| 1 | Erection AND COMMISSIONING OF SAS C&R 132 kV and 33kV C&R Panel |
| 2 | 132 kV C&R Panel Type SAS- For Transformer Control (suitable for automation/remote operation)with BCU & all associate items |
| 3 | 132 kV C&R Panel Type SAS- For Feeder Control (suitable for automation/remote operation)with BCU & all associate items |
| 4 | 132 kV C&R Panel Type SAS- For Bus coupler bay Control (suitable for automation/remote operation)with BCU & all associate items |
| 5 | 33 kV C&R Panel (for 1T+2F) Type SAS-(suitable for automation/remote operation)with BCU & all associate items |
| 6 | 33 kV C&R Panel (for 3F) Type SAS-(suitable for automation/remote operation)with BCU & all associate items |
| 7 | 33 kV C&R Panel (for 2F) Type SAS-(suitable for automation/remote operation)with BCU & all associate items |
| 8 | 33 kV C&R Panel for CAP. Bank Type SAS-(suitable for automation/remote operation)with BCU & all associate items |
| 9 | Erection AND COMMISSIONING OF Substation SAS System with Networking Panel SAS-NW |
| 10 | Substation SAS System with Networking Panel SAS-NW |
| 11 | Station HMI [Industrial grade Computer with 23 LED monitor as per specification requirements] With inbuilt storage capacity for Minimum 3Years Substation Data. Antivirus and MS office. |
| 12 | DR workstation [Industrial grade Computer with 23\" LED monitor as per specification] along with Station Data Concentrators Hardware/Software and SFTP client Software to transfer DR files to minimum 3 Remote Control Centre. With inbuilt storage capacity for Minimum 3 Years Substation Data. Antivirus and MS office. |
| 13 | Remote NVR HMI [Industrial grade Computer with 70\" LED monitor as per specification with antivirus] with Network Video recorder Analytic software with inbuilt storage capacity for minimum 30 days of video playback |
| 14 | A3 Size Color Laser Printer |
| 15 | Mono Crome Laser Printer |
| 16 | Remote Workstation(Main and hot standby) with HMI Industrial grade Computer with 23 LED monitor as per specification] With inbuilt storage capacity for Minimum 3 Years Substation Data along with softwares to receive DR files via SFTP from substation. Antivirus and MS office. |
| 17 | Hardware Gateways connected in PRP (for data transmission to SCADA C/R, SLDC )Multi Protocol, multi control centre support with Minimum –Two(2) dedicated Ports for IEC 61850 Communication.Eight(8) dedicated ports for Remote Control Centres on IEC 60870-5-104 protocol.Two(2) dedicated Serial parts for Remote Control Centres on IEC 60870-5-101 protocol. |
| 18 | Modems (both sending and Receiving End) for communication to SCADA C/R & SLDC & Sub SLDC [Specify the Break Up with Quantity and Unit Prices for various items considered for this component of Price Schedule] |
| 19 | Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification [Specify the Break Up with Quantity and Unit Prices for various items considered for this component of Price Schedule] |
| 20 | Ethernet Switches: All Switches shall be Industrial Grade with front LED and Rear Ports and shall have redundant Power Supply and Support native RSTP, SSH2, SNMPv3 and Shall be IEC61850-3 compliant |
| 21 | 132 kV Side C&R: (12 Port (6 Nos. 10/100 Mbps + 6 No. 10/100/1000 Base FX)) connected in PRP |
| 22 | 33 kV Side C&R Panels: (24 Port (18 Nos. 10/100 Mbps +6 No. 10/100/1000 Base FX)} connected in PRP |
| 23 | SAS Switch: {24 Port 10/100 Mbps+ 6 port 10/100/1000 Base FX)] connected in PRP |
| 24 | RCC switch: {8 Port 10/100 Mbps+ 4 port 10/100/1000 Base FX} |
| 25 | Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords, LIU(Line Interface Unit) etc., for completing the substation LAN as per specification requirements. [Specify the Break Up with Quantity and Unit Prices for various items considered for this component] |
| 26 | Inverter(3 kVA Capacity) to be Operatable on 230VAC with Battery as per availability of supply (Normally on AC) for local substation |
| 27 | Inverter(1 kVA Capacity) to be Operatable on 230VAC with Battery as per availability of supply (Normally on AC) for remote substation. |
| 28 | Add: Any other Itam bidder may require to complete the avill C&R Panels and SAS system as per specifiention requirements. |
| 29 | Router cum firewall connected in PRP with min 6 months Iog Storage for Remote Access and sending DR and streaming video recorder feed with minimum 4 ethernet interface. |
| 30 | Auxilliary BCU with sufficient input/output modules and 50% spares for Substation Auxiliary Monitoring Controlling (Battery/ACDB/OLTC/Battery and Tap control, Yard Lightinnig, weather station(temperature, humidity,wind etc.,) along with field transducers and other requied accesories. |
| 31 | MFM for ACDB |
| 32 | Erection AND COMMISSIONING OF Other Associated Items |
| 33 | Modular GPS with Redundant Power Supply, Receiver and Antenna to time Syncronise PRP Network on SNTP and IRIG-B |
| 34 | CCTV(Electronice Surveillance System) |
| 35 | Network video recorder(NVR) |
| 36 | Network based IP bullet (outdoor )Array |
| 37 | SMPS |
| 38 | 16 Port switch |
| 39 | JUNITION BOX 12X10 |
| 40 | Iron Fabricated Pole mounting (CCTV) |
| 41 | LED Monitors32\"\" |
| 42 | MCB single phase 240V 16A |
| 43 | Cat-6 Armored UTP Cable |
| 44 | DISMANTELLING OF EXIXTING OLD C&R PANELS |
| 45 | De-erection of 132KV C&R PANELS |
| 46 | De-erection of 33KV C&R PANELS |
| 47 | De-erection of RTU and telemetry |
| 48 | GST @18% on Schedule A4 |