Tender For Repairs And Maint Of Internal Fitting Fixtures, Rewiring Of Internal Electrification Dbs, Ceiling Fans, Exhaust Fans, Air Circulators, Cabin Fans And Connected Works Of Army Area And Od Tech Area Under Ge Avadi., avadi-Tamil Nadu

Military Engineer Services-MES has published Tender For Repairs And Maint Of Internal Fitting Fixtures, Rewiring Of Internal Electrification Dbs, Ceiling Fans, Exhaust Fans, Air Circulators, Cabin Fans And Connected Works Of Army Area And Od Tech Area Under Ge Avadi.. Submission Date for this Tender is 30-10-2023. Electrification Work Tenders in avadi Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

39959046
Corrigendum : Tender For Repairs And Maint Of Internal Fitting Fixtures, Rewiring Of Internal Electrification Dbs, Ceiling Fans, Exhaust Fans, Air Circulators, Cabin Fans And Connected Works Of Army Area And Od Tech Area Under Ge Avadi.
Open Tender
Indian
Tamil Nadu
avadi
30-10-2023

Tender Details

Repairs And Maint Of Internal Fitting Fixtures, Rewiring Of Internal Electrification Dbs, Ceiling Fans, Exhaust Fans, Air Circulators, Cabin Fans And Connected Works Of Army Area And Od Tech Area Under Ge Avadi.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-10-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:REPAIRS & MAINT OF INTERNAL FITTING FIXTURES, REWIRING OF INTERNAL ELECTRIFICATION DBS, CEILING FANS, EXHAUST FANS, AIR CIRCULATORS, CABIN FANS AND CONNECTED WORKS OF ARMY AREA & OD TECH AREA UNDER GE AVADI.
Sl. No. Item Description
1Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, fans etc.,removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc.,complete all as specified and as directed.
2M & L for point wiring with 1.5 Sqmm (nominal area) PVC insulated, FRLSH unsheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 20mm dia and its accessoriesfixing on wall/ceiling/trusses with suitable clamps , screws etc including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover all as specified for :-
3One light point controlled by one switch.
4One Ceiling fan point controlled by one switch.
5One exhaust fan/wall mounted fan point controlled by one switch. Note Sl Item Nos. 2.02 and 2.03:- Item No.55 Will not be measured and paid where Sl. Item Nos. 2.02 & 2.03 needs to be executed
6One 3 pin 5 amps socket point on independent board
7One 3 pin 5 amps socket point on same board
8M & L for pointwiring with 4 Sqmm (nominal area) PVC insulated,FRLSH unsheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 20mm dia and its accessoriesfixing on wall/ ceiling/ trusses with suitable clamps , screws etc including one run of 4 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wallwith 3 mm thick laminated hylam sheet top cover all as specified forOne 5 pin 5/15 amps socket point on independent board complete all as specified
9S&F Switch piano flush type, single pole,5 Amps, 240 volts complete all specified.
10S&F Switch socket 3 pin 5 amps , multi pin , flush type,complete all specified.
11S&F Switch socket 3 pin 15 Amps, multipurpose, flush type complete all specified.
12S&F ceiling rose 65 X 50 mm , three terminals ,bakelite , surface complete all specified.
13S&F electronic fan regulator, flush type phenolic laminated sheet etc complete all as specified.
14S &F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified.
15Supply and Fixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified.
16Fixing onlyLED tube light fitting 20/22 wattconnecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all fixing accessoreis all as specified and directed. Note :- LED Tube light fittings shall be issued by MES department.
17Fixing onlyLED tube light fitting 10 wattconnecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all fixing accessoreis all as specified and directed. Note :- LED Tube light fittings shall be issued by MES department.
18Fixing onlyLED Bulb 9/12/15 watt, B-22 base suitable for operation on AC, single phasecomplete all as specified and directed. Note :- LED Bulb shall be issuied by MES department.
19Supply and fix Decorative ECO bulkhead luminaire capacity 10/12W, environmental friendly ultra modern energy saving surface mounted, LED luminaire comprising of high brightness and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ includint taking down fitting complete all as specified.
20Supply and fix LED building securitylight 25W, made up of pressure die cast housing with toughed glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 incuding drivers, connecter block etc complete pre wired & connecting up with suitable twin core flexble copper wire and suitable bracket all as per dirtected including taking down old light complete all as specified.
21S & F Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmmconforming to IS-694, drawn through and includingsuitable dia rigid PVCconduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistrandedcopper conductorcable (green) asearth continuity conductorfixed on wallsceiling / roof trusses etc with fixing accessories complete and connecting tocommon earth dolly complete including taking down unserviceable submain wiring with accessories complete all as specified and as directed.
22S & F Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, four runs of single core 10 sqmmconforming to IS-694, drawn through and includingsuitable dia rigid PVCconduit, conduit fittings and conduit accessories alongwith one run 10 sqmm PVC insulated single core multistrandedcopper conductorcable (green) asearth continuity conductor fixed on wall/ ceiling / roof trusses etc. and connecting tocommon earth dolly complete including taking down unserviceable submain wiring with accessories all as specified and as directed.
23Supply and fixing 240V, 10 KA "B" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
24Supply and fixing 240V, 10 KA "B" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DBComplete with connection testing and commissioning complete all as specified.
25Supply and fixing 240V, 10 KA "B" curve miniature circuit breaker (MCB) of SPN and current carrying capacity 40-63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
26Supply and fixing 415V 10KA "B" curve miniature circuit breaker (MCB) of TPN and current carrying capacity 40-100 Ampin the DB complete with connection testing and commissioning complete all as specified.
27S&F MCB DB SPN 8 way, doubledoor, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCBdouble pole as incomer andSP MCBs as outgoing with tinned copper bus bar, neutral link, earth linkand connecting up complete all as specified and as directed. Note : Incomingand Outgoing MCB measured separately relevent items.
28S&F MCB DB SPN 4 way, doubledoor, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCBdouble pole as incomer andSP MCBs as outgoing with tinned copper bus bar, neutral link, earth linkand connecting up complete all as specified and as directed. Note : Incomingand Outgoing MCB measured separately relevent items.
29S&F Vertical Load line DB TP&N 4 way,doubledoor, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for FP MCCB 100 Amps as incomer and SP MCBs 40 / 63 Amps as outgoing with tinned copper bus bar, neutral link, earth linkand connecting up complete all as specified and as directed. Note : Incoming MCCB and Outgoing MCB measured separately relevent items.
30S&FMCB DB TPN 4 way,distribution DB double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for TPN MCB 63 Amps as incomer and SP MCBs 40Amps as outgoing with tinned copper bus bar, neutral link, earth linkand connecting up complete all as specified and as directed. Note : Incoming MCB and Outgoing MCB measured separately relevent items.
31S&F MCCBs100 Amps 415V,16KA, 4 Pole complete all as specified .
32Material and labour for earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire all as specified and directed by Engr-in-Charge
33Earthing complete with galvanised iron earth plate electrode 600mm X600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directlyin ground vertically to a depth not lessthan2.25 metres below ground level with top edge of the earth plateat a depth not less than1.5 metres belowgroundlevel, connectedto earth leadasdescribedhere-in-beforebymeansofbolts,nuts, washers and checknuts made out ofgalvanised iron or mild steel, earthingleadprotectedby asdescribedhere-in-beforeand connected to main switch board or main control board or electric poleall asshownonelectricalplate No.3of MES Sch Part-Iincluding necessaryearth work and excavation in any type ofsoil,plain cementconcrete1:3:6,typeC1 chamber,reinforcedcement concretecover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm diaTMT barsat140mmcentreto centrebothways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugsincluding testing complete all as specified and as directed.
34Taking down carefully the Ceiling fanof any size/ make after disconnecting the electric connections for necessary servicing and replacing the spares, rewinding etc., all as specified and directed. Note: Servicing, Spares, Refixing and Rewinding shall be measured and paid for separately.
35Taking down carefully the Exhaust fanof any size/ make after disconnecting the electric connections for necessary servicing and replacing the spares, rewinding etc., all as specified and directed. Note: Servicing, Spares, Refixing and Rewinding shall be measured and paid for separately.
36Taking down carefully the Wall-mounted/ Air-circulator fansof any size/ make after disconnecting the electric connections for necessary servicing and replacing the spares, rewinding etc., all as specified and directed. Note: Servicing, Spares, Refixing and Rewinding shall be measured and paid for separately.
37Hanging only ceiling fan any sweep any make, 230 V single phase and connecting up with PVC insulated cable size 1.50 sqmm three core copper conductor round cable complete all as specified. Note:- The refixed fan shall be tested after fixing the blades.
38Fixing only Exhaust fans along with louver any description any make,230 V single phase and connecting up with PVC insulated cable size 1.50 sqmm three core copper conductor round cable including grouting of nut, bolt on existing location andcomplete all as specified and directed. Note : The refixed fan shall be tested after fixing the blades.
39Fixing only Wall-mounted/ Air-circulator fans of any description any make, 230 V single phase and connecting up with PVC insulated cable size 1.50 sqmm three core copper conductor round cable including necesary fixing arrangements if existing fixing arrangements found unserviceable, on existing location etc., complete all as specified and as directed. Note : The refixed fan shall be tested after fixing the blades.
40Material and Labour for painting of ceiling fans of any sweep to obtain even, smooth & glossy finish, with synthetic enamel paint of approved colour by using paint spraying devices after filling cavities with filler after cleaning all dust etc., over fan surfaces; complete including writing SM/MES No. in synthetic enamel paint (Black colour) over the same surface where the existing No. was written etc., all as specified and as directed.
41Material and Labour for painting of Exhaust/ Pedestal/ Wall-mounted/ Air-circulator fans of any sweep to obtain even, smooth & glossy finish, with synthetic enamel paint of approved colour by using paint spraying devices after filling cavities with filler after cleaning all dust etc., over fan surfaces; complete including writing SM/MES No. in synthetic enamel paint (colour as approved) over the same surface where the existing No. was written etc., all as specified and as directed.
42Material and Labour for rewinding of fan motor with super enameled copper winding wire of same gauge and weight after cutting and removing the existing burnt/heated up windings, including cleaning of rotor, stator and varnishing, heating and providing fresh insulating materials for Ceiling fan of 1200/1400 mm sweep including dismantling and reassembling.
43All as per Item No. 37 herein before but for Exhaust fan 225 to 300mm sweep
44All as per Item No. 37 herein before but for Pedestal fan/Air circulator fan400 to 600mm sweep
45All as per Item No. 37 herein before but for wall mounted fan 400mm sweep
46Supply only ball bearing suitable for ceilingfan of size 1200/1400mm sweep
47Supply only ball bearing suitable for exhaust fan of any size and make
48Replacementof old/unserviceable capacitor of capacity 2.5 µfd for the fans in position as directed.
49Replacementof old/unserviceable capacitor of capacity 4 µfd for the fans in position as directed.
50Labour only for servicing the ceiling of any size/ make includinggreasing/ oiling/repairs and replacing the spares such as cater pin unserviceable/rusted nut bolts, split pins rubber wheel bearing washers, bush , and connected items all as specified and directed
51Supply and fix PVC canopy/Ceiling fan cap with fixing screws etc suitable for ceiling fan 1200/1400mm sweep etc., complete; all as specified and as directed
52Supply and fix ceiling fan blade with fixing accesories etc suitable for ceiling fan 1200/1400mm sweep etc., complete; all as specified and as directed
53Supply and fix exhuast fan blade (metal body)with fixing accessories etc suitable for exhaust fan 300mm sweep etc., complete; all as specified and as directed
54Supply and fix exhuast fan louver (shutter) metal bodywith fixing accessories etc suitable for exhaust fan 300mm sweep etc., complete; all as specified and as directed
55Taking down down rods of ceiling fans (1200/1400 mm sweep) fixed by means of check nut and split pin, "U" clamp bolts, nuts, washers, rubber split pin check nut etc., complete; all as specified and as directed.
56Supply and Fix ceiling fans down rods fabricated out of 15 mm dia GI pipe medium grade duly cutting/ threading/ drilling etc. Suitable for ceiling fans (1200/1400 mm sweep) fixed by means of check nut and split pin, "U" clamp bolts, nuts, washers, rubber split pin check nut etc., complete; all as specified and as directed.
57Taking down existing un serviceable check nut and split pin including "U" clamp bolts, nuts, washers, rubber split pin check nut etc.,complete; from ceiling fan 1200/1400 mm sweep etc., all as specified and as directed.
58Supply and Fix check nut and split pin including "U" clamp bolts, nuts, washers, rubber split pin check nut etc suitable for ceiling fan 1200/1400 mm sweep etc., complete; all as specified and as directed. Note for item No. 29 to 52:- Repairs/ painting shall be carried out only to the fans where SM No. is available over the fans and the contractor shall ensure the same before carrying out such repairs/ painting.
59Supply and Fix ceiling fan hook made out of 40 x 6 mm MS flat iron and 10 dia MS round bar bend to shape for hanging ceiling fans including taking down existing unserviceable fan hook complete; all as specified and as directed.
60Rectifying faults by attending faults of point/sub main wiring complaints (excluding fittings and fixtures) any rating/ make/ model/ type in position including testing of serviceability of point wiring, finding of fault/ defect and repairing, jointing of wires/ cables properly with required jointing materials and making wiring functional etc., complete; all as specified and directed. Note:-(i) The rate quoted is deemed to be inclusive of cost of the required materials like insulation tape etc where required. (ii)Provn of point/sub mainwiring including taking down of the same will be paid under relavent items. (iii) Contractor or his accredited Engineer/ representative shall collect the list of daily complaints from Complaint Cell. (iv) Contractor shall submit the daily list of all rectified/ non-rectified complaints to the Engineer-in-charge at the end of the day"s work on each working day of unit/ AGE"s office.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail