| 1 | M & L for 6 mm thick EPU floor coating system including surface preparation by clearing from dust, muck,moisture & all foreign material and cleaned by mechanical scrubber/grinder,chemical treatment for oil if required followed by application of primer cipoxy 11 which shall be a two component, solvent free,epoxy polyamido amine system having a volumetric ratio of mixing of 1:1 to yield a thickness of 200 microns then providing and applying the screed layer with cipoxy 17 of minimum thickness of 3700 microns .The self levelling screed shall consist of a low viscous epoxy-amine cured system and graded aggregates (special silica). the epoxy system shall have a volumetric ratio of mixing of resin in 1:1 ratio.the aggregates shall be added on the rate of 1:3 or 1:3.5, laying of copper tape at a distance of 10 mtr (horizontal and vertical),Applying 100 microns thick conductive coat having mixing ratio 3:1 and finally epoxy polyurethane (EPU) ESD top coat of cipy cipothane ESD which is a pre-weighed pack ready to mix and use which will consists of resin,hardner,EPI (colour concentrate) formulated aggregates & carbon fibre including repair to craks , pothole and making expension joint wherever required .All these 5 parts to be added to agitate the mixture by an electrically driven motor and lay the mixture to the thickness of 2000 microns complete all as specified and directed. |
| 2 | S&F Linoleum 4.5 mm thick plain coloured, laid dry in floors including stretching, cuttings and fittings fixed with an approved adhesivecomplete all as specified and directed. |
| 3 | Demolition of cement concrete un reinforced in ground floors and pavings not exceeding 15 cm thickness below or above GL complete all as specified and directed.. |
| 4 | M&L cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less, cement ramp with \"trimix flooring using vacuum dewatering method and power traweling with skim floter complete all as specified and directed. |
| 5 | S &F Aluminium dividing strips, 38mm wide, 1.5mm thick and inserted in position to conform to design complete all as specified and directed. |
| 6 | M & L for PCC (1:2:4) type B1 using 20mm graded stone aggregatein mass concrete, copings, kneelers, apex stones, slightly rounded for chamfered angles and throating complete all as specified and directed. |
| 7 | M&L Formwork to edges of flat surface concrete , breaks in floors, openings in concrete walls,floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and openingfor rough finished surface complete all as specified and as directed. |
| 8 | S&F in repairsupto 150 mm cast iron soil rain waterpipes in any length with or without ears with cement joints fixed to walls/floorcomplete all as specified and directed. |
| 9 | S&F150 mm bore CI Bends (any radius) with duck\"s foot or heel rest (ISI marked), complete all as specified and directed. |
| 10 | S & F supporting angles, Bands, straps, supports or stays for cable ducting, ventilating pipes, similar small articles conforming to Fe290 or Gde E-165 complete all as specified and directed. |
| 11 | S & FPlates (plain or chequered)Square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W(Gde-E-250) quality-B complete all as specified and directed. |
| 12 | M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coasts of synthetic enamel paint over one coat of red oxide primer (for steel surfaces) complete all as specified and directed. |
| 13 | M&L for 15 mm thick cement plaster with readymix plaster (as per manufaturer\"s instruction) on fair faces of brick wall/floor or concrete surfaces finished even and smooth, (without using extra cement) including taking down complete all as specified and directed.Note: Make of readymix plaster shall be Birla Airocon/Ultra Tech Readyplast/ACC Accoplast/Fosroc Chemical (India) Pvt Ltd Renderoc and Approved by GE. |
| 14 | M&L for preparation of new plastered surfaces of walls and applying two coat of oil bound distemper of approved tint over a coat of 1 mm thick wall care putty as a primer complete all as specified and directed. |
| 15 | M&L for brick work with sub class \"B\" bricks, straight of curved on plan exceeding 6M mean radius built in cement mortar 1:6complete all as specified and directed. |
| 16 | M&L for replacement of gear box of steel rolling shutter including handle rack & pinion system, ball bearing, End Cap, Aluminium Box Top Octagonal Tube Security Spring etc for rolling shutter of size exceeding 5 sqm but not exceeding 25sqm each to make it serviceable Including minor repair complete all as specified & directed. |
| 17 | Material & labour for providing & applying Polyurethane Cipy make primer Duraprime and sealant Episeal in Expansion joints. It includes cut open the existing joints, removal of existing sealant / bitumen etc. and laying Cipy make Episeal in the Expansion joints 25mm x 20mm complete all as specified and directed. |
| 18 | Material & labour for providing & applying Polyurethane Cipy make demarcation system with FK 666/ FPG 700 on coated surface complete all as specified and directed. |
| 19 | Supply andlaying synthetic rubber insulation mats 2 mm thick for voltage upto 3.3KV for electrical purposeas per IS 15652-20006,(Superseding IS5424 ) suitable for electrical shock safety of size 2 m x 1 m complete all as specified and directed. |
| 20 | S&F MS sheet0.5 mm thickness forcovering LT Panels Angle Girder Portion complete all as specified and directed. |
| 21 | S&Fduct cover 2 m x 65Cm x 5mm complete all as specified and directed. |
| 22 | Supply, installing, testing and commissioning CPRI approved factory made and tested LT Panel Indoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-42) and made of 2.00 mm thick CRCA Sheet & suitable frame work/ support made out of 40 x 40 x 5 mm MS Angle, back and front both side opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:- |
| 23 | BUS BAR CHAMBER :- (a)500 Amp 3 Strips & Neutral Strip 250 Amp, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500V, with Volt meter selector switch- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-600A, with Amp meter Selector switch- 01 Set.(iii) C.T\"s 600/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)(iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).(v) Protection MCB 6 A SP C Series- 1 Set. (Set of three). INCOMING:-(i) MCCB 250 Amp ,4 Pole 35 KA , 415 V(ICS=ICU=ICW for 1 Sec) ,thermal Magnetic Release (Manual Drawout Type ) Type of Operation :Electrical by 230 V ACXMotor and Manual HandleOUTGOING :- (i) MCCB 125 Amps 25 KA ,4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=01 Nos.,(ii) MCCB 63 Amps 25 KA ,4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=02 Nos. |
| 24 | Supply, installing, testing and commissioning CPRI approved factory made and tested LT Panel Indoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-42) and made of 2.00 mm thick CRCA Sheet & suitable frame work/ support made out of 40 x 40 x 5 mm MS Angle, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:- |
| 25 | BUS BAR CHAMBER :- (a)1000 Amp 3 Strips & Neutral Strip 630 Amp, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500V, with Volt meter selector switch- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-600A, with Amp meter Selector switch- 01 Set.(iii) C.T\"s 600/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)(iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).(v) Protection MCB 6 A SP C Series- 1 Set. (Set of three). INCOMING SUPPLY :-(i) ACB 630 Amp ,4 Pole 50 KA , 415 V(ICS=ICU=ICW for 1 Sec) ,thermal Magnetic Release (Manual Drawout Type ) of capacity 630 Amps Type of Operation :Electrical by 230 V ACMotor and Manual Handle OUTGOING SUPPLY :- (i) MCCB 125 Amps 25 KA ,4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=04 Nos., |
| 26 | Supply, installing, testing and commissioning CPRI approved factory made and tested LT Panel Indoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-42) and made of 2.00 mm thick CRCA Sheet & suitable frame work/ support made out of 40 x 40 x 5 mm MS Angle, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:- |
| 27 | BUS BAR CHAMBER :- (a)500 Amp 3 Strips & Neutral Strip 250 Amp, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500V, with Volt meter selector switch- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-600A, with Amp meter Selector switch- 01 Set.(iii) C.T\"s 600/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)(iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).(v) Protection MCB 6 A SP C Series- 1 Set. (Set of three). INCOMING SUPPLY :-(i) MCCB 630 Amp ,4 Pole 35 KA , 415 V(ICS=ICU=ICW for 1 Sec) ,thermal Magnetic Release (Manual Drawout Type )Type of Operation :Electrical by 230 V ACXMotor and Manual HandleOUTGOING SUPPLY :- (i) MCCB 100 Amps 25 KA ,4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=01 Nos.,(ii) MCCB 63 Amps 25 KA ,4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=03 Nos., |
| 28 | S&fDuct Cover 1m x 65cm x 5mm complete all as specifed and directed. |
| 29 | Taking out heavy duty MS duct cover 1.2 mx 0.7 m x 0.008m or weighing upto 80 kg for taking out old unsv cable and refixing the duct cover after taking unsv and refixing the same of any size and capacity in the duct complete all as specified and as directed. |
| 30 | M&L in replacementXLPE insulated, armouredheavy duty electric cable of 1100 volts grade, cross-sectional area 120 sqmm 3.5 core complete all as specified and as directed. |
| 31 | M&L in replacementXLPE insulated, armouredheavy duty electric cable of 1100 volts grade, cross-sectional area 95 sqmm 3.5 core complete all as specified and as directed. |
| 32 | M&L in replacementXLPE insulated, armouredheavy duty electric cable of 1100 volts grade, cross-sectional area 50 sqmm 3.5 core complete all as specified and as directed. |
| 33 | M&L in replacementXLPE insulated, armouredheavy duty electric cable of 1100 volts grade, cross-sectional area 35 sqmm 3.5 core complete all as specified and as directed. |
| 34 | Taking down old unsv LT feeder panel after dissconnecting cable and necessary fastening elements with safety complete all as specified and directed |
| 35 | Schedule of Credit |