Tender For Repair And Maintenance Of Ht 11 Kv Distribution Network And Connected Items Of Works At Md Accn Area At Chandimandir, chandimandir-Haryana

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Ht 11 Kv Distribution Network And Connected Items Of Works At Md Accn Area At Chandimandir. Submission Date for this Tender is 09-11-2023. Overhead Line Tenders in chandimandir Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

39894630
Corrigendum : Tender For Repair And Maintenance Of Ht 11 Kv Distribution Network And Connected Items Of Works At Md Accn Area At Chandimandir
Open Tender
Indian
Haryana
chandimandir
09-11-2023

Tender Details

Repair And Maintenance Of Ht 11 Kv Distribution Network And Connected Items Of Works At Md Accn Area At Chandimandir

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Oct-2023 corrigendum Date 02-11-2023
2 20-Oct-2023 corrigendum_ Other 02-11-2023
3 20-Oct-2023 corrigendum BOQ 02-11-2023
4 02-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-11-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 122500.0 /-
Tender Value
INR 65 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINT OF HT 11 KV DISTRIBUTION NETWORK AND CONNECTED ITEMS OF WORKS AT MD ACCN AREA AT CHANDIMANDIR
Sl. No. Item Description
1Disconnecting and taking out existing defective HT cable of any size complete including joints/protection pipes etc from trenches/ducts/poles etc complete all as specified and directed.
2Taking out old damaged PCC pole of any size incl breaking PCC foundation and clearing the site complete all as specified and directed.
3Taking down old rusted cross arms/anti climbing devices incl clamps, nuts/bolts etc complete all as specified and directed.
4Taking down old unserviceable HT insulators of any size and typecomplete all as specified and directed.
5Disconnecting and taking out LT Panel of any type and size complete all as specified and directed.
6Taking down old burnt HT jumpers of any size/type complete all as specified and directed.
7Taking down old unserviceable HT GOD of any size/type complete all as specified and directed.
8Taking out old unserviceable rubber mats of any size and type complete all as specified and directed.
9Taking down old broken cable route indicator ofany size/type complete all as specified and directed.
10Taking down old unserviceable HT lightening arrestors of any size/type complete all as specified and directed.
11Taking down existing chain link fencing from any type of post complete all as specifed and directed
12Dismantling of RCC Post or struts of any section including taking down embedded portion and making good disturbed ground complete all as specifed and directed
13M & L for PCC 1:4:8 type D-2 using 40 mm graded crushedstone aggregate as in pole foundations etc complete all as specifed and directed
14M & L for PCC 1:3:6 type C-2 using 40 mm graded crushedstoneaggregate in foundation filling & mass concrete for poles/struts etc including provision of necessary form workcomplete all as specified and directed.
15M & Lfor PCC 1:2:4 type B-1 using 20 mm graded crushedstoneaggregate in pole / strut coping including provision of necessary form work complete all as specified and directed.
16Supply and fix Galvanised steel tubing, light grade, with fittings and MS clamps, nuts, bolts etc of 100 mm dia bore for cable protection on pole/wall, road crossing/driange/footpath alongwith PCC work making the disturbed surface as per existing surface complete all as specified and directed.
17Supply and laying in replacement 100 mm outer dia, double walled corrugated HDPE duct pipe in replacement including taking out unserviceable GI pipe confirming to IS-14930 Part-II with antirodent and non flame propogating properties of approved colour complete with fitings for cable protection complete all as specified and as directed.
18S & F in replacement operating handle for outdoor type HT 11 KV GOD switches complete all as specified and directed.
19S & F gang operated air break switches with vertical isolation complete with drop out fuse unit assembly , triple pole, 12 insulator type, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level for capacity 400 Amps, 11 KV complete withGI operating pipe of heavy duty grade of suitable length complete all as specified and directed.
20All as per item no 19 here in before but of rating200 Amps complete all as specified and directed.
21M & L for route indicator for HT cable disc type of size 150 mm dia CI, 8 mm thickness embossed with " MES HT CABLE" and fixed on angle iron 35 x 35 x 5 mm, 600 mm long as directed and painted in anti corrosive brown color paint incl PCC 1:2:4 type B-1 foundation block of size 300 x300 x 300 mm, duly fixed in ground complete all as specified and as directed.
22M & L in repairsGI strip 32x6 mm and connecting from earth test point to lightening arrestor installed on top of 11 mtr long poles four pole/ two pole structures complete all as specified and directed.
23M & L for servicing of the outdoor type HT 11 KV 200 amps/400 amps capacity gang operated air break switch mounted on HT two pole/four pole structure by properly adjusting the mountings for ON/OFF operation by working from ground level, adjusting the length of operation rod ,lubricating the moving parts, tightening of all nuts/bolts, checking of all jumper connections for proper contact of male/female contacts, replacing worn out spares and testing for proper working complete all as specified and as directed. Note:- Spare parts will be measured and paid separately.
24Supply only moving contact blade (male contact) suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified and directed.
25Supply only spring loaded fixed contacts (female contact jaw) suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified and directed.
26Supply only post insulators suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
27Supply only tinned copper flexible wires woven connecting jumper suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
28Supply only MS jumper carrier for 200 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
29Supply only moving contact blade (male contact) suitable for 400 amps 11 KV outdoor GOAB switch complete all as specified and directed.
30Supply only spring loaded fixed contacts (female contact jaw) suitable for 400 amps 11 KV outdoor GOAB switch complete all as specified and directed.
31Supply only post insulators suitable for 400 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
32Supply only tinned copper flexible wires woven connecting jumper suitable for 400 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
33Supply only MS jumper carrier for 400 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
34M & L anti climbing devices, spikes type fabricated out of M.S. bars ( round,square and flat ) including nuts,bolts,Washers and clamps made to shape to suit the size of the pole complete all as specified and directed.
35Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for laying of cable,erection of poles etc. and getting out complete all as specified and directed.
36Excavation in trenches in hard/dense soil not exceeding 1.50 metre wide , exceeding 1.5 mtr and not exeeding 3.0 mtr in depth , for erection of poles etc. and getting out complete all as specified and directed.
37Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified and directed.
38Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
39Supplying and laying in replacement un-reinforced precast concrete cable cover, class HV, type 1 flat , size 300mm x 180mm x 40mm complete all as specified and directed.
40M & L for dry sand filling under and around UG cable to provide cushioning complete all as specified and directed.
41S & F in replacement HT heat shrinkable type outdoor end termination cable jointing kit sutable for 11 KV (Earthed) grade XLPE cable of size 50 sqmm to 95 Sqmm, 3 core complete all as specified and directed.
42All as per item No 41 here in before but of size 120 to 185 Sqmm complete all as specified and directed.
43All as per item No 41 here in before but of size 240 sqmm.complete all as specified and directed.
44S & F in replacement HT heat shrinkable type indoor end termination cable jointing kit suitable for 11 KV (Earthed) with jointing material and accessories grade XLPE cable of size95 Sqmm, 3 core complete all as specified.
45All as per item No 44 here in before but of size 120 to 185 Sqmm.complete all as specified and directed.
46All as per item No 44 here in before but of size 240 sqmm.complete all as specified and directed.
47S & F in replacement HT straight through heat shrinkable type cable jointing kit for 11 KV grade, XLPE cableof size 95 sqmm 3 core complete all as specified and directed.
48All as per item No 47 here in before but of size 120 to 185 Sqmm
49All as per item No 47 here in before but of size 240 sqmm.
50S & F in trenches, ducts or fixing along the poles or passing through pipes or laid under floors etc and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cables ISI marked with aluminium conductor, 11000 volts grade cross sectional area 120 sqmm 3 core, 11 KV earthed, complete all as specified and directed.
51All as per item No 50 here-in-before but 150 Sqmm 3 core
52All as per item No 50 here-in-before but 185 Sqmm 3 core
53Disconnecting and taking out existing defective LT cable of any size complete including joints/protection pipes etc from trenches/ducts/poles etc complete all as directed.
54Supply, laying, jointing and testing LT underground cable XLPE insulated , PVC sheathed, armoured heavy duty and1100 volts grade with multistranded aluminium conductor of size 185 sqmm 3.5 core in trenches/ducts/through pipes/under culverts etc complete all as specified and as directed.
55All as per item No 54 here in before but size 240 sqmm 3.5 core complete all as specified and as directed.
56Supplying and laying in repair un-reinforced precast concrete cable cover, class LV, type 1 flat , size 250mm x 150mm x 40mm complete all as specified and directed.
57M & L cross arms,supports, clamps etc fabricated from structural steel section including nuts, bolts , washers, welding, bending ( cold or hot ) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of one coat of primer, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
58Excavation in post holes (or similar holes) each not exc 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface complete in any type of soil.
59M&L for mild steel work as of posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets(for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 complete including painting with two coats of synthetic enamel paint of approved color over a coat of red oxide primer complete all as specified and directed.
60Supply and fix of Galvanized Steel Chain Link fencing of mesh size 50mm x 50mm and dia of wire 4.00mm with and including line wires fixed to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed
61M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etcconforming to Fe.290.Gde-E-165 including taking down existing framed work of any description complete all as specified and directed.
62Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil in the transformer yard complete all as specified and directed.
63Supply and spread graded coarse aggregate of 63mm nominal size around outdoor transformer and HT 11 KV two/four pole structure complete all as specified and directed.
64M&L for Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
65M&L forrendering 10mm thick cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (with out using extra cement) complete all as specified and directed.
66Supply, installation,commissioning and testing outdoor type floor mounting double door feeder pillar box , fabricated from 3.15 mmthick CRCA sheet and MC 75 for base channel, 04 nos legs 750 mm longmade from 50 x 50 x 6 mm angle iron , duly powder coated, dust/water and weather proof , grouted in PCC 1:2:4 type B-1 foundation, suitable for 415 volts, 3 phase, 4 wire , 50 Hz completeof suitable size with and including the following:-
67[a] Aluminium strip bus bar TPN sleeve insulated mounted on epoxy insulators of capacity 1000 amps - 01 set.[b] ACB FP 800 amps fixed type, 415 volts, 50 Hz- 01 No (Incoming)[c] MCCB TP 400 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic releaseand Ics=100% of Icu - 02 No (including 01 No. spare) and MCCB TP 250 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic releaseand Ics=100% of Icu - 02 No (Outgoing)[d] Digital multifunction meter of size 96x96 mm flushmounting type-01 No, LT CTs of suitable ration-03 Nos, LED RYB indicators- Set of three, control wiring with single core copper cable FRLS wire of suitable size incl MCB for each circuit complete.[e] Earthing terminals - 02 Nos and danger notice plate - 01 No.
68Disconnecting the electrical supply, disconnecting incoming/outgoing cable connections & earhing connections, taking out the existing transformer of capacity 200 KVA to 500 KVA from the sub station buildingusing crane of suitable capacity and shifting the same to another site , reinstalling as directed, making all incoming/outgoing cable connectios and testing for satisfactory working complete all as specified and directed. Note - All T&P, vehicle for transportation of the transformer, crane etc shall be arranged by the contractor and unit rate quoted shall be deemed to include the cost of the same.
69M & L for pin type insulator porcelain, vitreous white/brown including one galvanised MS spindle nut and two GI washers of size 150 mm high 150 mm dia ball and socket type for conductors, working pressure 11000 volts complete all as specified and directed.
70M & L for single disc type insulator porcelain, vitreous white/brown insulator 255 mm dia ball and socked typeand 145 mm high assembly for tension with tension clamps for conductor working pressure 11000 volts complete all as specified and directed.
71S & F steel tubular swaged poles complete with mild steel base plate, closed at top as specified, type 410 SP-55 (11 metre long) including painting with two coats of black bitumonous paint externally up to the planted depth and internally through out and remaining external portion with two coats of aluminium paint , over a coat of red oxide primer complete all as specified and directed. NOTE: Excavation & earthwork, foundation concrete will be meaured & paid for separately under respective item(s).
72S & Flightening arrestors expulsion type complete with all fittings, transmission class, discharge capacity 65 KA 11000 volts complete all as specified and directed.
73M & L chequred rubber mat for electrical purpose ISI marked of size 1 mtr X 2 mtr and 19 mm thickness complete all as specified and directed.
74Finding of fault to 11 KV UG cable with suitablefault locator equipment & pin point the fault in the faulty cable including necessary excavation and earth work for exposing the faulty portion of the UG cable complete all as specified and directed.
75Cutting wild grass,bushes shrubs etcand cleaning of area/yard of sub station buildingscomplete all as specified and directed by Engr-in-Charge
76S& F jumpers in red/yellow/blue colour for HT lines/connections made from aluminium conductor single corePVC insulatedcable of suitable size complete including winding wires, aluminium tapes etccomplete all as specified and directed.
77Supply and fillingtransformer oil for topping up the level of oil/ new filling, having dielectric strength not less than 50 KV during filling after initial filteration,conforming to relevent IS-335 (Transformer oil to be supplied in sealed container) complete all as specified and directed.
78Material and labour for cleaning and preparation of all existing steel surfaces of straight steel tubular poles 11mtrs long for painting including mild steel cross arms, clamps and street light brackets, MS boxes etc and applying one coat of aluminium paint all round the exposed steel surfaces of existing steel tubular poles of any description and in any position above the height of 1.50 mtr from the plinth of the pole and applying one coat of synthetic enameled paint of different colours in strips of 150mm width upto the height 1.5 mtr from the plinth of pole including writing pole No and other sign works with white paint over black painted base in the pattern and style as approved by the Engineer-in-Charge complete all as specified & directed. Note : Size of black painted base for numbering shall be 100mmx25mm and the size of numbers shall be not exceeding 10cm height.
79Earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead strip 32x6mm diaby means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 5 of SSR Part-I 1991 connected to earthing test point panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1 : 3 : 6) type C1, CI pit cover and frame , charcol, salt includingearth lead protected by 40 mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete all as specified and directed. Note :- Earth lead strip 32 x 6 mm and GI 40 mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail