Tender For Provision Of Deficient Living In Accn At Af Stn Naliya (Phase-Ii) (88238/E8), naliya-Gujarat

Military Engineer Services-MES has published Tender For Provision Of Deficient Living In Accn At Af Stn Naliya (Phase-Ii) (88238/E8). Submission Date for this Tender is 02-11-2023. Tanks and Cylinders Tenders in naliya Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

39895927
Corrigendum : Tender For Provision Of Deficient Living In Accn At Af Stn Naliya (Phase-Ii) (88238/E8)
Open Tender
Indian
Gujarat
naliya
02-11-2023

Tender Details

Provision Of Deficient Living In Accn At Af Stn Naliya ( Phase-Ii ) ( 88238 / E8 ) ; 1 Note: Schedule ‘A’ Part Ito Ix Are Under Ser No. 1.00To 9.00. Are Prepriced By Mes. Bidders Shall Insert Their Lumpsum Amount In The Green Coloured Field Under Col-6 Only. 2 Lump Sum Price Worked Outforbuilding / Structures As Listed In Sch `A’ Part I. 3 Lump Sum Price Worked Outby The Contractor For Excavation & Earthwork As Listed In Sch `A’ Part Ii 4 Lump Sum Price Worked Out By The Contractor For Internal Water Supply As Listed Insch `A’ Part Iii 5 Lump Sum Price Worked Out By The Contractor For Internal Electrification As Listed In Sch A Part Iv 6 Lump Sum Price Worked Out By The Contractor For Road / Path / Culvert / Hard Standing As Listedin Sch A Part V 7 Lump Sum Price Worked Out By The Contractor Forsewage Disposal As Listed In Sch `A’ Part Vi. 8 Lump Sum Price Worked Out By The Contractorforexternal Water Supply As Listed In Sch `A’ Part Vii 9 Lump Sum Price Worked Out By The Contractorfor External Electrification As Listed In Sch `A’ Part Viii 10 Lump Sum Price Worked Out By The Contractor For Fire Fighting As Listed In Sch `A’ Part Ix. 11 Schedule A Part - X ( Misc Items ) ( Note : The Contractor Shall Quote His Rate For Each Of These Items Separately. The Estimated Rate Is Left Blank Since The Same Is Not Prepriced By Mes ) 12 Supply And Fix Distribution Board Made Out Of Sheet Metal Powder Coated, Factory Made, Enclousure Double Door Type Tpn 4 Way Vertical Type With 200 ( Amps Rated Copper Bus Bar, Neutral Bar, Earth Bar, Tp 43 Protection Including Provision Of Housing Of Incomer Mccb 63 Amps, Triple Pole And Neutral, 415V, 16 Ka Breaking Capacity Fixing Of Db Flush To Wall Surface Complete All As Specified And Directed. 13 Supply And Fix Desert Cooler Suitable For Air Delivery 5500 Cum Per Hour Having Water Tonic Capacity 100 Ltr And 18 Fan, Everlast Pump Of Suitable Size And Motor With Overload Protection, Cooling Medium As High Density Honeycomb Pad Complete With Fully Collapsible Louvers And Mosquito Net Complete Pvc Type All As Specified And Directed.Make: Optimus 100 Of Crompton Or Equivalent In Symphony, Bajaj Or Havells As Approved By Ge. 14 Supply And Fix Water Cooler Electric Driven ( Single Phase ) , Having Approx Storage Capacity Of 80 Litre And Nominal Cooling Capacity Of 40 Litres Per Hour Complete All As Specified And Directed. 15 Supply And Fix Ms Flanged Pipe 80Mm Nb Heavy Duty For Multi Storeyed Building Duly Painted With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer Complete All As Specified And Directed. 16 Supply And Fix Ms Flanged Pipe 65Mm Nb Heavy Duty For Multi Storied Building Duly Painted With 2 Coats Of Synthetic Enamel Paint Over Coat Of Zinc Chromate Primer Complete All As Specified And Directed. 17 Supply And Fix Ms Flanged Pipe 40Mm Nb Heavy Duty For Multi Storied Building Duly Painted With 2 Coats Of Synthetic Enamel Paint Over Coat Of Zinc Chromate Primer Complete All As Specified And Directed. 18 Supply And Fix Ms Flanged Pipe 25Mm Nb Heavy Duty For Multi Storied Building Duly Painted With 2 Coats Of Synthetic Enamel Paint Over Coat Of Zinc Chromate Primer Complete All As Specified And Directed. 19 Providing, Supplying, Erection And Insatallation Of Structural Steel Including 8Mm Thick Ms Plate, Ismc, Isa, M14, 110 Long Anchor Fastners With One Coat Of Red Lead Primer And Two Coats Of Black Paint Complete All As Specified And Directed. 20 Supply, Installation, Testing And Commissioning Of Jockey Pump For 440V, 3 Phase, 50Hz Conroming To Is-12469: 1988 With Ci Casing Bronze Impeller And Stainless Steel Shaft Mounted On Heavy Duty Bearing Suitable For 440 Volts, 3 Phase, 50 Hz, 30Mtr Head, 450 Lmp Discharge Complete All As Specified And Directed. 21 Supply, Installation, Testing And Comissioning Of Electric Terrace Fire Control Panel Metal Clad Cubical Tpe Suitable For 415 Volt Ac Three Phase 4 Wire 50 Hz Supply System. The Panel Should Be Suitable For Automatic Operation For The Fire Pump As Per The Specified Parameter. The Panel Shall Be Completely Compartmentlised And Complete With Relays, Contactors, Starters, Copper Bus Bar 100 Amps Rating, Designation Lables As Per Requirement, Continous Earth Bar, Panel Separators, Protective Screens, Cable Clamping Supports System, Panel Lamps, Top / Bottom Cable Gland Plate For Incoming And Outgoing Cable Entries Complete Consisting Of The Following:Incoming ( A ) Mccb 3 Pole 40 A, 16 Ka- 1 No Incoming ( B ) Automatic / Manual Switch And Control Wiring For Automatic Operation Of Main Fire Pump Sets- 01 ( C ) Digital Ammedter With Cts 100 Amps ( C ) Digital Voltmeter 0-500 Volts ( E ) Indicating Lamp- 3 Nosoutgoing ( A ) Mccb 3 Pole 32 Amp 16 Ka- 01 No ( B ) Mccb Of 3 Pole 32 Amp, 16Ka- 01 No 22 Supply, Installation, Testing And Commissioniong Of Carbon Dioxide ( Co2 ) Type Fire Extinguisher Capaicity 4.5 Kg Conforming To Is 15683, With Isi Marked / Tac Approved Fitted With Required Accessories Including Wall Suspension Brackets, Pesco / Ccoe Approved Cylinder Body And Confirms To Is:7285, High Grade Enamel Painted Externally With Po Red Finish, Wheel Operated Controllable Discharge High Pressure Brass Valve Confirming To Is: 3224 Which Is Provided With Pressure Relief Dischargeable And Easy To Service, Non Conductive Agent For Electrical Use Without Risk To Operator, Co2 Gas Disappears Quickly Leaving No Residue Applicable On Class B & C And Electrically Started Fire, B Rating 21B Started Fire. A Rating 3A, Rating 21B Sfety Pin Is Of Ss Material Sheet Metal Thickness :1.0 Mm Helium Leak Detection Tested Isi Approved Is 15683:2006 With 5 Years Warranty Complete All As Specified And Directed. 23 Supply, Installation, Testing And Commissioning Of Abc Type Fire Extinguisher Capacity 6 Kg Filled With Mono Ammonium Phosphate Power 50% Conforming To Is 14609, Powder Coated Ms Body Stored Pressure Type Discharge Time 18 Sec, Controllable Discharge Is 90%, Applicable On Class, A, B &C And Electrically Started Fire, A Rating -3A, Rating 21B Safety Pin Is Of Ss Material, Sheet Metal Thickness 1.0 Mm, Helium Leak Detection Tested Isi Apporved Is 15683:2006 With 5 Years Warranty Complete All As Specified And Directed. 24 Supply, Installation, Testing And Commissioning Water Heater, Storage Type, Electric, Of Capacity 25 Litres, Bee 5 Star Rated Complete All As Specified And Directed.Make Bajaj / Usha / Racold Or Equivalent As Approved By Ge 25 M & L For Cutting Of Existing 80 Mm Gi Pipeline And Inserting Tee 80X80x50 Mm And Connecting 50 Gi Pipe With Reducer Complete All As Specified And Directed. 26 M&L For Precast Cement Concrete Block Masonry Walling With Solid Blocks Of Pcc 1:5:8 Using 20Mm Graded Stone Aggregates, Exc 10Cm In Width And Set In Cement Plaster ( 1:6 ) Complete All As Specified And Directed. 27 Supply, Installation, Testing And Commissioning Lt Panel, Outdoor Type, Dust And Vermin Proof, Totally Enclosed, Platform Mounted, Factory Made Having Front Openable Shutter With Locking Arrangement Made Out Of Crca Stell Sheet 3.15 Mm Thick With Ms Angle Iron Frame Work Of Size 40 Mm X 40 Mm X 6 Mm Thick Duly Painted All As Specified Including Necessary Foundation Bolts, Pcc ( 1:2:4 ) , Type B-1 Platform Of Suitable Size For Mounting The Panel, Suitable For 415 Volts, 50 Hz Three Phase, 4 Wire System With Suitable Insulated Aluminium Busbar Of Capacity Not Less Than 600 Amps And Shall Be Complete With Internal Wiring With Copper Conductor And Including The Following Accessories. ( A ) Main Incoming ( I ) Mccb Conforming To Is:13947 ( Part-Ii ) , Iec-947, Tpn ( 4 Pole ) , 125 Amps, 415 Volts, 50 Hz, Rupturing Capacity 16 Ka, With Adjustable Thermal And Adjustable Magnetic Setting - 01 No. ( Ii ) Led Multifucntional Panel Meter To Measure Voltage, Current, Frequency, Power Factor, Kwh, Etc. With All Connected Cts. ( Iii ) Led Indicating Lamps With Colour Red, Yellow, Blue ( 03 Lights ) - 01 Set ( B ) Main Outgoing ( I ) Mccb Conforming To Is:13947 ( Part-Ii ) , Iec-947, 4 Pole, 63 Amps, 415 Volts, 50 Hz, Rupturing Capacity 16 Ka, With Adjustable Thermal And Adjustable Magnetic Setting - 02No. ( For Db And One Spare )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Oct-2023 REVISED AMENDMENT Other 26-10-2023
2 10-Oct-2023 REVISED DRAWINGS CONTINUE Other 26-10-2023
3 10-Oct-2023 REVISED DRAWINGS Other 26-10-2023
4 10-Oct-2023 Amendment in revised drawings Other 26-10-2023
5 13-Oct-2023 2nd amendment in tender documents Other 26-10-2023
6 13-Oct-2023 REVISED BOQ BOQ 26-10-2023
7 26-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-11-2023

Key Value

Document Fees
INR 2000 /-
EMD
INR 355000.0 /-
Tender Value
INR 2.80 Crore /-

BOQ Items

Name of Work:PROVISION OF DEFICIENT LIVING IN ACCN AT AF STN NALIYA (PHASE-II) (88238/E8)
Sl. No. Item Description
1NOTE: Schedule ‘A’ Part Ito IX are under Ser No. 1.00to 9.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
2Lump sum price worked outforBuilding / Structures as listed in Sch `A’ Part I.
3Lump sum price worked outby the Contractor for Excavation & Earthwork as listed in Sch `A’ Part II
4Lump sum price worked out by the Contractor for Internal Water Supply as listed inSch `A’ Part III
5Lump sum price worked out by the Contractor for Internal Electrification as listed in Sch "A" Part IV
6Lump sum price worked out by the Contractor for Road/Path/Culvert/Hard standing as listedin Sch "A" Part V
7Lump sum price worked out by the Contractor forSewage Disposal as listed in Sch `A’ Part VI.
8Lump sum price worked out by the ContractorforExternal Water supply as listed in Sch `A’ Part VII
9Lump sum price worked out by the Contractorfor External Electrification as listed in Sch `A’ Part VIII
10Lump sum price worked out by the Contractor for Fire Fighting as listed in Sch `A’ Part IX.
11SCHEDULE "A" PART - X (MISC ITEMS) (Note : The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
12Supply and fix distribution board made out of sheet metal powder coated, factory made, enclousure double door type TPN 4 way vertical type with 200 (Amps rated copper bus bar, neutral bar, earth bar, TP 43 protection including provision of housing of incomer MCCB 63 Amps, triple pole and neutral, 415V, 16 KA breaking capacity fixing of DB flush to wall surface complete all as specified and directed.
13Supply and fix desert cooler suitable for air delivery 5500 cum per hour having water tonic capacity 100 Ltr and 18" fan, everlast pump of suitable size and motor with overload protection, cooling medium as high density honeycomb pad complete with fully collapsible louvers and mosquito net complete PVC type all as specified and directed. Make: Optimus 100 of Crompton or equivalent in Symphony, Bajaj or Havells as approved by GE.
14Supply and fix water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete all as specified and directed.
15Supply and fix MS flanged pipe 80mm NB heavy duty for multi storeyed building duly painted with 2 coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified and directed.
16Supply and fix MS flanged pipe 65mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and directed.
17Supply and fix MS flanged pipe 40mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and directed.
18Supply and fix MS flanged pipe 25mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and directed.
19Providing, supplying, erection and insatallation of structural steel including 8mm thick MS Plate, ISMC, ISA, M14, 110 long Anchor Fastners with one coat of RED LEAD primer and two coats of Black paint complete all as specified and directed.
20Supply, installation, testing and commissioning of Jockey Pump for 440V, 3 Phase, 50Hz conroming to IS-12469: 1988 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearing suitable for 440 volts, 3 Phase, 50 Hz, 30mtr head, 450 LMP discharge complete all as specified and directed.
21Supply, installation, testing and comissioning of Electric Terrace Fire control panel metal clad cubical tpe suitable for 415 Volt AC three phase 4 wire 50 Hz supply system. The panel should be suitable for automatic operation for the fire pump as per the specified parameter. The panel shall be completely compartmentlised and complete with relays, contactors, starters, copper bus bar 100 Amps rating, designation lables as per requirement, continous earth bar, panel separators, protective screens, cable clamping supports system, panel lamps, top/bottom cable gland plate for incoming and outgoing cable entries complete consisting of the following: Incoming (a) MCCB 3 Pole 40 A, 16 KA- 1 No incoming (b) Automatic/ manual switch and control wiring for automatic operation of main fire pump sets- 01 (c) Digital AMmedter with CTs 100 Amps (c) Digital Voltmeter 0-500 volts (e) Indicating lamp- 3 Nos Outgoing (a) MCCB 3 Pole 32 Amp 16 KA- 01 No (b) MCCB of 3 Pole 32 Amp, 16KA- 01 No
22Supply, installation, testing and commissioniong of Carbon Dioxide (CO2) type fire extinguisher capaicity 4.5 kg conforming to IS 15683, with ISI marked/ TAC approved fitted with required accessories including wall suspension brackets, PESCO/ CCOE approved cylinder body and confirms to IS:7285, High grade Enamel painted externally with PO Red finish, wheel operated controllable discharge high pressure brass valve confirming to IS: 3224 which is provided with pressure relief dischargeable and easy to service, non conductive agent for electrical use without risk to operator, CO2 gas disappears quickly leaving no residue applicable on class B & C and electrically started fire, B rating 21B started fire. A rating 3A, Rating 21B sfety pin is of SS material sheet metal thickness :1.0 mm Helium leak detection Tested ISI Approved IS 15683:2006 with 5 years warranty complete all as specified and directed.
23Supply, installation, testing and commissioning of ABC type fire Extinguisher capacity 6 kg filled with Mono Ammonium Phosphate power 50% conforming to IS 14609, powder coated MS body stored Pressure type Discharge time 18 Sec, controllable discharge is 90%, applicable on class, A,B &C and electrically started fire, A rating -3A, Rating 21B safety pin is of SS material, sheet metal thickness 1.0 mm, helium leak detection tested ISI apporved IS 15683:2006 with 5 years warranty complete all as specified and directed.
24Supply, installation, testing and commissioning water heater, storage type, electric, of capacity 25 litres, BEE 5 star rated complete all as specified and directed. Make Bajaj/ Usha/ Racold or equivalent as approved by GE
25M & L for cutting of existing 80 mm GI pipeline and inserting Tee 80x80x50 mm and connecting 50 GI pipe with reducer complete all as specified and directed.
26M&L for precast cement concrete block masonry walling with solid blocks of PCC 1:5:8 using 20mm graded stone aggregates, exc 10cm in width and set in cement plaster (1:6) complete all as specified and directed.
27Supply, installation, testing and commissioning LT Panel, Outdoor type, dust and vermin proof, totally enclosed, platform mounted, factory made having front openable shutter with locking arrangement made out of CRCA stell sheet 3.15 mm thick with MS angle iron frame work of size 40 mm x 40 mm x 6 mm thick duly painted all as specified including necessary foundation bolts, PCC (1:2:4), type B-1 platform of suitable size for mounting the panel, suitable for 415 Volts, 50 Hz three phase, 4 wire system with suitable insulated aluminium busbar of capacity not less than 600 Amps and shall be complete with internal wiring with copper conductor and including the following accessories. (A) Main Incoming (i) MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (4 pole), 125 Amps, 415 volts, 50 Hz, rupturing capacity 16 KA, with adjustable thermal and adjustable magnetic setting - 01 No. (ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc. with all connected CTs. (iii)LED indicating lamps with colour Red, Yellow, Blue (03 Lights) - 01 Set (B) Main Outgoing (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 63 Amps, 415 volts, 50 Hz, rupturing capacity 16 KA, with adjustable thermal and adjustable magnetic setting - 02No. (for DB and one spare)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail