Tender For Erection (Work Contract) Items For Thdc Works Singrauli (M.P.), singrauli-Madhya Pradesh

Uttar Pradesh Rajkiya Nirman Nigam Limited has published Tender For Erection (Work Contract) Items For Thdc Works Singrauli (M.P.). Submission Date for this Tender is 09-10-2023. Hand Glove Tenders in singrauli Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39965694
Tender For Erection (Work Contract) Items For Thdc Works Singrauli (M.P.)
Open Tender
Indian
Madhya Pradesh
singrauli
09-10-2023

Tender Details

Erection ( Work Contract ) Items For Thdc Works Singrauli ( M.P. ) -2 H- Beam 13 Meter 152 X 152 Mm 37.1 Kg / Meter 3 33 Kv V Cross Arm 1.5 Mtr ( 5Ft ) - Centre Made From 75X75x6mm Angle 4 Back Clamp For H Beam Pole Of 65X8mm Ms Flat 5 33 Kv Top Clamps 75X75x6mm Angle Type 6 Earthing Coil Of 115 Turns Of 50 Mm.Dia And 2.5 Mtr Lead Of 4.0 Mm G.I Wire 7 33 Kv, 10 Kn Pin Composite Polymer Insulator 8 Aaac Dog Conductor 0.10 Sq. Inch ( 100 Sq.Mm. Al.Eq. ) 9 Jointing Sleeves ( Aluminium ) For Dog Conductor 10 Stay Set 20 Mm Complete 11 H.Beam Clamps 65X8mm Flat 12 Concreting ( 1:3:6 ) Of H-Beam @ 0.65 Cmt.Per Pole ( Base Pedding + Muffing ) 13 Concreting ( 1:3:6 ) Of Stay @ 0.3 Cmt. Per Stay ( 20Mm ) 14 Red-Oxide Paint 15 Aluminum Paint 16 Anti Climbing Device ( Barbed Wire 3.5 Kg ) Gs 2.5 Mm Dia ( 12 Swg ) 17 Danger Board Enameled 33 Kv 18 Dc.Cross Arms 8` ( 2.4 Meter ) Centre To Centre 100X50x6 Mm Channel 19 33 Kv , 45 Kn Disc Polymer Long Rod Type T&C Insulator 20 Bracing Set For 8 Feet ( 2.45 Mtr ) Centre Dp Angle 21 Bracing Set For 5 Feet ( 1.5 Mtr ) Centre Dp Angle 22 33 Kv Suspension Clamps With Attachment For A.B Cable 23 33 Kv Tension Clamps ( Dead End ) With Attachment For A.B Cable 24 33 Kv Arial Bunch Cable 95 Sqmm 25 Cable Straight Through Joint Kits Suitable For 95 Sq.Mm. 26 Cable End Termination Kits Suitable For 95 Sqmm 27 Xlpe Cable 33 Kv Armoured 3X300 Sqmm 28 Outdoor / Indoor End Termination Kit ( 3X300 Sqmm For 2 Way Rmu ) 29 33 Kv Bridling Cross Arms 75X75x6mm 30 33 Kv Guarding Channel 75X40x6 Mm 31 Fixing Of 25 Mtr High Mast Shaft Of Approved Make With Rising System Hot Dip Glavanized Inside & Out Side Dip, Heaving Pole Sheet Thickness 4 Mm. Top Dia Minium 150 Mm, Bottom Dia 460 Mm Base Plate 32 Mm Thick Suitable For Wind Velocity As Per Is 875 Part 3 & Having No Circumferential Weld, With Accessories For High Mast Such As Head Frame Suitable For 8 To 14 Luminaries & Its Control Gear Boxes 1.5 Hp Power Tool Moter, 3 Point Suspension System With Steel Wire Rope 8 Mm Dia, Double Drum Winch, Including Making Suitable Foundation As Per Manufature Drawing / Site Reuiment Along With 08 Nos Foundation Bolts Nuts, Washers, Anchor Plates Etc Complete In All Respect ( Including Erection Cost ) . 32 Itc Of Outdoor Type Feeder Pillar ( Powder Coated Metal Sheet Outer Door Thickness - 2Mm, Inner Door Thicness- 1.6 Mm, Each Door Shall Be Provided With 2 Numbers Industrial Locks ) , For Service Connection In Underground Lt Line Incoming Al. Ec Grade Bus-Bar For Lilo 300 Amp. 30X10 Mm. Mccb: 1 No.-125 Amp, 18 Ka B.C At 415 Volts Tp Mccb With Copper Neutral Link, Busbar:1 Set-200 Amp , Aluminium Busbar, Outgoing Mccb Current Rating: 32 Amp, 10 Ka B.C., , 30 Nos. Spn . Is 5039, Is 13947, Iec 65029, Is 2147 And Relevant Is Standards 33 Fixing Of 350 Watt Flood Light ( Long Range ) 34 Fixing Of 350 Watt Flood Light ( Wide Spread ) 35 Fixing Of 4C X 25 Sqmm Aluminium Armoured Cable Xlpe Insulated 36 Laying Of One Number Armoured / Unarmoured Power Cable 1.1Kv Grade Of Size Not Exceeding 25 Sq. Mm Direct In Ground Including Excavation In All Soil / Murrum / Soft Rock, Sand Cushioning, Protective Covering And Refilling The Pit Etc. As Required 37 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1Kv Grade As Required. ( 4C X 25 Sqmm ) 28 Mm 38 Fixing Of Mccb 100 Amp ( 4 Pole ) With Frame Complete 39 Fixing Of 5 Core X 6 Sq.Mm Trailing Copper Cable 40 Fixing Of Xlpe Insulated Frls Heavy Duty Power Cable Conforming Is-7098 ( Part-1 ) 1988, 1100 Volt Grade, 4 Core 2.5 Sq. Mm Isi Marked With Copper Stranded / Solid Conductor. 41 Fixing Of Xlpe Insulated Frls Heavy Duty Power Cable Conforming Is-7098 ( Part-1 ) 1988, 1100 Volt Grade, 2 Core 2.5 Sq. Mm Core Isi Marked With Copper Stranded / Solid Conductor. 42 Earthing With G.I. Earth Plate 600Mmx600mmx3mm Thick Including Accessories And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Mt. Long Etc With Charcoal / Coke And Salt As Required. 43 Sub-Station - Installation, Testing & Commissioning Of Out Door Type 10 Mva Power Transformer Oftc With On Load Tap Changer Is 2026, Iec296, And Any Other Relevant Is Including Loading, Unloading, Local Carriage & Erection Of The Same On Plinth & Making All Necessary Connection Etc. Complete In All Respects As Per Specification. Cable Termination Box With Disconnecting Facility For 33 Kv Xlpe Cable At 33 Kv Side. Cable Termination Box With Disconnecting Facility For 11 Kv Xlpe Cable At 11 Kv Side. On Load Tap Changer+ / - 7.5@2.5%, Bi Directional Roller, Conservator With Drain Valve, Earthing Ferminals, Double Diaphragm Explosion Vent, Radiator With Top & Bottom Shut Off Valve, First Filling Of Oil Including Make Up Fill, Silica Gel Breather With Oil Seal, Rating And Diagram Plate, Air Release Plug, Buchholz Relay With Shut Off Valve, Winding Temperature Indicator ( Wti ) , Oil Temperature Indicator ( Oti ) , Megenatic Oil Level Guage, Pressure Relief Device, Marshalling Box. No Load Losses-8Kw, Load Losses 50Kw, Toleronce As Per I.S. Code 44 Installation, Testing & Commissioning Of 33Kv Vcb Panel 1250Amp , Copper Bus-Bar , Inbuild C.T & P.T, Protection Relays , Digital Instruments Like Ameter , Voltmeter Etc. Incomer -02Nos Bus Coupler - 01 No Outgoing - 02 Nos 45 Installation, Testing & Commissioning Of 11Kv Vcb Panel 1250Amp , Copper Bus-Bar , Inbuild C.T & P.T, Protection Relays , Digital Instruments Like Ameter , Voltmeter Etc. Incomer -02Nos Bus Coupler - 01 No Outgoing - 08 Nos 46 Laying Of One Number Xlpe Power Cable Of 33 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. 47 Upto 120 Sq. Mm 48 Supplying And Making Indoor Cable End Termination With Heat Shrinkable Jointing Kit Complete With All Accessories Including Lugs Suitable For Following Size Of 3 Core, Xlpe Aluminium Conductor Cable Of 33 Kv Grade As Required: 49 120 Sq. Mm 50 Supplying And Making Outdoor Cable End Termination With Heat Shrinkable Jointing Kit Complete With All Accessories Including Lugs Suitable For Following Size Of 3 Core, Xlpe Aluminium Conductor Cable Of 33 Kv Grade As Required: 51 120 Sq. Mm 52 Laying Of One Number Pvc Insulated And Pvc Sheathed I Xlpe Power Cable Of 11 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refillinq The Trench Etc As Required. 53 Above 120 Sq. Mm And Upto 400 Sq. Mm 54 Supplying And Making Indoor Cable End Termination With Heat Shrinkable Jointing Kit Complete With All Accessories Including Lugs Suitable For Following Size Of 3 Core, Xlpe Aluminium Conductor Cable Of 11 Kv Grade As Required: 55 300 Sq. Mm 56 Supplying And Making Outdoor Cable End Termination With Heat Shrinkable Jointing Kit Complete With All Accessories Including Lugs Suitable For Following Size Of 3 Core, Xlpe Aluminium Conductor Cable Of 11 Kv Grade As Required: 57 300 Sq. Mm 58 Providing, Laying And Fixing Following Dia Rcc Pipe Np2 Class ( Light Duty ) In Ground Complete With Rcc Collars, Jointing With Cement Mortar 1 :2 ( 1 Cement : 2 Fine Sand ) Including Trenching ( 75 Cm Deep ) And Refillinq Etc As Required. 59 300 Mm Dia 60 Laying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm. Thick Sand All Around And Protected With Burnt Bricks On Sides And On Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc 61 50 Sq. Mm 3-1 / 2 Core 62 150 Sq. Mm 3-1 / 2 Core 63 Supplying And Making Outdoor End Termination With Cast Resin Compound Including Aluminium Lugs And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed I Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 64 31 / 2X50sq. Mm 65 31 / 2X150sq. Mm 66 Erection, Testing And Commissioning Of 48 V Dc, 200 Ah, Vrla Battery Consisting 24 No Cell Of 2 Volt Each. Including Battery Charging Arrangement With All Ac / Dc Ameter And Voltmeter Meters. 67 Erection, Testing And Commissioning Of Direct Curent Distribution Board ( Dcdb ) 24 Volts Indoor Floor / Wall Mounted Comprising Of 1 No. 2P / 100A Dc Mccb 5A Switch Fuse Unit As Incommer And 8 No. 2P / 40A Mccb 5A Switch Fuse Units For Each Individual Outgoing Circuit Of Indoor Control Panels, Indoor / Outdoor Vcb Panels, 1 No. 2P / 40A Mccb 5A Switch For Control Room Emergency Dc Lighting Including 20% As Spare. Each Incoming & Outgoing Shall Have Indicating Lamp, 68 Erection, Testing And Commissioning Of Acdb 415 V, Along With Three Phase-Neutral Voltmeter, Three Phase Ammeter And Selector Switches, 1No. 200 Amps Tpn Switch Fuse Unit As Incomer, 1No. 63 Amp. Tpn Mccb Switches As Outgoing Feeders & 2No. 32 Amp. Mccb As Outgoing For Yard And Control Room Lightining And 6 No. 16 No. Mccb For Control Panels, Each Incoming & Outgoing Shall Have Indicating Lamp. Including 20% Spare 69 Installation, Testing & Commissioning Of Lattice Structure 70 Fixing Of 33 Kv, Isolator 800 Amp. ( Turn And Twist Type ) 71 Equipments -Installation, Testing & Commissioning Of Bis Certified Energy Efficiency Level-Iii ( Old ) / Level-Ii ( New ) Convential 11 / 0.433Kv, 100 Kva Distribution Transformer 72 Installation, Testing & Commissioning Of Marshelling Box With 10 No. Connectors 73 Erection, Testing And Commissioning Of Lt Distribution Box With 1.2 Mm Thick Ms Powder Coated Sheet, 200 A Mcb On Incoming & 6 No. 125 A Hrc Fuse Base Including 100 A Hrc Fuse , For 100 Kva Transformer Made Of Smc 74 Fixing Of Transformer Mounting Channel ( 100X50x6mm ) 75 Fixing Of Copper Control Cable 2 Core. 2.5 Sq.Mm. ( Unarmoured ) 76 Fixing Of Copper Control Cable 4 Core. 2.5 Sq.Mm. ( Unarmoured ) 77 Fixing Of Copper Control Cable 8 Core. 2.5 Sq.Mm. ( Unarmoured ) 78 Fixing Of Copper Control Cable 12 Core. 2.5 Sq.Mm. ( Unarmoured ) 79 Fixing Of Bi Metallic Clamp For Power Transformer Of Brass Flat 50X50x10mm 80 For Gantry Structure ( 33Kv ) -Installation, Testing & Commissioning Of H-Beams 152 X 152 Mm., 37.1 Kg. / Mtr 13 Mtr. Long = 482.3 Kgx 81 Installation, Testing & Commissioning Of D.C. Channel 4.8 Mtr. Centre 100X50x6mm For 33Kv Gantry Structure ( Each Weight- 99.90 Kg ) 82 Installation, Testing & Commissioning Of Back Clamp Suitable For H-Beam ( Ms Flat 65X8 Mm ) - Each Weight 1.92 Kg 83 Installation, Testing & Commissioning Of 33 Kv Top Clamps 75X75x6 Mm Angle ( Each Weight 3.58 Kg ) 84 Installation, Testing & Commissioning Of Earthing Coil ( Coil Of 115 Turns Of 50 Mm.Dia. And 2.5 Mtrs. Lead Of 4.0 Mm. G.I Wire ) 85 Installation, Testing & Commissioning Of Aaac Dog Conductor 0.10 Sq. Inch ( 100 Sq.Mm. Al.Eq. ) 86 Suppy And Erection Of Single Piece Nonlinear Resistor Type Lightning Arrestor Suitable For3wire 33Kv Overhead Lines With Rated Voltage 30Kv ( Rms ) With A Nominal Discharge Current Rating Of 10Ka ( Station Class ) And Complete With Galvanized Clamping Arrangement , G.I Bolts , Nuts, Washers Etc. As Required. 87 Suppy And Erection Of 33Kv Pin Insulator Complete With Large Steel Head G.I. Pin , Nuts, Washers Etc As Required. 88 Stone Block / Pre Cast Block For Base Pedding 450X450x75 Mm 89 Concreting ( 1:3:6 ) 0.36 Cmt For [ H-Beam - 7 M, 9 M & Rsj 9.3 M, Pcc Pole Dp / Tp / 4P / 6P Of 140 Kg. 8 M 200 Kg. 9 M 280 Kg. 9 M ] , 0.56 Cmt For 11 M, 0.60 Cmt For 13 M, 0.67 Cmt For 15 M Per Pole Including Muffing With Pole Pit Digging By Hydra M / C. 90 Clamp Suitable For 152 X 152 Mm., 37.1 Kg. / Mtr 13 Mtr. Long H-Beam ( Each Weight 3.2 Kg ) 91 11Kv Outgoing Lines ( 06 Nos Bays ) -Installation, Testing & Commissioning Of 200 Kg., 9.0 Mtrs. Long Pcc Poles 92 Installation, Testing & Commissioning Of D.C. Channel 4.8 Mtr Centre 100X50x6mm For 11Kv ( Each Weight-99.90 Kg ) 93 Installation, Testing & Commissioning Of Back Clamp Suitable For 280 Kg Pcc Pole ( Ms Flat 65X8 Mm ) - Each Wt 1.92 Kg 94 Installation, Testing & Commissioning Of 11 Kv Top Clamps Angle Type 65X65x6 Mm 95 Suppy And Erection Of Three Piece Nonlinear Resistor Type Lightning Arrestor Suitable For 3Wire 11Kv Overhead Lines With Rated Voltage 9Kv ( Rms ) With A Nominal Discharge Current Rating Of 5Ka ( Station Class ) And Complete With Galvanized Clamping Arrangement , G.I Bolts , Nuts, Washers Etc. As Required. 96 Suppy And Erection Of 11Kv Pin Insulator Complete With Large Steel Head G.I. Pin , Nuts, Washers Etc As Required. 97 Installation, Testing & Commissioning Of Mesh Earthing For New 33 / 11Kv Sub-Station Inblack Cotton Soil As Per Schedule G-3.1 98 Installation, Testing & Commissioning 1500 Kvar Auto Switch, 11 Kv Capacitor Bank Complete With Individual Fuses , Interconnection , Mounting Racks, External Fuses, Mounting Arrangement, Bas Insulator And Accessories With Earthing And Marshelling Box 99 Installation, Testing & Commissioning Of Earthing Of Capacitor Bank As Per Schedule G-6.1 ( For Black Cotton Soil ) 100 Installation, Testing & Commissioning Of Earthing With Copper Earth Plate 600Mmx600mmx3mm Thick Including Accessories And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Mt. Long Etc With Charcoal / Coke And Salt As Required. 101 Laying Of 32Mm X 6Mm Copper Strip From Earth Electrode Directly In The Ground As Required Complete In All Respect. 102 Miscellaneous Items- ( I ) -Safety Helmets 103 ( Ii ) - Tong Tester Digital ( 1000A, 500V ) With Associates Accessory 104 ( Iii ) - Chain Pully Block 3Ton With 15 Metre Chain. 105 ( Iv ) - Wall Mounting Type Holder For Hydrometer 106 Megger Anolog 1000 V 107 Megger Anolog 5000 V. 108 ( Vii ) - Battery Hydrometer 109 ( Viii ) - Rubber Hand Gloves For 15Kv ( Seamless ) 110 ( Ix ) - Transformer Oil Dielectric Breakdown Test Kit 111 Fixing Of Fire Bucket, Round Bottom Made Of G.I. Sheet 9-11 Litres Capacity Duly Painted As Per Fire Brigade Design, Supported On Hanging Bracket Chained And Locked, Initially Filled With Fine River Sand, Water As Per Directions Of Engineer-In-Charge. 112 Fixing Of Shock Treatment Chart ( Prescribed Under I.E. Rules ) Duly Framed With Glass And Supported From Back With Hard Board Or Soft Board With Supply Of All Material Labour T&P For Proper Completion Of Work 113 Fixing Of Fire Extinguisher, Abc Type 9.00 Kg. Capacity ( Isi Marked Is : 15683 & Tac Approved ) Complete With Initial Charge And Wall Bracket, Along With Supply Of All Materials And Labour For Proper Completion Of Work. 114 Fixing Of C02 Type Fire Extinguisher 6.5 Kg. Capacity ( Isi Marked Is : 2878 & Tac Approved ) Complete With Initial Charge And Wall Bracket, Along With Supply Of All Materials And Labour For Proper Completion Of Work. 115 Laying Of 11Kv 1800Mm X 900Mm X 12Mm Thick Chequered Rubbbber Matting Of Tested Quality. 116 Earth Resistance Tester ( 20 / 200 / 2000Ohms ) Digital 117 Filter Machine 250Gph ( Transformer Oil Filtration Purpose ) 118 Fixing Following Capacity Of Automatic Street Light Cubicle Control Panel Painted With Anti Corrosive Alkali And Acid Proof Paint Consisting Of Time Switch Tso 100 Series With Contactors, Hrc Fuses, Isolating Switch Metering Instrument & Instrument Box With Cts Etc. In Case Of Tpn, Complete In All Respect. Auto / Mannual Selector Switch 24 Hour Programmable Timer. 40A Tpn 119 Fixing Of Mccb ) Suitable For 3 Phase & N, 4 Pole, Ac Supply With Micro Processor Release ( Mccb, 25Ka, 40 & 100 Amps, 4P ) 120 Fixing Of Steel Enclosure, Neutral Bar Suitable For Mcb / Rcbos / Mccb ( 63A / 100A, 3P / 4P Enclosure ) 121 Laying Of 4 X 10Sq.Mm Aluminium Cable A2xfy Type. 122 Cables & Wirings - Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface I Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required 123 Group C 124 Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface I Recessed Steel Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc .As Required. 125 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 126 Wiring For Light / Power Plug With 4X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 2 Nos. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 127 Wiring For Circuiv Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 128 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 129 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 130 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 131 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 132 4 X 10 Sq. Mm+ 2 X 6 Sq. Mm Earth Wire 133 Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 134 2 Pair 135 Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required 136 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 137 20 Mm 138 25 Mm 139 40 Mm 140 Supplying And Fixing Metal Box Of Following Sizes ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc. As Required. 141 75 Mm X 75 Mm X 60 Mm Deep 142 100Mmx100 Mm X 60 Mm Deep 143 150 Mm X 75 Mm X 60 Mm Deep 144 150Mmx150 Mm X 60 Mm Deep 145 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 146 5 / 6 A Switch 147 2 Way 5 / 6 A Switch 148 15 / 16 A Switch 149 3 Pin 5 / 6 A Socket Outlet 150 6 Pin 15 / 16 A Socket Outlet 151 Telephone Socket Outlet 152 Tv Antenna Socket Outlet 153 Bell Push 154 Supplying, Erection And Testing Of Approved Make Electric Ceiling Fan Of Double Ball Bearing Complete With Standard Down Rod, Canopy, Hanging Shackle, Aluminium Blades, Without Regulator, A.C. 230-250 Volts Including Connections With All Necessary Material Complete Of Approved As Required Confirming To Is :374 / 2019 With Upto Date Amendments. ( 1400 Mm Sweep ) 155 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 156 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 157 Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 V, Complete As Required. 158 Numbering Of Ceiling Fan / Exhaust Fan / Fluorescent Fittings As Required. 159 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required 160 Upto 450 Mm Sweep 161 Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required 162 2 Run Of Cable 163 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Lsolator ) 164 6 Way ( 4 + 18 ) , Double Door 165 8 Way ( 4 + 24 ) , Double Door 166 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioninq Etc. As Required 167 Single Pole 168 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 169 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioninq Etc. As Required. 170 63A 171 100A 172 Providing And Fixing H.T. Danger Notice Plate Of 250 Mm X 200 Mm, Made Of Mild Steel, At Least 2 Mm Thick, And Vitreous Enameled White On Both Sides, And With Inscription In Single Red Colour On Front Side As Required. 173 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. 174 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 175 200 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 176 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays Bends With Perforation Not More Than 17.5%, , Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Reauired. 177 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 178 200 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 179 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays Tee With Perforation Not More Than 17.5%, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Reauired 180 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 181 225 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 182 Supplying And Fixing Cable Route Marker With 10 Cm X 10 Cm X 5 Mm Thick G.I. Plate With Inscription There On, Bolted / Welded To 35 Mm X 35 Mm X 6 Mm Angle Iron, 60 Cm Long And Fixing The Same In Ground As Required. 183 Fixing Of 7 Mtr Gi Octagonal Pole Of Approved Make ( Top Dia 70Mm, Bottom Dia 130Mm And Base Plate 12Mm Thik ) Having 3Mm Thikness With Single Arm Bracket ( 1 Mtr Length ) On Rcc Foundation Including The Cost Of Foundation, Foundation Bolts, Excavation & Back Filling And Required T&P Completee In All Respect 184 Fixing Of Led Street Light Fitting Having Die Cast Aluminium Body And Diffuser With Driver Set Suitable For 140 To 150 Watt. Confirming To Ip 66 Protection Complete In All Respects Cat- Aaa 185 Surface Dressing Of The Ground Including Removing Vegetation And Inequalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M. All Kinds Of Soil 186 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil 187 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 188 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete 189 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) 190 Diluting And Injecting Chemical Emulsion For Post- Constructional Anti-Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) :Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 ( 1 Cement : 2 Coarse Sand ) To Match The Existing Floor: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration 191 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . & Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform 192 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . & Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform 193 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . & Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform 194 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 195 Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 196 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 197 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Suspended Floors, Roofs, Landings, Balconies And Access Platform 198 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 199 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Columns, Pillars, Piers, Butments, Posts And Struts 200 Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In:Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) . 201 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 202 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 203 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. 204 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws 205 Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 30X10x15cm 1:3:6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size 206 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Steel Windows By Welding 207 Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side / Top / Centre Hung, With Beading And All Members Such As F7d, F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, ( Sectional Weight Of Only Steel Members Shall Be Measured For Payment ) . Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 208 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) . 209 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Mild Steel And Medium Tensile Steel Bars 210 Fixing Of Steel Or Wooden Chaukhats In Position. 211 ( A ) Door Chaukhats 212 ( B ) Window Chaukhats 213 ( B ) Ventilator Chaukhats 214 15 Mm Cement Plaster On Plinth Side Of Single Or Half Brick Wall Of Mix : 1:4 ( 1 Cement: 4 Coarse Sand ) 215 12 Mm Cement Plaster Of Mix :1:6 ( 1 Cement: 6 Coarse Sand ) 216 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix : ( 1 Cement: 6 Coarse Sand ) 217 Forming Groove Of Uniform Size From 12X12 Mm And Upto 25X15 Mm In The Top Layer Of Washed Stone Grit Plastered Surface As Per Approved Pattern, Including Providing And Fixing Aluminum Channels Of Appropriate Size And Thickness ( Not Less Than 2 Mm ) , Nailed To The Under Layer With Rust Proof Screws And Nails And Finishing The Groove Complete As Per Specifications And Direction Of The Engineer-In-Charge. 218 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 219 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 220 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete Size Of Tile 600X600 Mm 221 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete Size Of Tile 600X600 Mm 222 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications :Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr / 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr / 10 Sqm Of Approved Brand And Manufacture 223 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications :Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr / 10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr / 10 Sqm Of Approved Brand And Manufacture 224 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade : New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) 225 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer 226 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer 227 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete 228 Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 229 Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) , Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete :250X16 Mm 230 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete :300X10 Mm 231 Providing And Fixing Aluminium Handles, Isimarked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screw Setc. Complete :100 Mm 232 Providing And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations: ( A ) Applying A Slurry Coat Of Neat Cement Using 2.75 Kg / Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is. 2645 And Approved By Engineer-In-Charge Over The Rcc Slab Including Adjoining Walls Upto 300 Mm Height Including Cleaning The Surface Before Treatment. ( B ) Laying Brick Bats With Mortar Using Broken Bricks / Brick Bats 25 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 ( 1 Cement : 5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 ( 1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs. 233 ( C ) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg / Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge. ( D ) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 ( 1 Cement :4 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. 234 ( E ) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.“All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm. 235 Providing And Fixing Double Glazed Hermetically Sealed Glazing In Aluminium Windows, Ventilators And Partition Etc. With 6 Mm Thick Clear Float Glass Both Side, Having 12 Mm Air Gap, Including Providing Epdm Gasket, Perforated Aluminium Spacers, Desiccants, Sealant ( Both Primary And Secondary Sealant ) Etc. As Per Specifications, Drawings And Direction Of Engineer-In-Charge Complete. 236 Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Is: 4454 - Part 1 And M.S. Top Cover Of Required Thickness For Rolling Shutters.80X1.25 Mm M.S. Laths With 1.25 Mm Thick Top Cover 237 Providing And Fixing Ball Bearing For Rolling Shutters. 238 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes.110 Mm Diameter 239 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. 110 Mm Bend 240 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 110 Mm

Key Value

Document Fees
INR 23600 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: ERECTION (WORK CONTRACT) ITEMS FOR THDC WORKS SINGRAULI (M.P.)
Sl. No. Item Description
1ERECTION
2H- BEAM 13 METER 152 X 152 MM 37.1 KG/METER
333 KV "V" CROSS ARM 1.5 MTR (5FT)- CENTRE MADE FROM 75X75X6MM ANGLE
4BACK CLAMP FOR H BEAM POLE OF 65X8MM MS FLAT
533 KV TOP CLAMPS 75X75X6MM ANGLE TYPE
6EARTHING COIL OF 115 TURNS OF 50 MM.DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE
733 KV,10 KN PIN COMPOSITE POLYMER INSULATOR
8AAAC DOG CONDUCTOR 0.10 SQ. INCH (100 SQ.MM. AL.EQ.)
9JOINTING SLEEVES (ALUMINIUM) FOR DOG CONDUCTOR
10STAY SET 20 MM COMPLETE
11H.BEAM CLAMPS 65X8MM FLAT
12CONCRETING (1:3:6) OF H-BEAM @ 0.65 CMT.PER POLE (BASE PEDDING + MUFFING)
13CONCRETING (1:3:6) OF STAY @ 0.3 CMT. PER STAY (20MM)
14RED-OXIDE PAINT
15ALUMINUM PAINT
16ANTI CLIMBING DEVICE (BARBED WIRE 3.5 KG) GS 2.5 MM DIA (12 SWG)
17DANGER BOARD ENAMELED 33 KV
18DC.CROSS ARMS 8` (2.4 METER ) CENTRE TO CENTRE 100X50X6 MM CHANNEL
1933 KV , 45 KN DISC POLYMER LONG ROD TYPE T&C INSULATOR
20BRACING SET FOR 8 FEET (2.45 MTR ) CENTRE DP ANGLE
21BRACING SET FOR 5 FEET (1.5 MTR ) CENTRE DP ANGLE
2233 KV SUSPENSION CLAMPS WITH ATTACHMENT FOR A.B CABLE
2333 KV TENSION CLAMPS (DEAD END) WITH ATTACHMENT FOR A.B CABLE
2433 KV ARIAL BUNCH CABLE 95 SQMM
25CABLE STRAIGHT THROUGH JOINT KITS SUITABLE FOR 95 SQ.MM.
26CABLE END TERMINATION KITS SUITABLE FOR 95 SQMM
27XLPE CABLE 33 KV ARMOURED 3X300 SQMM
28OUTDOOR/INDOOR END TERMINATION KIT (3X300 SQMM FOR 2 WAY RMU)
2933 KV BRIDLING CROSS ARMS 75X75X6MM
3033 KV GUARDING CHANNEL 75X40X6 MM
31fixing of 25 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 4 mm. Top dia minium 150 mm, Bottom dia 460 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 8 to 14 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with 08 nos foundation bolts nuts, washers, anchor plates etc complete in all respect(Including Erection cost).
32ITC OF Outdoor type feeder pillar (Powder coated Metal Sheet outer door thickness - 2mm, inner door thicness- 1.6 mm, Each door shall be provided with 2 numbers industrial locks), for service connection in underground LT line Incoming Al. EC grade bus-bar for LILO 300 Amp. 30x10 mm. MCCB: 1 no.-125 amp, 18 kA b.c at 415 Volts TP MCCB with copper neutral link, Busbar:1 set-200 amp , aluminium busbar, Outgoing MCCB Current Rating: 32 Amp,10 kA b.c., ,30 Nos. SPN .IS 5039, IS 13947, IEC 65029, IS 2147 and relevant IS standards
33fixing of 350 Watt Flood light (Long range)
34fixing of 350 Watt Flood light (wide spread)
35fixing of 4C X 25 Sqmm Aluminium Armoured Cable XLPE insulated
36Laying of one number armoured /unarmoured power cable 1.1KV grade of size not exceeding 25 sq. mm direct in ground including excavation in all soil/murrum /soft rock, sand cushioning,protective covering and refilling the pit etc. as required
37Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1KV grade as required. (4C X 25 Sqmm) 28 mm
38fixing of MCCB 100 amp(4 pole) with frame complete
39fixing of 5 core x 6 sq.mm trailing copper cable
40fixing of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 4 core 2.5 sq. mm ISI marked with copper stranded/solid conductor.
41fixing of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2 core 2.5 sq. mm core ISI marked with copper stranded/solid conductor.
42Earthing with G.I. earth plate 600mmX600mmX3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mt. long etc with charcoal /coke and salt as required.
43SUB-STATION - Installation, testing & commissioning of out door type 10 MVA Power Transformer OFTC with on load tap changer IS 2026,IEC296,and any other relevant IS including loading, unloading, local carriage & erection of the same on plinth & making all necessary connection etc. Complete in all respects as per specification. Cable termination box with disconnecting facility for 33 KV XLPE cable at 33 KV side. Cable termination box with disconnecting facility for 11 KV XLPE cable at 11 KV side.On load tap changer+/- 7.5@2.5%, Bi directional roller, Conservator with drain valve, Earthing ferminals, Double diaphragm explosion vent, Radiator with top & bottom shut off valve, First filling of oil including make up fill, Silica gel breather with oil seal, Rating and diagram plate, Air Release plug,Buchholz relay with shut off valve,Winding temperature indicator (WTI), Oil temperature indicator (OTI), Megenatic oil level guage, Pressure relief device, Marshalling box. No load losses-8Kw, load losses 50KW, Toleronce as per I.S. code
44Installation, testing & commissioning of 33KV VCB Panel 1250Amp , Copper bus-bar , Inbuild C.T & P.T,Protection relays , digital instruments like Ameter ,voltmeter etc. Incomer -02Nos Bus coupler - 01 No Outgoing - 02 Nos
45Installation, testing & commissioning of 11KV VCB Panel 1250Amp , Copper bus-bar , Inbuild C.T & P.T,Protection relays , digital instruments like Ameter ,voltmeter etc. Incomer -02Nos Bus coupler - 01 No Outgoing - 08 Nos
46Laying of one number XLPE power cable of 33 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
47Upto 120 sq. mm
48Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required:
49120 sq. mm
50Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required:
51120 sq. mm
52Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refillinQ the trench etc as required.
53Above 120 sq. mm and upto 400 sq. mm
54supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:
55300 sq. mm
56Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:
57300 sq. mm
58Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1 :2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refillinQ etc as reQuired.
59300 mm dia
60laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc
6150 sq. mm 3-1/2 core
62150 sq. mm 3-1/2 core
63Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed I XLPE aluminium conductor cable of 1.1 KV grade as required.
6431/2X50sq. mm
6531/2X150sq. mm
66Erection, testing and commissioning of 48 V DC, 200 AH, VRLA battery consisting 24 no cell of 2 volt each.Including battery charging arrangement with all AC/Dc ameterandvoltmeter meters.
67Erection, testing and commissioning of Direct Curent Distribution Board (DCDB) 24 Volts Indoor floor / wallmounted comprising of 1 no. 2P/100A DC MCCB 5A Switch Fuse Unit as incommer and 8 no. 2P/40A MCCB 5A switch fuse units for each individual outgoing circuit of indoor control panels, indoor/outdoor VCB panels, 1 no. 2P/40A MCCB 5A switch forcontrol room emergency DC lighting including 20% as spare. Each incoming & outgoing shall have indicating lamp,
68Erection, testing and commissioning of ACDB 415 V,along withthree phase-neutral voltmeter,three phase ammeter andSelector switches, 1no.200 Amps TPN switch fuse unit as incomer, 1no. 63 Amp.TPN MCCB switches as outgoing feeders & 2no. 32 Amp. MCCB as outgoingfor yard and control room lightining and 6 no. 16 no. MCCB for control panels, Each incoming & outgoing shall have indicating lamp. including 20% spare
69Installation, testing & commissioning of Lattice Structure
70fixing of 33 KV, ISOLATOR800 AMP.(Turn and twist type)
71EQUIPMENTS -Installation, testing & commissioning of BIS certified Energy Efficiency Level-III (Old)/Level-II (New) Convential 11/0.433KV, 100 KVA Distribution Transformer
72Installation, testing & commissioning of Marshelling box with 10 no. connectors
73Erection, testing and commissioning of LT distribution box with 1.2 mm thick MS powder coated sheet, 200 A MCB on incoming & 6 no. 125 A HRC fuse base including 100 A HRC fuse ,For 100 KVA Transformer made of SMC
74Fixing of Transformer mounting channel(100x50x6mm)
75Fixing of Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured)
76Fixing of Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured)
77Fixing of Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured)
78Fixing of Copper Control Cable 12 Core. 2.5 Sq.mm. (Unarmoured)
79Fixing of Bi Metallic Clamp for Power Transformer of Brass Flat 50x50x10MM
80FOR GANTRY STRUCTURE (33KV)-Installation, testing & commissioning of H-Beams 152 X 152 mm., 37.1 Kg./mtr 13 Mtr. Long= 482.3 kgx
81Installation, testing & commissioning of D.C. Channel4.8 Mtr.Centre100X50X6MMFOR33KVGantry structure(eachweight- 99.90 Kg)
82Installation, testing & commissioning of Back Clamp suitable for H-Beam (MS Flat 65x8 mm)-each weight 1.92 Kg
83Installation, testing & commissioning of 33 KV Top clamps 75x75x6 mm Angle ( each weight 3.58 Kg)
84Installation, testing & commissioning of Earthing Coil ( coil of 115 turns of 50 mm.dia. and 2.5 Mtrs. lead of 4.0 mm. G.I wire)
85Installation, testing & commissioning of AAACDog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.)
86Suppy and erectionof single piece nonlinearresistortype lightning arrestorsuitablefor3wire 33KV overheadlines with rated voltage 30KV(rms) with a nominal discharge current ratingof 10KA(stationclass) andcompletewith galvanized clamping arrangement , G.I bolts , nuts, washers etc. as required.
87Suppy and erection of33KVPininsulatorcomplete withlargesteelhead G.I.Pin ,nuts,washers etc as required.
88Stone Block/Pre cast block for base pedding 450x450x75 mm
89Concreting (1:3:6) 0.36 Cmt for [H-Beam - 7 m, 9 m & RSJ 9.3 m, PCC Pole DP / TP/4P/6P of 140 kg. 8 m 200 Kg. 9 m 280 Kg. 9 m], 0.56 Cmt for 11 m,0.60 Cmt for 13 m, 0.67 Cmt for 15 m Per Pole including muffing with Pole Pit digging by Hydra M/c.
90Clamp suitablefor 152 X 152 mm., 37.1 Kg./mtr 13 Mtr. Long H-Beam ( each weight 3.2 kg)
9111KV OUTGOING LINES (06 Nos BAYS)-Installation, testing & commissioning of 200 Kg., 9.0 Mtrs. long PCC Poles
92Installation, testing & commissioning of D.C. Channel 4.8 MTR Centre 100X50X6MM FOR 11KV (each weight-99.90 Kg)
93Installation, testing & commissioning of Back Clamp suitable for 280 Kg PCC Pole (MS Flat 65x8 mm) - each wt 1.92 Kg
94Installation, testing & commissioning of 11 KV Top clamps angle type65x65x6 mm
95Suppy and erection of three piece nonlinear resistor type lightning arrestor suitable for 3wire 11KV overheadlines with rated voltage 9KV(rms) with a nominal discharge current rating of 5KA(station class) and complete with galvanized clamping arrangement , G.I bolts , nuts, washers etc. as required.
96Suppy and erection of11KVPininsulatorcomplete withlargesteelhead G.I.Pin ,nuts,washers etc as required.
97Installation, testing & commissioning of Mesh earthing for New 33/11KV Sub-station inblack cotton soil as per Schedule G-3.1
98Installation, testing & commissioning 1500 KVAR auto switch, 11 KV Capacitor Bank Complete with individual fuses , interconnection , mounting racks, external fuses, mounting arrangement, bas insulator and accessories with earthing and marshelling box
99Installation, testing & commissioning of Earthing of Capacitor Bank as per Schedule G-6.1 (For black cotton soil)
100Installation, testing & commissioning of Earthingwith copperearthplate600mmX600mmX3mmthick including accessoriesand providing masonryenclosurewith cover platehaving locking arrangement and watering pipe of 2.7 mt. long etc with charcoal /coke and salt as required.
101laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect.
102MiscellaneousItems- (i)-Safety helmets
103(ii)- Tong Tester Digital (1000A,500V)with associates accessory
104(iii) - Chain pully block 3ton with 15 metre chain.
105(iv) - wall mounting type holder for hydrometer
106Megger anolog 1000 V
107Megger anolog5000 V.
108(vii)- Battery Hydrometer
109(viii)- Rubber Hand gloves for 15KV (Seamless)
110(ix) - Transformer oil Dielectric Breakdown test kit
111fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge.
112fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work
113fixing of fire extinguisher, ABC Type 9.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
114fixing of C02 type fire extinguisher 6.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
115laying of 11KV 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality.
116Earth Resistance Tester(20/200/2000ohms)Digital
117Filter machine 250GPH (Transformer oil filtration purpose)
118fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.auto/mannual selector switch24hour programmable timer. 40A TPN
119fixing of MCCB) suitable for 3 phase & N, 4 pole, AC supply with micro processor release(MCCB, 25kA, 40 & 100 Amps, 4P)
120fixing of Steel enclosure, neutral bar suitable for MCB /RCBOs/ MCCB (63A/100A, 3P/4P enclosure)
121laying of 4 X 10sq.mm Aluminium cable A2XFY type.
122CABLES & WIRINGS - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface I recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
123Group C
124Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface I recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc .as required.
125Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
126Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
127Wiring for circuiV submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
1282 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1292 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1302 X 4 sq. mm + 1 X 4 sq. mm earth wire
1312 X 6 sq. mm + 1 X 6 sq. mm earth wire
1324 X 10 sq. mm+ 2 X 6 sq. mm earth wire
133Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
1342 Pair
135Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required
136Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
13720 mm
13825 mm
13940 mm
140Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
14175 mm X 75 mm X 60 mm deep
142100mmX100 mm X 60 mm deep
143150 mm X 75 mm X 60 mm deep
144150mmX150 mm X 60 mm deep
145Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1465/6 A switch
1472 way 5/6 A switch
14815/16 A switch
1493 pin 5/6 A socket outlet
1506 pin 15/16 A socket outlet
151Telephone socket outlet
152TV antenna socket outlet
153Bell push
154Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments.(1400 mm sweep)
155Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
156Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
157Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
158Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
159Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
160Upto 450 mm sweep
161Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required
1622 run of cable
163Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator)
1646 way (4 + 18), Double door
1658 way (4 + 24), Double door
166Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninQ etc. as reQuired
167Single pole
168Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
169Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioninQ etc. as reQuired.
17063A
171100A
172Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as reQuired.
173Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
174150 mm width X 50 mm depth X 1.6 mm thickness
175200 mm width X 50 mm depth X 1.6 mm thickness
176Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as reauired.
177150 mm width X 50 mm depth X 1.6 mm thickness
178200 mm width X 50 mm depth X 1.6 mm thickness
179Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as reauired
180150 mm width X 50 mm depth X 1.6 mm thickness
181225 mm width X 50 mm depth X 1.6 mm thickness
182Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted / welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
183fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect
184fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 140 to 150 Watt. Confirming to IP 66 Protection complete in all respects CAT- AAA
185Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
186Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
187Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also includingrammingandwateringoftheearthin layersnot exceeding20cmintrenches,plinth,sidesoffoundationetc. complete.
188Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete
189Providingandlayinginpositioncementconcreteofspecified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
190Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost ofchemicalemulsion):Treatmentofsoilunderexistingfloors usingchemicalemulsion@onelitreperhole,300mmapart includingdrilling12mmdiameterholesandpluggingwith cementmortar1:2(1cement:2Coarsesand)tomatchthe existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
191Reinforcedcementconcreteworkinbeams,suspendedfloors, roofs having slope up to 15° landings, balconies, shelves, chajjas,lintels,bands,plainwindowsills,staircasesandspiral stair cases above plinth level up to floor five level, excluding the costofcentering,shuttering,finishingandreinforcementwith 1:1.5:3(1cement:1.5coarsesand(zone-III):3gradedstone aggregate20mmnominalsize).&Centeringandshuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
192Reinforcedcementconcreteworkinbeams,suspendedfloors, roofs having slope up to 15° landings, balconies, shelves, chajjas,lintels,bands,plainwindowsills,staircasesandspiral stair cases above plinth level up to floor five level, excluding the costofcentering,shuttering,finishingandreinforcementwith 1:1.5:3(1cement:1.5coarsesand(zone-III):3gradedstone aggregate20mmnominalsize).&Centeringandshuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
193Reinforcedcementconcreteworkinbeams,suspendedfloors, roofs having slope up to 15° landings, balconies, shelves, chajjas,lintels,bands,plainwindowsills,staircasesandspiral stair cases above plinth level up to floor five level, excluding the costofcentering,shuttering,finishingandreinforcementwith 1:1.5:3(1cement:1.5coarsesand(zone-III):3gradedstone aggregate20mmnominalsize).&Centeringandshuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
194Providingandlayinginpositionspecifiedgradeofreinforced cementconcrete,excludingthecostofcentering,shuttering, finishingandreinforcement-Allworkuptoplinthlevel: 1:1.5:3(1cement:1.5coarsesand(zone-III):3gradedstone aggregate 20 mm nominal size)
195Reinforced cement concrete work in walls (anythickness), including attached pilasters, buttresses, plinth and string courses, fillets,columns,pillars,piers,abutments,postsandstrutsetc. aboveplinthleveluptofloorfivelevel,excludingcostof centering,shuttering,finishingandreinforcement:1:1.5:3(1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
196Centeringandshutteringincludingstrutting,proppingetc.and removalofformfor:Lintels,beams,plinthbeams,girders, bressumers and cantilevers
197Centeringandshutteringincludingstrutting,proppingetc.and removal of form for :Suspended floors, roofs, landings, balconies and access platform
198Centeringandshutteringincludingstrutting,proppingetc.and removalofformfor:Foundations,footings,basesofcolumns, etc. for mass concrete
199Centeringandshutteringincludingstrutting,proppingetc.and removal of form for :Columns, Pillars, Piers, butments, Posts and Struts
200Brickworkwithcommonburntclaymodularbricksofclass designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand).
201Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floorVlevelinallshapesandsizesinCementmortar1:6(1 cement : 6 coarse sand)
202Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floorVlevelinallshapesandsizesinCementmortar1:4(1 cement : 4 coarse sand)
203Providing&applyingacoatofresidualpetroleumbitumenof grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
204Providing and fixing ISI marked flush door shutters conforming toIS:2202(PartI)non-decorativetype,coreofblockboard construction with frame of 1st class hard wood and well matched commercial3ply veneeringwithverticalgrainsorcross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
205Providing40x5mmflatironholdfast40cmlongincluding fixingtoframewith10mmdiameterbolts,nutsandwooden plugsandembeddingincementconcreteblock30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size
206Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including primingcoatwithapprovedsteelprimerallcomplete.Fixedto steel windows by welding
207Providing and fixing factory made ISI marked steel glazed doors, windowsandventilators,side/top/centrehung,withbeading andallmemberssuchasF7D,F4B,K11BandK12Betc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approvedsteelprimer,butexcludingthecostofotherfittings, completeallasperapproveddesign,(sectionalweightofonly steelmembersshallbemeasuredforpayment). Fixingwith 15x3 mm lugs 10 cm long embeddedin cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
208ProvidingandfixingT-ironframesfordoors,windowsand ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applyingaprimingcoatofapprovedsteelprimer.Fixingwith 15x3 mm lugs 10 cm long embeddedin cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
209SteelreinforcementforR.C.C.workincludingstraightening, cutting,bending,placinginpositionandbindingallcomplete above plinth level.Mild steel and Medium Tensile steel bars
210Fixingofsteelorwoodenchaukhats in position.
211(a) Door chaukhats
212(b) Window chaukhats
213(b) Ventilator chaukhats
21415 mm cement plaster on plinth side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)
21512 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand)
21615 mm cement plaster on rough side of single or half brick wall of mix : (1 cement: 6 coarse sand)
217Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailedtotheunderlayerwithrustproofscrewsandnailsand finishing the groove complete as per specifications and direction of the Engineer-in-Charge.
218Addforplasterdripcourse/grooveinplasteredsurfaceor moulding to R.C.C. projections.
219Cementconcreteflooring1:2:4(1cement:2coarsesand:4 gradedstoneaggregate)finishedwithafloatingcoatofneat cement, including cement slurry, but excluding the cost of nosing ofstepsetc.complete40mmthickwith20mmnominalsize stone aggregate
220Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorptionlessthan0.08%andconformingtoIS:15622,of approvedmake,inallcoloursandshades,laidon20mmthick cement mortar 1:4 (1 cement : 4 coarse sand), jointingwith greycement slurry@3.3 kg/ sqmincluding groutingthejointswithwhitecementandmatchingpigments etc., complete Size of Tile 600x600 mm
221Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorptionlessthan0.08%andconformingtoIS:15622,of approvedmake,inallcoloursandshades,laidon20mmthick cement mortar 1:4 (1 cement : 4 coarse sand), jointingwith greycement slurry@3.3 kg/ sqmincluding groutingthejointswithwhitecementandmatchingpigments etc., complete Size of Tile 600x600 mm
222FinishingwithDeluxeMultisurfacepaintsystemforinteriors andexteriorsusingPrimeraspermanufacturersspecifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
223FinishingwithDeluxeMultisurfacepaintsystemforinteriors andexteriorsusingPrimeraspermanufacturersspecifications :Painting wood work with Deluxe Multi Surface Paint of requiredshade.Twoormorecoatapplied@0.90ltr/10sqm overanundercoatofprimerapplied@0.75ltr/10sqmof approved brand and manufacture
224FinishingwallswithPremiumAcrylicSmoothexteriorpaint withSiliconeadditivesofrequiredshade:Newwork(Twoor morecoatsapplied@1.43ltr/10sqmoverandincluding priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
225Distemperingwithoilboundwashabledistemperofapproved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
226Distemperingwithoilboundwashabledistemperofapproved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
227Providingandapplyingwhitecementbasedputtyofaverage thickness1mm,ofapprovedbrandand manufacturer,over the plasteredwallsurfacetopreparethesurfaceevenandsmooth complete
228Providing&fixingglasspaneswithputty andglazingclipsin steel doors, windows, clerestory windows, all complete with :
229Providingandfixingaluminiumslidingdoorbolts,ISImarked anodisedanodiccoatingnotlessthangradeAC10asperIS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm
230Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless thangrade AC 10 as per IS : 1868)transparentordyedtorequiredcolourorshade,with necessary screws etc. complete :300x10 mm
231Providingandfixingaluminiumhandles,ISImarked,anodised (anodiccoatingnotlessthangradeAC10asperIS:1868) transparentordyed torequiredcolouror shade,with necessary screw setc.complete :100 mm
232Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over theRCCslabincludingadjoiningwallsupto300mmheight including cleaning the surface before treatment. (b) Laying brick batswithmortarusingbrokenbricks/brickbats25mmto115 mmsizewith50%ofcementmortar1:5(1cement:5coarse sand) admixed with water proofing compound conforming to IS : 2645andapprovedbyEngineer-in-chargeover20mmthick layerofcementmortarofmix1:5(1cement:5coarsesand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
233(c)Aftertwodaysofpropercuringapplyingasecondcoatof cement slurry using 2.75 kg/ sqm of cement admixed with water proofingcompoundconformingtoIS:2645andapprovedby Engineerin- charge. (d)Finishingthesurfacewith20mmthickjointlesscement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofingcompoundconformingtoIS:2645andapprovedby Engineerin- charge including laying glass fibre cloth of approved qualityintoplayerofplasterandfinallyfinishingthesurface withtrowelwithneatcementslurryandmakingpatternof 300x300 mm square 3 mm deep.
234(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All aboveoperations to bedone in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
235Providingandfixingdoubleglazedhermetically sealedglazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providingEPDMgasket,perforatedaluminiumspacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
236Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on speciallydesignedpipeshaftwithbrackets,sideguidesand arrangements for inside and outside locking with push and pull operationcomplete,includingthecostofprovidingandfixing necessary27.5cmlongwirespringsmanufacturedfromhigh tensile steel wire of adequate strength conforming to IS: 4454 - part1andM.S.topcoverofrequiredthicknessforrolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
237Providing and fixing ball bearing for rolling shutters.
238Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
239Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conformingtoIS:13592TypeA,includingjointingwithseal ringconformingtoIS:5382,leaving10mmgapforthermal expansion. 110 mm bend
240Providing and fixing unplasticised -PVC pipe clips of approved designtounplasticised-PVCrainwaterpipesbymeansof 50x50x50mmhardwoodplugs,screwedwithM.S.screwsof required length,includingcuttingbrickworkand fixingin cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm