Carrying Out The 20 Nos. Work Work Increasing Capacity Of 11 / 0.4 Kv S / S At Different Places Under Eudd-I / V / Vii, Noida In The Juridiction Of Eudc-I, Noida ( System Strengthening Works In Municipal Area Including Noida Rs. 72.00 Crore For Noida Z, noida-Uttar Pradesh

Paschimanchal Vidyut Vitran Nigam Limited has published Carrying Out The 20 Nos. Work Work Increasing Capacity Of 11 / 0.4 Kv S / S At Different Places Under Eudd-I / V / Vii, Noida In The Juridiction Of Eudc-I, Noida ( System Strengthening Works In Municipal Area Including Noida Rs. 72.00 Crore For Noida Z. Submission Date for this Tender is 02-10-2023. Substation Tenders in noida Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39914455
Carrying Out The 20 Nos. Work Work Increasing Capacity Of 11 / 0.4 Kv S / S At Different Places Under Eudd-I / V / Vii, Noida In The Juridiction Of Eudc-I, Noida ( System Strengthening Works In Municipal Area Including Noida Rs. 72.00 Crore For Noida Z
Open Tender
Indian
Uttar Pradesh
noida
02-10-2023

Tender Details

Carrying Out The 20 Nos. Work Work Increasing Capacity Of 11 / 0.4 Kv S / S At Different Places Under Eudd-I / V / Vii, Noida In The Juridiction Of Eudc-I, Noida ( System Strengthening Works In Municipal Area Including Noida Rs. 72.00 Crore For Noida Zone ) .-2 Cartage Of Pcc Poles 8.5 Mtr Long From Esc Noida / Sahibabad / Ghaziabad / Any Other Esc Of Meerut Discom To Je Store And From Je Store To Site Of Work Including Loading And Unloading At Both Ends. 3 Cartage Of Lt Abc 3X120+1X95+1X16 Sq.Mm. From Esc Noida / Sahibabad / Ghaziabad / Any Other Esc Of Meerut Discom To Je Store And From Je Store To Site Of Work Including Loading And Unloading At Both Ends. 4 The Excavation Of Foundation Pit In Cc Road / Mix Soil / Normal Soil / Soft & Hard Rack By Using Heavy Duty Compressor And Its Back Filling And Leveling Etc. The Size Of The Pit Will Be 600X600x1800 Mm For Each Pole And Having A Depth Of 1 / 6 Of The Full Length Of The Support. 5 Erection Of Pole On 8.5 Mtr. Long Pcc Pole For Lt Line Including Fixing Of All Accessories Of Lt Line As Per Respo Schedule Complete In All Respects. 6 Grouting Of Each Pole ( In Ratio Of 1:4:8 In Cement, Sand And Brick Ballast ) In Size 450Mmx450mmx1800 Mm As Per Respo Schedule Complete In All Respects. 7 Laying, Lifting And Final Binding, Sagging Of Lt Abc Lt Abc 3X120+1X95+1X16 Sq.Mm. Including Fixing Of All Accessories As Per Respo Schedule Complete In All Respects. 8 Providing & Fabrication / Fixing Of Following Material Of Best Quality For Completion Of Work As Per Site Requirement :- 9 11 Kv Fuse Set 10 Lt Pvc Cable Al. 1X630 Sq.Mm. 11 Lt Pvc Cable Al. 1X400 Sq.Mm. 12 Al. Lug Long Barrel, Off Size ( Ls ) 630 Sq.Mm. 13 Suspension Clamp With I-Hook 14 Dead End Clamp With I-Hook 15 Lt Piercing Connector For Size 120 / 95 16 Construction Of New Distribution 400 / 250 Kva T / F Plinth. The Size Of Plinth Shall Be 2 Mtrs. Long, 2 Mtrs. Wide And Height 1.5 Mtrs. From Ground Level With 15 Cm Thick Top Cc Slab. The Above Work Includes Excavation Of Earth, Laying Of Bring Ballast Pad For Foundation Brick Work, Cc And Plastering And Proper Curing Complete With All Respects As Per Respo Schedule. 17 Safe Loading And Carriage Of 400 Kva T / F ( 24 Nos. ) , 250 Kva T / F ( 03 Nos. ) & 100 Kva T / F ( 01 No. ) From Esc Noida / Sahibabad / Ghaziabad / Any Other Esc Of Meerut Discom To Je Store And From Je Store To Site Of Work Including Loading And Unloading At Both Ends 18 Mounting, Installation Of 400 Kva T / F ( 24 Nos. ) , 250 Kva T / F ( 03 Nos. ) & 100 Kva T / F ( 01 No. ) On Above / Existing Plinth, Alongwith Double Earthing Of The Same, Complete In All Respect As Per Respo Schedule. 19 Providing And Installation Oflt Acb630 Amp. With Cabinet / Structure ( Make L&T, Schneider, Abb, HevellS ) As Per Following Specification With All Relevant Certificate :- 20 630 Amp. 03 Pole Fixed Manual Acb. 21 Red / Yellow / Blue Light Indication 22 On & Off Indication 23 Amp., Voltmeter& Energy Meter Digital 24 Metering C.T 630 / 5A, 25 Panel Fabrication Of Size 1250Mm X 900Mm X 600 Mmmade Of M.S Sheet 14 Gauge With Powder Coating With Panel Lock And Key Arrangement. ( Two Nos ) . And Additional Locking Arrangement Seprately Including Providing Hut Type Shape As Per Drg. 26 Fabrication Ofaluminium Bus-Bar For Each Phases 27 Incoming Size 425 Mm X 50Mmx12 Mm ( Twin ) 28 Out Going Size 720 Mm X 50Mm X 12 Mm ( Twin ) 29 Neutral Size 900Mmx50mmx12 Mm. 30 Fabrication Of Pannel Stand Made Of M.S Angle Of Size 900Mm X 600Mm X 500 Mm As Per Drg. 31 Assembly Of Above Acb, Indicators, Meters, Metering Ct & Bus Bar Arrangment In The Panel, Fitting The Panel On Stand With Nut And Boltswith Wiringetc. & Grouting Inratio 1:4:8 With Cement, Coarse Sand And Brick Blast. 32 Providing And Fixing Of Aluminium Bus Bar Of Size 300Mmx60mmx12 Mm On L.T Side Of T / F. 33 Making All Connections With Acb & Distribution T / F And Commissioning The Acb Complete In All Respect. 34 Providing And Installation Of Chemical Earthing For Distribution Transformers ( Body & Neutral ) And Acb ( With All Material And Labour ) After Installation Resistance Should Be Less Than One Ohm. As Per Following ( The All Material And Labour Shall Be Provided By The Contractor With 12 Month Guarantee For Resistance Value Less Than One Ohm. ) :- 35 Providing Of Earth Elctrode For Chemical Earthing Pipe In Pipe Typeproper Hot Deep Galvanization Dia 50 Mm Length 3 Mtr- 32Mm X 6Mmterminal Connection Hole Dia 8Mm The Cavity Between The Pipe & Pipe Is Filled With Conductive Mixture - For Hermetically Filling Inside The Cavity I.E. Between Secondary Conductor & Primary Conductor, Crystalline Compound Is To Be Injected In The Electrode Assembly. It Is A Combination Of High Conductivity Metal Alloys, Copper & Aluminum Power, Conductive Carbon / Cement And Bonding Material Etc The Electrode Should Be Sealed From Both The Ends. The Outer Pipe Of The Elctrode Should Be Galavanized The Characteristics Of This Compound Is Highly Cnductive, Non Magnetic & Non Corrosive In G.I. Including Providing Of Backfill Compound Each Elctrode Should Be Supplied With Bags Of 25 Kg X 2 Bfc Compound ( Ground Resistance Enhancement Powder 50 Kgs Each Cpri Tested For Dstribution T / F & Acb Installed At Above 11 / 0.4 Kv L.T. Substation. 36 Providing And Fixing Of Gi Strip Of Size 32 Mm X 6 Mm Suitable For Distribution T / F & Acb Installed At Above 11 / 0.4 Kv L.T. Substation. 37 Providing And Fixing Of Pvc Pit Covers For Above Earthing Electrode Terminals. 38 Work Of Providing And Fixing Of 14 Nos. New Wiremesh Fencing Of 11 / 0.4 Kv L.T. Sub-Station Installed At Above Place As Per Following :- 39 Providing & Fixing Of New Wiremesh Fencing Frames Of Size 12X15X6For Each Fencing Of Lt Sub-Stations. ) ( All Material Provided By Contractor For Above Work. ) 40 Construction Of Boundry / Toe Wall In Bottom Of Fencing In Brick Work Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) For Link In The Size Of 0.22Mx0.60M ( 0.30M In Earth, 0.30M Above Ground Level ) Including Plaster In Cement Mortar 1:4 And Finishing With Water Proof Cement Paint. ( Approx Construction 12 Mtrs. Boundry / Toe Wall For Each Fencing Of Lt Sub-Stations. ) ( All Material Provided By Contractor For Above Work ) 41 Disconncetion Of All Jumper / Connection From T / F As Per Requirement. 42 Reconncetion Of All Jumper / Connection From T / F After Replacement As Per Requirement. 43 Dismantling Of Existing 250 Kva T / F ( 24 Nos. ) , 160 Kva T / F ( 01 No. ) , 100 Kva T / F ( 01 No. ) & 63 Kva T / F ( 02 No. ) From Work Site. 44 Carriage Of Above Dismantled 250 Kva T / F ( 24 Nos. ) , 160 Kva T / F ( 01 No. ) , 100 Kva T / F ( 01 No. ) & 63 Kva T / F ( 02 No. ) From Works Site To Je Store / Central Store & Proper Stacking With Loading & Unloading.

Key Value

Document Fees
INR 3540 /-
EMD
INR 60730.0 /-
Tender Value
INR 60.73 Lakhs /-

BOQ Items

Name of Work:DETAILS OF WORK AND QUANTITY AGAINST E-TENDER NO. 53/EUDC-I/2023-24/NOIDA (WORKS) FOR CARRYING OUT THE 20 NOS. WORKWORK INCREASING CAPACITY OF 11/0.4 KV S/S AT DIFFERENT PLACES UNDER EUDD-I/V/VII, NOIDA IN THE JURIDICTION OF EUDC-I, NOIDA (SYSTEM STRENGTHENING WORKS IN MUNICIPAL AREA INCLUDING NOIDA RS. 72.00 CRORE FOR NOIDA ZONE).
Sl. No. Item Description
1FOLLOWING 20 NOS. WORKWORK INCREASING CAPACITY OF 11/0.4 KV S/S AT DIFFERENT PLACES :-
2Cartage of PCC poles 8.5 mtr long from ESC Noida/Sahibabad/ Ghaziabad /Any other ESC of Meerut Discom to JE Store and from JE store to site of work including loading and unloading at both ends.
3Cartage of LT ABC 3x120+1x95+1x16 Sq.mm. from ESC Noida/Sahibabad/ Ghaziabad /Any other ESC of Meerut Discom to JE Store and from JE store to site of work including loading and unloading at both ends.
4The Excavation of foundation pit in CC road/ mix soil/ normal soil/ soft & hard rack by using heavy duty compressor and its back filling and leveling etc. The size of the pit will be 600x600x1800 mm for each pole and having a depth of 1/6 of the full length of the support.
5Erection of Pole on 8.5 Mtr. long PCC Pole for LT line including fixing of all accessories of LT line as per RESPO schedule Complete in all respects.
6Grouting of each pole (In ratio of 1:4:8 in Cement, sand and Brick Ballast) in size 450mmx450mmx1800 mm as per RESPO schedule Complete in all respects.
7Laying, Lifting and final Binding, Sagging of LT ABC LT ABC 3x120+1x95+1x16 Sq.mm. including fixing of all accessories as per RESPO schedule Complete in all respects.
8PROVIDING & FABRICATION / FIXING OF FOLLOWING MATERIAL OF BEST QUALITY FOR COMPLETION OF WORK AS PER SITE REQUIREMENT :-
911 KV Fuse Set
10LT PVC Cable Al. 1x630 Sq.mm.
11LT PVC Cable Al. 1x400 Sq.mm.
12Al. Lug Long Barrel, Off Size (LS) 630 Sq.mm.
13Suspension Clamp with I-Hook
14Dead End Clamp with I-Hook
15LT Piercing Connector for size 120/95
16Construction of new distribution 400 / 250 KVA T/F Plinth. The size of plinth shall be 2 Mtrs. long, 2 Mtrs. wide and height 1.5 Mtrs. from ground level with 15 CM thick top CC slab. The above work includes Excavation of earth, laying of bring ballast pad for foundation brick work, CC and plastering and proper curing complete with all respects as per RESPO schedule.
17Safe loading and carriage of 400 KVA T/F (24 Nos.), 250 KVA T/F (03 Nos.) & 100 KVA T/F (01 No.) from ESC Noida/Sahibabad/ Ghaziabad /Any other ESC of Meerut Discom to JE Store and from JE store to site of work including loading and unloading at both ends
18Mounting, installation of 400 KVA T/F (24 Nos.), 250 KVA T/F (03 Nos.) & 100 KVA T/F (01 No.) on above / existing Plinth, alongwith double earthing of the same, complete in all respect as per RESPO schedule.
19Providing and installation ofLT ACB630 Amp. with cabinet / structure (Make L&T, Schneider, ABB, Hevell"s) as per following specification with all relevant certificate :-
20630 amp. 03 pole fixed manual ACB.
21Red/yellow/blue light indication
22ON & OFF Indication
23Amp., Voltmeter& energy meter digital
24Metering C.T 630/5A,
25Panel fabrication of size 1250mm x 900mm x 600 mmmade of M.S sheet 14 gauge with powder coating with panel lock and key arrangement.(two nos). and additional locking arrangement seprately including providing hut type shape as per drg.
26Fabrication ofaluminium bus-bar for each phases
27Incoming size 425 mm x 50mmx12 mm (twin)
28Out going size 720 mm x 50mm x 12 mm(twin)
29Neutral size 900mmx50mmx12 mm.
30Fabrication of pannel stand made of M.S Angle of size 900mm x 600mm x 500 mm as per drg.
31Assembly of above ACB, Indicators, Meters, Metering CT & bus bar arrangment in the panel, fitting the panel on Stand with nut and boltswith wiringetc. & grouting inratio 1:4:8 with cement, coarse sand and brick blast.
32Providing and fixing of aluminium bus bar of size 300mmx60mmx12 mm on L.T side of T/F.
33Making all connections with ACB & Distribution T/F and commissioning the ACB complete in all respect.
34PROVIDING AND INSTALLATION OF CHEMICAL EARTHING FOR DISTRIBUTION TRANSFORMERS (BODY & NEUTRAL) AND ACB (WITH ALL MATERIAL AND LABOUR) AFTER INSTALLATION RESISTANCE SHOULD BE LESS THAN ONE OHM. AS PER FOLLOWING (The all material and labour shall be provided by the contractor with 12 month guarantee for resistance value less than one OHM.) :-
35Providing of earth elctrode for chemical earthing Pipe in pipe typeproper hot deep galvanization dia 50 mm length 3 mtr- 32mm x 6mmterminal connection hole dia 8mm The cavity between the pipe & pipe is filled with conductive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystalline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be galavanized the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested for Dstribution t/f & ACB installed at Above 11/0.4 KV L.T. Substation.
36Providing and fixing of GI strip of size 32 mm x 6 mm suitable for distribution t/f & ACB installed at Above 11/0.4 KV L.T. Substation.
37Providing and fixing of PVC Pit covers for above earthing electrode terminals.
38WORK OF PROVIDING AND FIXING OF 14 NOS. NEW WIREMESH FENCING OF 11/0.4 KV L.T. SUB-STATION INSTALLED AT ABOVE PLACE AS PER FOLLOWING :-
39Providing & Fixing of new WIREMESH fencing frames of size 12"X15"x6"for each fencing of LT Sub-stations.) (All Material provided by contractor for above work.)
40Construction of boundry / toe wall in bottom of fencing in brick work cement mortar 1:6 (1 cement : 6 coarse sand) for link in the size of 0.22mx0.60m (0.30m in earth, 0.30m above ground level) including plaster in cement mortar 1:4 and finishing with water proof cement paint. (Approx construction 12 Mtrs. boundry / toe wall for each fencing of LT Sub-stations.) (All Material provided by contractor for above work)
41Disconncetion of all jumper / connection from T/F as per requirement.
42Reconncetion of all jumper / connection from T/F after replacement as per requirement.
43Dismantling of existing 250 KVA T/F (24 Nos.), 160 KVA T/F (01 No.), 100 KVA T/F (01 No.) & 63 KVA T/F (02 No.) from work site.
44Carriage of above dismantled 250 KVA T/F (24 Nos.), 160 KVA T/F (01 No.), 100 KVA T/F (01 No.) & 63 KVA T/F (02 No.) from works site to JE store / central store & proper stacking with loading & unloading.