Rajasthan Rajya Vidyut Utpadan Nigam Limited-RVUNL has published Tender For Supply Of Contactors, Timers, Phase Failure Relays And Over Load Relays (Olr) For Electrical Circle At Katpp, Jhalawar. Submission Date for this Tender is 09-11-2023. Overload Relays Tenders in Jhalawar Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 19-Oct-2023 | DATE I | Date | 27-10-2023 |
2 | 27-Oct-2023 | NIT Extension Order II | Date | 03-11-2023 |
3 | 03-Nov-2023 | DATE 3 | Date | 09-11-2023 |
Sl. No. | Item Description |
1 | Contactor(Rail Mounted) |
2 | Contactor 6A, 415 VAC, 110 VAC Coil, 3 pole with (2NO+2NC) Aux. Contact, Model for ref:- 3TH82-62-0AF0 |
3 | Contactor 6A, 415 VAC, 415 VAC Coil, 4 pole with (2NO+2NC) Aux. Contact, Model for ref:- 3TH80-04-0AV1 |
4 | CONTACTOR 9A, 415V AC,415V AC Coil, 1NO+1NC Contacts with (2NO+2NC) Aux. Contact, Model for ref : LC1-K0910-N7 |
5 | CONTACTOR 9A, 415V AC,220/240V AC Coil, 1NO+1NC Contacts with (2NO+2NC) Aux. Contact, Model for ref : LC1-K0910-M7 |
6 | CONTACTOR 9A,415V AC, 220V DC COIL, 1NO+1NC Contacts with (2NO+2NC) Aux. Contact, Model for ref : LC1-D09-MD |
7 | CONTACTOR 9A, 415V AC, 110-120V AC COIL, 4 Pole with (2NO+2NC) Aux. Contacts, Model for ref : LC1-D09-F7 |
8 | CONTACTOR 3 pole (1 NO +1NC Contacts) WITH ON DELAY CONTACT 1NO+1 NC, 0.1-30 SEC., 9A,415V AC, 415V AC Coil, Model for ref : LC1-D09 + LA-DT2 |
9 | Contactor- 9 Amp., 415 VAC, Coil Voltage- 48 Volt AC, 2NO+2NC |
10 | Contactor- 12 Amp., 415 VAC, Coil Voltage- 48 Volt AC, 2NO+2NC |
11 | Contactor- 16 Amp., 220 VDC, Coil Voltage- 220 Volt DC, 2NO+2NC |
12 | Contactor 16A, 415 VAC, 110 VAC Coil, 3 pole with (2NO+2NC) Aux. Contact, Model for ref:- 3TA21 12-0AF |
13 | Contactor 16A, 415 VAC, 230 VAC Coil, 3 pole with (2NO+2NC) Aux. Contact |
14 | AC1, 415VAC, TP 16A ,2NO+2NC AUX contact , coil Voltage 415VAC |
15 | Contactor- 18 Amp., 415 VAC, Coil Voltage- 48 Volt AC, 2NO+2NC |
16 | Contactor- 18 Amp., 415 VAC, Coil Voltage- 220 Volt DC, 1NO+1NC |
17 | CONTACTOR 18A,415 VAC,220/240V AC Coil, 1NO+1NC Contacts with (2NO+2NC) Aux. Contact, Model for ref : LC1-D1810-M7 |
18 | Contactor- 25Amp., 415 VAC, Coil Voltage- 110 Volt AC, 2NO+2NC |
19 | Contactor- 26 Amp., 415 VAC, Coil Voltage- 220 Volt AC, 2NO+2NC |
20 | Contactor- 25 Amp., 415 VAC, Coil Voltage- 415 Volt AC, 2NO+2NC |
21 | Contactor 32A, 415 VAC, 110 VAC Coil, 3 pole with (3NO+1NC) Aux. Contact,Model for ref. :- 3TF33 00-0AF0 |
22 | Contactor- 32Amp., 415 VAC, Coil Voltage- 230 Volt AC, 2NO+2NC |
23 | Contactor- 32 Amp., 415 VAC, Coil Voltage- 415 Volt AC, 2NO+2NC |
24 | Contactor 38A, 415 VAC, 240 VAC Coil, 3 pole with (2NO+2NC) Aux. Contact, Model for ref:- 3TA13-10-0A |
25 | Contactor- 40 Amp., 415 VAC, Coil Voltage- 220 Volt AC, 1NO+1NC |
26 | Contactor- 40Amp., 415 VAC, Coil Voltage- 110 Volt AC, 2NO+2NC |
27 | Contactor 45A, 415 VAC, 110 VAC Coil, 3 pole with (2NO+2NC) Aux. Contact |
28 | Contactor- 50Amp., 415 VAC, Coil Voltage- 110 Volt AC, 2NO+2NC |
29 | AC1, 415VAC, TP 55A 1NO+1NC AUX contact , coil Voltage 415VAC |
30 | Contactor- 60 Amp., 415 VAC, Coil Voltage-220 Volt AC, 1NO+1NC |
31 | Contactor- 65 Amp., 415 VAC, Coil Voltage- 48 Volt AC, 1NO+1NC |
32 | Contactor- 65 Amp., 415 VAC, Coil Voltage- 36/42 Volt AC, 1NO+1NC |
33 | Contactor- 65 Amp., 415 VAC, Coil Voltage- 220 Volt AC, 1NO+1NC |
34 | Contactor- 65Amp., 415 VAC, Coil Voltage- 110 Volt AC, 2NO+2NC |
35 | Contactor- 75 Amp., 415 VAC, Coil Voltage- 110 Volt AC, 2NO+2NC |
36 | Contactor- 80 Amp., 415 VAC, Coil Voltage- 48 Volt AC, 1NO+1NC |
37 | AC1, 415VAC, TP 80A 1NO+1NC AUX contact , coil Voltage 415VAC |
38 | Contactor- 80Amp., 415 VAC, Coil Voltage- 110 Volt AC, 2NO+2NC |
39 | CONTACTOR 95A,415 VAC,415V AC Coil, 3 Pole, with 1NO+1NC Aux. Contacts, Model for ref : LC1-D95-N7 |
40 | Contactor- 105Amp., 415 VAC, Coil Voltage- 110 Volt AC, 2NO+2NC |
41 | Coil Voltage 220VDC , TP 110A,1NO+1NCauxiliary contact |
42 | Contactor- 110Amp., 415 VAC, Coil Voltage- 110 Volt AC, 2NO+2NC |
43 | Contactor- 150Amp., 415 VAC, Coil Voltage- 110 Volt AC, 2NO+2NC |
44 | Contactor- 170 Amp., 415 VAC, Coil Voltage- 220 Volt AC, 1NO+1NC |
45 | Contactor- 185Amp., 415 V AC, Coil Voltage- 110-220 Volt AC/DC, 2NO+2NC |
46 | AC1, 415VAC, TP 400A 1NO+1NC AUX contact , coil Voltage 415VAC |
47 | Coil Voltage 220VDC ,TP 630A, 1NO+1NCauxiliary contact |
48 | Timer (Rail Mounted) |
49 | Time delay relay electronic 0.6-6 MIN, 240 V 1.3A AC 110 VAC/DC Aux. Supply, 2 C/O on delay contacts, Model for ref:- 7PU2240-3BG320Z |
50 | Time delay relay electronic 6-60 Sec ON Delay, 240 V 1.3A AC 240 VAC Aux. Supply, 2 C/O on delay contacts, Model for ref:- 7PU2240-3BN320Z |
51 | Time delay relay electronic 0.06 Sec to 100 Hrs., 24-240 VAC/DC Aux. Supply Model for ref:- 3RP15251BW30 |
52 | Time delay relay electronic 3 Sec to 120 Sec., 24-240 VAC/DC Aux. Supply Model for ref:- 2ASDT0 |
53 | Timer 6-60 Sec. on delay 2 C/O Contacts, 240 V, 1.3 A AC, 24-240 VAC/DC Coil |
54 | Phase failure Relay (Rail Mounted) (SPP) |
55 | Under/Over Voltage Phase failure Relay W/2 C/O Contact, 240-440VAC, 3PH, 50/60 HZ Model for ref :- MINILEC ALV D2 |
56 | Under/Over Voltage Phase failure Relay W/ 2 C/O Contact, 415VAC, 3PH, 50/60 HZ Model for ref :- VSP3 |
57 | Under/Over Voltage Phase failure Relay W/ 2 C/O Contact, 240-440VAC, 3PH, 50/60 HZ Model for ref :- VSP D1 |
58 | Thermal Overload Relay |
59 | range 10A, Mounting :- Direct/Separate, Built-in Contacts:- 2NO+1NC, Trip Class:- 10 (suitable for 415VAC, TP 16 A Contactor) |
60 | range 74A, Mounting :- Direct/Separate, Built-in Contacts:- 2NO+1NC, Trip Class:- 10 (suitable for 415VAC, TP 80 A Contactor) |
61 | range 450A, Mounting :- Separate, Built-in Contacts:- 2NO+1NC, Trip Class:- 30 (suitable for 415VAC, TP 400 A Contactor) |
62 | Overload Relay |
63 | LR1D09305, CURRENT RATING- 0.63A - 1 A |
64 | LR1D09306, CURRENT RATING- 1.0A - 1.6 A |
65 | LR1D09355, CURRENT RATING- 30A - 40A |
66 | GV2P06, CURRENT RATING- 1A - 1.6 A |
67 | GV2P07, CURRENT RATING- 1.6A - 2.5 A |
68 | GV2P08, CURRENT RATING- 2.5A - 4 A |
69 | GV2P10, CURRENT RATING- 4A - 6 A |
70 | GV2P14, CURRENT RATING- 6A - 10 A |
71 | GV2P16, CURRENT RATING- 9A - 14 A |
72 | TA200DU-200, CURRENT RATING- 150A - 200A |
73 | TA 25DU 19 rating 13- 19 Amp. |
74 | 3UA52-00-2B Rating 12.5 -20 Amp. |
75 | TA 25DU 14 rating 10- 14 Amp. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy