Tender For Carrying Out Various Electric Works On Semi Turn Key Basis For System Strengthening In Municipal Area In The Area Of Ee, Eudd Ii, Mathura Under The Jurisdiction Of Se, Eudc, Mathura, mathura-Uttar Pradesh

Dakshinanchal Vidyut Vitran Nigam Limited-DVVNL has published Tender For Carrying Out Various Electric Works On Semi Turn Key Basis For System Strengthening In Municipal Area In The Area Of Ee, Eudd Ii, Mathura Under The Jurisdiction Of Se, Eudc, Mathura. Submission Date for this Tender is 08-11-2023. Civil Work Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39898671
Corrigendum : Tender For Carrying Out Various Electric Works On Semi Turn Key Basis For System Strengthening In Municipal Area In The Area Of Ee, Eudd Ii, Mathura Under The Jurisdiction Of Se, Eudc, Mathura
Open Tender
Indian
Uttar Pradesh
mathura
08-11-2023

Tender Details

Tender For Carrying Out Various Electric Works On Semi Turn Key Basis For System Strengthening In Municipal Area In The Area Of Ee, Eudd Ii, Mathura Under The Jurisdiction Of Se, Eudc, Mathura- Cartage Of Following Material From Store Centre, Mathura To Work Site. 2 St Pole ( 11 Mtr. Long ) ( Bottom Portion Galvanized ) 3 Pcc Pole ( 8.5 Mtr. Long ) 4 St Pole Pole ( 13 Mtr. Long ) ( Bottom Portion Galvanized ) 5 11 / 0.43 Kv 400 Kva T / F 6 11 / 0.43 Kv 250 Kva T / F. 7 11 / 0.43 Kv 100 Kva T / F. 8 11 / 0.43 Kv 63 Kva T / F. 9 Lt Aerial Bunch Conductor. 3X120 Sq.Mm. 10 Lt Xlpe Cable Al 1X400 Sq.Mm. 11 Lt Pvc Cable 1X630 Sq.Mm. 12 Lt Pvc Cable 1X400 Sq.Mm. 13 Al Xlpe Cable 1X630 Sq.Mm. 14 Al. Xlpe 1X400 Sqmm. Cable 15 Al. Xlpe 1X240 Sqmm. Cable 16 Lt Pvc Cable 3.5X150sq.Mm. 17 Lt Pvc Cable 3.5X240sq.Mm. 18 Lt Pvc Cable 3.5X70sq.Mm. 19 33 Kv Xlpe Cable 3X300 Sq.Mm. 20 11 Kv Xlpe Cable 3X185 Sq.Mm. 21 11 Kv Xlpe Cable 3X70 Sq.Mm. 22 2Cx10 Sq.Mm. Armoured Cable 23 4X10 Sq.Mm. Armoured Cable With Catenary Arrangement 24 Indoor Cable Jointing Kit I / D 11 Kv 3X185 Sq.Mm. 25 Outdoor Cable Jointing Kit O / D 11 Kv 3X185 Sq.Mm. 26 Straight Through For 11 Kv 3X185 Sq.Mm. 27 Outdoor Cable Jointing Kit O / D 11 Kv 3X70 Sq.Mm. 28 Outdoor Cable Jointing Kit O / D 33 Kv 3X300 Sq.Mm. 29 Acsr Ins. Weasel Conductor 30 Acsr Weasel Conductor 31 Acsr Dog Conductor 32 D.O. Fuse Set For 11 Kv 33 Cartage Of Above Material Like Various Size 33 Kv, 11 Kv Cable, Dog / Weasel Conductor, Jointing Kit, Vaccume Interrupter, Distribution Transformers, St / Pcc Pole, Vcb, Insulator, Disc. Fitting, Control Panel, Pin Insulator, Bus Isolator, Line Isolator, Bus Coupler, Brass Glands, Channel, Clamps Etc. From Store Center, Mathura To Work Site And Dismentled Material From Site To Dvvnl Store. 34 Digging Of Pit & Erection Of New Single Support St Pole ( 13 / 11 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 35 Digging Of Pit & Erection Of New Double Pole Structure St Pole ( 13 / 11 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Sturucture Accessories, Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 36 Earthing Of St / Pcc Pole / Body Earthing Of T / F. By M.S Earth Rod. 37 Providing & Fixing Of Ms Nut, Bolt And WasherS 38 Providing & Painting Of St Pole With Aluminum Paint And Red Oxide. 39 Digging Of Pit & Erection Of Stay Rod With Grouting Cement Sand And Brick Ballast Including Nuzzling, Binding Complete. ( Stay Insulator Providing By Contractor ) 40 Filling & Fixing Of 11 Kv Indoor Type Cable Jointing Kit For 11 Kv 3X185 Sqmm.Xlpe Cable 41 Filling & Fixing Of 11 Kv Outdoor Type Cable Jointing Kit For 11 Kv 3X185 Sqmm.Xlpe Cable 42 Filling & Fixing Of 11 Kv Cable Jointing Kit ( Straoght Through ) For 11 Kv 3X185 Sqmm.Xlpe Cable 43 Filling & Fixing Of 11 Kv Outdoor Type Cable Jointing Kit For 11 Kv 3X70 Sqmm.Xlpe Cable 44 Filling & Fixing Of 33 Kv Indoor Type Cable Jointing Kit For 33 Kv 3X300 Sqmm.Xlpe Cable 45 Sagging Of Weasel / Dog Conductor On Erected Poles. 46 Sagging / Jumpering Of Ins. Weasel / Dog Conductor 47 Digging Of Trenchby Making Pits / Open Trench Method / Hdd Method After Due Survey With The Help Of Utility Detector Of Existing Electrical / Telephonic Cable / And Other Utilites Of Public Utilites Departmentand Laying , Testing, Commisiong & Energization Of Cables Of 33 Kv / 11 Kv Xlpe Double Ckt. Cable By Manual Drill ( By Making Moles ) / Hdd Method / Open Trench Including All Material Like Brick & Sand And Back Filling And Restoring The Road To Make As Original. 48 Sagging & Laying Of 33 / 11 Kv Xlpe Cable In Double Pole Structure / Loop Etc. 49 Laying Of Laying Of2c / 10 Sq.Mm. Armoured Cable 50 Laying Of 4X10 Xlpe Armoured Cable With Catenary Arrange Ment 51 Digging Of Trenchby Making Pits / Open Trench Method / Hdd Method After Due Survey With The Help Of Utility Detector Of Existing Electrical / Telephonic Cable / And Other Utilites Of Public Utilites Departmentand Laying , Testing, Commisiong & Energization Of Cables Of Lt Xlpe / Pvc / Al. Double Ckt. Cable By Manual Drill ( By Making Moles ) / Hdd Method / Open Trench Including All Material Like Brick & Sand And Back Filling And Restoring The Road To Make As Original. 52 Sagging & Laying Of Lt Cable 3.5X150 / 240Sq.Mm. 53 Laying Of Lt Abc 3X120 Sq.Mm. Cable 54 Laying Lt Xlpe Cable Al 1X400 Sq.Mm. 55 Laying Lt Pvc Cable 1X630 Sq.Mm. 56 Laying Lt Pvc Cable 1X400 Sq.Mm. 57 Laying Al Xlpe Cable 1X630 Sq.Mm. 58 Laying Al. Xlpe 1X400 Sqmm. Cable 59 Laying Al. Xlpe 1X240 Sqmm. Cable 60 Guarding Of 33Kv / 11 Kv Line. ( Including G.I. Wire And Other Related Items ) 61 Providing And Fixing Of 11 Kv Holding Clamp For St Pole 62 Providing & Fixing Of G.I. Pipe 4 / 6 Dia 63 Providing & Fixing Of Clamp For G.I. Pipe 64 Providing & Fixing Of Guarding Angle For 33 / 11 Kv 65 Providing & Fixing Of I Bolt For Guarding 66 Providing & Fixing Of Aluminium Biding Wire For Guarding 67 Providing & Fixing Of Clamp For Guarding Angle For 11 Kv Line 68 Providing & Fixing Of Cable End Termination Using Total Double Compression Brass Glands For 3.5X70 Sq.Mm. Xlpe Cable 69 Providing & Fixing Of Cable End Termination Using Total Double Compression Brass Glands For 3.5X150 Sq.Mm. Xlpe Cable 70 Providing & Fixing Ofcable End Termination Using Total Double Compression Brass Glands For 3.5X240 Sq.Mm. Xlpe Cable 71 A-1 Type Distribution Panel With Ats Switch & Controller 800 Amp.Supply &Erectionoffactory Fabricated&Wired Metalcladdustandverminprooffloormounting Double Door Type Outdoor Application, With M.S.Channel Base With Bottom And Top Cable Entries Shall Be Detachable Type Gland Plateelectricalcontrolpanelwithtpnacb ( 65 Ka, 4Pole Elect Draw Out , Micro Processer Release Icu=Icw=Ics 1Sec ) With Short Circuit Protectionand TpnmccbS ( Fourpole50kawith Thermalmagneticrelease With Adjustable Over Current And Short Circuit Protection, Ics=100% Icu, Suitable For 415 V Ac ) Switchesandinstrument Chamber Etc. Complete In All Respects. The Instrument Chamber Shallbeseparate And Incoming Section Connecting With Proper Horizontal / Vertical Busbar And Outgoing Section With Cable Alley Sectionandshall Metering With Digital Multifunction Meter With Inbuilt Selector Switches, Instrument Fuses, Red Yellow And Blue Phase Indicators In Incoming Section, Currenttransformeretc.The Boardshallhave Suitablecapacity Electrolyticaluminumbusbarsas Peris8623insulatedwithheatshrink Color Codesleeveand Mounted On Non Hygroscopic Supports Such As Cmc / Dmc Support With Detachable Side Covers And Shall Be Suitable For Extension On The Sides. The Switches Entryboxesshallbecompletewithsuitablecable End Boxes. ( Incoming : 1250Ampacb1 Noand Outgoing 400 Amp Mccb 6 Nos And 250 Amp Mccb 2 Nos With Extended Rotary Handel, Spreder Set , Phase Barrier Etc ) Theswitchboardshallbe Fabricated With Galvanized Primesheet With A Minimum Thickness Of 1.6 Mm / 2Mm. With Seven Tank Process Powder Coated Switchgear.The Jobincludesthe Disconnecting Anddismantling Of Existing A-1 Type Distribution Panel Including Of Complete Replace Old Burn Cables Ends And Joint New Cable With Cable Jointers, Luges, Double Compression Glands, Etc New Cables Will Joint As Per Connected Sizes In Incoming And Outgoing Sections, The Grounding Ofthe Panel Boardas Per Directionsofengineer-Incharge. 72 A-2 Type Distribution Panel With Ats Switch & Controller 630 Amp.Supply &Erracetionoffactory Fabricated&Wired Metalcladdustandverminprooffloormounting Double Door Type Outdoor Application, With M.S. Channel Base With Bottom And Top Cable Entreis Shall Be Detachable Type Gland Plateelectricalcontrolpanelwith TpnmccbS ( Fourpole50kawith Thermalmagnaticrelease With Adjustable Over Current And Short Circuit Protection, Ics=100% Icu, Suitable For 415 V Ac ) Switchesandinstrument Chamber Etc.Complete In All Respects. The Instrument Chamber Shallbeseparate And Incomming Section Connecting With Proper Horizental / Vertical Busbar And Outgoing Section Cable Alley Sectionandshall Metering With Digital Multifuncation Meter, With Inbuilt Selector Switches, Istrument Fuses, Red Yellow Band Blue Phase Indicators In In Comming Section, Currenttransormeretc.The Boardshallhave Suitablecapacity Electrolyticaluminiumbusbarsas Peris8623insulatedwithheatshrink Color Codesleevand Mounted On Non Hygroscopic Supports Such As Cmc / Dmc Support With Deteachable Side Covers And Shall Be Suitable For Extension On The Sides. The Switches Entryboxesshallbecompletewithsuitablecable End Boxes. Incoming : 800Ampacb 1 Noand Outgoing 400 Amp Mccb 02 Nos., 250 Amp Mccb 05 Nos., 100 Amp Mccb 2 Nos. With Extended Rotary Handel, Spreder Set , Phase Barrier Etctheswitchboardshallbe Fabicated With Gelvnized Primesheet With A Minimum Thickness Of 1.6 Mm / 2Mm. With Seven Tank Process Powder Coated Switchgear Make : Scheinder / Abb / Siemens / C&Sthe Jobincludesthe Disconnecting Anddismentling Of Existing A-2 Type Distribution Panel Including Of Complete Replace Old Burn Cables Ends And Joint New Cable With Cable Jointers, Luges, Double Compression Glands, Etc New Cables Will Joint As Per Connected Sizes In Incoming And Outgoing Sectionsgrounting Ofthe Panel Boardas Per Directionsofengineer-Incharge. 73 A-3 Type Distribution Panel With Ats Switch & Controller 400 Amp.Supply &Erracetionoffactory Fabricated&Wired Metalcladdustandverminprooffloormounting Double Door Type Outdoor Application, With M.S. Channel Base With Bottom And Top Cable Entreis Shall Be Detachable Type Gland Plateelectricalcontrolpanelwith TpnmccbS ( Fourpole50kawith Thermalmagnaticrelease With Adjustable Over Current And Short Circuit Protection, Ics=100% Icu, Suitable For 415 V Ac ) Switchesandinstrument Chamber Etc.Complete In All Respects. The Instrument Chamber Shallbeseparate And Incomming Section Connecting With Proper Horizental / Vertical Busbar And Outgoing Section Cable Alley Sectionandshall Metering With Digital Multifuncation Meter, With Inbuilt Selector Switches, Istrument Fuses, Red Yellow Band Blue Phase Indicators In In Comming Section, Currenttransormeretc.The Boardshallhave Suitablecapacity Electrolyticaluminiumbusbarsas Peris8623insulatedwithheatshrink Color Codesleevand Mounted On Non Hygroscopic Supports Such As Cmc / Dmc Support With Deteachable Side Covers And Shall Be Suitable For Extension On The Sides. The Switches Entryboxesshallbecompletewithsuitablecable End Boxes. Incoming : 630Ampacb- 1 Noand Outgoing 250 Amp Mccb 5 Nos And 100 Amp Mccb 2 Nos With Extended Rotary Handel, Spreder Set , Phase Barrier Etctheswitchboardshallbe Fabicated With Gelvnized Primesheet With A Minimum Thickness Of 1.6 Mm / 2Mm. With Seven Tank Process Powder Coated Switchgear Make : Scheinder / Abb / Siemens / C&Sthe Jobincludesthe Disconnecting Anddismentling Of Existing A-3 Type Distribution Panel Including Of Complete Replace Old Burn Cables Ends And Joint New Cable With Cable Jointers, Luges, Double Compression Glands, Etc New Cables Will Joint As Per Connected Sizes In Incoming And Outgoing Sectionsgrounting Ofthe Panel Boardas Per Directionsofengineer-Incharge. 74 B-3 Type Distribution Panel With Ats Switch & Controller 250 Amp.Supply &Erracetionoffactory Fabricated&Wired Metalcladdustandverminprooffloormounting Double Door Type Outdoor Application, With M.S. Channel Base With Bottom And Top Cable Entreis Shall Be Detachable Type Gland Plateelectricalcontrolpanelwith TpnmccbS ( Fourpole50kawith Thermalmagnaticrelease With Adjustable Over Current And Short Circuit Protection, Ics=100% Icu, Suitable For 415 V Ac ) Switchesandinstrument Chamber Etc.Complete In All Respects. The Instrument Chamber Shallbeseparate And Incomming Section Connecting With Proper Horizental / Vertical Busbar And Outgoing Section Cable Alley Sectionandshall Metering With Digital Multifuncation Meter, With Inbuilt Selector Switches, Istrument Fuses, Red Yellow Band Blue Phase Indicators In In Comming Section, Currenttransormeretc.The Boardshallhave Suitablecapacity Electrolyticaluminiumbusbarsas Peris8623insulatedwithheatshrink Color Codesleevand Mounted On Non Hygroscopic Supports Such As Cmc / Dmc Support With Deteachable Side Covers And Shall Be Suitable For Extension On The Sides. The Switches Entryboxesshallbecompletewithsuitablecable End Boxes.Incoming : 250 Ampmccb1 Noand Outgoing 100 Amp Mccb 04 Nos With Extended Rotary Handel, Spreder Set , Phase Barrier Etctheswitchboardshallbe Fabicated With Gelvnized Primesheet With A Minimum Thickness Of 1.6 Mm / 2Mm. With Seven Tank Process Powder Coated Switchgear Switchgear Make : Scheinder / Abb / Siemens / C&Sthe Jobincludesthe Disconnecting Anddismentling Of Existing B-3 Type Distribution Panel Including Of Complete Replace Old Burn Cables Ends And Joint New Cable With Cable Jointers, Luges, Double Compression Glands, Etc New Cables Will Joint As Per Connected Sizes In Incoming And Outgoing Sectionsgrounting Ofthe Panel Boardas Per Directionsofengineer-Incharge. 75 C Paneldisconeccting And Dismentlingof Existing C Panel And Supply, Installation Testing Commisioning Offactory Fabricated&Wired Metalcladdustandverminproof Double Door Typeoutdoor Application Stand Mounting, M.S. Channel Base Incliding Channel Stand With Bottom Cable Entreis The Panel Boardshall Havesuitablecapacity Electrolytic Alumininum Busbars Asper Is8623 Or Above Istulated With Heat Shrink Sleeving And Mounted On Nonhygroscopic Supports Such As Cmc / Bmc Support. Panel Shall Be Completewithsuitablecableendboxes, Double Compression Glands. Panel Comparment Having Special Provision For Internal Locking System For Stop The Electricity Theft The Panelboard Shall Be Fabricated With Gelvnized Prime Sheet With A Minimum Thickness Of 1.6Mm / 2Mm. With Seven Tank Process Powder Coated. Panel Haveing Proper Space For Connectingincomming And Outgoing Cable Terminations Make: Apc / Scheinder / Abb / Siemens / C&S & Complete With Insulation Of Bakelite Strip ( 08 Mm / 10 Mm ) Thickness. 76 Earthing Complete For C Type Panels By Earth Rod 77 Providing & Fixing Of Lt Acb 800 Amp Nos. 250 Amp. Output Mccb And Suitable Covering & Mounting Strucuture 78 Providing & Fixing Of Lt Acb 630 Amp Nos. 250 Amp. Output Mccb And Suitable Covering & Mounting Strucuture 79 Providing & Fixing Of Foundation Of Rmu 3 Cubic Meter 80 Pipe And Pipe Gel Earthing For R.M.U 81 Providing & Fixing Of Danger Board 82 Providing & Fixing Of Barbed Wire 83 Sagging Of Guarding G.I. Wire 84 Providing & Fixing Of Stone Pad 85 Providing & Fixing Of Boot Protection For T / F Monkey Fault 86 Providing & Fixing 16 Sqmm. Alumimum Thimble 87 Providing & Fixing Of Pvc Pipe 3 Of Diameter 88 Providing And Instllation Of 24 Volt Battery With Charger. 89 Providing & Fixing Of 33 Kv V Type Steel Cross Arm 90 Provoding & Fixing Of 11 Kv V Type Steel Cross Arm 91 Providing & Fixing Of 11 Kv Pin Insulator With Pin 92 Providing & Fixing Of 33 Kv V Type Steel Cross Arm Holding Clamp 93 Providing & Fixing Of 11 Kv V Type Steel Cross Arm Holding Clamp 94 Providing & Fixing Of 33 Kv Pin Insulator With Pin 95 Providing & Fixing Of Disc Insulator 45 Kn & 70 Kn ( T&C / B&S ) With Fitting 96 Providing & Fixing Of 33 Kv F Bracket 97 Providing & Fixing Of 11 Kv F Bracket 98 Providing & Fixing Of Packing Piece Clamp For 33 Kv / 11 Kv With Nut & Bolts 99 Providing & Fixing Of Aluminium Lug 25 Sqmm. 100 Providing & Fixing Of Aluminium Lug 70 Sqmm. 101 Providing & Fixing Of Aluminium Lug 150 Sqmm. 102 Providing & Fixing Of Aluminium Lug 240 Sqmm. 103 Providing & Fixing Of Aluminium Lug 400 Sqmm. 104 Providing & Fixing Of Aluminium Lug 630 Sqmm. 105 Providing & Fixing Of Aluminium Lug 1000 Sqmm. 106 Providing & Sagging / Fixing Of Al. Xlpe 1X1000 Sq.Mm. Cable 107 Installation Of 11 / 0.4 Kv, 400 Kva T / F Mobile Trolley 108 Providng Trolley Structure For 400 Kva T / F With Vehicle Tyre, Rim, Coupling, Trolly Hook, Earthing, Painting And Related Accessories With Complete Job 109 Supply Of G.I. Pipe Chemicalearthing Electrode 3 Mtr. Long 80 Mm Inner Dia Along With Chemical Powder And 50X6 Mm G.I. Strip With Nut, Bolt And Washer. 110 Earthing Of Power Transformer ( Urban ) By Digging Of Pit Up To Water Level Depth Approx. 90 Feet. Into The Boring 1-1 / 4 Dia Gi Pipe Of B Grade, Conforming To The Requirement Of Is Specification And Then Connecting The Top Of The Inserted Pipe And Power Transformer Body Earthing Through M.S. Strip Of Size 50X6mm With The Help Of Electric Welding Lum Sum Rate. It Includes The Cost Of All Material, Labour, Carrier Etc. Required For Proper Completion Of Work. 111 Installation Of D.O. Fuse Set Of 11 Kv 112 Supply, Install, Testing And Commisioning Of 11 Kv 630 Amps 21 Ka For 3 Sec. Sf6 Insulated, One Side Extesible, Outdoor Duty 3 Way R.M.U. Manual Operate, In Combination Of 01 Nos. Vcb Modules ( O / G ) & 2 Nos. Load Breakerswitch Modules ( I / C ) , Consitiing Of Copper Busbar In Sf6 Insulated 304 ( Non-Ferrite Non-Magnetic Grade ) Stainless Steel Enclosure Of Thickness 2.5 Mm With Manometer Fixed On The Tank. The Breaker Shall Have Mechanical On / Off Indicator With Hand Trip Device And Spring Charging, Spring Relase Coil, Auxiliary Switch Of 02 No +2Nc. The Hv Switchgerar And Control Gear Should Be Confirming To Iec-62271-100, Iec-62271-200-2003 & Iec-60694-1996. The Rmu Gas Tank Should Be Internal Arc Tested For 21 Ka For 1Second With Iac-Afl Classification For Gas Tank. The Complete Rmu Should Have Ingress Protection Of Minimum Ip54. The Rmu Design Should Support Site Replaceable Ht Cable Bushing. All The Type Test Certified As Per Iec From Third Party Lab To Be Submitted. Rmu Should Have :- 01 Nos. Micorprocessor Based Self Powered Numerical Relay With Over Current / Earth Fault & Short Circuit Protection Wiht Each Vcb Feeder. - 3Nos. Protection Ct Shall Be Of Burden 2.5 Va, Ratio 200 / 1A, Class Of Accuracy Class 5P10 For O / C And E / F Protection For Each Vcb. ( Ct Ration Is Indicative And May Vary During Detailed Engineering ) -1 No. Manometer For Each Tank-1 Nos. Voltage Passage Indicator For Each Feeder. -1 Nos. Fault Passage Indicator For Each Lbs Module.- Right Angle Boots For All The Feeder Modules- Basic Insulation Level Of Complete System Shall Be 28Kv ( Rms ) / 75Kv ( Peak ) - Vacuum Interrupter & Rmu Should Be Of Same Make For Better Life Cycle Optimization. 113 Supply, Install, Testing And Commisioning Of 11 Kv 630 Amps 21 Ka For 3 Sec. Sf6 Insulated, One Side Extesible, Outdoor Duty 4 Way R.M.U. Manual Operate, In Combination Of 02 Nos. Vcb Modules ( O / G ) & 2 Nos. Load Breakerswitch Modules ( I / C ) , Consitiing Of Copper Busbar In Sf6 Insulated 304 ( Non-Ferrite Non-Magnetic Grade ) Stainless Steel Enclosure Of Thickness 2.5 Mm With Manometer Fixed On The Tank. The Breaker Shall Have Mechanical On / Off Indicator With Hand Trip Device And Spring Charging, Spring Relase Coil, Auxiliary Switch Of 02 No +2Nc. The Hv Switchgerar And Control Gear Should Be Confirming To Iec-62271-100, Iec-62271-200-2003 & Iec-60694-1996. The Rmu Gas Tank Should Be Internal Arc Tested For 21 Ka For 1Second With Iac-Afl Classification For Gas Tank. The Complete Rmu Should Have Ingress Protection Of Minimum Ip54. The Rmu Design Should Support Site Replaceable Ht Cable Bushing. All The Type Test Certified As Per Iec From Third Party Lab To Be Submitted. Rmu Should Have :- 01 Nos. Micorprocessor Based Self Powered Numerical Relay With Over Current / Earth Fault & Short Circuit Protection Wiht Each Vcb Feeder. - 3Nos. Protection Ct Shall Be Of Burden 2.5 Va, Ratio 500 / 1A, Class Of Accuracy Class 5P10 For O / C And E / F Protection For Each Vcb. ( Ct Ration Is Indicative And May Vary During Detailed Engineering ) -1 No. Manometer For Each Tank-1 Nos. Voltage Passage Indicator For Each Feeder. -1 Nos. Fault Passage Indicator For Each Lbs Module.- Right Angle Boots For All The Feeder Modules- Basic Insulation Level Of Complete System Shall Be 28Kv ( Rms ) / 75Kv ( Peak ) - Vacuum Interrupter & Rmu Should Be Of Same Make For Better Life Cycle Optimization. 114 Supply, Install, Testing And Commisioning Of 11 Kv 630 Amps 21 Ka For 3 Sec. Sf6 Insulated, One Side Extesible, Outdoor Duty 5 Way R.M.U. Manual Operate, In Combination Of 03 Nos. Vcb Modules ( O / G ) & 2 Nos. Load Breakerswitch Modules ( I / C ) , Consitiing Of Copper Busbar In Sf6 Insulated 304 ( Non-Ferrite Non-Magnetic Grade ) Stainless Steel Enclosure Of Thickness 2.5 Mm With Manometer Fixed On The Tank. The Breaker Shall Have Mechanical On / Off Indicator With Hand Trip Device And Spring Charging, Spring Relase Coil, Auxiliary Switch Of 02 No +2Nc. The Hv Switchgerar And Control Gear Should Be Confirming To Iec-62271-100, Iec-62271-200-2003 & Iec-60694-1996. The Rmu Gas Tank Should Be Internal Arc Tested For 21 Ka For 1Second With Iac-Afl Classification For Gas Tank. The Complete Rmu Should Have Ingress Protection Of Minimum Ip54. The Rmu Design Should Support Site Replaceable Ht Cable Bushing. All The Type Test Certified As Per Iec From Third Party Lab To Be Submitted. Rmu Should Have :- 01 Nos. Micorprocessor Based Self Powered Numerical Relay With Over Current / Earth Fault & Short Circuit Protection Wiht Each Vcb Feeder. - 3Nos. Protection Ct Shall Be Of Burden 2.5 Va, Ratio 500 / 1A, Class Of Accuracy Class 5P10 For O / C And E / F Protection For Each Vcb. ( Ct Ration Is Indicative And May Vary During Detailed Engineering ) -1 No. Manometer For Each Tank-1 Nos. Voltage Passage Indicator For Each Feeder. -1 Nos. Fault Passage Indicator For Each Lbs Module.- Right Angle Boots For All The Feeder Modules- Basic Insulation Level Of Complete System Shall Be 28Kv ( Rms ) / 75Kv ( Peak ) - Vacuum Interrupter & Rmu Should Be Of Same Make For Better Life Cycle Optimization. 115 Supply &Erection Offactory Fabricated&Wired Metalcladdustandverminprooffloormounting Double Door Type Outdoor Application, With M.S. Channel Base With Bottom And Top Cable Entreis Shall Be Detachable Type Gland Plateelectricalcontrolpanelwith 01 No. 630 Amp. Acb& 03 No. 250 Amp. Mccb The Instrument Chambershallbeseparate And Incomming Section Connecting With Proper Horizental / Vertical Busbar And Outgoing Section With Cable Alley Sectionandshall Metering With Digital Multifuncation Meter With Inbuilt Selector Switches, Istrument Fuses, Red Yellow And Blue Phase Indicators In Incomming Section, Currenttransormeretc.The Boardshallhave Suitablecapacity Electrolyticaluminiumbusbarsinsulatedwithheatshrink Color Codesleevand Mounted On Non Hygroscopic Supports Such As Cmc / Dmc Support With Deteachable Side Covers And Shall Be Suitable For Extension On The Sides. The Switches Entryboxesshallbecompletewithsuitablecable End Boxestheswitchboardshallbe Fabicated With Gelvnized Primesheet With A Minimum Thickness Of 1.6 Mm / 2Mm. With Seven Tank Process Powder Coated 116 Supply &Erection Offactory Fabricated&Wired Metalcladdustandverminprooffloormounting Double Door Type Outdoor Application, With M.S. Channel Base With Bottom And Top Cable Entreis Shall Be Detachable Type Gland Plateelectricalcontrolpanelwith 01 No. 800 Amp. Acb& 01 No. 400 Amp. Mccb & 02 No. 250 Amp. Mccbthe Instrument Chambershallbeseparate And Incomming Section Connecting With Proper Horizental / Vertical Busbar And Outgoing Section With Cable Alley Sectionandshall Metering With Digital Multifuncation Meter With Inbuilt Selector Switches, Istrument Fuses, Red Yellow And Blue Phase Indicators In Incomming Section, Currenttransormeretc.The Boardshallhave Suitablecapacity Electrolyticaluminiumbusbarsinsulatedwithheatshrink Color Codesleevand Mounted On Non Hygroscopic Supports Such As Cmc / Dmc Support With Deteachable Side Covers And Shall Be Suitable For Extension On The Sides. The Switches Entryboxesshallbecompletewithsuitablecable End Boxestheswitchboardshallbe Fabicated With Gelvnized Primesheet With A Minimum Thickness Of 1.6 Mm / 2Mm. With Seven Tank Process Powder Coated 117 Supply &Erection Offactory Fabricated&Wired Metalcladdustandverminprooffloormounting Double Door Type Outdoor Application, With M.S. Channel Base With Bottom And Top Cable Entreis Shall Be Detachable Type Gland Plateelectricalcontrolpanelwith 01 No. 1250 Amp. Acb, 02 No. 400 Amp. Mccb & 02 No. 250 Amp. Mccbthe Instrument Chambershallbeseparate And Incomming Section Connecting With Proper Horizental / Vertical Busbar And Outgoing Section With Cable Alley Sectionandshall Metering With Digital Multifuncation Meter With Inbuilt Selector Switches, Istrument Fuses, Red Yellow And Blue Phase Indicators In Incomming Section, Currenttransormeretc.The Boardshallhave Suitablecapacity Electrolyticaluminiumbusbarsinsulatedwithheatshrink Color Codesleevand Mounted On Non Hygroscopic Supports Such As Cmc / Dmc Support With Deteachable Side Covers And Shall Be Suitable For Extension On The Sides. The Switches Entryboxesshallbecompletewithsuitablecable End Boxestheswitchboardshallbe Fabicated With Gelvnized Primesheet With A Minimum Thickness Of 1.6 Mm / 2Mm. With Seven Tank Process Powder Coated 118 Providing & Fixing Of Dead End Clamp With I-Hook 119 Providing & Fixing Of Suspension Clamp With I- Hook 120 Providing & Fixing Of Piercing Clamp 121 Installation Of Lt Distribution Box 122 Providing & Fixing Of Pvc Pipe 2 Of Diameter 123 Providing & Fixing Of Clamp For Distribution Box 124 Concreting Of Pole ( St 13 Mtr. / 11 Mtr. ) Pcc Pole 125 Providing And Fixing / Installation Of Compact Substation T / F Of 400 Kva Including All Relevant And Required Accessories. 126 Removal Of Old Transformer ( 250 Kva ) With All Connected Accessories From Existing Double Pole. 127 Removal Of Old Transformer ( 100 Kva ) With All Connected Accessories From Existing Double Pole. 128 Removal Of Old Transformer ( 63Kva ) With All Connected Accessories From Existing Double Pole. 129 Removal Of Old Transformer ( 25Kva ) With All Connected Accessories From Existing Double Pole. 130 Construction Of Plinth 6X6x4 Height From Ground As Per Sc ( As Per Approved Gtp ) 131 Installation Of Following Transformer On Plinth / Double Pole With All Connecting Accessories Jumering Etc. Including Carriage Of Transformers From Store Centre, Mathura To Work Site. 132 400 Kva Transformer On Plinth 133 250 Kva Transformer On Plinth 134 100 Kva Transformer On Double Pole 135 63 Kva Transformer On Double Pole 136 Providing And Installation Of Tail Less Unit Complete 137 Mash / Frp Fencing Of Sub-Station With Civil Works ( As Per Approved Gtp ) 138 Complete Pipe In Pipe Gel Earthing Of 11 / 0.4 Kv 250 / 400 Distribution Transformer By Digging Pits 6” Dia Upto 3 Mtr. Deep Including Chemical Filled Pipe In Between ( Pipe-In-Pipe ) Isi Mark B Grade & Connecting With G.I Strip Of Size 50Mm X 6Mm With Neutral / Body Of 11 / 0.4 Kv Distribution Transformer To Above Pipe-In-Pipe ( Pip ) And Filling Of Chemical Crystalline Conductive Mixture Containing Highly Conductive Material Around The ( Pipe-In-Pipe ) Up To 3 Mtr. Including Making Of Chamber At The Top Of The Earthing. Other Details Are As Below:-1.Earth Pipe Material – Mild Steel, Galvanised.2-Main Electrode Diameter – 42.4Mm.3-Auxiliary Electrode Pipe, Diameter – 76Mm.4-Wall Thickness Of Main Electrode :- 2.6Mm.5-Wall Thickness Of Auxiliary Ist Whole:- 3.2Mm.6- Length Of Earthing Electrode ( Pip ) :- 3 Meter. 139 Dismantling Of Damaged & Used Items I.E. Distribution Transformer, St / Pcc Pole, Ht / Lt Cable, Conductor ( Scrap ) & Other Accessories At Work Site And Carriage Dismantled Material From Site To Store Center, Mathura. 140 Proper Road Restoration Kaccha / Pakka ( If Required ) Rates Shall Be Acceptable, If Not Given Above For The Same Work.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Oct-2023 CORRIGENDUM 1 Date 04-10-2023
2 01-Oct-2023 CORRIGENDUM Financial Bid 04-10-2023
3 04-Oct-2023 Corrigendum 2 Date 09-10-2023
4 09-Oct-2023 CORRIGENDUM 3 Date 12-10-2023
5 12-Oct-2023 CORRIGENDUM 4 Date 16-10-2023
6 16-Oct-2023 CORRIGENDUM 6 Date 18-10-2023
7 18-Oct-2023 CORRIGENDUM 7 Date 21-10-2023
8 21-Oct-2023 CORRIGNDUM 8 Date 25-10-2023
9 25-Oct-2023 CORRIGENDUM 8 Date 28-10-2023
10 28-Oct-2023 CORRIGENDUM 9 Date 31-10-2023
11 31-Oct-2023 Corrigendum 10 Date 03-11-2023
12 03-Nov-2023 CORRIGENDUM 11 Date 06-11-2023
13 06-Nov-2023 CORRIGENDUM 12 Date 08-11-2023

Key Value

Document Fees
INR 5000 /-
EMD
INR 700000.0 /-
Tender Value
INR 6.23 Crore /-

BOQ Items

Name of Work : Carrying out various electric works on Semi Turn-key Basis for system strengthening in Municipal area in the area of EE, EUDD-II, Mathura under the jurisdiction of SE, EUDC, Mathura.
Sl. No. Item Description
1Cartage of following material from Store centre, Mathura to work site.
2ST Pole (11 mtr. Long) (Bottom Portion Galvanized)
3PCC Pole (8.5 mtr. Long)
4ST Pole Pole (13 mtr. Long) (Bottom Portion Galvanized)
511/0.43 KV 400 KVA T/F
611/0.43 KV 250 KVA T/F.
711/0.43 KV 100 KVA T/F.
811/0.43 KV 63 KVA T/F.
9LT Aerial Bunch conductor. 3x120 Sq.mm.
10LT XLPE cable AL 1X400 sq.mm.
11LT PVC cable 1x630 sq.mm.
12LT PVC cable 1x400 sq.mm.
13AL XLPE cable 1x630 sq.mm.
14AL. XLPE 1X400 sqmm. Cable
15AL. XLPE 1X240 sqmm. Cable
16LT PVC cable 3.5x150sq.mm.
17LT PVC cable 3.5x240sq.mm.
18LT PVC cable 3.5x70sq.mm.
1933 KV XLPE Cable 3x300 Sq.mm.
2011 KV XLPE Cable 3x185 Sq.mm.
2111 KV XLPE Cable 3x70 Sq.mm.
222Cx10 Sq.mm. armoured cable
234x10 Sq.mm. armoured cable with catenary arrangement
24Indoor Cable Jointing Kit I/D 11 KV 3x185 Sq.mm.
25Outdoor Cable Jointing Kit O/D 11 KV 3x185 Sq.mm.
26Straight Through for 11 KV 3x185 Sq.mm.
27Outdoor Cable Jointing Kit O/D 11 KV 3x70 Sq.mm.
28Outdoor Cable Jointing Kit O/D 33 KV 3x300 Sq.mm.
29ACSR Ins. Weasel conductor
30ACSR Weasel conductor
31ACSR Dog conductor
32D.O. Fuse Set for 11 KV
33Cartage of above material like various size 33 KV, 11 kv cable, dog/weasel conductor, Jointing kit, vaccume interrupter, distribution transformers, ST/PCC Pole, VCB, insulator, Disc. fitting, control panel, pin insulator, bus isolator, Line isolator, Bus coupler, brass glands, channel, clamps etc. from Store Center, Mathura to work site and dismentled material from site to dvvnl store.
34Digging of pit & erection of new single support ST Pole (13/11 mtr. long) including grouting of pole and fixing of all clamps, cross arm, pin/disc insulator & other accessories with providing stone pad as per relevant drawings. Any fabrication if required for above support.
35Digging of pit & erection of new Double Pole Structure ST Pole (13/11 mtr. long) including grouting of pole and fixing of all Sturucture accessories, clamps, cross arm, pin/disc insulator & other accessories with providing stone pad as per relevant drawings. Any fabrication if required for above support.
36Earthing of ST/PCC pole/Body earthing of T/F. by M.S earth rod.
37Providing & fixing of MS Nut, Bolt and Washer"s
38Providing & Painting of ST pole with aluminum paint and Red oxide.
39Digging of pit & erection of Stay rod with grouting cement sand and brick ballast including Nuzzling, binding Complete. (Stay Insulator providing by contractor)
40Filling & Fixing of 11 KV Indoor type cable Jointing Kit for 11 KV 3x185 sqmm.XLPE cable
41Filling & Fixing of 11 KV Outdoor type cable Jointing Kit for 11 KV 3x185 sqmm.XLPE cable
42Filling & Fixing of 11 KV cable Jointing Kit (Straoght Through) for 11 KV 3x185 sqmm.XLPE cable
43Filling & Fixing of 11 KV Outdoor type cable Jointing Kit for 11 KV 3x70 sqmm.XLPE cable
44Filling & Fixing of 33 KV Indoor type cable Jointing Kit for 33 KV 3x300 sqmm.XLPE cable
45Sagging of Weasel/Dog conductor on erected poles.
46Sagging/Jumpering of Ins. Weasel/Dog conductor
47Digging of trenchby Making pits/open trench method/HDD method after due survey with the help of utility detector of existing electrical/telephonic cable/and other utilites of public utilites departmentand laying , Testing, Commisiong & energization of cables of 33 KV/11 kv XLPE double ckt. Cable by manual drill (by making moles) /HDD method/ open trench Including all material Like brick & sand and Back filling and restoring the road to make as original.
48Sagging & Laying of 33/11 KV XLPE cable in Double Pole structure/Loop etc.
49Laying of Laying of2c/10 sq.mm. armoured Cable
50Laying of 4X10 XLPE armoured Cable With Catenary arrange ment
51Digging of trenchby Making pits/open trench method/HDD method after due survey with the help of utility detector of existing electrical/telephonic cable/and other utilites of public utilites departmentand laying , Testing, Commisiong & energization of cables of LT XLPE/PVC/Al. double ckt. Cable by manual drill (by making moles) /HDD method/ open trench Including all material Like brick & sand and Back filling and restoring the road to make as original.
52Sagging & Laying of LT cable 3.5x150/240sq.mm.
53Laying of LT ABC 3X120 sq.mm. Cable
54Laying LT XLPE cable AL 1X400 sq.mm.
55Laying LT PVC cable 1x630 sq.mm.
56Laying LT PVC cable 1x400 sq.mm.
57Laying AL XLPE cable 1x630 sq.mm.
58Laying AL. XLPE 1X400 sqmm. Cable
59Laying AL. XLPE 1X240 sqmm. Cable
60Guarding of 33KV/11 KV line. (including G.I. Wire and other related items)
61Providing and Fixing of 11 KV Holding Clamp For ST Pole
62Providing & fixing of G.I. Pipe 4"/6" dia
63Providing & fixing of Clamp For G.I. Pipe
64Providing & fixing of Guarding Angle for 33/11 KV
65Providing & fixing of I Bolt for Guarding
66Providing & fixing of Aluminium Biding Wire for Guarding
67Providing & fixing of clamp for guarding angle for 11 KV line
68Providing & Fixing of Cable end termination using total double compression brass glands for 3.5x70 sq.mm. XLPE Cable
69Providing & Fixing of Cable end termination using total double compression brass glands for 3.5x150 sq.mm. XLPE Cable
70Providing & Fixing ofCable end termination using total double compression brass glands for 3.5x240 sq.mm. XLPE Cable
71A-1 Type Distribution Panel with ATS Switch & Controller 800 Amp. Supply &Erectionoffactory fabricated&wired metalcladdustandverminprooffloormounting double door type outdoor application, with M.S.Channel Base with bottom and top cable entries shall be detachable type gland plateElectricalcontrolpanelwithTPNACB(65 KA,4Pole Elect draw out , Micro processer Release icu=icw=ics 1sec) with short circuit protectionand TPNMCCB"s(FourPole50KAwith thermalmagneticrelease with Adjustable Over Current and Short Circuit Protection, Ics=100% Icu, suitable for 415 V AC)Switchesandinstrument chamber etc. complete in all respects. The instrument chamber shallbeseparate and incoming section connecting with proper horizontal /vertical busbar and outgoing section with cable alley sectionandshall metering with digital multifunction meter with inbuilt Selector switches,instrument fuses, red yellow and blue phase indicators in incoming section, currenttransformeretc.The Boardshallhave suitablecapacity electrolyticaluminumbusbarsas perIS8623insulatedwithheatshrink color codesleeveand mounted on non hygroscopic supports such as CMC/ DMC support with detachable side covers and shall be suitable for extension on the sides. The switches entryboxesshallbecompletewithsuitablecable end boxes. (INCOMING : 1250AmpACB1 Noand OUTGOING 400 AMP MCCB 6 NOS AND 250 AMP MCCB 2 NOS WITH EXTENDED ROTARY HANDEL,SPREDER SET ,PHASE BARRIER etc) Theswitchboardshallbe fabricated with galvanized primesheet with a minimum thickness of 1.6 mm/2mm. with seven tank process powder coated SWITCHGEAR. The Jobincludesthe disconnecting anddismantling of existing A-1 type distribution panel including of complete replace old burn cables ends and joint new cable with cable jointers, luges, double compression glands, etc new cables will joint as per connected sizes in incoming and outgoing sections, the grounding ofthe panel boardas per directionsofEngineer-incharge.
72A-2 Type Distribution Panel with ATS Switch & Controller 630 Amp. Supply &Erracetionoffactory fabricated&wired metalcladdustandverminprooffloormounting double door type outdoor application,with M.S. Channel Base with bottom and top cable entreis shall be detachable type gland plateElectricalcontrolpanelwith TPNMCCB"s(FourPole50KAwith thermalmagnaticrelease with Adjustable Over Current and Short Circuit Protection, Ics=100% Icu, suitable for 415 V AC)Switchesandinstrument chamber etc.complete in all respects. The instrument chamber shallbeseparate and incomming section connecting with proper horizental /vertical busbar and outgoing section cable alley sectionandshall metering with digital multifuncation meter, with inbuilt Selector switches,istrument fuses, red yellow band blue phase indicators in in comming section, currenttransormeretc.The Boardshallhave suitablecapacity electrolyticaluminiumbusbarsas perIS8623insulatedwithheatshrink color codesleevand mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entryboxesshallbecompletewithsuitablecable end boxes. INCOMING : 800AmpACB 1 Noand OUTGOING 400 AMP MCCB 02 Nos., 250 AMP MCCB 05 Nos., 100 AMP MCCB 2 Nos. WITH EXTENDED ROTARY HANDEL,SPREDER SET ,PHASE BARRIER etcTheswitchboardshallbe fabicated with gelvnized primesheet with a minimum thickness of 1.6 mm/2mm. with seven tank process powder coated SWITCHGEAR MAKE : SCHEINDER/ABB/SIEMENS/C&S The Jobincludesthe disconnecting anddismentling of existing A-2 type distribution panel including of complete replace old burn cables ends and joint new cable with cable jointers, luges, double compression glands,etc new cables will joint as per connected sizes in incoming and outgoing sectionsgrounting ofthe panel boardas per directionsofEngineer-incharge.
73A-3 Type Distribution Panel with ATS Switch & Controller 400 Amp. Supply &Erracetionoffactory fabricated&wired metalcladdustandverminprooffloormounting double door type outdoor application,with M.S. Channel Base with bottom and top cable entreis shall be detachable type gland plateElectricalcontrolpanelwith TPNMCCB"s(FourPole50KAwith thermalmagnaticrelease with Adjustable Over Current and Short Circuit Protection, Ics=100% Icu, suitable for 415 V AC)Switchesandinstrument chamber etc.complete in all respects. The instrument chamber shallbeseparate and incomming section connecting with proper horizental /vertical busbar and outgoing section cable alley sectionandshall metering with digital multifuncation meter, with inbuilt Selector switches,istrument fuses, red yellow band blue phase indicators in in comming section, currenttransormeretc.The Boardshallhave suitablecapacity electrolyticaluminiumbusbarsas perIS8623insulatedwithheatshrink color codesleevand mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entryboxesshallbecompletewithsuitablecable end boxes. INCOMING : 630AmpACB- 1 Noand OUTGOING 250 AMP MCCB 5 NOS AND 100 AMP MCCB 2 NOS WITH EXTENDED ROTARY HANDEL,SPREDER SET ,PHASE BARRIER etcTheswitchboardshallbe fabicated with gelvnized primesheet with a minimum thickness of 1.6 mm/2mm. with seven tank process powder coated SWITCHGEAR MAKE : SCHEINDER/ABB/SIEMENS/C&S The Jobincludesthe disconnecting anddismentling of existing A-3 type distribution panel including of complete replace old burn cables ends and joint new cable with cable jointers, luges, double compression glands,etc new cables will joint as per connected sizes in incoming and outgoing sectionsgrounting ofthe panel boardas per directionsofEngineer-incharge.
74B-3 Type Distribution Panel with ATS Switch & Controller 250 Amp. Supply &Erracetionoffactory fabricated&wired metalcladdustandverminprooffloormounting double door type outdoor application,with M.S. Channel Base with bottom and top cable entreis shall be detachable type gland plateElectricalcontrolpanelwith TPNMCCB"s(FourPole50KAwith thermalmagnaticrelease with Adjustable Over Current and Short Circuit Protection, Ics=100% Icu, suitable for 415 V AC)Switchesandinstrument chamber etc.complete in all respects. The instrument chamber shallbeseparate and incomming section connecting with proper horizental /vertical busbar and outgoing section cable alley sectionandshall metering with digital multifuncation meter, with inbuilt Selector switches,istrument fuses, red yellow band blue phase indicators in in comming section, currenttransormeretc.The Boardshallhave suitablecapacity electrolyticaluminiumbusbarsas perIS8623insulatedwithheatshrink color codesleevand mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entryboxesshallbecompletewithsuitablecable end boxes.INCOMING : 250 AmpMCCB1 Noand OUTGOING 100 AMP MCCB 04 NOS WITH EXTENDED ROTARY HANDEL,SPREDER SET ,PHASE BARRIER etcTheswitchboardshallbe fabicated with gelvnized primesheet with a minimum thickness of 1.6 mm/2mm. with seven tank process powder coated switchgear SWITCHGEAR MAKE : SCHEINDER/ABB/SIEMENS/C&S The Jobincludesthe disconnecting anddismentling of existing B-3 type distribution panel including of complete replace old burn cables ends and joint new cable with cable jointers, luges, double compression glands,etc new cables will joint as per connected sizes in incoming and outgoing sectionsgrounting ofthe panel boardas per directionsofEngineer-incharge.
75C Panel Disconeccting and dismentlingof existing C panel and Supply,installation testing commisioning offactory fabricated&wired metalcladdustandverminproof double door typeoutdoor application stand mounting, M.S. Channel Base incliding channel stand with bottom cable entreis The panel boardshall havesuitablecapacity electrolytic alumininum busbars asper IS8623 or above istulated with heat shrink sleeving and mounted on nonhygroscopic supports such as CMC/BMC support. panel shall be completewithsuitablecableendboxes, double compression glands. panel comparment having special provision for internal locking system for stop the electricity theft The panelboard shall be fabricated with gelvnized prime sheet with a minimum thickness of 1.6mm/2mm. with seven tank process powder coated. panel haveing proper space for connectingincomming and outgoing cable terminations MAKE: APC/SCHEINDER/ABB/SIEMENS/C&S & Complete with insulation of bakelite strip(08 mm/10 mm) thickness.
76Earthing Complete for C Type Panels by earth rod
77Providing & fixing of Lt ACB 800 Amp Nos. 250 Amp. Output MCCB and suitable covering & mounting strucuture
78Providing & fixing of Lt ACB 630 Amp Nos. 250 Amp. Output MCCB and suitable covering & mounting strucuture
79Providing & fixing of Foundation of RMU 3 Cubic Meter
80Pipe and Pipe gel Earthing for R.M.U
81Providing & fixing of Danger Board
82Providing & fixing of Barbed Wire
83Sagging of Guarding G.I. Wire
84Providing & fixing of Stone Pad
85Providing & fixing of Boot Protection For T/F Monkey Fault
86Providing & fixing 16 sqmm. Alumimum thimble
87Providing & Fixing of PVC Pipe 3" of diameter
88Providing and Instllation of 24 Volt Battery with Charger.
89Providing & Fixing of 33 KV V type Steel Cross Arm
90Provoding & Fixing of 11 KV V type Steel Cross Arm
91Providing & Fixing of 11 KV Pin Insulator with pin
92Providing & Fixing of 33 KV V type Steel Cross Arm Holding Clamp
93Providing & Fixing of 11 KV V type Steel Cross Arm Holding Clamp
94Providing & Fixing of 33 KV Pin Insulator with pin
95Providing & Fixing of Disc Insulator 45 KN & 70 KN (T&C/B&S) with fitting
96Providing & fixing of 33 KV F Bracket
97Providing & fixing of 11 KV F Bracket
98Providing & fixing of Packing Piece Clamp for 33 KV/11 KV with nut & bolts
99Providing & fixing of Aluminium Lug 25 sqmm.
100Providing & fixing of Aluminium Lug 70 sqmm.
101Providing & fixing of Aluminium Lug 150 sqmm.
102Providing & fixing of Aluminium Lug 240 sqmm.
103Providing & fixing of Aluminium Lug 400 sqmm.
104Providing & fixing of Aluminium Lug 630 sqmm.
105Providing & fixing of Aluminium Lug 1000 sqmm.
106Providing & Sagging/Fixing of Al. XLPE 1x1000 Sq.mm. Cable
107Installation of 11/0.4 KV, 400 KVA T/F Mobile Trolley
108Providng Trolley Structure for 400 KVA T/F with vehicle tyre,rim,coupling,trolly hook,earthing, painting and related accessories with complete job
109Supply of G.I. Pipe Chemicalearthing electrode 3 mtr. long 80 mm inner dia along with chemical powder and 50x6 mm G.I. Strip with Nut, Bolt and Washer.
110Earthing of Power Transformer (Urban) by digging of pit up to water level depth Approx. 90 feet. into the boring 1-1/4" dia GI pipe of "B" grade,conforming to the requirement of IS specification and then connecting the top of the inserted pipe and Power Transformer body earthing through M.S. strip of size 50x6mm with the help of Electric welding Lum Sum Rate. It includes the cost of all material, labour, Carrier etc. required for proper completion of work.
111Installation of D.O. Fuse Set of 11 KV
112Supply, install, testing and commisioning of 11 KV 630 Amps 21 KA for 3 Sec. SF6 insulated, one side extesible, outdoor duty 3 way R.M.U. manual operate, in combination of 01 nos. VCB modules (O/G) & 2 Nos. Load BreakerSwitch modules (I/C), CONSITIING OF COPPER BUSBAR in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5 mm with manometer fixed on the tank. the breaker shall have mechanical ON/OFF indicator with hand Trip device and spring charging, spring relase coil, auxiliary switch of 02 NO +2NC. The HV switchgerar and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU gas tank should be internal arc tested for 21 KA for 1Second with IAC-AFL classification for gas tank. The complete RMU Should have ingress protection of minimum IP54. The RMU design should support site replaceable HT cable bushing. All the type test certified as per IEC from Third party lab to be submitted. RMU should have :- 01 Nos. micorprocessor based self powered numerical relay with over Current/earth fault & short circuit protection wiht each VCB feeder. - 3Nos. Protection CT Shall be of Burden 2.5 VA, ratio 200/1A, Class of Accuracy class 5P10 for O/C and E/F Protection for each VCB. (CT ration is indicative and may vary during detailed engineering) -1 No. Manometer for each tank-1 Nos. Voltage passage indicator for each feeder. -1 Nos. Fault Passage Indicator for each LBS Module.- Right angle boots for all the feeder Modules- Basic insulation level of complete system shall be 28KV(RMS)/75KV(Peak)- Vacuum Interrupter & RMU Should be of same make for better life cycle optimization.
113Supply, install, testing and commisioning of 11 KV 630 Amps 21 KA for 3 Sec. SF6 insulated, one side extesible, outdoor duty 4 way R.M.U. manual operate, in combination of 02 nos. VCB modules (O/G) & 2 Nos. Load BreakerSwitch modules (I/C), CONSITIING OF COPPER BUSBAR in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5 mm with manometer fixed on the tank. the breaker shall have mechanical ON/OFF indicator with hand Trip device and spring charging, spring relase coil, auxiliary switch of 02 NO +2NC. The HV switchgerar and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU gas tank should be internal arc tested for 21 KA for 1Second with IAC-AFL classification for gas tank. The complete RMU Should have ingress protection of minimum IP54. The RMU design should support site replaceable HT cable bushing. All the type test certified as per IEC from Third party lab to be submitted. RMU should have :- 01 Nos. micorprocessor based self powered numerical relay with over Current/earth fault & short circuit protection wiht each VCB feeder. - 3Nos. Protection CT Shall be of Burden 2.5 VA, ratio 500/1A, Class of Accuracy class 5P10 for O/C and E/F Protection for each VCB. (CT ration is indicative and may vary during detailed engineering) -1 No. Manometer for each tank-1 Nos. Voltage passage indicator for each feeder. -1 Nos. Fault Passage Indicator for each LBS Module.- Right angle boots for all the feeder Modules- Basic insulation level of complete system shall be 28KV(RMS)/75KV(Peak)- Vacuum Interrupter & RMU Should be of same make for better life cycle optimization.
114Supply, install, testing and commisioning of 11 KV 630 Amps 21 KA for 3 Sec. SF6 insulated, one side extesible, outdoor duty 5 way R.M.U. manual operate, in combination of 03 nos. VCB modules (O/G) & 2 Nos. Load BreakerSwitch modules (I/C), CONSITIING OF COPPER BUSBAR in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5 mm with manometer fixed on the tank. the breaker shall have mechanical ON/OFF indicator with hand Trip device and spring charging, spring relase coil, auxiliary switch of 02 NO +2NC. The HV switchgerar and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU gas tank should be internal arc tested for 21 KA for 1Second with IAC-AFL classification for gas tank. The complete RMU Should have ingress protection of minimum IP54. The RMU design should support site replaceable HT cable bushing. All the type test certified as per IEC from Third party lab to be submitted. RMU should have :- 01 Nos. micorprocessor based self powered numerical relay with over Current/earth fault & short circuit protection wiht each VCB feeder. - 3Nos. Protection CT Shall be of Burden 2.5 VA, ratio 500/1A, Class of Accuracy class 5P10 for O/C and E/F Protection for each VCB. (CT ration is indicative and may vary during detailed engineering) -1 No. Manometer for each tank-1 Nos. Voltage passage indicator for each feeder. -1 Nos. Fault Passage Indicator for each LBS Module.- Right angle boots for all the feeder Modules- Basic insulation level of complete system shall be 28KV(RMS)/75KV(Peak)- Vacuum Interrupter & RMU Should be of same make for better life cycle optimization.
115Supply &Erection offactory fabricated&wired metalcladdustandverminprooffloormounting double door type outdoor application,with M.S. Channel Base with bottom and top cable entreis shall be detachable type gland plateElectricalcontrolpanelwith 01 No. 630 Amp. ACB& 03 No. 250 Amp. MCCB The instrument chambershallbeseparate and incomming section connecting with proper horizental /vertical busbar and outgoing section with cable alley sectionandshall metering with digital multifuncation meter with inbuilt Selector switches,istrument fuses, red yellow and blue phase indicators in incomming section, currenttransormeretc.The Boardshallhave suitablecapacity electrolyticaluminiumbusbarsinsulatedwithheatshrink color codesleevand mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entryboxesshallbecompletewithsuitablecable end boxes Theswitchboardshallbe fabicated with gelvnized primesheet with a minimum thickness of 1.6 mm/2mm. with seven tank process powder coated
116Supply &Erection offactory fabricated&wired metalcladdustandverminprooffloormounting double door type outdoor application,with M.S. Channel Base with bottom and top cable entreis shall be detachable type gland plateElectricalcontrolpanelwith 01 No. 800 Amp. ACB& 01 No. 400 Amp. MCCB & 02 No. 250 Amp. MCCB The instrument chambershallbeseparate and incomming section connecting with proper horizental /vertical busbar and outgoing section with cable alley sectionandshall metering with digital multifuncation meter with inbuilt Selector switches,istrument fuses, red yellow and blue phase indicators in incomming section, currenttransormeretc.The Boardshallhave suitablecapacity electrolyticaluminiumbusbarsinsulatedwithheatshrink color codesleevand mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entryboxesshallbecompletewithsuitablecable end boxes Theswitchboardshallbe fabicated with gelvnized primesheet with a minimum thickness of 1.6 mm/2mm. with seven tank process powder coated
117Supply &Erection offactory fabricated&wired metalcladdustandverminprooffloormounting double door type outdoor application,with M.S. Channel Base with bottom and top cable entreis shall be detachable type gland plateElectricalcontrolpanelwith 01 No. 1250 Amp. ACB, 02 No. 400 Amp. MCCB & 02 No. 250 Amp. MCCB The instrument chambershallbeseparate and incomming section connecting with proper horizental /vertical busbar and outgoing section with cable alley sectionandshall metering with digital multifuncation meter with inbuilt Selector switches,istrument fuses, red yellow and blue phase indicators in incomming section, currenttransormeretc.The Boardshallhave suitablecapacity electrolyticaluminiumbusbarsinsulatedwithheatshrink color codesleevand mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entryboxesshallbecompletewithsuitablecable end boxes Theswitchboardshallbe fabicated with gelvnized primesheet with a minimum thickness of 1.6 mm/2mm. with seven tank process powder coated
118Providing & Fixing of Dead end clamp With I-Hook
119Providing & Fixing of Suspension Clamp With I- Hook
120Providing & Fixing of piercing Clamp
121Installation of LT Distribution Box
122Providing & Fixing of PVC Pipe 2" of diameter
123Providing & Fixing of Clamp For Distribution Box
124Concreting of Pole (ST 13 Mtr./11 Mtr.) PCC Pole
125Providing and Fixing/Installation of Compact Substation T/F of 400 KVA including all relevant and required accessories.
126Removal of old transformer(250 KVA) with all connected accessories from existing double pole.
127Removal of old transformer(100 KVA) with all connected accessories from existing double pole.
128Removal of old transformer(63KVA) with all connected accessories from existing double pole.
129Removal of old transformer(25KVA) with all connected accessories from existing double pole.
130Construction of Plinth 6x6x4 Height from ground as per sc (as per approved GTP)
131Installation of following transformer on Plinth/Double pole with all connecting accessories jumering etc. including carriage of transformers from store centre, Mathura to work site.
132400 KVA Transformer on Plinth
133250 KVA Transformer on Plinth
134100 KVA Transformer on Double Pole
13563 KVA Transformer on Double Pole
136Providing and Installation of Tail less unit complete
137Mash/FRP Fencing of Sub-Station with civil works (as per approved GTP)
138Complete Pipe in Pipe Gel earthing of 11/0.4 KV 250/400 Distribution Transformer by digging pits 6” dia upto 3 mtr. deep including chemical filled pipe in between (pipe-in-pipe) ISI mark B Grade & connecting with G.I strip of size 50mm X 6mm with neutral/body of 11/0.4 KV distribution transformer to above pipe-in-pipe (PIP) and filling of chemical crystalline conductive mixture containing highly conductive material around the (pipe-in-pipe) up to 3 Mtr. including making of chamber at the top of the earthing. Other details are as below:- 1.Earth pipe material – mild steel, Galvanised. 2-Main Electrode diameter – 42.4mm. 3-Auxiliary Electrode pipe, Diameter – 76mm. 4-Wall Thickness of main Electrode :- 2.6mm. 5-Wall thickness of auxiliary Ist whole:- 3.2mm. 6- Length of earthing electrode (PIP):- 3 Meter.
139Dismantling of damaged & used items i.e. Distribution Transformer, ST/PCC Pole, HT/LT cable, Conductor (Scrap) & other accessories at work site and carriage dismantled material from Site to Store Center, Mathura.
140Proper Road Restoration Kaccha/Pakka (If required) Rates shall be acceptable, if not given above for the same work.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail