Educational and Research Institute Government Departments Closing in 0 days TDR #39891138

Tender For Construction Of Kgbv Type-Ii At Mechuka, Shi Yomi, District Arunachal Pradesh Under Isse

Issued by Government Departments · Shi Yomi, Arunachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Oct 2023
0 days left
EMD
6.59 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Shi Yomi → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Kgbv Type-Ii At Mechuka, Shi Yomi, District Arunachal Pradesh Under Isse

BOQ

Name of Work: C/o. KGBV Type-II at Mechuka, Shi Yomi District, Arunachal Pradesh under ISSE
Sl. No. Item Description
11.SH:- Academic Building and Hostel Building Portion:-
2SH:- Development of Site: Excavation in Hill Area in Soil by Mechanical Means (Excavation in soil in hilly area by mechanical means including cutting and trimming of sideslopes and disposing of excavated earth with all lifts and lead upto 1000 metres)
3Excavation in Hilly Area in Ordinary Rock by Mechanical Means not Requiring Blasting. (Excavation in hilly area in ordinary rock not requiring ballasting by mechanical means including cutting and trimming of slopes and disposal of cut material with all lift and lead upto 1000 metres )
4SH:- School Building: Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, whenrequired, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
5Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
6Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
7Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering
8Providing and laying damp proof course 38 mm thick with cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5mm nominal size).
9Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
10Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
11Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
12Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
13Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
14Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
15Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.
16b)Column, pillars, posts and struts etc.
17c) Lintels, beams, girders, bressumers and cantilevers etc.
18d) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
19e) Stairs (excluding landings) except spiral stair cases.
20Reinforcement of RCC work including bending, binding and placing in position complete. b)Tar/ TMT steel
21Brick workwith best available local brick in superstructure 1:4 ( 1 cement : 4 fine sand).
22Extra for half brick masonry in superstructure above plinth level and up to floor two level.
23Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructure.
24Extra for half brick masonry in superstructure above plinth level and up to floor two level.
25Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
26Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws. a) 38mm thick best available local wood class - B I
27Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal
28Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. b) Ornamental grill.
29Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete a) 300 x 16 mm
30Providing and fixing Al tower bolts (barrel type) with necessary screws etc complete. a) 250 x 10 mm
31(b) 150 x 10 mm
32Providing and fixing MS handles with necessary screws etc complete. (a) 100 mm
33(b) 75 mm
34Providing and fixing MS Hooks and Eyes. (a) 200 mm
35Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
36Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : For fixed portion. 1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade SC 15)
37Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. (a) 75 mm thick
38Cement plaster skirting (up to 30 cm height) with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, including rounding of junctions with floor. a) 18 mm thick
39White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.
4012 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
4115mm thick cement plaster 1 : 3 ( 1 cement : 3 fine sand )
42Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
43Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade.
44Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
45Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
46Applying priming coat with ready mixed pink primer of approved brand and manufacture on stellwork complete.
47Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
48Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvan a) Orissa Type
49Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. (a) 100 mm dia
50Providing and fixing sand cast iron heel rest sanitary bend. (a) 100 mm dia
51Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominalsize) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight ofcover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).
52Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore
53Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). (a) 20 mm niminal bore
54Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore
55Providing and fixing brass stop cock of approved quality. (a) 15 mm nominal bore
56Providing and fixingPolythene water tabk( Sintex etc Brand)
57Providing and fixing SS railing 0.75 m high with 50mm dia steel pipetop and bottom rails5 cm x 5 cm intermediate vertical bars placed at 22.5 cm centre to centre including painting two or more coats as directed.
58Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand :6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
59Lime concrete terracing on roofs, average thickness 10 cm laid to fall with 25 mm gauge brick ballast and 50% mortar consisting of 1 lime putty and 2 surki finished with gur and belgiri treatment complete and covered with flat brick tiles grouted with cement mortar 1 : 3 (1 cement : 3 fine sand) over 12 mm layer cement mortar 1 : 3 (1 cement : 3 fine sand) and finished neat.
60Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm
61Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design/200 mm dia SW pipes
62Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete/200 mm dia SW pipes
63Add carrying Charges (as per Annexure-A)
64ELECTRIFICAL WORKS POINT WIRING Point wiring in PVC conduit, with modular type switch. Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FR PVC insultated copper conductor single core cable in surface/recessed PVC conduit,with modular switch, modular switch, suitable size G.I. box and earthing the point with 1.5 sq. mm.FR PVC insulated copper conductor single core cable etc. as required. Group A
65Group B
66Group C
67Wiring for light/ power plug with 2X4 sq. mm FR PVC insulatedcopper conductor single core cable in surface/ recessed mediumclass PVC conduit along with 1 No 4 sq. mm FR PVC insulatedcopper conductor single core cable for loop earthing as required.
68Wiring for circuit/ submain wiring along with earth wire with thefollowing sizes of FR PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (5A Plug).
692 x 4 sq. mm + 1 x 4 sq. mm earth wire(for power point).
70Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
7125 mm
7232 mm
7350 mm
74TV Cable in existing Conduit :- Supplying and drawing co-axial TV Cable RG - 6 grade,0.7 mm solid copper conductor PEinsulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required.S/F modular type switch/socket :- Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 Amps Switch
7515/16 Amps Switch
765/6 Amps Socket
7715/16 Amps socket outlet
78Telephone socket outlet
79Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required
80Supplying and fixing 3 pin, 5 amp ceiling rose on the existingjunction box/ wooden block including connection etc as required
81Supplying and fixing brass batten/ angle holder includingconnection etc. as required.
82Erection of wall bracket /ceiling fittings of all sizes and shapescontaining upto two GLS lamps per fitting, complete with allaccessories including connection etc. as required.
83Supplying and fixing call bell/ buzzer suitable for single phase,230 volts, complete as required
84Installation, testing and commissioning of pre-wired, fluorescentfitting/ compact fluorescent fitting of all types, with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required.
85Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover onthe fan box etc. as required.5/6 amps switch
86CHAPTER 2 – MCCB, MCB & DB’S Providing and fixing following capacity TP&N disconnector fuseswitch unit inside the existing panel board with ISI marked HRCfuses including drilling holes in cubicle panel, makingconnections, etc. as required. 32 Amp TP&N
8763 Amp TP&N
88Providing and fixing following rating and breaking capacity MCCBin existing cubicle panel board including drilling holes in cubiclepanel, making connections, etc. as required. 100 Amp
89125 Amp
90Providing and fixing following rating and breaking capacity MCCBin existing cubicle panel board including drilling holes in cubiclepanel, making connections, etc. as required. 4 way (4 + 12), Double door
916 way (4 + 18), Double door
92EARTHING Copper Plate Electrode :- Earthing with Copper plate 600 x 600 x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc.(but withoutcharcoal or coke and salt) complete as required.
93Providing and laying earth connection from earth electrode with4.00 mm dia copper wire in 15 mm dia G.I. pipe from earthelectrode including connection with copper thimble excavationand re-filling as required
94Providing and fixing 25 mm X 5 mm copper strip on surface or inrecess for connections etc. as required.
95Fittings: Supplying of 1200mm AC sweep ceiling Fan( Orient/Usha make)
96Modular fan regulator ( anchor/Roma step make)
9720 Wats LED Bulbs ( bajaj/ Phylips make)
9815 Wats LED Bulbs ( bajaj/ Phylips make)
99Fluorescent Tube set fitting/ ( bajaj/ Phylips make)
100FurnitureProviding & supplying offurnishing itemsas per the standard specification and direction of Engineer-in-charge. WoodenBench 3.3\"x1.3\"x2\" size
101WoodenDesk-3.3\"x1.3\"x2.6\" size
102Wooden writing Table 3\"x2\"x2.6\" size
103Woodenarmedchair
104Water filter (20 Ltr)
105Dustbin
106SH:- Hostel Building Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, whenrequired, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
107Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
108Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
109Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering
110Providing and laying damp proof course 38 mm thick with cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5mm nominal size).
111Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
112Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
113Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
114Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
115Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
116Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
117Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.
118b)Column, pillars, posts and struts etc.
119c) Lintels, beams, girders, bressumers and cantilevers etc.
120d) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
121e) Stairs (excluding landings) except spiral stair cases.
122Reinforcement of RCC work including bending, binding and placing in position complete. b)Tar/ TMT steel
123Brick workwith best available local brick in superstructure 1:4 ( 1 cement : 4 fine sand).
124Extra for half brick masonry in superstructure above plinth level and up to floor two level.
125Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructure.
126Extra for half brick masonry in superstructure above plinth level and up to floor two level.
127Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
128Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws.a) 38mm thick best available local wood class - B I
129Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal
130Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. b) Ornamental grill.
131Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete a) 300 x 16 mm
132Providing and fixing Al tower bolts (barrel type) with necessary screws etc complete. a) 250 x 10 mm
133(b) 150 x 10 mm
134Providing and fixing MS handles with necessary screws etc complete. (a) 100 mm
135(b) 75 mm
136Providing and fixing MS Hooks and Eyes. (a) 200 mm
137Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
138Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : For fixed portion. 1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade SC 15)
139Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. (a) 75 mm thick
140Cement plaster skirting (up to 30 cm height) with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, including rounding of junctions with floor. a) 18 mm thick
141White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.
14212 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
14315mm thick cement plaster 1 : 3 ( 1 cement : 3 fine sand )
144Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
145Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade.
146Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
147Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
148Applying priming coat with ready mixed pink primer of approved brand and manufacture on stellwork complete.
149Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
150Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvan a) Orissa Type
151Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. (a) 100 mm dia
152Providing and fixing sand cast iron heel rest sanitary bend.(a) 100 mm dia
153Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominalsize) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight ofcover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).
154Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore
155Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). (a) 20 mm niminal bore
156Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore
157Providing and fixing brass stop cock of approved quality. (a) 15 mm nominal bore
158Providing and fixingPolythene water tabk( Sintex etc Brand)
159Providing and fixing SS railing 0.75 m high with 50mm dia steel pipetop and bottom rails5 cm x 5 cm intermediate vertical bars placed at 22.5 cm centre to centre including painting two or more coats as directed.
160Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand :6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
161Lime concrete terracing on roofs, average thickness 10 cm laid to fall with 25 mm gauge brick ballast and 50% mortar consisting of 1 lime putty and 2 surki finished with gur and belgiri treatment complete and covered with flat brick tiles grouted with cement mortar 1 : 3 (1 cement : 3 fine sand) over 12 mm layer cement mortar 1 : 3 (1 cement : 3 fine sand) and finished neat.
162Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm
163Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design/200 mm dia SW pipes
164Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete/200 mm dia SW pipes
165Add carrying Charges (as per Annexure-A)
166ELECTRIFICAL WORKS POINT WIRING Point wiring in PVC conduit, with modular type switch. Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FR PVC insultated copper conductor single core cable in surface/recessed PVC conduit,with modular switch, modular switch, suitable size G.I. box and earthing the point with 1.5 sq. mm.FR PVC insulated copper conductor single core cable etc. as required. Group A
167Group B
168Group C
169Wiring for light/ power plug with 2X4 sq. mm FR PVC insulatedcopper conductor single core cable in surface/ recessed mediumclass PVC conduit along with 1 No 4 sq. mm FR PVC insulatedcopper conductor single core cable for loop earthing as required.
170Wiring for circuit/ submain wiring along with earth wire with thefollowing sizes of FR PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (5A Plug).
1712 x 4 sq. mm + 1 x 4 sq. mm earth wire(for power point).
172Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
17325 mm
17432 mm
17550 mm
176TV Cable in existing Conduit :- Supplying and drawing co-axial TV Cable RG - 6 grade,0.7 mm solid copper conductor PEinsulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required.S/F modular type switch/socket :-Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 Amps Switch
17715/16 Amps Switch
1785/6 Amps Socket
17915/16 Amps socket outlet
180Telephone socket outlet
181Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required
182Supplying and fixing 3 pin, 5 amp ceiling rose on the existingjunction box/ wooden block including connection etc as required
183Supplying and fixing brass batten/ angle holder includingconnection etc. as required.
184Erection of wall bracket /ceiling fittings of all sizes and shapescontaining upto two GLS lamps per fitting, complete with allaccessories including connection etc. as required.
185Supplying and fixing call bell/ buzzer suitable for single phase,230 volts, complete as required
186Installation, testing and commissioning of pre-wired, fluorescentfitting/ compact fluorescent fitting of all types, with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required.
187Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover onthe fan box etc. as required.5/6 amps switch
188CHAPTER 2 – MCCB, MCB & DB’S Providing and fixing following capacity TP&N disconnector fuseswitch unit inside the existing panel board with ISI marked HRCfuses including drilling holes in cubicle panel, makingconnections, etc. as required. 32 Amp TP&N
18963 Amp TP&N
190Providing and fixing following rating and breaking capacity MCCBin existing cubicle panel board including drilling holes in cubiclepanel, making connections, etc. as required. 100 Amp
191125 Amp
192Providing and fixing following rating and breaking capacity MCCBin existing cubicle panel board including drilling holes in cubiclepanel, making connections, etc. as required. 4 way (4 + 12), Double door
1936 way (4 + 18), Double door
194EARTHING Copper Plate Electrode :- Earthing with Copper plate 600 x 600 x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc.(but withoutcharcoal or coke and salt) complete as required.
195Providing and laying earth connection from earth electrode with4.00 mm dia copper wire in 15 mm dia G.I. pipe from earthelectrode including connection with copper thimble excavationand re-filling as required
196Providing and fixing 25 mm X 5 mm copper strip on surface or inrecess for connections etc. as required.
197Fittings Supplying of 1200mm AC sweep ceiling Fan( Orient/Usha make)
198Modular fan regulator ( anchor/Roma step make)
19920 Wats LED Bulbs ( bajaj/ Phylips make)
20015 Wats LED Bulbs ( bajaj/ Phylips make)
201Fluorescent Tube set fitting/ ( bajaj/ Phylips make)
202Providing & supplying offurnishing itemsas per the standard specification and direction of Engineer-in-charge.WoodenCoat 6\"x3\" sizex2\"
203Dining table 6\" x4\"x 2.5\" size
204Dining Chair
205Wooden table 8\"x5x3\" size
206Wooden stool 1,x1x,3\"
207Steel Book shelf -44x1.5\"x6\" size
208Wooden writing Table 3\"x2\"x2.6\" size
209Woodenarmedchair
210SH:- septic tank Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning to
211Providing and laying cement concrete 1 : 4: 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : Foundations and plinth
212Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in :1:2:4
213Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
214Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth an
215Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars.
216Centring and shuttering including strutting, propping etc and removal of form work for : a)walls
217b)S/floor
21812 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
219Neat cement punning.
220Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.100mm Dia pipe
221Providing and fixing sand cast iron heel rest sanitary bend.100mm
222Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.150 mm dia SW pipes b) 150 mm dia SW pipes
223Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design.b) 150 mm dia SW pipes
224Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design..
225Add Carriage of Materials of materials ( as perAnnexure-A)
226SH:- Boundary wall Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
227Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
228Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
229Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
230Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
231Centring and shuttering including strutting, propping etc and removal of form work for : b) Column, pillars, posts and struts etc.
232c) Lintels, beams, girders, bressumers and cantilevers etc.
233Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars.
234Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
235Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
236Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level.
237Providing and fixing MS angle Iron post 50 x50x6mm size in cementconcrete colomn 1:2:4 with two way of 35 cm on top and 45 cm under coloumn and 30 cm open with 8mm dia holes at c/c 125 mm forfixing od barbed wire with GI stapples including1/4 ofof red oxide primer as per direction of enginner in charge
23812 mm thick cement plaster (1:4 1: cement ,4: fine sand)
23915 mm thick cement plaster (1:4 1: cement ,4: fine sand)
240Applying one coat of cement primer of approved brand and manufacture on wall surface.
241Providing and fixing GI barbed wire with GIstapplesin MS angle iron fencing cost
242Providing and fixing MS gate with locking and wheel system includingpriming coat and painting i/c all fittings
243Add carrying Charge
244Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.

AI Tender Summary

OUR REF NO 39891138
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 13-10-2023
Authority
Authority Name Department Of Education
Work Description Construction Of Kgbv Type-Ii At Mechuka, Shi Yomi, District Arunachal Pradesh Under Isse
Basic Detail
Tender No EDN(EW)/Plg-015/2021/91
Bidding Type Tender
Location
City Shi Yomi
State Arunachal Pradesh
Key Dates
Publish Date 27 Sep 2023
Submission Date 13 Oct 2023
Open Date 13 Oct 2023
Finance
Tender Value Ref. Documents
Tender Fee 5000
EMD 6.59 Lakhs
Exemption Not Available
Document List
a7ec12cc-e91f-4a91-ab96-eae434eaa3cc.html
BOQ_1548.xls
Mechuka_SBD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 27, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 13, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 13, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

a7ec12cc-e91f-4a91-ab96-eae434eaa3cc.html

xls

BOQ_1548.xls

pdf

Mechuka_SBD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender