573.5 crore x 25 sq.mm AL Cable
358Supplying and fixing of Self Glow Exit signage for stairs and exits size 100 x 300.
359Fire man axe.Make: Firetol / Swastik / Innovative
360Supply & fixing of fire extinguishers, CO2 type 6.50 Kg capacity (ISI marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
361Supply & fixing of fire extinguishers, ABC type 6.00 Kg capacity (ISI marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
362G.S.T. Extra as per Applicable

AI Tender Summary

OUR REF NO 39969906
AUTHORITY Government Departments
TENDER VALUE 4.57 Crore
LAST DATE 06-10-2023
Authority
Authority Name Uttar Pradesh Projects Corporation Limited
Work Description Construction Of Government Scheduled Tribes Hostel Building ( 100 Bedded Girls ) At Tehsil - Marihan, Distt. - Mirzapur, ( U.P. )
Basic Detail
Tender No 44/UPPCL/GM-1/E-TENDER/2023-24 Dated-08.09.2023
Bidding Type Tender
Location
City marihan
State Uttar Pradesh
Key Dates
Publish Date 30 Sep 2023
Submission Date 06 Oct 2023
Open Date 06 Oct 2023
Finance
Tender Value 4.57 Crore
Tender Fee 17700
EMD 9.16 Lakhs
Exemption Not Available
Document List
68dbc9bb-7e05-405a-a5a7-c1de2188e1b5.html
BIDDOC44.pdf
BOQ_1418595.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 06, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 06, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

68dbc9bb-7e05-405a-a5a7-c1de2188e1b5.html

pdf

BIDDOC44.pdf

xls

BOQ_1418595.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender