Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-10-2023 | ADDENDUM | Other | 31-10-2023 |
| 2 | 25-10-2023 | DATE1 | Date | 31-10-2023 |
| Sl. No. | Item Description |
| 1 | Removinggrass,gazergrassand disposingoffoutofbuildingpremisesincludingmaking clean the ground by shovel and phavaras excetra. complete. |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingthe excavatedmaterialuptoadistanceof50meter.beyondthebuildingareaand stackingandspreadingas directed,dewatering,preparingthebedforthefoundationand necessary back filling, ramillimetering, watering including shoring and strutting excetra. complete. (Lift upto 1.5 meter.) By Mechanical Means |
| 3 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramillimetering, watering including shoring and strutting excetra. complete. (Lift from 1.5meter to 3.0meter) By Mechanical Means |
| 4 | Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramillimetering, wateringincludingshoringandstruttingexcetra.complete.(Liftupto1.50meter)ByMechanical Means |
| 5 | ExcavationforfoundationinHardmurum andbouldersincludingremoving theexcavated material upto adistanceof50metres,beyondthebuildingareaandstackingandspreadingasdirected, dewatering, preparingthebed forthefoundation and necessarybackfilling, ramillimetering, watering including shoring and strutting excetra. complete. (Lift from 1.5 meter to 3.0 meter.) By Mechanical Means |
| 6 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling withavailable earth/murum, ramillimetering ,watering including shoring andstrutting excetra. complete. (Lift from 1.5meter To 3.0 meter.) By Mechanical Means |
| 7 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling withavailable earth/murum, ramillimetering ,watering including shoring andstrutting excetra. complete. (Lift from 3.0meter To 4.5 meter.) By Mechanical Means |
| 8 | Excavation for foundation in Hard-rock by blasting including trimillimetering and leveling the bed bychisellingwherenecessaryandremovingtheexcavatedmaterialandstackingitin measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum watering, ramillimetering excetra. complete. (Lift from 1.5meter To 3.0 meter) By Mechanical Means |
| 9 | Excavation for foundation in Hard-rock by blasting including trimillimetering and leveling the bed bychisellingwherenecessaryandremovingtheexcavatedmaterialandstackingitin measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum watering, ramillimetering excetra. complete. (Lift from 3 meter To 4.5meter) By Mechanical Means |
| 10 | Excavation for foundation in Hard-rock by blasting including trimillimetering and leveling the bed bychisellingwherenecessaryandremovingtheexcavatedmaterialandstackingitin measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum watering, ramillimetering excetra. complete. (Lift from 4.5 meter To 6 meter) By Mechanical Means |
| 11 | Providing preconstructional antitermite treatment as per Indian Standards 6313 (Part-II) by treating thebottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percentofchlorophyrifos persquaremeterofsurfaceareacovering10yearsguaranteeon bond paper. |
| 12 | Providing preconstructional antitermite treatment as perIndian Standards 6313 (Part-II) treatment bytreatingthe backfill in imillimeterediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper. |
| 13 | ProvidingpreconstructionalantitermitetreatmentasperIndian Standards6313(Part-II)bytreatingthetopsurface of plinthfillingattherateof5litresofemulsionconcentrateat1.0percentof clorophyrifosper squaremetre of surface area covering ten years guarantee on bond paper. |
| 14 | Fillinginplinthandfloorswith approved excavatedmaterialin15centimeter.to20centimeter.Layers including watering and compacting excetra. complete. |
| 15 | Fillinginplinthandfloorswithcontractors material/broughtfromoutsideandapprovedbyEngineer incharge inlayersof15centimeter to20centimeterincludingwateringandcompaction excetra.complete. |
| 16 | Providingdry/trap/granite/quartzite/gneissrubblestonesoling15centimeterto20 centimeter thick including hand packing and compacting excetra. complete. |
| 17 | Providingsoling using80 milimeter sizetrap metal in 15 cm. layer includingfilling voidswithCrushed sand/grit, ramillimetering, watering excetra. complete. |
| 18 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/quartzite/ gneiss metal for foundation and bedding including bailing out water, Steelcentering,formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredand curingcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Typemixer/concreteBatchmixplant(Panmixer)excetra.complete. Withfineaggregate(CrushedsandVSI Grade) |
| 19 | Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneissmetalforstepsincludingsteelcentering,formwork,laying/pumping,compacting, rougheningthemifspecial finish is tobeprovided,finishinguneven andhoneycombedsurface and curing excetra. complete. The Cement Mortar 1:3plaster is consideredfor rendering uneven andhoneycombed surface,only.Newlylaidconcreteshallbecoveredby gunny bag, plastic, tarpaulin excetra. (Wooden centering will not be allowed.),with fullyautomaticmicroprocessorbasedPLCwithSCADA enabled reversible Drum Type mixer/concreteBatchmixplant(Panmixer)excetra.complete.Withfine aggregate(Crushed sand VSI Grade) |
| 20 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/quartzite/gneissmetalforReinforced Cement Concreteworkinfoundationslike raft,strip foundations,grillage and footings of Reinforced Cement Concrete columns and steel stanchions excetra. including bailing out water,Steel centering,formwork,cover blocks,laying/pumping,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) excetra. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra. complete. With fine aggregate (Crushed sand VSI Grade) |
| 21 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-30oftrap/granite/quartzite/gneissmetalforReinforced Cement Concreteworkinfoundationslike raft,strip foundations,grillage and footings ofReinforced Cement Concretecolumnsandsteelstanchionsexcetra.columnsasperdetaileddesignsanddrawingorasdirected includingSteel centering formwork, coverblocks laying/pumping,compaction finishing the formed surfaceswithcementmortar1:3ofsufficientminimum thickness to give a smooth and even surface or rougheningifspecialfinishistobeprovidedandcuringexcetra.complete.(Excludingreinforcementand structural steel). with fully automatic microprocessorbasedPLCwithSCADAenabledreversibleDrum Typemixer/concrete Batchmix plant (Pan mixer) excetra. complete. Withfine aggregate (CrushedsandVSI Grade) Basement floor |
| 22 | Ground floor |
| 23 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-30oftrap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering,formwork,coverblocks,laying/pumping,compactionfinishingtheformedsurfaceswithcement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumTypemixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground floor |
| 24 | First floor |
| 25 | Second floor |
| 26 | Third floor |
| 27 | Fifth floor |
| 28 | Sixth floor |
| 29 | Seventh floor |
| 30 | Eighth floor |
| 31 | Nineth floor |
| 32 | Tenth floor |
| 33 | Eleventh floor |
| 34 | Twelth floor |
| 35 | Terrace floor |
| 36 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-35oftrap/granite/quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering,formwork,coverblocks,laying/pumping,compactionfinishing the formedsurfaceswithcement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing excetra. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCAD Aenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra. complete. With fine aggregate (Crushed sand VSI Grade) Basement floor |
| 37 | Ground floor |
| 38 | First floor |
| 39 | Second floor |
| 40 | Third floor |
| 41 | Fourth floor |
| 42 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-40oftrap/granite/quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering,formwork,coverblocks,laying/pumping,compactionfinishing the formedsurfaceswithcement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing excetra. complete,(Excluding reinforcement and structural steel).with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumTypemixer/concrete Batch mix plant (Pan mixer) excetra. complete. With fine aggregate (Crushed sand VSI Grade) Ground floor |
| 43 | First floor |
| 44 | Second floor |
| 45 | Third floor |
| 46 | Fourth floor |
| 47 | Fifth floor |
| 48 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or asdirected including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening thesurfaceifspecialfinishistobeprovidedand curingexcetra. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra. complete. With fine aggregate (Crushedsand VSI Grade) Basement Floor |
| 49 | Ground floor |
| 50 | First floor |
| 51 | Second floor |
| 52 | Third floor |
| 53 | Fourth floor |
| 54 | Fifth floor |
| 55 | Sixth floor |
| 56 | Seventh floor |
| 57 | Eighth floor |
| 58 | Nineth floor |
| 59 | Tenth floor |
| 60 | Eleventh floor |
| 61 | Twelveth floor |
| 62 | Terrace floor |
| 63 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-30oftrap/granite/quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or asdirected including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening thesurfaceifspecialfinishistobeprovidedandcuringexcetra. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra. complete. With fine aggregate (Crushed sand VSI Grade) Ground floor |
| 64 | First floor |
| 65 | Second floor |
| 66 | Third floor |
| 67 | Fifth floor |
| 68 | Sixth floor |
| 69 | Seventh floor |
| 70 | Eighth floor |
| 71 | Nineth floor |
| 72 | Tenth floor |
| 73 | Eleventh floor |
| 74 | Twelveth floor |
| 75 | Terrace floor |
| 76 | Providing and laying Cast in situ/Ready Mixcement concrete M-35 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concretebeamsandlintelsasperdetaileddesignsanddrawingsorasdirectedincluding steelcentering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be providedandcuringexcetra.complete.(Excludingreinforcement and structural steel).with fully automatic microprocessorbasedPLCwith SCADAenabledreversibleDrumTypemixer/concreteBatchmix plant(Panmixer)excetra. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor |
| 77 | Ground floor |
| 78 | First floor |
| 79 | Second floor |
| 80 | Third floor |
| 81 | Fourth floor |
| 82 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-40oftrap/granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or asdirected including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening thesurfaceifspecialfinishistobeprovidedand curingexcetra. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra. complete. With fine aggregate (Crushedsand VSI Grade) Ground floor |
| 83 | First floor |
| 84 | Second floor |
| 85 | Third floor |
| 86 | Fourth floor |
| 87 | Fifth floor |
| 88 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-30oftrap/granite/ quartzite/ gneiss metalforReinforced Cement Concrete slabsand landings as perdetailed designsand drawingsincludingsteelcentering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing excetra. complete,(Excluding reinforcement and structural steel).with fully automatic microprocessorbasedPLCwithSCADAenabledreversibleDrum Typemixer/concreteBatchmixplant (Pan mixer) excetra. complete. With fine aggregate (Crushed sand VSI Grade) Ground floor |
| 89 | First floor |
| 90 | Second floor |
| 91 | Third floor |
| 92 | Fifth floor |
| 93 | Sixth floor |
| 94 | Seventh floor |
| 95 | Eighth floor |
| 96 | Nineth floor |
| 97 | Tenth floor |
| 98 | Eleventh floor |
| 99 | Twelevth floor |
| 100 | Terrace floor |
| 101 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-35oftrap/granite/ quartzite/ gneiss metalforReinforced Cement Concrete slabsand landings as perdetailed designsand drawingsincludingsteelcentering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to beprovidedandcuringexcetra.complete,(Excludingreinforcementandstructuralsteel).withfully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor |
| 102 | Ground floor |
| 103 | First floor |
| 104 | Second floor |
| 105 | Third floor |
| 106 | Fourth floor |
| 107 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-40oftrap/quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawingsoras directedincludingsteelcentering,plywood/steelformwork,steelprops, laying/pumping,compaction, finishinguneven and honeycombed surfacewith cement morta1:3 ofsufficientminimumthicknesstogivea smooth and even surface or roughening the surface if special finish is to be provided and curing excetra. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra.) with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrum Type mixer/concreteBatchmixplant(Panmixer)excetra.complete.Withfineaggregate(Crushed sand VSI Grade) Ground floor |
| 108 | First floor |
| 109 | Second floor |
| 110 | Third floor |
| 111 | Fourth floor |
| 112 | Fifth floor |
| 113 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-30oftrap/quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawingsoras directedincludingsteelcentering,plywood/steelformwork,steelprops, laying/pumping,compaction, finishinguneven and honeycombed surfacewithcement morta1:3 ofsufficientminimumthicknesstogivea smooth and even surface or roughening the surface if special finish is to be provided and curing excetra. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra.) with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrum Type mixer/concreteBatchmixplant(Panmixer)excetra.complete.Withfineaggregate(Crushed sand VSI Grade) Basement floor |
| 114 | Ground floor |
| 115 | First floor |
| 116 | Second floor |
| 117 | Third floor |
| 118 | Fourth floor |
| 119 | Fifth floor |
| 120 | Sixth floor |
| 121 | Seventh floor |
| 122 | Eighth floor |
| 123 | Nineth floor |
| 124 | Tenth floor |
| 125 | Eleventh floor |
| 126 | Twelveth floor |
| 127 | Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ granite/quartzite/ gneissmetalforReinforced Cement Concretepardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete. (Excludingreinforcementand structuralsteel).withfullyautomatic microprocessor based PLC with SCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer)excetra.complete. Withfineaggregate(Crushed sand VSI Grade) Ground floor |
| 128 | First floor |
| 129 | Second floor |
| 130 | Third floor |
| 131 | Fourth floor |
| 132 | Fifth floor |
| 133 | Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/quartzite/ gneissmetalforReinforced Cement Concretepardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete. (Excludingreinforcementand structuralsteel).withfullyautomatic microprocessor based PLC with SCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer)excetra.complete. Withfineaggregate(Crushed sand VSI Grade) Basement floor |
| 134 | Ground floor |
| 135 | First floor |
| 136 | Second floor |
| 137 | Third floor |
| 138 | Fourth floor |
| 139 | Fifth floor |
| 140 | Sixth floor |
| 141 | Seventh floor |
| 142 | Eighth floor |
| 143 | Nineth floor |
| 144 | Tenth floor |
| 145 | Eleventh floor |
| 146 | Twelveth floor |
| 147 | Terrace floor |
| 148 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-40oftrap/granite/ quartzite/ gneiss metalforReinforced Cement Concrete slabsand landings as perdetailed designsand drawingsincludingsteelcentering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing excetra. complete,(Excluding reinforcement and structural steel).with fully automatic microprocessorbasedPLCwithSCADAenabledreversibleDrum Typemixer/concreteBatchmixplant (Pan mixer) excetra. complete. With fine aggregate (Crushed sand VSI Grade) Ground floor |
| 149 | First floor |
| 150 | Second floor |
| 151 | Third floor |
| 152 | Fourth floor |
| 153 | Fifth floor |
| 154 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/quartzite/ gneissmetalforReinforced Cement Concretepardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete. (Excludingreinforcementand structuralsteel).withfullyautomatic microprocessor based PLC with SCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer)excetra.complete. Withfineaggregate(Crushed sand VSI Grade) Ground floor |
| 155 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/quartzite/ gneissmetalforReinforced Cement Concretecoping to plinthorparapetandsill ofdoors andwindows mouldedas perdetailed drawingsorchamferedasapprovedbytheEngineerincludingsteelcentering, formwork, cover blocks, laying/pumping, compacting , curing , finishing androughening them if special finish is to be provided and curing complete. (Excludingreinforcement and structural steel).with fully automatic microprocessorbasedPLCwith SCADAenabledreversibleDrumTypemixer/concreteBatchmix plant(Panmixer)excetra. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor |
| 156 | Ground floor |
| 157 | First floor |
| 158 | Second floor |
| 159 | Third floor |
| 160 | Fourth floor |
| 161 | Fifth floor |
| 162 | Sixth floor |
| 163 | Seventh floor |
| 164 | Eighth floor |
| 165 | Nineth floor |
| 166 | Tenth floor |
| 167 | Eleventh floor |
| 168 | Twelveth floor |
| 169 | Terrace floor |
| 170 | Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concretechajjaasperdetaileddesignanddrawingsincludingsteelcentering,formwork,coverblocks, laying/pumping,compactingand rougheningthesurfaceif specialfinishistobeprovidedandcuring complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLC with SCADAenabled reversible DrumType mixer/ concrete Batch mix plant (Pan mixer) excetra. complete.Withfineaggregate (Crushed sand VSI Grade) Ground floor |
| 171 | First floor |
| 172 | Second floor |
| 173 | Third floor |
| 174 | Fourth floor |
| 175 | Fifth floor |
| 176 | Sixth floor |
| 177 | Seventh floor |
| 178 | Eighth floor |
| 179 | Nineth floor |
| 180 | Tenth floor |
| 181 | Eleventh floor |
| 182 | Twelveth floor |
| 183 | Terrace floor |
| 184 | Providing and fixing in position Thermo Mechanically Twisted - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels,chajjas, lintels pardis, copings, fins, arches excetra. as per detailed designs, drawings andschedules.including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Basement Floor |
| 185 | Ground floor |
| 186 | First floor |
| 187 | Second floor |
| 188 | Third floor |
| 189 | Fourth floor |
| 190 | Fifth floor |
| 191 | Sixth floor |
| 192 | Seventh floor |
| 193 | Eighth floor |
| 194 | Nineth floor |
| 195 | Tenth floor |
| 196 | Eleventh floor |
| 197 | Twelveth floor |
| 198 | Terrace floor |
| 199 | Providing fly ash brick masonry with conventional / India Standard type fly ash bricksin Cement mortar 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding excetra. complete. Basement Floor |
| 200 | Ground floor |
| 201 | ProvidingAutoclavedAeratedConcreteBlockmasonaryof conforming to India Standard :2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding excetra. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Basement Floor |
| 202 | Ground floor |
| 203 | First floor |
| 204 | Second floor |
| 205 | Third floor |
| 206 | Fourth floor |
| 207 | Fifth floor |
| 208 | Sixth floor |
| 209 | Seventh floor |
| 210 | Eighth floor |
| 211 | Nineth floor |
| 212 | Tenth floor |
| 213 | Eleventh floor |
| 214 | Twelveth floor |
| 215 | Terrace floor |
| 216 | Providing Autoclaved Aerated Concrete Block masonary of conformingto Indian Standard :2185(Part3)-1984in extrafinejointingmortaroffixoblockofUltraTechor equivalent in Half brick thick wall including strikingjoints,rakingoutjointsand scaffolding excetra. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Ground floor |
| 217 | First floor |
| 218 | Second floor |
| 219 | Third floor |
| 220 | Fourth floor |
| 221 | Fifth floor |
| 222 | Sixth floor |
| 223 | Seventh floor |
| 224 | Eighth floor |
| 225 | Nineth floor |
| 226 | Tenth floor |
| 227 | Eleventh floor |
| 228 | Twelveth floor |
| 229 | Providingsandfacedplasterexternallyincementmortarusingapprovedscreenedsand,inallpositions including base coat of 15 milimeterthick in cement mortar 1:4 using waterproofingcompoundat 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoat roughtoreceivethesandfacedtreatment6to8millimeter thickin cementmortar1:4finishingthesurface bytakingoutgrainsandcuringforfourteendays scaffolding excetra.complete. Basement Floor |
| 230 | Ground floor |
| 231 | Providing and applying gypsum plaster ( with Gypsum material) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding excetra.complete. Basement Floor |
| 232 | Ground floor |
| 233 | First floor |
| 234 | Second floor |
| 235 | Third floor |
| 236 | Fourth floor |
| 237 | Fifth floor |
| 238 | Sixth floor |
| 239 | Seventh floor |
| 240 | Eighth floor |
| 241 | Nineth floor |
| 242 | Tenth floor |
| 243 | Eleventh floor |
| 244 | Twelveth floor |
| 245 | Terrace floor |
| 246 | ProvidingwaterproofplasterinW.C.andbath 12millimeter thickfordadoincementmortar1:3withneat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing excetra. complete.(Excluding Tiles) (As directed by Engineer in Charge) Ground floor |
| 247 | First floor |
| 248 | Second floor |
| 249 | Third floor |
| 250 | Fourth floor |
| 251 | Fifth floor |
| 252 | Sixth floor |
| 253 | Seventh floor |
| 254 | Eighth floor |
| 255 | Nineth floor |
| 256 | Tenth floor |
| 257 | Eleventh floor |
| 258 | Twelveth floor |
| 259 | Providinginternalcementplaster12millimeterthickinsinglecoatincementmortar1:3without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing excetra. complete. Ground floor |
| 260 | First floor |
| 261 | Second floor |
| 262 | Third floor |
| 263 | Fourth floor |
| 264 | Fifth floor |
| 265 | Sixth floor |
| 266 | Seventh floor |
| 267 | Eighth floor |
| 268 | Nineth floor |
| 269 | Tenth floor |
| 270 | Eleventh floor |
| 271 | Twelveth floor |
| 272 | Terrace floor |
| 273 | Providing internal / external 20 millimeterthick Ready Mix plaster confirming to Indian Standard :4031(Part-4) 1988 and IS 383- 1970 ina single coat using Cement mortar of proportion1:4containing special type of polymeradditives about 0.4%, to all type of surfaces in all positions including scaffolding and curing complete Basement Floor |
| 274 | Ground floor |
| 275 | First floor |
| 276 | Second floor |
| 277 | Third floor |
| 278 | Fourth floor |
| 279 | Fifth floor |
| 280 | Sixth floor |
| 281 | Seventh floor |
| 282 | Eighth floor |
| 283 | Nineth floor |
| 284 | Tenth floor |
| 285 | Eleventh floor |
| 286 | Twelveth floor |
| 287 | Terrace floor |
| 288 | Providing and fixing chicken mesh of 22 gauge, with about 30 centimeter. width at the junction of Reinforced Cement Concretemembers andbrickwork,ofapprovedqualityincludingfixing meshinpositionby necessary drilling in concrete /Burn.Brick.masonry and or tying by binding wire excetra. complete. Basement Floor |
| 289 | Ground floor |
| 290 | First floor |
| 291 | Second floor |
| 292 | Third floor |
| 293 | Fourth floor |
| 294 | Fifth floor |
| 295 | Sixth floor |
| 296 | Seventh floor |
| 297 | Eighth floor |
| 298 | Nineth floor |
| 299 | Tenth floor |
| 300 | Eleventh floor |
| 301 | Twelveth floor |
| 302 | Terrace floor |
| 303 | ProvidingandapplyingRoyaleLuxuryEmulsionofapprovedmakeoninternalwallsurfaceas detailed belowScrappingforsurfacewithemerypaperandwipecleanforarea. wall primer withbrushby adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dryfor 6 to8 hoursAfter applying acrylic wall putty with appropriate prpportion of water of allow to dry for period of4to6hours ofactivity.Scrappingwithemerypaper andwipecleanApplying paints Royale Luxury emulsion 1st coatwithbrushwatercontentwater40to45%or65to70%byroleApplyingpaintsRoyaleluxury emulsion 2nd coat with brush with water content 40 to 45%or 65 to 70 % by roller. (With prior approval of S.E.) Basement Floor |
| 304 | Ground floor |
| 305 | First floor |
| 306 | Second floor |
| 307 | Third floor |
| 308 | Fourth floor |
| 309 | Fifth floor |
| 310 | Sixth floor |
| 311 | Seventh floor |
| 312 | Eighth floor |
| 313 | Nineth floor |
| 314 | Tenth floor |
| 315 | Eleventh floor |
| 316 | Twelveth floor |
| 317 | Terrace floor |
| 318 | ProvidingandapplyingtwocoatsApexUltimaPuranatureAnti-PollutionOrequivalentapprovedbrand, paint should decomposes organic substances and inorganic gases(NOx, VOC‘s, CO, SOx, formaldehydes,excetra.)inpresenceofnaturalorartificiallight.ItcontainsGrapheneandnanoparticlesof titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recomillimeterendedapplicatorandheshouldbeabletofurnishstagewiseonsitetechnicalreportsfromthe concerned company technologist. Basement Floor |
| 319 | Ground floor |
| 320 | First floor |
| 321 | Second floor |
| 322 | Third floor |
| 323 | Fourth floor |
| 324 | Fifth floor |
| 325 | Sixth floor |
| 326 | Seventh floor |
| 327 | Eighth floor |
| 328 | Nineth floor |
| 329 | Tenth floor |
| 330 | Eleventh floor |
| 331 | Twelveth floor |
| 332 | Terrace floor |
| 333 | Providing andapplying twocoatsofHighAlbedopainthavingminimum SolarReflective Index (SRI) 108(withsolarreflectance&thermalemittancetestedasperASTM)C1549andASTM C 1371 respectively,VOClessthan10cc/gm.Thecoatingthicknessandthe methodology of application shall strctly as per manufacturer\"s specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus excetra, washing with water all complete.The contractor shall give guarantee for the performanceofSRIandalsothedurabitityofcoating,allcompleteasper directionof Engineer - in- incharge. First floor |
| 334 | Third floor |
| 335 | Fourth floor |
| 336 | Terrace floor |
| 337 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laidinrequiredslopetodrainthewaterforanyspanaftercleaningthebasesurface.Applyingacoatof cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in Cement Mortar1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layerfor3days,applyingcementslurryoverthislayerjointsofbrickbatswithCement Mortar1:3admixedwith approved water proofing compound and finally top finishing with average 20 millimeter. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed withapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300millimeter x 300 millimeter. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldat thejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofness onCourtfeestamppaperofRs.500/- including ponding test excetra. complete. First floor |
| 338 | Third floor |
| 339 | Fourth floor |
| 340 | Terrace floor |
| 341 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providingand laying12millimeterbeddingincementmortor1:3onverginconcreteslabwith waterproofing compound @ 1Kilogram/perbagofcementlayingbrickbatcobaof requiredthicknessincentimeter1:5 with waterproofing compound1Kilogram/bag ofcement grouting and finishing the top layer with 20millimeter thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48hoursbypondtestandcoveringtenyears\"guaranteeonrequisitestamppaperincludingcuringexcetra.complete. Ground floor |
| 342 | First floor |
| 343 | Second floor |
| 344 | Third floor |
| 345 | Fourth floor |
| 346 | Fifth floor |
| 347 | Sixth floor |
| 348 | Seventh floor |
| 349 | Eighth floor |
| 350 | Nineth floor |
| 351 | Tenth floor |
| 352 | Eleventh floor |
| 353 | Twelveth floor |
| 354 | Providingandapplyingwaterproofingtreatmentusingacrylicpolymermodifiedcement basedwater proofing coating with fibre glass mesh mixing at the rate of powder to liquid(2:1) by weight covering9to10SquareMetre/Kilogramwithtwocoatusingapproved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers excetra. complete. Basement Floor |
| 355 | Ground floor |
| 356 | First floor |
| 357 | Second floor |
| 358 | Third floor |
| 359 | Fourth floor |
| 360 | Fifth floor |
| 361 | Sixth floor |
| 362 | Seventh floor |
| 363 | Eighth floor |
| 364 | Nineth floor |
| 365 | Tenth floor |
| 366 | Eleventh floor |
| 367 | Twelveth floor |
| 368 | Terrace floor |
| 369 | Providingandfixing20to25millimeterthickroughshahabadboxtypewaterproofingforbasementor undergroundflooronabaseofCementconcrete1:3:6,includingsub baseof2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 millimeter depth, filling the joints with6 millimeter size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test excetra complete. (excluding Cement concrete 1:3:6 base concrete ) Ground floor |
| 370 | Providing and fixing 20 to 25 millimeter thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gapof 25 millimeter betweenrough shahabadand Reinforced Cement Concrete walls withcement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushingthejointshorizontallywithcementslurrymixed withwaterproofingliquidfor width 30 to 35 millimeter and sloping coping over topmost tile with cement mortar 1:3, butting the bottom mostwithCementconcrete 1:2:4mixedwithwaterproofing liquid,curing,with 7 yearsguaranteeoncourtfeestampofRs.100/-withponding testexcetracomplete.(excluding Cement concrete 1:3:6 base concrete) Ground floor |
| 371 | Providing and laying vitrified matt/antiskid fininsh tileshaving size 590 millimeter to 605 millimeter x to 605 millimeter of8to10millimeter thickness and confirming IS. 15622-2006 (Group Bla) of approved make,shade and pattern for flooring in required position laid on a bed of 1:4 cement morarincludingneatcementfloat,filling joints, curing and cleaning excetra. complete. Ground floor |
| 372 | First floor |
| 373 | Second floor |
| 374 | Third floor |
| 375 | Fourth floor |
| 376 | Fifth floor |
| 377 | Sixth floor |
| 378 | Seventh floor |
| 379 | Eighth floor |
| 380 | Nineth floor |
| 381 | Tenth floor |
| 382 | Eleventh floor |
| 383 | Twelveth floor |
| 384 | Providing and laying vitrified matt/antiskid finish tileshaving size 590 millimeter to 605 millimeter x to 605 millimeter of8to10millimeter thicknessandconfirmingIS.15622-2006(GroupBla)ofapprovedmake, shadeandpatternfordado andskirtinginrequiredpositionfixedin1:4cementmortar including neat cement float, filling joints,curing and cleaning excetra. complete Ground floor |
| 385 | First floor |
| 386 | Second floor |
| 387 | Third floor |
| 388 | Fourth floor |
| 389 | Fifth floor |
| 390 | Sixth floor |
| 391 | Seventh floor |
| 392 | Eighth floor |
| 393 | Nineth floor |
| 394 | Tenth floor |
| 395 | Eleventh floor |
| 396 | Twelveth floor |
| 397 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / OceanBrowngranite stone ofapprovedshade andsize 18 millimeter to 20millimeter thickon bed1:6cementmortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning excetra. complete. Basement Floor |
| 398 | Ground floor |
| 399 | First floor |
| 400 | Second floor |
| 401 | Third floor |
| 402 | Fourth floor |
| 403 | Fifth floor |
| 404 | Sixth floor |
| 405 | Seventh floor |
| 406 | Eighth floor |
| 407 | Nineth floor |
| 408 | Tenth floor |
| 409 | Eleventh floor |
| 410 | Twelveth floor |
| 411 | Providing and fixing machine cut machine polished 18 millimeter to 20millimeter thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade withfullmoulding and three grooved line forthetreadsonbedof1:4Cementmortar includingfloatfilling jointswithneatcement slurry curing polishing and cleaningexcetra. complete. Basement Floor |
| 412 | Ground floor |
| 413 | First floor |
| 414 | Second floor |
| 415 | Third floor |
| 416 | Fourth floor |
| 417 | Fifth floor |
| 418 | Sixth floor |
| 419 | Seventh floor |
| 420 | Eighth floor |
| 421 | Nineth floor |
| 422 | Tenth floor |
| 423 | Eleventh floor |
| 424 | Twelveth floor |
| 425 | Terrace floor |
| 426 | Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixingofstoneasperdrawing anddesign,includingcleaning,washingandfinishingexcetra. complete. Basement Floor |
| 427 | Ground floor |
| 428 | First floor |
| 429 | Second floor |
| 430 | Third floor |
| 431 | Fourth floor |
| 432 | Fifth floor |
| 433 | Sixth floor |
| 434 | Seventh floor |
| 435 | Eighth floor |
| 436 | Nineth floor |
| 437 | Tenth floor |
| 438 | Eleventh floor |
| 439 | Twelveth floor |
| 440 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / OceanBrown granite stone of 18 to 20 millimeter thick for door frame/ dado/ window boxing excetra. On Cement Mortar 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,excetra. complete. Basement Floor |
| 441 | Ground floor |
| 442 | First floor |
| 443 | Second floor |
| 444 | Third floor |
| 445 | Fourth floor |
| 446 | Fifth floor |
| 447 | Sixth floor |
| 448 | Seventh floor |
| 449 | Eighth floor |
| 450 | Nineth floor |
| 451 | Tenth floor |
| 452 | Eleventh floor |
| 453 | Twelveth floor |
| 454 | Providingand fixingmachinecutmirror polished 18 millimeterto 20 millimeter thicktelephoneblack granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges excetra.complete . Both side polish Ground floor |
| 455 | First floor |
| 456 | Second floor |
| 457 | Third floor |
| 458 | Fourth floor |
| 459 | Providing and laying machine cut machine Polished Kota stone flooring 25millimeter to 30millimeter thick andrequired widthinplain/diamondpatternonbed of1:6 CementMortar.including cementfloat, filling joints withneat cement slurry, curing, polishing and cleaningexcetra. complete. Basement Floor |
| 460 | Ground floor |
| 461 | First floor |
| 462 | Second floor |
| 463 | Third floor |
| 464 | Fourth floor |
| 465 | Providing andfixing in required positionskirting or dado of polishedKotahStone slab25 millimeter to 30millimeter thickfixed on base on plasterofcementmortar 1:4 including cementfloat, filling joints withcement slurry, curing rubbing, polishing and cleaning complete. Basement Floor |
| 466 | Ground floor |
| 467 | First floor |
| 468 | Second floor |
| 469 | Third floor |
| 470 | Fourth floor |
| 471 | Providing and laying matt finish ceramic tiles of having size 30 centimeter x 30 centimeter confirming to Indian Standard15622/2006 (groupDII-A)and7 millimeter to8 millimeter thickforflooring inrequiredpositionlaidonabedof1:4cementmortar including cement float, filling joint with white/colour cement slurry cleaning curing excetra. complete. Ground floor |
| 472 | Third floor |
| 473 | Fourth floor |
| 474 | Providing and laying ceramic tiles of having size 30 centimeter. x 30 centimeter. and confirming to corresponding Indian Standard for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing excetra. complete. Ground floor |
| 475 | Third floor |
| 476 | Fourth floor |
| 477 | Providing & Fixing in position, Carpetmore than 800+ gsm, made with100% stain proof fibres of approved make along with 5millimeter underlay as per Architectural & Acoustical Design & Instructions & Complete in all aspectsincluding all materials labour,finishing excetra complete Ground floor |
| 478 | Third floor |
| 479 | Fourth floor |
| 480 | ProvidingandfixingheavydutyinterlockingconcreteColouredpavingblocksof80millimeter thickness of having a strength of 300 Kilogram/Sq.cm. of approvedquality andshape ona bed of crushed sand of 25 to 30 millimeter thick including skirting joints and cleaning excetra.complete |
| 481 | Providing andconstructing granite kitchenplatform withfixing of stainlesssteelsink 600millimeter x 450millimeter sizeasperdetailed drawingincludingverticalboth sidepolished kadappahstone25to30millimeterthick supportswithkadappah top35to 40millimeter thickandpolishedgranite 16to 20millimeter topwithside stripsof granite at front and both sides of platform raised with two verticalgranitesupports15cmheightandtop graniteof75x40centimeterincludingcutting, opening for sink of required size in kadappah as well as granite excetra. complete. (Platform top size 5.00 meter x 0.60 meter and height is 0.75 meter) Ground floor |
| 482 | First floor |
| 483 | Second floor |
| 484 | Third floor |
| 485 | Fourth floor |
| 486 | Bamboowood14millimeter thick Tile Flooring including quarter round & door reducer - Providing &fixingin position Phenol bonded Epitome Bamboowood flooring with planks of sizes14millimeterthick,1800millimeter length (minimum) and 130millimeter wide (minimum), in approved colour, textureandfinish,having Performance Appraisal Certificate (PAC) issued by Buildingmaterials & Technology Promotion Council(BMTPC).Theflooringshallbefixedwith tongue and groove interlocaking system, with 2millimeter underlayassoundabrobingandmoisturebarrierandunderlaymentof4millimeter thickexpandedpolyethylene foam sheets having density 40Kilogram/cum, over preparedsurface withnecessary quarter round planks of size 1900millimeterx18millimeteranddorrreducerofsize1900millimeterx44millimeter,whereverrequired.TheEpitome Bamboowoodplanksshallhaveminimumdensityof1000Kilogram/cum&minimum Hardness1000 Kilogramf.withEcofriendlyUVcoating,allcompleteasperdirectionof Engineer in-charge Fourth floor |
| 487 | Bamboowood 14millimeter thick wall Skirting - Providing & fixing in position Phenol bondedEpitome Bamboowood in wall skirting with planks of sizes 14millimeter thick, 1900millimeter length(minimum) and 85millimeter wide (minimum), in approved colour, texture and finish, havingPerformance Appraisal Certificate (PAC) issued by Building materials & TechnologyPromotion Council (BMTPC). The skirtingshallbefixedSSscrews&rawlplugs,over underlayment of 4millimeter thick expanded poly ethylene foam sheets having density 40Kilogram/cum,overpreparedsurface.TheEpitome Bamboowood planks shall haveminimum density 1000 Kilogram/cum & minimum Hardness 1000 Kilogramf.withEco friendly UV coating, all complete as per direction of Engineer in-charge Fourth floor |
| 488 | Providingandfixing30millimeterthick SOLIDPANELPoly vinyl ChlorideINTERNALDOORSHUTTER consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40millimeter x 20millimeter for stiles ,top, lock and bottom rails. M.S. frame shall have a coat of steel primers of approved makeandmanufacture.M.S.frameshallbe coveredwith5millimeterthickheatmolded Poly vinyl Chloride channel of size 30 x 100millimeter forming stiles, and 5millimeter thick, 125millimeter wide Poly vinyl Chloride sheets for top rail, lock rail and bottom rail on either side, and15millimeter (5millimeter x 3) thick, 20millimeter wide cross Poly vinyl Chloride sheet as gap insert for top rail and bottom rail. Paneling of 10 millimeter thick prelam Poly vinyl Chloride sheet to be fitted in the M.S. frame welded / sealed to the stiles and rails with 30millimeter wide x 5millimeterthickPoly vinyl Chloride sheetbeadingoneitherside,andjoinedtogetherwithsolventcement adhesive excetra. An additional 5millimeter thick Poly vinyl Chloride strip of 20millimeterwidth is to be stuck on the interior side of the C Channel using Poly vinyl Chloride solvent cement adhesive. includingstainlesssteelfixturesand fasteningCompleteasper direction of Engineerincharge,manufacturer\"sspecification and drawing. Ground floor |
| 489 | First floor |
| 490 | Second floor |
| 491 | Third floor |
| 492 | Fourth floor |
| 493 | Fifth floor |
| 494 | Sixth floor |
| 495 | Seventh floor |
| 496 | Eighth floor |
| 497 | Nineth floor |
| 498 | Tenth floor |
| 499 | Eleveth floor |
| 500 | Twelevth floor |
| 501 | Solid Core Flush door Single leaf Providingandfixingfactorymadesolid coreflushdoorinsingleleaf35millimeterthick,decorativetypes,of exterior grade, as per detailed drawings, conforming to Indian Standard :2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessarybeads,mouldingandlipping,holdfasts,matfinishstainlesssteelfixturesfastenings,finishing withfrench-polish/waxingcomplete.(withoutdoorframe).(SampletobegotapprovedfromEx.Engineer before use) Comillimeterercial Hard Wood shutter Basement floor |
| 502 | Ground floor |
| 503 | First floor |
| 504 | Second floor |
| 505 | Third floor |
| 506 | Fourth floor |
| 507 | Solid Core Flush door Double leaf Providing and fixing factory made solid core flush door shutters in double leaves 35millimeter thick,decorative type ofexterior grade,as perdetaileddrawings,conforming to Indian Standard.: 2202– 1966(Revised) including approved face veneersonbothsides,withoutglazing andvenetiansincluding matfinishstainlesssteel fixturesand fastening, stoppers and finishing with french polishing excetra. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Comillimeterercial Hard Wood shutter Ground floor |
| 508 | First floor |
| 509 | Second floor |
| 510 | Third floor |
| 511 | Fourth floor |
| 512 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300millimeter x 40millimeterx 5millimeter with oil painting,Basement floor |
| 513 | Ground floor |
| 514 | First floor |
| 515 | Second floor |
| 516 | Third floor |
| 517 | Fourth floor |
| 518 | Providing and applying melamine polish of required finish to the wood work by spraymachine includingknottingandpreparingtheevensurfacebyscraping,applyingFrench polish , scaffolding if required excetra. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. Basement floor |
| 519 | Ground floor |
| 520 | First floor |
| 521 | Second floor |
| 522 | Third floor |
| 523 | Fourth floor |
| 524 | Providing of120 min Fire rated lead lined doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 with standard heating conditions as specified inIS:3614PartII1992andBS:476part20&221987toachievetherequiredintegrity,insulationand stability (i.e. to restrict the heat radiation, temperature rise on the nonfire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested withNCBN technology(\"NonCombustiblebyNature\").Leadlinedtocheckradiation.CodeNo;2HourInsulated, Flame, Smoke Radiation check Lead Lined Fire Door 57millimeter 2HR FRL (120/120) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. a) Door Frame: Providing Frames for Lead Lined Fire resistant door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 140 X 70 millimeter with45millimeter thick two layered 3millimeter LeadLine Sheets with10millimeter overlapfrom either side & spray quoted with2coatsofIntumescentpaintofminimum200micron,with1rowofBrush-TypeAstroflame® intumescent strip (imported) of size 10millimeterx4millimeter concealed in the groove of the Frame for fire and hot and cold smoke sealing, excetra. complete as per direction of Engineer in Charge Ground floor |
| 525 | First floor |
| 526 | Second floor |
| 527 | Third floor |
| 528 | Fourth floor |
| 529 | Fifth floor |
| 530 | Sixth floor |
| 531 | Seventh floor |
| 532 | Eighth floor |
| 533 | Nineth floor |
| 534 | Tenth floor |
| 535 | Eleveth floor |
| 536 | Twelevth floor |
| 537 | Terrace floor |
| 538 | b) Shutter: Providing of 57millimeter thick asbestos free composite, \"TUFWUD\" brand - 3 criteria - fire, heat and smoke check Lead Lined Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9millimeter CalciumSilicateboards,Chemical treated internal timberwith Fireretardant chemicalsin pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x30 millimeter with30millimeter thick infill of ceramic fibre (density 128 Kilograms/CMT) vermiculite mix, 3millimeter thick Lead Sheet on one side faced & 3millimeter Fire retardant High Density Fibreboard, internallylippedwithhardwoodbeading,andpastedinHydraulicPressunder50tonnespressure,spray quotedwith2coatsofIntumescentpaintofminimum300micron,andwith1rowofBrush-Type Astroflame®intumescentstrip(imported)ofsize 10millimeterx4millimeter concealedforfire andsmoke sealing inthe grooves in the shutter on all edges except bottom, without any external lipping. Ground floor |
| 539 | First floor |
| 540 | Second floor |
| 541 | Third floor |
| 542 | Fourth floor |
| 543 | Fifth floor |
| 544 | Sixth floor |
| 545 | Seventh floor |
| 546 | Eighth floor |
| 547 | Nineth floor |
| 548 | Tenth floor |
| 549 | Eleveth floor |
| 550 | Twelevth floor |
| 551 | Terrace floor |
| 552 | c) Vision Panel: 2 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside the shutter structure with 10 millimeter inside the shutter on all sides with U- glazing. An additional insulated powdercoated \"Z\" channel of 16 swg MS sheet to be fixed for reinforcement of the joints. Ground floor |
| 553 | First floor |
| 554 | Second floor |
| 555 | Third floor |
| 556 | Fourth floor |
| 557 | Fifth floor |
| 558 | Sixth floor |
| 559 | Seventh floor |
| 560 | Eighth floor |
| 561 | Nineth floor |
| 562 | Tenth floor |
| 563 | Eleveth floor |
| 564 | Twelevth floor |
| 565 | Terrace floor |
| 566 | Panic Bar: (For 2 Hr fire Rated single Panic bar)Supplying, fitting & fixing Surface mounted Crash Bar/ panic Bar of touch pad style ,made of heavy duty cast iron/ steel body & latches with SS ,BHMA certified & conforming to ANSI A 156.3 for grade-1 ( 3 hours fire rated ) and suitable for surface mounting to wooden/hollow metal/ Al framed door,with maximum operating force 8Kilogram for unlocking easily & outwardly during emergency,complete in all respect as per direction & satisfaction of Engineer-in charge including all taxes & incidental charges. (Note: To be installed at \"FIRE EXIT\"only under location specific instruction of Eingineer-in -Charge.) Ground floor |
| 567 | First floor |
| 568 | Second floor |
| 569 | Third floor |
| 570 | Fourth floor |
| 571 | Fifth floor |
| 572 | Sixth floor |
| 573 | Seventh floor |
| 574 | Eighth floor |
| 575 | Nineth floor |
| 576 | Tenth floor |
| 577 | Eleveth floor |
| 578 | Twelevth floor |
| 579 | Terrace floor |
| 580 | Providing andfixing in position powder coated aluminium louvered windows / ventilator of varioussizes withpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38 millimeterx1.22millimeter boxtype,5millimeterthicksheetglasslouvers,of approved quality excetra. complete. Ground floor |
| 581 | First floor |
| 582 | Second floor |
| 583 | Third floor |
| 584 | Fourth floor |
| 585 | Fifth floor |
| 586 | Sixth floor |
| 587 | Seventh floor |
| 588 | Eighth floor |
| 589 | Nineth floor |
| 590 | Tenth floor |
| 591 | Eleveth floor |
| 592 | Twelevth floor |
| 593 | Kitchen Trolley ProvidingandFixingstainlesssteelkitchentrolleyofoverall26\"heightand22\"depth,supportedon aluminium pipes ,trolley basket made out of 5 millimeter stainless steel rod fitted on telescopic channel of size 1.5 \" x 20 \" x 22 \" on both sides of trolley of 12 \" or above size, panel having 40Kilogramload bearing capacity of trolley made out of 20 millimeter PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by whitemica ,100millimeters.s. decorativehandle.(Thewidth and heightof individual compartments shall be kept as directed by Engineer-in-charge) Ground floor |
| 594 | First floor |
| 595 | Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600millimeter Lay in tiles of pre coated galvanized steel in 0.5 millimeter thickness in Global white color tile to be laid ongrid systems with 15millimeter wide T - sectionflangescolorwhitehavingrotarystitchingontheMainRunner,1200millimeter and 600 millimeterCross Tees.Providing andFixing of GI Lay in Plainmetal ceilingconsistingof600x600millimeter Layintilesofpre coated galvanized steel in 0.5millimeter thicknessinGlobalwhite colortile to be laid ongrid systemswith 15millimeter wide T - section flanges color white having rotary stitching on the Main Runner, 1200 millimeter and 600millimeter Cross Tees.products approved as per GRIHA and BS 476 excetra. complete. Ground floor |
| 596 | First floor |
| 597 | Second floor |
| 598 | Third floor |
| 599 | Fourth floor |
| 600 | Fifth floor |
| 601 | Sixth floor |
| 602 | Seventh floor |
| 603 | Eighth floor |
| 604 | Nineth floor |
| 605 | Tenth floor |
| 606 | Eleveth floor |
| 607 | Twelevth floor |
| 608 | Providing and fixing Modular false ceiling of 600 x 600 millimetercenter to center and 13 millimeter thick square mineral fiberboardtobefixedonframeworkofalluminiumsectionsforsuspendedfalse ceiling consisting of alluminiumT2?x1½?(50 millimeterx40 millimeter)weighing0.39 Kilogram/m at 60 cms center center and fixed with ½? x ½? (15 x 15millimeter) flanges weighing0.19 Kilogram/m suspended on 6 millimeter dia mild steel rod weighing 0.22 Kilogram/m, fixed on wall and beams including rounding of the edges with alluinium T of 2? x 1 ½? (50 millimeterx 40millimeter) weighing 0.39 Kilogram/m excetra. (all alluminium sections shall be anodized) including all labour, material, lifts excetra. complete. First floor |
| 609 | Second floor |
| 610 | Third floor |
| 611 | ACOUSTICAL GLASS FIBREFALSE CEILING BLADES : Providing and Fixing Acoustical blade which are 40 millimeter thick, flat glass fibre panelswith Humidity Resistance RH 90%, with factory fitted embedded metal insert with ¼” – 20 threading for fixing cable adjuster for hanging application. Acoustical blades shall have sizes of 200x1200 millimeter, 200x1600 millimeter, 400x1200millimeter, 400x1600millimeter 400x1800millimeter 500x1200millimeter or 500x1600millimeterwith both side laminated scrim finished with uniform water based paint on all surface (including edges). Acoustical performance of 0.65 NRC(for 400millimeter high x 40millimeterthick baffles with 400millimeter on centre distance and overall depth of construction 1000millimeter) as per ASTM C-423 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) in standard White color with Light reflectance 87% or in the color specified by the Architect (Shell / Tangerine / Cranberry / Moss / Kiwi / Reef / Lagoon), Fire Performance Class B2 – s1, d0 as per EN 13501-1 .The blade shall be made of Glass fibre panel with density of 110-120 kilogram/ m3. SUSPENSION: The panel shall be hung using hanging kit comprising of griper structure anchor & cap of dia 20millimeter, spring loaded bottom end cable adjuster of dia. 9millimeter and 2.4m long aircraft cable of1/16” dia.The Blade along with suspension system shall carry a 1 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The supply shall be backed by a Manufacturing Test Certificate. Suspension System DetailsComponents1) Griper structureanchor 2) Gripper anchor cap 3) Cable adjuster 4) Aircraft Cable Cable adjuster Spring loaded bottom end cable adjuster of dia. 9millimeter and 45millimeter long Aircraft cable Material Galvanized Steel Aircraft cable dimension 1/16”Ø x 2.4meter Tolerance ±1millimeter. INSTALLATION: Hanger Wire Attachment to Structure: Attach the gripper structure anchor to the structure with an appropriate fastener (1/4\"-20 Threading) that will carry the full weight of the blades. Insert the end of the cable into the gripper anchor cap. Screw the gripper anchor cap completely into the gripper structure anchor. Insert Suspension Cables:The panel is to be suspended using the aircraft cables which are suspended from the soffit using the gripper structure anchors and its other end passing through the bottom end cable adjuster. The height & level of the panels can be adjusted using the bottom end cable adjusters.Suspension of Blade: Locate the two factory fitted female inserts on the blades. Suspend the Blades by screwing the bottom end of the cable adjuster into the female inserts. Installation should be carried out as per Manufacturer recomillimeterended procedure.Ground floor |
| 612 | Providing and fixing in position Gypsum board false ceilingwith 12.5 millimeter thick Gypsum boards, screwed/fixedtotheunderstructureofsuspendedG.I.Gridconstructedand suspended from the main ceilingconsistingofceilingsectionsofsize25x50millimetermaximumcenter to center distance of 600 milimetre perimeter channel and intermediate channels atmaximum center to center distance 1200 milimetregalvanizedgridshouldbefixedto reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediatechannels. Additionalintermediatechannelsshouldbefixedtostraphangersforadditional support to prevent strapping at every 1200 milimetre item to be completed inall respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts excetra. all complete. Ground floor |
| 613 | First floor |
| 614 | Second floor |
| 615 | Third floor |
| 616 | Fourth floor |
| 617 | Fifth floor |
| 618 | Sixth floor |
| 619 | Seventh floor |
| 620 | Eighth floor |
| 621 | Nineth floor |
| 622 | Tenth floor |
| 623 | Eleveth floor |
| 624 | Twelevth floor |
| 625 | Double Faced Mobile Unit for Compactor 2150millimeterH x 2745millimeterW x 900millimeterD Providing and fixing Double Faced Mobile Unit for Compactor 2150millimeterH x 2745millimeterW x 900millimeterD- BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 millimeter thick MS Sheet Size of Channel25millimeter x 100millimeter x 45millimeter. GUIDE RAILS : The guide rails shall be made out of 28millimeter Bright bar placed on 1.2 millimeter thick M.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition excetra. Will act asanintegralmemberoftheUnit.SHELVES:Shelvesmadeof22SWGthickPrimeQualityC.R.C.A. having10 foldseachwillbeprovided eachdesignedtocarryaU.D.L.of70Kilograms.VERTICAL PANEL: Verticalpanelconsistsofthefront,Centre&rearpanelshallbemadeoutof20SWGthick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made outof22SWGthickC.R.C.A.primequalitySteeltocovertheentiredrivemechanism.CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : Systemwillbeprovidedwithindividualracklockingaswellascentralisedlocking arrangement on the last unit when all units are brought together,central lock when operated gets locked with thefloor&doesnotallowaccesstotheunits.DRIVEMECHANISM : DrivingMechanism willbe provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000millimeter x 200millimeter x 60millimeter.DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT :Acrylic cardholdersprovidedonthefrontpanelfor easyidentification&retrieval.FINALFINISH: Powder Coating (8 tanks process with 70 microns). First floor |
| 626 | Single Faced Mobile Unit for Compactor 2150millimeterH x 2745millimeterW x 457millimeterD Providing and fixing Single Faced Mobile Unit for Compactor 2150millimeterH x 2745millimeterW x 457millimeterD- BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 millimeter thick MS Sheet Size of Channel25millimeter x 100millimeter x 45millimeter.GUIDE RAILS : The guide rails shall be made out of 28millimeter Bright bar placed on 1.2 millimeter thick M.S. Plate which will be above the floor and are as per the international standard of safety.SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition excetra. Will act asanintegralmemberoftheUnit.SHELVES:Shelvesmadeof22SWGthickC.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made outof22SWGthickC.R.C.A.primequalitySteeltocovertheentiredrivemechanism.CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : Systemwillbeprovidedwithindividualracklockingaswellascentralisedlocking arrangement on the last unit when all units are brought together,central lock when operated gets locked with thefloor&doesnotallowaccesstotheunits.DRIVEMECHANISM : DrivingMechanism willbe provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000millimeter x 200millimeter x 60millimeter.DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENTPrimeQualityC.R.C.A. having10 foldseachwillbeprovided eachdesignedtocarryaU.D.L.of70Kilograms.VERTICAL PANEL: Verticalpanelconsistsofthefront,Centre&rearpanelshallbemadeoutof20SWGthick :Acrylic cardholdersprovidedonthefrontpanelfor easyidentification&retrieval.FINALFINISH: Powder Coating (8 tanks process with 70 microns). First floor |
| 627 | Single Faced Mobile Unit for Compactor 2150millimeterH x 1830millimeterW x 457millimeterD Providing and fixing Single Faced Mobile Unit for Compactor 2150millimeterH x 1830millimeterW x 457millimeterD- BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 millimeter thick MS Sheet Size of Channel25millimeter x 100millimeter x 45millimeter.GUIDE RAILS : The guide rails shall be made out of 28millimeter Bright bar placed on 1.2 millimeter thick M.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition excetra. Will act asanintegralmemberoftheUnit.SHELVES:Shelvesmadeof22SWGthickPrimeQualityC.R.C.A. having10 foldseachwillbeprovided eachdesignedtocarryaU.D.L.of70Kilograms.VERTICAL PANEL: Verticalpanelconsistsofthefront,Centre&rearpanelshallbemadeoutof20SWGthick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made outof22SWGthickC.R.C.A.primequalitySteeltocovertheentiredrivemechanism.CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : Systemwillbeprovidedwithindividualracklockingaswellascentralisedlocking arrangement on the last unit when all units are brought together,central lock when operated gets locked with thefloor&doesnotallowaccesstotheunits.DRIVEMECHANISM : DrivingMechanism willbe provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000millimeter x 200millimeter x 60millimeter.DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT :Acrylic cardholdersprovidedonthefrontpanelfor easyidentification&retrieval.FINALFINISH: Powder Coating (8 tanks process with 70 microns). First floor |
| 628 | Second Floor |
| 629 | Third floor |
| 630 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, teesexcetra.asper detaileddesignanddrawingsorasdirectedincludingcutting,fabricating, hoisting,erecting,fixingin positionmakingriveted/bolted/weldedconnectionswithout connecting plates, braces excetra. andincluding onecoatofanticorrosivepaintand overit twocoatsofoilpaintingofapprovedqualityandshadeexcetra.complete. Ground floor |
| 631 | Providing structural steel work of rectangular hollow steel section for steel trusses, othersimilar trusseditemslikepurlinandmemberswithallbracing,gussetplatesexcetra.asper detailed designs and drawingsorasdirectedincludingcutting,fabricating,hoisting,erecting,fixingin positionmaking riveted/bolted/ welded connections and one coat of anticorrosivepaintandoverittwocoatsofoil painting of approved quality and shade complete. Ground floor |
| 632 | Providingstructuralsteelworkinhollowsectionofvariousthicknessandsizesinsquare, rectanular and round shape from 25millimeter to 450millimetersection as per Indian StandardS4923 YST 310 Grade produced from iron ore and blast furnace route excetra. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. Second floor |
| 633 | Third floor |
| 634 | Providingandfixing900millimeter highS.S.304Grade Stainlesssteelrailingwith40millimeter diameterand 1.5millimeter thickattop,40millimeter diameterand 1.5millimeter thickverticalsupportsspaced at 1.5meter center tocenter and 8millimeter thick toughened glass including fabricating ,fixtures, errecting ,necessarywelding,grinding,finishing, buffing to stainless steel pipe excetra. complete First floor |
| 635 | Second floor |
| 636 | Third floor |
| 637 | Fourth floor |
| 638 | Providing and fixing mild steel grill work for windows, ventilators, excetra. 15 Kilogram/Square Metreasper drawingincludingfixturesnecessaryweldingandpaintingwithonecoatof anticorrosive paint and two coats of oil painting complete. Ground floor |
| 639 | First floor |
| 640 | Second floor |
| 641 | Third floor |
| 642 | Fourth floor |
| 643 | Fifth floor |
| 644 | Sixth Floor |
| 645 | Seventh floor |
| 646 | Eighth floor |
| 647 | Nineth floor |
| 648 | Tenth floor |
| 649 | Eleveth floor |
| 650 | Twelevth floor |
| 651 | ProvidingandlayinginsitucementconcreteM20withtremixtreatmentfor100millimeter thicknessfor flooringwithgroovecuttingof4millimeterwideand20millimeterdeepwithnecessary refilling with bitumenexcetra. complete. Basement floor |
| 652 | Ground floor |
| 653 | Providing & Fixing in positionAcoustical Doors along with150 x 150millimeter teak woodframe, doors made from 50millimeter Teak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50millimeter thick and 3millimeter Tecsound from both sides, 12millimeter waterproof ply & veneer from both sides , including 150millimeter heavy duty SS hinges(Geze/Dormaoreq.) 4noeachleaf, withDoor-closer(Dorma/Gezeoreq.) includingcostof required Cut-Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural&AcousticalDesign&Instructions&Completeinallaspects.includingallmaterials labour,finishing excetra complete Ground floor |
| 654 | Providing and FixingSoft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles of size 15millimeter Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ?85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15millimeter , suitable for Green Building application, with Recycled content of 66% GW and 74% RW. The tile shall be laid on precoated G.I channel 32 with 15 millimeter wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 millimeter and 600 millimeter Cross Tees with a web height of 32 millimeter and a load carrying capacity of 7 Kilograms/M2 with a minimum pull out strength of 100 Kilograms. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system The Tile and Grid system used together should carry a 10 year warranty.products approved as per GRIHA and BS 476 excetra. complete. Ground floor |
| 655 | ACOUSTICAL WALL PANELLING – FABRIC WRAPPED OF SIZE: 600X600/1200X25millimeter Providing and Fixing of Acoustical Wall Panel with square edges made of fibre glass substrate 25millimeter thick, wrapped on the front side with an acoustically transparent fabric as per the approved shade (Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut and Shell). The panel shall be classified for Fire ClassA,asperASTME-84.TheAcousticalWallPanelshallbeofsizes600x600millimeter(Nominal)or 600x1200millimeter(Nominal)andshallachieveanNRCof0.85(AveragevalueofAbsorptionCo-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) with 50millimeter airgap as per ASTM C423 to be fixed to wall on a framework of wooden battens and using Wall panel Impalers (supplied by the manufacturer) or byusingconstructionadhesives(aspertheinstructionslaiddownbythemanufacturer).Thefibreglass substrate shall have a recycle content of 85%.Installation:An appropriate vapour barrier (by others) shall be applied/installed on the vertical surface before the installation to properly seal against entry of any moisture. Vapour barrier (by others) shall be installed as per Manufacturer‘s recomillimeterendation. Install wooden batten grid (provided by others) of section 50x50millimeter or as approved by the Architect on the solid wall/partition to provide level and plumb surface. The Impalers shall befixedtothebattensusingself-tappingscrews,3nos.incaseof600x600millimeterand4nos.incaseof 600x1200millimeter.Silicabasedconstructionadhesive(byothers)tobedabbedontotheprojectingelements (spikes) of the Impalers. Wall Panels shall be pierced through the spikes of the Impalers ensuring the line and level of the panels are maintained Ground floor |
| 656 | First floor |
| 657 | Providing & fixing in position, heavy duty fully upholstered Auditorium chairs 520 millimeter c to c tip-up type. Height of back should be less than 1030 millimeter with plastic protective cover on back and bottom having teak wood handles. Back to back distance is 1000millimeter. The auditorium chairs should be of following specifications 1. Powder Coated Heavy duty MS Stand.2. Individually moulded , ergonomically designedseat and back cushions. 3.Moulded Polyurethane Foam cushion. PU foamdensity 48– 52 Kilograms/cu.mtr4. Moulded Polyurethane Foam manufactured in certified ISO 9001 facilityto ensure consistency in density for longevity .5.Upholstered in Foam laminated strexcetrah sandwich Fabric for clean finish and soft comfortable feel as per the colour & pattern selected by the client. 6.Seat and Back should have moulded synthetic protective cover. 7. Wooden or PU armrest65millimeter x 20millimeter- 330millimeterlong . 8.Mounted using Anchor fasteners. Ground floor |
| 658 | Providing & fixing in position Stage flooring Made from 18millimeter plywood 1200 x 2400 & 18millimeter Teakwood planks 100 x 800 having tongue & grove on Sal-wood frame of 50 x 100 at 600millimeter c to c on stage surface including cost of required Cut-Outs, decorative mouldings / finishing-items / polish excetra., as per Architectural & Acoustical Design & Instructions & Complete in all aspects..including all materials labour,finishing excetra complete Ground floor |
| 659 | Providing,laying,spreadingandcompactingstoneaggregatesofspecificsizestowaterboundmacadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying andbroomingrequisitetypeofscreening/bindingMaterialstofilluptheintersticesofcoarseaggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) millimeter Aggregate) |
| 660 | Providing,laying,spreadingandcompactingstoneaggregatesofspecificsizestowaterboundmacadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying andbroomingrequisitetypeofscreening/bindingMaterialstofilluptheintersticesofcoarseaggregate, watering andcompacting withvibratory roller to the requireddensity. By Mechanical Means- Grading II (Using Screening Type B (11.2 millimeter) Aggregate) |
| 661 | Providing and constructing 75 millimeter. thick ModifiedPenetration Macadam (MPM) road surface including all materials,preparingtheexistingroadsurface,spreading40millimeter.stonemetallayers100%crusherbroken metal with conical crusher plant heating and spraying thebitumen of specified grade @ 2 kilogram/sqm, spreading 12 millimeter.size chips compacting with three wheel static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 excetra. complete.Including picking of existing WBM surface. (VG-30 bulk bitumen rates are considered to arrive at rates) |
| 662 | Providing bituminous Type A liquidseal coat on bituminous surface including supplying all materialsand bitumen of specified gradepreparing existing road surface, heating and applying bitumen @ 0.98 kilogramSqm. by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 Metric Tonne. excetra. complete. (VG- 30 bulk bitumen rates are considered to arrive at rates) |
| 663 | Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on B.T. surface 2.5 kilogram/10 sqm.(VG-30 bulk bitumen rates are considered to arrive at rates) |
| 664 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 millimeter with lock plate of 3.15 millimeter thickness reinforced with 35 x 35 x 5 millimeter angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 millimeter and 3.15 millimeter respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 millimeter minimum size and shape with square bar, suspension shaft of minimum 32 millimeter diameter, hood cover of M.S. sheet not less than 0.9 millimeter thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer excetra. complete. (Indian Standard 62481979) (With mechanical gear) Ground floor |
| 665 | Providing,aupplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 millimeter thick ACP sheet material consisting of 3millimeter thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 millimeter thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated withkynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws,nuts,bolts,washers, cleats,weather silicon sealent,backer rods excetra .overall weight of the ACP shall not be less than 7.5 Kilogram/Square Metre) Ground floor |
| 666 | Providing and casting in situ or precast tapering Reinforced Cement Concrete M-20 Barrier type Kerb with gutter ( as per IRC 86 1983) embedded 125millimeter below ground level over M-10 PCC finished neatly with Cement Mortar 1:2, setting the same in Cement Mortar 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant |
| 667 | Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds excetra. as may be necessary for foundation and other parts of the the works and pumping out water during andafterexcavationasmayberequiredbyusing3.0BHPpumpexcetra.complete.(priorapprovalofSuperintending Engineer will be necessary) |
| 668 | SupplyandInstallationoftranslucentroofwithDPIFluxstandingseammulticellpolycarbonatepanel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a completesystem.Co-extrudedUVprotectedpolycarbonatepanelsystem ofmin12millimeter thickof900millimeter (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfyDartdropimpacttestasperIS14443-97shallshownosignofbreakageonPolycarbonatesheets whichhavebeenexposedtoUVforamin.of500HoursasperASTMG155.Panelsshallnothave Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MSstructuralsteel/MSpurlin(paidseparately)conformingtothedetailtechnicalspecificationsasper approvedarchitecturaldrawings.Trainedandfactoryauthorizedlabourwithsupervisiontocompletethe entire panel installation as per drawing & directionof the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12millimeter thick panels shall be used for a roofing height of upto 15 mtrs. Third floor |
| 669 | Fourth floor |
| 670 | Terrace floor |
| 671 | Providing and fixing 45 cm wide mild steel ladder of 40millimeter x 6 millimeter mild steel flat stringers andstepsof18 millimeterdia. mild steel bar for water tank including fixing it in (1:2:4) M-15cement concrete block 60cmx30cmx30cmandpaintingtheladdercomplete.(Anti Corossive Paint) Third floor |
| 672 | Fourth floor |
| 673 | Terrace floor |
| 674 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gusset platesexcetra.asperdetaileddesignsanddrawingsorasdirectedincluding cutting,fabricating,hoisting, erecting fixing in position, Making riveted/ bolted/ weldedconnection and onecoatofanticorrosive paint andover it 2 coats of oil painting approved quality and shade excetra. complete. Third floor |
| 675 | Fourth floor |
| 676 | Terrace floor |
| 677 | METALFALSECEILINGWITHOUTSUSPENSIONSUPPORTFROMTRUECEILING:Providing&fixinghorizontallevel suspended metal ceilings comprising of Metalworks F-H 600 Hook-on corridor system manufactured by Armstrong Ceiling Solutions withRectangularpanelsmadeof0.7millimeterthickGalvanisedSteel(GI)of120gsm,postcoatedtoGlobal Whitecolour,suitablefor Interior applications and architectural finishes, double grid concealed system and butt joint panels. The panel width shall be 300millimeter, length ranging from 1500millimeter to 2660millimeter. General Specifications:Entire system to be designed for Interior applications, and concealed Grid, Butt joint panels. Panel Specifications: Material: The F-H 600 rectangular Hook-on panels to be made of galvanized steel (GI) of minimum 120gsm hot dipped galvanization (both sides included) as per IS 277 (2003), zero or minimum spangled, in minimum base material thickness of 0.7millimeter as per in IS:513 (1994). Dimensions: The panel Length varies between 1500millimeter to 2660millimeter, panel Width shallbe300millimeter.Thedimensionaltolerancesforlengthshallbe±1.0mupto1000millimeterL;±1.5millimeterbetween1001to2000millimeterL;±2.0millimeter between 2001 to 3000millimeter L. The dimensional tolerances for width shall be ±0.5m up to 300millimeter W. Dimensional Tolerances for panel Thickness / panel width / panel length - to be measured in accordance with TAIM standards. Edge detail: the panels shall ha+A3ve Square Edge, with a 3millimeter(W) x 8millimeter(H) black foam gasket glued at the edges, typically on one long and one short side. All adjacent panels shall touch each other forming a butt joint and concealed grid visuals. Upturns: The short side of the panel shall have vertical upturnsof minimum30millimeter(H)and shall be bent appropriately bent as perthe manufacturer‘sspecifications forproviding hook-on ends. The long side shall have inside horizontal bends of 5-15millimeter for rigidity and vertical upturns of 40millimeter (for length ranging from1251-2660millimeter).Surface Finish: Plain: Thepanels shall be inplain unperforatedfinish (withoutany acoustical backing / felt). Colour and finishes: The panel surface shall be electrostatically powder coated (post coat) on visible side after mechanical production, using RoHS compliant powder, to achieve coating thickness ranging from 60-80µ and architectural quality finish. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017, 250 hours of condensation test (as per DIN 50017 or DIN EN ISO 6270-1 Norms), UV resistance of 500 hours and 50% gloss retention (as per ASTM G 154 UVB-313 Norms). The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E (?e) <1 measured using Excite/BYK Gardner instrument and gloss level of 25±5% at 60° as per ASTM D523.The colour / shade to be Global White (Polyester for Interior) as approved by the Architect or Engineer-in-charge. Surface Protection: The visible panel surface shall be protected using a guard film made of LDPE of 50µthickness,having appropriatesurface adhesion(or tackiness)corresponding to surface glosslevel. Light reflectance: Thepanel shall have a Light Reflectance of = 63% in accordance to ASTM 1477-98. Flatness and Sag limit: Panels shall be flattened by precision leveller to minimize sag to less than Length/400millimeter. The difference between the two diagonal dimensions of the panel to be less than 1millimeter. The sag to be measured at the center in accordance with TAIM standards. Access and Plenumspace: The panels to be Fully Accessible, with system height of 98millimeter, and would require a plenum height of a minimum450millimeter clear space frombare ceiling / rigid structure for installation. Packaging: The Panels shall be packed in wooden crates of appropriate dimensions based on panel sizes. The wooden planks for rates shall have thickness of approx.15millimeter, width of around 4? and gap between two planks around 3?. Crates to have layer separators of 1? x 2? dimensions to prohibit load transfer on bottom panels, and the crates lifting to be 2way or 4way. The bottom of crates shall be completely closed, and the panels kept inside shall have cushioning of corrugated sheets or other appropriate material. Installation Specifications: Primary and secondary runners Installation: U-Profiles, spaced at 1200millimeter, to be suspended from ceiling using clamping brackets and threaded rods OR hanger wires. Hanger wires must be wrapped tightly with 3 full wraps. The J-Bars(directional)shall intersect theU-profile at 90° at every moduledictated by the panel length. TheJ-Bar isconnected to the U- Ground floor |
| 678 | First floor |
| 679 | Second floor |
| 680 | Third floor |
| 681 | Fourth floor |
| 682 | Providing andfixing Indian teak woodplankceiling 20millimeter thickplainundersidetonguedand grooved including ironscrews,scaffolding,ifnecessary,including oneprimercoaton under side and one coat ofcoal tar on upper side excetra. complete. Third floor |
| 683 | Fourth floor |
| 684 | Providing earth work in embankment with approved materials obtained from departmental land upto lead of 50m. including all lifts, laying in layers of 20centimeter. to 30centimeter. thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller to achieve not less than 97 % of standard proctor density excetra. complete ( Material obtained from departmental Land) |
| 685 | Providing and laying cement concrete pipe of Indian Standards 458:2003 NP-2 class of 600millimeter diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing excetra. complete. |
| 686 | Providing and laying cement concrete pipe ofIndian Standards 458:2003 NP-2 class of 900millimeter diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing excetra. complete. |
| 687 | Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, excetra complete. Ground floor |
| 688 | First floor |
| 689 | Second floor |
| 690 | Third floor |
| 691 | Fourth floor |
| 692 | Fifth floor |
| 693 | Sixth Floor |
| 694 | Seventh floor |
| 695 | Eighth floor |
| 696 | Nineth floor |
| 697 | Tenth floor |
| 698 | Eleveth floor |
| 699 | Twelevth floor |
| 700 | Terrace floor |
| 701 | Providing and fixing mild steel grill railing weighing 15Kilogram/One Square Metre. with Poly vinyl Chloride handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing Poly vinyl Chloride handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, excetra. complete. Spec. One Number : As directed by Engineer in charge. Ground Floor |
| 702 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader/ Paver on prepared surface, mixing by mix in place method with rotavator at Optimum Moisture Content, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- By Mix in Place Method and Grading - III Material |
| 703 | BITUMINOUS MACADAM:--Providing and laying bituminous macadam using crushed aggregate of Grading 1, premixed with bituminous binder, transported at site with VTS, laid over a previously prepared surface , finished to the required grade ,level, alignment,and rolling to achieve the desired density for 80/100 millimeter compacted thickness with drum mix type hot mix plant with SCADA having complying essential features of Hot mix plant as per IRC-27 2009 specified conditions and attachments such as electronic load sensor based belt conveyers,automatic synchronization of bitumen and aggregate fedder,built in dust controller system and PLC for Drum Mix plant ,Sensor paver,and Vibratory roller excluding prime/Tack coat excetra. complete --Bitumen3.30% of specified grade (VG-30 bulk bitumen rates are considered to arrive at rates) |
| 704 | BITUMINOUS CONCRETE:--Providing and laying bituminous concrete using crushed aggregate of grading 1,premixed with bituminous binder @5.40% by weight of total mix and filler, transported at site with VTS, laid over a previously prepared surface, finished to the required grade ,level, alignment, and rolling to achieve the desired density for 50millimeter compacted thickness with drum mix plant with SCADA, Sensor paver and Vibratory roller excluding prime/Tack coat excetra. complete --Bitumen of specified grade with stone dust filler. (VG-30 bulk bitumen rates are considered to arrive at rates) |
| 705 | Two Track Two Glass Shutter Window :Providing and fixing aluminium color anodized system sliding window of various sizes. Window will be made from Geeta / Malwin/Lexil/Brandson, 25 to 27 millimeter slim series or equivalent System. Windows will be of specially extruded aluminium 2 Track - 2 Glass shutter window/ ventilator, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202screws. Glass shutter will be made from specially extruded aluminium section, glass considered is5 millimeter clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniformhairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, excetra. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories completeBasement floor |
| 706 | Ground floor |
| 707 | First floor |
| 708 | Four Track Three Glass + One Net Shutter Window: Providing & Fixing Aluminium System anodized sliding windows of various sizes. Sliding will be made from Geeta / Malwin/Lexil/Brandson, 27 millimeter Slim series or equivalent system. Windows will be of specially extruded aluminium 4 Track -3 Glass + 1 net shutter with Bottom Fixed. Fixed Glass at Bottom as per drawings would be fixed on 40millimeter Casement Series Frame section & Single glass Glazing clip both having 45° Joints with special cleats & fixed to missionary by SS 202wood screws. The Sliding Window Track mounted on Special Square Aluminium section, The track fra me will be fixed to the masonry opening of windows with SS 202 wood screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 6 millimeter clear Toughened Glass. All shutters will be having 45° joints, joints will be fixed with specially developed clits to form uniform hairline joint. All Shutter will be fixed to the main frame with necessary double roller to have smooth & easy movement of the shutter. Shutters will have single point self pressing lock. Windows will be sealed with weather sealant from outer periphery,excetra. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories completeGround floor |
| 709 | First floor |
| 710 | Second floor |
| 711 | Third floor |
| 712 | Fourth floor |
| 713 | Fifth floor |
| 714 | Sixth Floor |
| 715 | Seventh floor |
| 716 | Eighth floor |
| 717 | Nineth floor |
| 718 | Tenth floor |
| 719 | Eleveth floor |
| 720 | Twelevth floor |
| 721 | Aluminium System Color Anodized Partly Fixed partly Openable Window : Providing and fixing aluminium system color anodized Partly Fixed partly Openable window of various sizes. Casement will be made from Geeta / Malwin/Lexil/Brandson,40 millimeter series or equivalent System. Windows will be of specially extruded aluminium section, joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 wood screws. Fixed glass casement will be made from specially extruded aluminum section, glass considered is5 millimeter clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniformhairline joint. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, excetra. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories completeGround floor |
| 722 | First floor |
| 723 | Second floor |
| 724 | Third floor |
| 725 | Fourth floor |
| 726 | Fifth floor |
| 727 | Seventh floor |
| 728 | Nineth floor |
| 729 | Eleveth floor |
| 730 | Openable Shutters/Windows in Structural/Curtain Glazing : Providing and fixing openable shutter in structural glazing work of 5millimetertk tented toughened glass with frame workmade of aluminum RHSof size 64millimeter x 58millimeter color anodized as per design and drawing, aluminum sections should be confirming IS 63400 , glass pasted to frame work with 3M VHB tape and DOW CORNING 995 silicon sealantand gaps between glass panels should be filled by clear Dow CORNING 789 silicon weather proofing sealant , with good quality SS friction hinges, rubber gaskets handlesall necessary fasteners and accessories complete including With 24” Heavy S.S. Friction Hinges, Heavy Handles & 1\" window Handle Section of approved make, shade all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories completeGround floor |
| 731 | First floor |
| 732 | Second floor |
| 733 | Third floor |
| 734 | Three Track Three Glass Shutter Window :Providing and fixing aluminium system color anodized sliding window of various sizes. Window will be made from Geeta / Malwin/Lexil/Brandson, 25 to 27 millimeter slim series or equivalent System. Windows will be of specially extruded aluminium 3Track - 3 Glass shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202screws. Glass shutter will be made from specially extruded aluminium section, glass considered is5 millimeter clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniformhairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, excetra. complete.First floor |
| 735 | Three Track Two Glass + One Net Shutter Window :Providing and fixing aluminium system color anodized sliding window of various sizes. Window will be made from Geeta / Malwin/Lexil/Brandson, 25 to 27 millimeter slim series or equivalent System. Window will be of specially extruded aluminium 3Track - 2 Glass + 1 net shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202screws. Glass shutter will be made from specially extruded aluminium section, glass considered is5 millimeter clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniformhairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, excetra. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete First floor |
| 736 | Second floor |
| 737 | Third floor |
| 738 | Fourth floor |
| 739 | Fifth floor |
| 740 | Sixth Floor |
| 741 | Seventh floor |
| 742 | Eighth floor |
| 743 | Nineth floor |
| 744 | Tenth floor |
| 745 | Eleveth floor |
| 746 | Twelevth floor |
| 747 | Solid Core Flush door Single leaf Providingandfixingfactorymadesolid coreflushdoorinsingleleaf35millimeterthick,decorativetypes,of exterior grade, as per detailed drawings, conforming to Indian Standard:2202 - 1962 (Revised) with approved face Laminate on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessarybeads,mouldingandlipping,holdfasts,matfinishstainlesssteelfixturesfastenings,finishing withfrench-polish/waxingcomplete.(withoutdoorframe).(SampletobegotapprovedfromEx.Engineer before use) Comillimeterercial Hard Wood shutter Second floor |
| 748 | Third floor |
| 749 | Fourth floor |
| 750 | Fifth floor |
| 751 | Sixth Floor |
| 752 | Seventh floor |
| 753 | Eighth floor |
| 754 | Nineth floor |
| 755 | Tenth floor |
| 756 | Eleveth floor |
| 757 | Twelevth floor |
| 758 | Providing and laying Vitrified tiles (Matt and Antiskid Finish) in floor in 600milimeter x 1200milimeter sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid on 20 milimeter thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kilogram/sqm including grouting the joints with white cement and matching pigments excetra. The tiles must be cut with the zero chipping diametermond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.as directed by engineer-in-charge. Ground floor |
| 759 | First floor |
| 760 | Second floor |
| 761 | Third floor |
| 762 | Fourth floor |
| 763 | Fifth floor |
| 764 | Sixth floor |
| 765 | Seventh floor |
| 766 | Eighth floor |
| 767 | Nineth floor |
| 768 | Tenth floor |
| 769 | Eleventh floor |
| 770 | Twelveth floor |
| 771 | Providing and laying Vitrified tiles (Matt and Antiskid finish) in floor in 800milimeter x 1200milimeter sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid on 20 milimeter thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kilogram/sqm including grouting the joints with white cement and matching pigments excetra. The tiles must be cut with the zero chipping diametermond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.as directed by engineer-in-charge. Ground floor |
| 772 | Providing & layingwooden basedmatt finished Vitrified tiles of approved colour having size 190 to 200millimeter x 1200millimeterand 8 to 10 millimeter thick for flooring. Required sample is needs to get approved from the project Architect before execution on site. Work shall be carried ourincluding all lead and lifts excetra as directed by Engineer-In-Charge. Ground floor |
| 773 | Wall cladding with Terracotta desiner jali ; Designing ,supplying and fixing of Terracotta desiner jali of Nuvocottoor Equivalent make of size having 200x200x60millimeter as per manufacturer finished with approved colour and pattern . The blocks shall be fixed by suitable system by using mortar or special ready mix mortar or adhesive per manufacturer guidelines and specifications with suitablable thickness of joining material, size and spacing to withstand the structural design criteria specified, supported or locked by beams or columns as per design height criteria of the cladding as per manufacturer technical specification,Cladding joints should be with as per design and drawingsincluding cutting, jointing, fixing, scaffolding, cleaning, lead, lifts, handling excetra. complete as shown in design, drawings and specifications as directed by engineer & In charge.Sample needs to get approved from project architect before execution of work. Ground floor |
| 774 | First floor |
| 775 | Second floor |
| 776 | Third floor |
| 777 | Fourth floor |
| 778 | Fifth floor |
| 779 | Sixth Floor |
| 780 | Seventh floor |
| 781 | Eighth floor |
| 782 | Nineth floor |
| 783 | Tenth floor |
| 784 | Eleveth floor |
| 785 | Twelevth floor |
| 786 | Terrace floor |
| 787 | Galvanised Fins: Providing and fixing 300x75millimeter rectangular metal Fins made from 0.7millimeter GI Sheet with infill of honecombing foam, powder coated with pure polyester Matt finish exterior grade UV resistant powder coating for 10 years warranty. The fins have to withstand it\"s Self load and windspeed of 120kmph. The brackets 2millimeter or as required thick have to be camouflaged in the fins to give a thorough fin height from Ground to Top floor. Brackets to be fixed to the substructure or civil work using Ceramic coated or SS anchors studs. The fins to be connected to the brackets using wafer head SS Screws. Provision to be made water drainage through the fins to prevent any future rusting. The entire system has to be backed up by a structural stability report from a Chartered Engineer. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on site. Work shall be carried ourincluding all lead and lifts excetra as directed by Engineer-In-Charge. Ground floor |
| 788 | First floor |
| 789 | Providing and installating the Statue of maximum size 2m wide x 2m long x 3m high of granite stone material as per the design and drawing provided by the Architect including all required cutting, grinding, finishing, polishing excetra. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on site. Work shall be carried our includingall lead and lifts excetra complete as directed by Engineer-In-Charge. |
| 790 | Providing and applying Texture Plaster Of STONETEX - TRAVERTINE SERIES -ST-2002special luxurious stone finish coating (3 product type – 6 coat system) for exteriors and interiors. Texture midcoat incorporating natural stone granules like natural Sandstone, Granite, Limestone, Ceramic chips, natural sand excetra. including grooves to be provide as per design and drawings. Apply two coats of under coat primer by roller or brush then apply masking tape to create grooves as per design and drawings. First coat of texture midcoat finish by spray gun, evenly over the entire surface. Apply second coat of texture midcoat finish by spray sprinkle method, evenly on the whole sea of the previously dried first coat. Apply two coats of top protective coat evenly on the surface including grooves with roller or brush. It should be water based and ecofriendly product including preparing the surface, scaffolding excetra. complete as directed by Engineer in-charge Basement floor |
| 791 | Ground floor |
| 792 | First floor |
| 793 | Second floor |
| 794 | Third floor |
| 795 | Fourth floor |
| 796 | Fifth floor |
| 797 | Sixth Floor |
| 798 | Seventh floor |
| 799 | Eighth floor |
| 800 | Nineth floor |
| 801 | Tenth floor |
| 802 | Eleveth floor |
| 803 | Twelevth floor |
| 804 | Terrace floor |
| 805 | Suppling and fixing Mural work in combination of alluminium perforated panel and sheet with powder coating or duco paint with lacquer coat for rust free and long life.Each design will be attached to a metal sheet as a backilogramround guard.The design will be in a relief work upto 75millimeter from the wall.Thickness of wall material will defer as per requrement.Job should be strictly workout as project architect guild line excetra complete as per directed by Engineer In charge. Ground floor |
| 806 | First floor |
| 807 | Providing & Fixing Aluminium colour anodized sliding & folding door 3 shutters having special patented frame & shutter profiles.Oter frame profles being fixed to the missionary with SS-202 screw shutters having 45 degree corner joints with special cleats for linear joints having 6millimeter toughned glass are installed in the frame structure with mortise lockat opening, Top & bottom pivots for sliding,but hinges for folding operation & subsidiary multi point locking & pop handle for additional security,complete.Ground floor |
| 808 | First floor |
| 809 | Providing and fixing double shutter glass door of required size of 12millimeter thick toughen glass frosting and edge polish as shown in the drawings or as directed,including all necessary fittings like hydraulic patch fittings, Top pivot,door handle,door lock,door stopper,door soft central 180 weather seal for door edges excetra all complete as per architectural drawingsand directions of the Engineers-in- charge with all neccessary fastners and accessories complete . Ground floor |
| 810 | First floor |
| 811 | Second floor |
| 812 | Third floor |
| 813 | Alluminium System colour anodized Fixed window- Providing and fixng alluminium system colour anodized fixed window of various sizes.Casement will be made from Geeta,Malwin/Lexil/Brandson,40millimeter series or equivalent system window will be of specially extruded alluminium section,joints will be of 45 degree joints,joints will be fixed with specially developed clits.Track frame will be fixed to the masnory opening of windows with S S 202 wood screws.Fixed glass casement will be made from specially extruded alluminium section,glass considered is 5millimeter clear toughned glass. All shutter will be having 45 degree joints,joints will be fixed fixed with specially developed clits to form uniform hairline joints.All fixing screws will be of SS 202 windows will be sealed with weather sealant from outer periphery excetra complete. Ground floor |
| 814 | First floor |
| 815 | Second floor |
| 816 | Third floor |
| 817 | Fourth floor |
| 818 | Fifth floor |
| 819 | Sixth Floor |
| 820 | Seventh floor |
| 821 | Eighth floor |
| 822 | Nineth floor |
| 823 | Tenth floor |
| 824 | Eleveth floor |
| 825 | Twelevth floor |
| 826 | Providing and fixingCNC cutting MS jali having 4millimeter thick with powder coating with necessary fiitings required as per detailes provided by architect.Location of MS jali work will be as per drawing including lead ,lift excetra complete as per directed by Engineer In charge. Second floor |
| 827 | Third floor |
| 828 | Providing & fixing Luxalon SL4 84R plain panel sun louvers Of approved color consisting of panel 84millimeter wide 16millimeter deep x 0.6millimeter thick with round edges panel length up to 6 Mt coil coated on continues paint Line double baked & roll formed from enameled corrosion resistance. Aluminium Alloy AA3005 (Al. Mg.) for higher strength & good roll forming characteristics Panel shall be clipped to baked enameled aluminium SL-4 panel stringer of 33 millimeter wide & 86millimeter deep X 0.95 millimeter thick in a standard Length of 5 Mt made of double baked enameled Aluminium alloy AA5050 (Al. Mg.) black with cut-outs to hold the panel in a module of 86millimeter center to center at a distance of 1 Mt. The Carrier shall be fixed to suitable structure by means of rigid fixing details including Paint Finish : Aluminium panels shall be cromotised for maximum bond between metal & paint enameled twice under high temperature one side with full primer & luxacoat finish. The other side (Inner side) with a primer coat & skin coat on a continuous paint line excetra.complete as directed by Engineer-in-charge. Ground floor |
| 829 | First floor |
| 830 | Providing ,fixing,testing and comillimeterisioning of turbo ventilators of approved make of size 24\" self propelled fans having stainless steel 430 grade body with approximate weight 4.85 kilogram., having a CFM-7KM per hours-2440 with blade length 360millimeter wings of 80millimeter. including cutting roofing sheet,making the joints water tight,including all quality fastenings,fixing with self tapping screws from Buildtex, internal butt strap inlayed gasket,metal washers and Neoprene/EPDM washers,scaffoldings excetra. complete. Location of Turbo vent as per drawing excetra. complete. (Turbo vent should be Self-lubricating bearing)Fourth floor |
| 831 | S.S. Railing : Providing and Fixingmatt finished stainless steel (Grade 304) railing with 60milimeter x 40milimeter and 1.6milimeter thick pipe as handrail at top, 40milimeter x 8milimeter vertical patti placed at 1148 milimeter center to center, 40milimeter x 8milimeter horizontal patti placed at bottom 100 milimeter above the flooring,12milimeter diametermeter pipe placed vertically in between handrail and bottom patti at 150milimeter c/c and 75milimeter c/c alternately as shown in the drawing. including buffing, fabricating fixtures and fastening includingbase or cover plate of appropriate size as directed by Engineer in charge excetra. Complete. Basement floor |
| 832 | Ground floor |
| 833 | First floor |
| 834 | Second floor |
| 835 | Third floor |
| 836 | Fourth floor |
| 837 | Fifth floor |
| 838 | Sixth Floor |
| 839 | Seventh floor |
| 840 | Eighth floor |
| 841 | Nineth floor |
| 842 | Tenth floor |
| 843 | Eleveth floor |
| 844 | Twelevth floor |
| 845 | Terrace floor |
| 846 | Providing and fixing glass door size 1.0meter/1.2meter x 2.7meter single leaf shutter of 12 milimeter thick toughen glass frosting and edge polish as shown in the drawings or as directed , including all necessary fittings like hydraulic patch fitting, top patch fittings, Top pivot, door handle,door lock, door stopper, door soft central 180 weather seal for door edges excetra. complete as directed by Engineer -IN-ChargeFirst floor |
| 847 | Second floor |
| 848 | Third floor |
| 849 | Providing and fixing 12 milimeter thick toughen glass and edge polish as shown in the drawings or as directed, including all necessary fittings like Upper glazing profile, bottom lockingglazing profile, standard gasket for profile, locking Gasket 12milimeter, door soft central 180 weather seal for glass edges as per drawingshaving glass fixing sections at all sides concealed in partitions excetra. complete as directed by Engineer -IN-Charge. gaps between glass panels should be filled by clearsilicon weather proofing sealant , EPDM gaskets, handlesall necessary fasteners and accessories complete.as directed by engineer-in-charge. Ground floor |
| 850 | First floor |
| 851 | Second floor |
| 852 | Third floor |
| 853 | Providing and fixing Ivory Opal series European type wall-hung of size 400 millimeter X 370 millimeter X 575millimeter with approved make flush valveincluding soil pipe, vent pipe upto outside face of wall, 100millimeter dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors excetra as directed by Engineer in charge. Ground floor |
| 854 | First floor |
| 855 | Second floor |
| 856 | Third floor |
| 857 | Fourth floor |
| 858 | Fifth floor |
| 859 | Sixth Floor |
| 860 | Seventh floor |
| 861 | Eighth floor |
| 862 | Nineth floor |
| 863 | Tenth floor |
| 864 | Eleveth floor |
| 865 | Twelevth floor |
| 866 | Providing and fixingOrissa Pan of size 580 X 445 X 260 millimeter with approved make flush valve including trap, C.I. soil andvent pipe upto outside face ofwall including 100millimeter dia.C.I. plug, bend and necessary pipe connection, excetra complete. As directed by Engineer in charge. Ground floor |
| 867 | Providing and fixingIvory wash basin with half pedestal of size 515millimeter X 615millimeter X 460 millimeter including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipe connection upto the outside face of the wall. Ground floor |
| 868 | First floor |
| 869 | Second floor |
| 870 | Third floor |
| 871 | Providing and fixingOval Type Under Counter Wash Hand Basin of 420 x 590 x 195millimeter sizewith pillarcock,C.P.Angularstopcock,longthreadofapprovedmakecontinental includingSSbottletrapof necessarypipeconnectionuptotheoutsidefaceofthewall, havingTelephonicBlack/ColourGraniteof180millimeterthickfixedonBlackKadappa Framework, excetra. Complete as directed by Engineer in charge. Ground floor |
| 872 | Second floor |
| 873 | Third floor |
| 874 | Fourth floor |
| 875 | Fifth floor |
| 876 | Sixth Floor |
| 877 | Seventh floor |
| 878 | Eighth floor |
| 879 | Nineth floor |
| 880 | Tenth floor |
| 881 | Eleveth floor |
| 882 | Twelevth floor |
| 883 | Providing and fixing Ivory glazed urinal with Pressmatic auto closing valvehaving flow rate up to 4.0 Litr/Minute of Jaquar / Cera / Hindware / Perryware or equivalent make with Poly Vinyl Chloride waste pipewith fittingarrangement excetra.complete as directed by Engineer in charge. ( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) First floor |
| 884 | Second floor |
| 885 | Third floor |
| 886 | Fourth floor |
| 887 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut excetra. complete. Ground floor |
| 888 | First floor |
| 889 | Second floor |
| 890 | Third floor |
| 891 | Fourth floor |
| 892 | Fifth floor |
| 893 | Sixth Floor |
| 894 | Seventh floor |
| 895 | Eighth floor |
| 896 | Nineth floor |
| 897 | Tenth floor |
| 898 | Eleveth floor |
| 899 | Twelevth floor |
| 900 | Providing and fixing C.P. BIB cock with wall flange of approvedmake including necessary sockets/ union nut excetra. complete as directed by Engineer in charge. Ground floor |
| 901 | First floor |
| 902 | Second floor |
| 903 | Third floor |
| 904 | Fourth floor |
| 905 | ProvidingandfixingC.P.2WayBIBcockwithwallflange ofapproved makeincluding necessary sockets/ union nut excetra. complete as directed by Engineer in charge. Ground floor |
| 906 | First floor |
| 907 | Second floor |
| 908 | Third floor |
| 909 | Fourth floor |
| 910 | Fifth floor |
| 911 | Sixth Floor |
| 912 | Seventh floor |
| 913 | Eighth floor |
| 914 | Nineth floor |
| 915 | Tenth floor |
| 916 | Eleveth floor |
| 917 | Twelevth floor |
| 918 | Providing and fixing 15 millimeter diameter Poly vinyl Chloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories excetra complete Ground floor |
| 919 | First floor |
| 920 | Second floor |
| 921 | Third floor |
| 922 | Fourth floor |
| 923 | Fifth floor |
| 924 | Sixth Floor |
| 925 | Seventh floor |
| 926 | Eighth floor |
| 927 | Nineth floor |
| 928 | Tenth floor |
| 929 | Eleveth floor |
| 930 | Twelevth floor |
| 931 | Providing and fixing divertor with overhead shower,shower arm,spout,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalentmake including all necessary pipes,fittings excetra.complete as directed by Engineer In Charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) First floor |
| 932 | Second floor |
| 933 | Third floor |
| 934 | Fourth floor |
| 935 | Fifth floor |
| 936 | Sixth Floor |
| 937 | Seventh floor |
| 938 | Eighth floor |
| 939 | Nineth floor |
| 940 | Tenth floor |
| 941 | Eleveth floor |
| 942 | Twelevth floor |
| 943 | Providing and fixingsink cock with regular swinging spout (Wall / floor Mounted Model) with wall flange having flow rate up to6.0 Litr/Minute of Jaquar / Cera / Hindware / Perryware or equivalentmake incluidng other necessary fitting, excetra. complete as directed by Engineer in charge. (Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) Ground floor |
| 944 | First floor |
| 945 | Second floor |
| 946 | Third floor |
| 947 | Fourth floor |
| 948 | Providing andfixing 450millimeter x550millimeter size superiortype Belgium mirrorwith16millimeterdia. nickel plated towel rod excetra. complete. Ground floor |
| 949 | First floor |
| 950 | Second floor |
| 951 | Third floor |
| 952 | Fourth floor |
| 953 | Fifth floor |
| 954 | Sixth Floor |
| 955 | Seventh floor |
| 956 | Eighth floor |
| 957 | Nineth floor |
| 958 | Tenth floor |
| 959 | Eleveth floor |
| 960 | Twelevth floor |
| 961 | Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 millimeter and of DIA: 32millimeter and thickness 1.5millimeter of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BARof IZE-600millimeter (H) X600millimeter (D) and 32millimeter DIA. and thicknessmillimeter of the approved brand and make.27c) Straight grab bar (2 NOS)Providing S.STEEL 304 GRAB RAIL (600 millimeter),32millimeter DIA. and thickness 1.5millimeter of the approved brand and make. Ground floor |
| 962 | First floor |
| 963 | Second floor |
| 964 | Third floor |
| 965 | Fourth floor |
| 966 | Providingandfixing75millimeterdiastabiliserpipe/Poly Vinyl Chloridesoilvent/wastepipeandwith necessary fixtures andfitting such as bends, tees, single junctions, slotted vent, clamps excetra. Complete Ground floor |
| 967 | First floor |
| 968 | Second floor |
| 969 | Third floor |
| 970 | Fourth floor |
| 971 | Fifth floor |
| 972 | Sixth Floor |
| 973 | Seventh floor |
| 974 | Eighth floor |
| 975 | Nineth floor |
| 976 | Tenth floor |
| 977 | Eleveth floor |
| 978 | Twelevth floor |
| 979 | Terrace floor |
| 980 | Providingandfixing100millimeterdiastabiliserpipe/Poly Vinyl Chloridesoilvent/wastepipeandwith necessary fixtures andfitting such as bends, tees, single junctions, slotted vent, clamps excetra. complete. Ground floor |
| 981 | First floor |
| 982 | Second floor |
| 983 | Third floor |
| 984 | Fourth floor |
| 985 | Fifth floor |
| 986 | Sixth Floor |
| 987 | Seventh floor |
| 988 | Eighth floor |
| 989 | Nineth floor |
| 990 | Tenth floor |
| 991 | Eleveth floor |
| 992 | Twelevth floor |
| 993 | Terrace floor |
| 994 | ProvidingandfixingPoly Vinyl ChlorideRainwaterpipesof160millimeter & above (Preffered 250millimeter)outerdiameterandhavingwall thicknessof2.2to2.7millimeterconfirmingtoIndian Standard13592-1992includingproperrainwater receiving recess with Poly Vinyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25millimeter to 40millimeter from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket withsolventcementandproperlyrestingtheshoeofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Vinyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge excetra. complete. Ground floor |
| 995 | ProvidingandfixingPoly Vinyl ChlorideRainwaterpipesof160 millimeterouterdiameterandhavingwall thicknessof2.2to2.7millimeterconfirmingtoIndian Standard13592-1992includingproperrainwater receiving recess with Poly Vinyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25millimeter to 40millimeter from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket withsolvent cementandproperlyrestingtheshoeofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Vinyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge excetra. complete. Ground floor |
| 996 | First floor |
| 997 | Second floor |
| 998 | Third floor |
| 999 | Fourth floor |
| 1000 | Fifth floor |
| 1001 | Sixth Floor |
| 1002 | Seventh floor |
| 1003 | Eighth floor |
| 1004 | Nineth floor |
| 1005 | Tenth floor |
| 1006 | Eleveth floor |
| 1007 | Twelevth floor |
| 1008 | Terrace floor |
| 1009 | Providingandfixing15centi meter rigidPoly vinyl ChlorideNahanitrapincludingPoly vinyl Chloridegrating ,bend,connectingpieceofUnplasticized Poly vinyl Chloridepipeuptotheoutsidefaceofwall,makingthegood damaged surface and testing excetra. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Ground floor |
| 1010 | First floor |
| 1011 | Second floor |
| 1012 | Third floor |
| 1013 | Fourth floor |
| 1014 | Fifth floor |
| 1015 | Sixth Floor |
| 1016 | Seventh floor |
| 1017 | Eighth floor |
| 1018 | Nineth floor |
| 1019 | Tenth floor |
| 1020 | Eleveth floor |
| 1021 | Twelevth floor |
| 1022 | Providing andfixing onwalls/ceiling/floor 20millimeter dia.Chlorinated Poly vinyl Chloride pipe withnecessary fittings, remaking good the demolished portion excetra. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra. complete. Ground floor |
| 1023 | First floor |
| 1024 | Second floor |
| 1025 | Third floor |
| 1026 | Fourth floor |
| 1027 | Fifth floor |
| 1028 | Sixth Floor |
| 1029 | Seventh floor |
| 1030 | Eighth floor |
| 1031 | Nineth floor |
| 1032 | Tenth floor |
| 1033 | Eleveth floor |
| 1034 | Twelevth floor |
| 1035 | Providing and fixing on walls/ ceiling/ floor 25 millimeter dia. Chlorinated Poly vinyl Chloride pipe with necessary fittings, remaking good the demolished portion excetra. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra. complete. Ground floor |
| 1036 | First floor |
| 1037 | Second floor |
| 1038 | Third floor |
| 1039 | Fourth floor |
| 1040 | Fifth floor |
| 1041 | Sixth Floor |
| 1042 | Seventh floor |
| 1043 | Eighth floor |
| 1044 | Nineth floor |
| 1045 | Tenth floor |
| 1046 | Eleveth floor |
| 1047 | Twelevth floor |
| 1048 | Terrace floor |
| 1049 | Providing and fixing on walls/ ceiling/ floor 32 millimeter dia. Chlorinated Poly vinyl Chloride pipe with necessary fittings, remaking good the demolished portion excetra. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra. complete. Ground floor |
| 1050 | First floor |
| 1051 | Second floor |
| 1052 | Third floor |
| 1053 | Fourth floor |
| 1054 | Fifth floor |
| 1055 | Sixth Floor |
| 1056 | Seventh floor |
| 1057 | Eighth floor |
| 1058 | Nineth floor |
| 1059 | Tenth floor |
| 1060 | Eleveth floor |
| 1061 | Twelevth floor |
| 1062 | Terrace floor |
| 1063 | Providing and fixing on walls /ceiling/ floor 40 millimeter dia. Chlorinated Poly vinyl Chloride pipe with necessary fittings, remaking good the demolished portion excetra. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra. complete. Ground floor |
| 1064 | First floor |
| 1065 | Second floor |
| 1066 | Third floor |
| 1067 | Fourth floor |
| 1068 | Fifth floor |
| 1069 | Sixth Floor |
| 1070 | Seventh floor |
| 1071 | Eighth floor |
| 1072 | Nineth floor |
| 1073 | Tenth floor |
| 1074 | Eleveth floor |
| 1075 | Twelevth floor |
| 1076 | Terrace floor |
| 1077 | Providing and fixing on walls/ ceiling/ floor 50 millimeter dia. Chlorinated Poly vinyl Chloride pipe with necessary fittings, remaking good the demolished portion excetra. complete. Ground floor |
| 1078 | First floor |
| 1079 | Second floor |
| 1080 | Third floor |
| 1081 | Fourth floor |
| 1082 | Fifth floor |
| 1083 | Sixth Floor |
| 1084 | Seventh floor |
| 1085 | Eighth floor |
| 1086 | Nineth floor |
| 1087 | Tenth floor |
| 1088 | Eleveth floor |
| 1089 | Twelevth floor |
| 1090 | Terrace floor |
| 1091 | Providingandlayingintrenches50millimeterdai.Chlorinated Poly vinyl Chloridepipeincludingnecessaryexcavation, fittings. Refilling trenches excetra. complete. Including removing existing pipe line ifnecessary and conveying and stacking the same in PWD chowky or as directed excetra. complete. |
| 1092 | Providingandlayingintrenches50millimeterdia.heavygradehavingembossedasIndian Standard InstitutionMark galvanised iron pipes of 6.33 Kilogram/metre necessary fitting remaking good the demolished portionwithfilling trenchesandwithprimer ofanti-corrosive oilpaint ,2 coatscomplete. Including removing existing pipe line if necessaryandconveying andstacking the same in PWD chowky or as directed excetra. complete. |
| 1093 | Providingandlayingintrenches80millimeterdia.heavygradehavingembossedasIndian standard InstitutionMark galvanised iron pipes of 10.15 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra. complete. |
| 1094 | Providingandfixingscrewdownfor20millimeterdia.wheeledstoptapofbrassincluding necessary sockets/union nut complete. Ground floor |
| 1095 | First floor |
| 1096 | Second floor |
| 1097 | Third floor |
| 1098 | Fourth floor |
| 1099 | Fifth floor |
| 1100 | Sixth Floor |
| 1101 | Seventh floor |
| 1102 | Eighth floor |
| 1103 | Nineth floor |
| 1104 | Tenth floor |
| 1105 | Eleveth floor |
| 1106 | Twelevth floor |
| 1107 | Providingandfixingscrewdownfor25millimeterdia.wheeledstoptapofbrassincluding necessary sockets/union nut complete. Ground floor |
| 1108 | First floor |
| 1109 | Second floor |
| 1110 | Third floor |
| 1111 | Fourth floor |
| 1112 | Fifth floor |
| 1113 | Sixth Floor |
| 1114 | Seventh floor |
| 1115 | Eighth floor |
| 1116 | Nineth floor |
| 1117 | Tenth floor |
| 1118 | Eleveth floor |
| 1119 | Twelevth floor |
| 1120 | Terrace floor |
| 1121 | Providingandfixingscrewdownfor32millimeterdia.wheeledstoptapofbrassincluding necessary sockets/union nut complete. First floor |
| 1122 | Second floor |
| 1123 | Third floor |
| 1124 | Fourth floor |
| 1125 | Terrace floor |
| 1126 | Providingandfixingscrewdownfor40millimeterdia.wheeledstoptapofbrassincluding necessary sockets/union nut complete. Ground floor |
| 1127 | First floor |
| 1128 | Second floor |
| 1129 | Third floor |
| 1130 | Fourth floor |
| 1131 | Fifth floor |
| 1132 | Sixth Floor |
| 1133 | Seventh floor |
| 1134 | Eighth floor |
| 1135 | Nineth floor |
| 1136 | Tenth floor |
| 1137 | Eleveth floor |
| 1138 | Twelevth floor |
| 1139 | Terrace floor |
| 1140 | Providing andfixing 20millimeter diameterwatermeterwithnon-returnvalve includingstrainer, sockets/ union nut including water meter box making locking arrangement and lock. (without chamber). First floor |
| 1141 | Second floor |
| 1142 | Third floor |
| 1143 | Fourth floor |
| 1144 | Fifth floor |
| 1145 | Sixth Floor |
| 1146 | Seventh floor |
| 1147 | Eighth floor |
| 1148 | Nineth floor |
| 1149 | Tenth floor |
| 1150 | Eleveth floor |
| 1151 | Twelevth floor |
| 1152 | Providing andfixing 50millimeter diameterwatermeterwithnon-returnvalve includingstrainer,sockets/unionnutandincludingwatermeterboxmakinglockingarrangementandlock. [without chamber] Ground floor |
| 1153 | First floor |
| 1154 | Providing andfixing 80millimeter diameterwatermeterwithnon-returnvalve includingstrainer, sockets/unionnutandincludingwatermeterboxmakinglockingarrangementandlock.[Without chamber]. Ground floor |
| 1155 | Fourth floor |
| 1156 | Providing andmaking Indian Standard InstitutionMark ferrule connectionof50millimeter dia. to water mainincluding ferrulecouplingcastironbellmouthcover,builtinnonreturnvalveandfixingincluding excavation and reinstatement complete. Ground floor |
| 1157 | Providing andfixing 40 millimeter. dia Ball cock medium type with Poly vinyl Chloride float including sockets and necessary fittings and tested as per municipal requirements excetra. complete. Ground floor |
| 1158 | First floor |
| 1159 | Fourth floor |
| 1160 | Terrace floor |
| 1161 | Providing,constructingandfixing 250millimeterdia.InspectionchambermadeupofUPoly vinyl Chloride material of thickness 3.5 millimeter and height of 259 millimeter with inlet and outlet of 110 millimeter dia. with 75 millimeter dia. U Trap, Ultra shaft pipe of UPoly vinyl Chloride material having height of 470 millimeter and fixing Ultra 250 millimeter dia. Unplasticized Poly vinyl Chloride cover and frame in 150 millimeter thick in c.c.1:2:4, having crushed sand bedof100millimeterthickofsize550millimeterdia.Includingexcavationandrefillingthesidesof chamberbycrushedsandcushioning150millimeterthickness,connectingallrequiredUPoly vinyl Chloride fittings with rubber lubricant excetra. complete. |
| 1162 | Providing , constructing and fixing 450 millimeter dia. Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 millimeter and height of 388 millimeter with 160 or 200 millimeter main inlet (s) outlet and 110 and / or 160 millimeter branch inlets, with 450 millimeter dia. Ultra shaft pipe of HDPE material having height of 460 millimeter, having Reinforced Cement Concrete cover and frame fixing in 150 millimeter thick in c.c.1:2:4, having crushed sand bed of 150 millimeter thick of size 750 millimeter dia. Including excavation and refilling the sides of chamber by sand crushed cushioning 150 millimeter thickness, connecting all required UPoly vinyl Chloride fittings with rubber lubricant excetra. complete. |
| 1163 | Providing , constructing and fixing600 millimeter dia. Inspection chamber made up of Polypropylene/polyethylenematerialHaving315millimeterdiameterinlet(s)/outletsandwith eccentric reducers as per requirement to connect 160 millimeter and 200 millimeter pipes having thickness of5millimeterand600millimeterinheight,withinbuiltshaftachievetheinvertdepthaspersite condition of wall thickness of 5 millimeter having Reinforced Cement Concrete cover and frame fixing in 150 millimeter thick in c.c.1:2:4, having crushed sand bed of 150 millimeter thick of size 750 millimeter dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 millimeter thickness, connecting all required UPoly vinyl Chloride fittings with rubber lubricant excetra.complete. |
| 1164 | Providing , laying and fixing ,jointingEco- drain 110 millimeter SN 8 Nu- Drain UPoly vinyl Chloride pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per Indian Standard15328 with fittings such a bends, tees, coupler, excetra, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material excetra. complete. |
| 1165 | Providing , laying and fixing ,jointingEco- drain 160 millimeter SN 4 Nu- Drain UPoly vinyl Chloride pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per Indian Standard15328 with fittings such abends,tees,coupler,excetra,jointingwith rubberlubricantincludingnecessary excavation, trench refilling with selective excavated materialexcetra. complete. |
| 1166 | Providing and fixing 15centimeter x 10centimeter salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. |
| 1167 | Providing and laying concrete pipes of Indian Standard NP. class of 150millimeter diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 1168 | Providing and laying concrete pipes of Indian StandardNP. class of 225millimeter diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 1169 | Providing and laying concrete pipes of Indian Standard NP. class of 300millimeter diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 1170 | Providing and laying cement concrete pipe of Indian Standard 458:2003 NP-2 class of 450millimeter diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing excetra. complete. |
| 1171 | Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECOwith prior approval of concerned Superitending Engineer. |
| 1172 | RWH - Recharge PitProviding andconstructing rechargepitof2.0meter deepand1.0meter diameterofpre-castReinforced Cement Concreterings with6.5\"diax25meter deepborewellatthefloorofrechargepitincludinginstallationof combination of solid/perforated Poly vinyl Chloride casing pipe wrapped around with netlon mesh including 300millimeterthicksidefillingaroundoutsideofReinforced Cement Concreterings(annularspace)with40millimetersize bouldersincludingfillingofrechargepitupto0.5meterdepthwith25-75millimetercleanwashed gravels from bottom up followed by 0.5meter depth of 10-25millimeter of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed excetra.)includingnetlonmeshbetweeneachgravel/fineaggregate(naturalsand/crushedsand VSI grade finely washed excetra.) media layer including covering with Reinforced Cement Concrete slab, manhole frame & cover, Poly vinyl Chloride rungs, Poly vinyl Chloride end-caps, fittings excetra. including arrangement for inlet & outlet pipe excavation& backfilling as shownin the drawing.The rate shall be inclusive of alllabour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All materialshouldbeofapprovedmake.Allworkscompleteasperthedrawing,technical specification and direction of the Engineer in charge. |
| 1173 | Providing and constructing on sewer, Burnt.Brick. masonry circular manhole with concentric cone 1.2 M dia. at bottom and 0.5 M dia. at top and upto a depth of 2.00 M with 23 cm brick work in CM 1:4 proportion excluding excavation including foundation concrete 250 millimeter thick and haunches and channels in C.C. 1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kilogram., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C. frame and cover of 56 cm dia.excetra. complete as directed by Engineerin-charge. |
| 1174 | Providing and constructing on sewer, Burnt .Brick. masonry circular manhole concentric cone 1.5 Meter dia. at bottom and 0.5 Meter diameter. at top and upto a depth of 5.00 Meter with 23 centimeter brick work, upto depth of 2 Meter from top and 35 centimeter thick brick work for balance depth in Cement Mortar 1:4 proportion with 20 millimeter thick smooth plaster on both sides in Cement Mortar 1:2 proportion excluding excavation including foundation concrete 250 millimeter thick and haunches and channels in C.C. 1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kilogram., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C frame and cover of 56 cm dia. excetra. complete as directed by Engineerin-charge. |
| 1175 | Valve chamber with cast iron manhole frame and covers Providing and constructing Burnt Brick masonry valve chamber with 15 centimeter thick 1:3:6 proportion Plain Cement Concrete bedding, excluding excavation, Burnt Brick masonry in Cement Mortar 1:5 proportion, 12 millimeter thick cement plaster in Cement Mortar 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in Reinforced Cement Concrete 1:2:4 coping or Reinforced Cement Concrete 1:2:4 proportion x 15 centimeter thick slab, excetra. complete as directed by Engineer-in-charge. As above of 90 x 60 centimeter internal size and depth upto 1.2 Meter with 90 x 60 centimeter size Cast Iron manhole frame and cover of 50 kilogram. |
| 1176 | Valve chamber with cast iron manhole frame and covers Providing and constructing Burnt Brick masonry valve chamber with 15 cm thick 1:3:6 proportion Plain Cement Concrete bedding, excluding excavation, Burnt Brick masonry in CM 1:5 proportion, 12 millimeter thick cement plaster in Cement Mortar 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in Reinforced Cement Concrete 1:2:4 coping or Reinforced Cement Concrete 1:2:4 proportion x 15 cm thick slab, excetra. complete as directed by Engineer-in-charge. As above of 90 x 90 centimeter internal size and depth upto 1.2 Meter with 53 centimeter diameter Cast Iron manhole frame and cover of 90 kilogram. fixed in Reinforced Cement Concrete slab. |
| 1177 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPoly vinyl Chloride) Pipes of 62.50 millimeter nominal inner dia Pipes, having thermal stability for hot & cold water supply, including all CPoly vinyl Chloride plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPoly vinyl Chloride solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. |
| 1178 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPoly vinyl Chloride) Pipes of 75 millimeter nominal inner dia Pipes, having thermal stability for hot & cold water supply, including all CPoly vinyl Chloride plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPoly vinyl Chloride solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. |
| 1179 | Providing and Fixing it in position, Alighning to correct position, testing and comillimeterissioning of CP brass Grating (Viking 41615) of Rectangular type with openable circular lid 150 millimeter nominal size square 100 millimeter diameter of the inner hinged round grating. including setting in floor with cement motor to match with floor finish as per architect requirement complete including all accessories. All work Complete as per direction of the Engineer-in-Charge. |
| 1180 | Providing and Fixing it in position, Alighning to correct position, testing and comillimeterissioning of CP brass Gratingof Close on Top type (Viking 45290) with openable circular lid 150 millimeter nominal size square 100 millimeter diameter of the inner hinged round grating. including setting in floor with cement motor to match with floor finish as per architect requirement complete including all accessories. All work Complete as per direction of the Engineer-in-Charge. |
| 1181 | Providing and Fixing it in position, Alighning to correct position, testing and comillimeterissioning of CP brass P Trap 40millimeter Size for wash basin, Urinal & Kitchen Sinks. (Viking-5898 V6 H12)with all necessary fixtures and fittingexcetra complete as directed by the Engineer-in-Charge. (Fixtures and fittings as per Approved C.P & Sanitary Product sheet). All work Complete as per direction of the Engineer-in-Charge. |
| 1182 | Providing, fixing, testing and comillimeterissioning of Brass Housing Pressure Reduce Valve with balanced seat, standard pattern, set point scale, high quality synthetic material valve insert, SS wire mesh, NBR diaphragm, NBR seats, pressure gauge, complete as required in water supply drop pipes.To be installed inside shaft, on-line type. Pressure range Complete as per direction of the Engineer-in-Charge. ii) 25 mm dia |
| 1183 | iii) 32 mm dia |
| 1184 | iv) 40 mm dia |
| 1185 | vi) 50 mm dia |
| 1186 | vi) 65 mm dia |
| 1187 | Providingandfixing 600 millimeter long MS hot dip galvanized Puddel Flange fabricated out of 6 millimeter thick MS plates of suitable size and pipe shall be confirming to IS:1239 heavy class pipes properly fixed in walls / top slab of tanks.The entire fittings shall be hot dipped galvanized after fabrication.Length shall be minimum 600 millimeter or wall thickness plus 200 millimeter on either side (which ever is more). Each Puddle shall be flange at outer side for connection of pipe / fittings.All work Complete as per direction of the Engineer-in-Charge. i) 25 mm dia |
| 1188 | ii) 50 mm dia |
| 1189 | iii) 65mm dia |
| 1190 | iv) 80mm dia |
| 1191 | v) 100mm dia |
| 1192 | vi) 150mm dia |
| 1193 | vii) 200mm dia |
| 1194 | Royalty Charges for various building construction bonified materials which are used for government bonafied works and for which royalty charges are to be paid by the contractor. (This item is to be paid to the contractor only after he pays the royalty amount to revenue department and produces the required voucher. |
| 1195 | Royalty Cess 2.00% |
| 1196 | Contrubution towards district minarals foundation at the rate of 10 percent of prevlling rate of royalty for various building construction bonafied materials which are used for government bonafied works and for which royalty is to be paide by the contractor. |
| 1197 | Laboratory Testing Charges for Various materials required for items of work, on the basis of testing frequency and charges fixed by vigilance and quality Control Circle, Pune. SOIL & MURUM - SOIL / MURUM Compaction Test (Proctor Density). |
| 1198 | SOIL / MURUM Liquid limit & plastic Limit test. |
| 1199 | SOIL / MURUM Field Density test by Sand Replacement Method. |
| 1200 | SOIL / MURUM Sieve Analysis test. |
| 1201 | CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test. |
| 1202 | Concrete Mix Design (With all Tests onbasic materials). |
| 1203 | BASIC TEST OF AGGREGATE. Sieve Analysis test. |
| 1204 | BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test. |
| 1205 | FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test. |
| 1206 | BASIC TEST OF AGGREGATE. Water Absorption, Specific Gravity,Impact Value Crushing Value test. |
| 1207 | BASIC TEST OF AGGREGATE. Stripping Value test. |
| 1208 | BASIC TEST OF CEMENT.Standard ConsistancyFineness, Specific Gravity,Setting Time ( Initial & Final ), CompressiveStrength andSoundness test. |
| 1209 | STEEL BAR TESTINGUpto 16 mm(Set of 3 Bars) |
| 1210 | STEEL BAR TESTING Above 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress). |
| 1211 | BRICKS Water Absorption (Set of 5 Bricks), CompressiveStrength ( Set of 5 Bricks), Efflorescence (Set of 5 Bricks) test. |
| 1212 | MORTOR Compressive Strength( Set of 3 Cubes) test. |
| 1213 | CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test. |
| 1214 | FLOORINGof Natural stone(Kota/Marble/Granite/Tandur etc.) Water Absorption, Specific Gravity test. |
| 1215 | WOOD Density, Moisture Content test. |
| 1216 | CONCRETE PAVING BLOCKS Compressive Strength,Water Absorption test (Set of 8 Blocks). |
| 1217 | BITUMEN Penetration, Softening Point, Flash & Fire Point and Specific Gravity test. |
| 1218 | BITUMEN Viscosity test. |
| 1219 | BITUMEN Extraction Test. |
| 1220 | G.S.B. Mix Design test. |
| 1221 | SOIL / MURUM C.B.R. Test (Lab) with compaction test. |
| 1222 | BITUMEN B.M.Job Mix Design with all Tests on aggregate (Excluding bitumen). |
| 1223 | Density test of Bituminous Core. |
| 1224 | Sieve analysis of Bituminous mix (2 Samples of extraction for one sieve analysis including extraction) |
| 1225 | STONE/ RUBBLECrushing Value/Compressive Strength,Water Absorption & Specific Gravity test. |
| 1226 | diesel generating set with alternator of 250 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply,a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 42.30 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 425 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspectoras per specification no. GEN-DG[11-1-18] |
| 1227 | diesel generating set with alternator of 320 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 54.89 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 480 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG[11-1-19] |
| 1228 | microprocessor based AMF panel suitable for diesel generating set of above 200 kVA up to 250 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.[11-2-15] |
| 1229 | microprocessor based AMF panel suitable for diesel generating set of above 250 kVA up to 320 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.[11-2-16] |
| 1230 | Supplying, installing & testing Supplying, installing & testing maintenance free earthing comprising of Electrode of 17.2 mm diameterLow Carbon Steel with 250 micronmolecular copper bonded earthing rod ofLength 3malong with 25 kg Carbonbased environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 1231 | Supplying and erecting Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessarycopperclampsfixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. |
| 1232 | Supplying and erecting Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 1233 | Supplying and erecting Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 1234 | Supplying and erecting Supplying and erecting conventionalspike typeair termination suitable to carry lightning stroke made up of heavy gauge40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipeerected on provided foundation complete. |
| 1235 | Supplying and laying (including excavation)Supplying and laying (including excavation)reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 1236 | Supplying, erectingandmarking Supplying, erectingandmarking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1237 | Supplying, erectingandmarking Supplying, erectingandmarking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1238 | Supplying, erectingandmarking Supplying, erectingandmarking SPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1239 | Supplying, erectingandmarking Supplying, erectingandmarking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1240 | Supplying, erectingandmarking Supplying, erectingandmarking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1241 | Supplying, erectingandmarking Supplying, erectingandmarking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1242 | Supplying, erectingandmarking Supplying, erectingandmarking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB |
| 1243 | Supplying and erecting Supplying and erecting triplepole and neutral distribution board (TPNDB),SPMCB of 4 ways/phase(12 poles), with door,1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GIframe (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 1244 | Supplying and erecting Supplying and erecting triplepole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flushmounted,IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 1245 | Supplying and erecting Supplying and erecting triplepoleand neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flushmounted,IP 43 Protection on iron/GI frame (horizontal busbar type)as per specification no. SW-SWR/MCBDB |
| 1246 | Supplying and erecting Supplying and erecting triplepole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flushmounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 1247 | Supplying and erecting Supplying and erecting triplepoleand neutral distribution board (TPNDB), SP/TP MCBs total 12 ways /36 poles, with door, 1.2mm thickness surface/flushmounted, IP 43 Protection on iron/GIframe (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 1248 | Supplying and erecting Supplying and erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 1249 | Supplying and erecting Supplying and erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs,with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 1250 | Supplying and erecting Supplying and erecting blankingplate of suitable size on MCBDB. |
| 1251 | Supplying and erecting Supplying and erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 1252 | Providing and erecting Providing and erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 1253 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning of2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivitywithearth leakage trip indicationcomplete as per specification no. SW-RCCB/RCCB |
| 1254 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning of2 pole RCCB 63A, electromagnetictype with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 1255 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning of4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 1256 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning of4 pole RCCB 40A, electromagnetictype with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 1257 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning of4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication completeas per specification no. SW-RCCB/RCCB |
| 1258 | Supplying and erecting Supplying and erecting quartz electronic timeswitchhaving 24 hour dial to work on 250 V 50 cycle AC having built in rechargeablenickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16A to use independently or in conjunction with contactor. |
| 1259 | Supplying and erecting Supplying and erecting four pole power contactor 430 V, 16 Afor time switch complete erected on provided wooden block/ box, with necessary materials. |
| 1260 | Supplying, erecting & terminating Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 1261 | Supplying, erecting & terminating Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core4sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 1262 | Supplying, erecting & terminating Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6 sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 1263 | Supplying, erecting & terminating Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10 sq. mm. copperconductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 1264 | Supplying, erecting & terminating Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 1265 | Supplying, erecting & terminating Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core2.5sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 1266 | Supplying, erecting & terminating Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core4sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 1267 | Supplying and erecting Supplying and erecting PVCboxtrunking ofsize 100x50 mm. with accessorieson wall/ceiling as per specification No: WG-MA/BOX . |
| 1268 | Supplying and erecting Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC |
| 1269 | Supplying and layingSupplying and layingHMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC |
| 1270 | Supplying and erecting Supplying and erecting 25 mm dia. corrugated flexiblepolypropyleneconduit |
| 1271 | Supplying and erecting Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 1272 | Supplying and erecting Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 1273 | Supplying and erecting Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 1274 | Supplying and erecting Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 1275 | Supplying and erecting Supplying and erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 1276 | Supplying and erecting Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 1277 | Supplying and erecting Supplying and erecting modular type switch 16Aduly erected on provided plate and box with wiring connections complete. |
| 1278 | Supplying and erecting Supplying and erecting modular type switch 16 / 20 Awith indicator,duly erected on provided plate and box with wiring connections complete. |
| 1279 | Supplying and erecting Supplying and erecting modular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 1280 | Supplying and erecting Supplying and erecting modular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. |
| 1281 | Supplying and erecting Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 1282 | Supplying and erecting Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. |
| 1283 | Supplying and erecting Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 1284 | Supplying and erecting Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 1285 | Supplying and erecting Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 1286 | Supplying and erecting Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 1287 | Supplying and erecting Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 1288 | Supplying and erecting Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 1289 | Point wiring Point wiring for light/bellhybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls)in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 1290 | Point wiring Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls)in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 1291 | Secondary point wiring for additionallight/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW [1-7-22] |
| 1292 | Supplying and erecting Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 1293 | Supplying and erecting Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50,including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 1294 | Supplying and erecting Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12Wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 1295 | Supplying and erecting Supplying and erecting ready to use Retrofit T8 LED 18 / 20 tube lightwith polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8/ T12LED luminaire by disconnecting starter & ballast if necessary. |
| 1296 | Supplying and erecting Supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. |
| 1297 | Supplying and erecting Supplying and erecting 3W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 1298 | Supplying and erecting Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50,including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 1299 | Supplying and erecting Supplying and erecting LEDPanel Light(600mm X 600mm) Max. 35 Whaving CRCA powder coated housing,polystyrene diffuser havingsystem lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 1300 | Supplying and erecting Supplying and erecting LED Strip light 5m Length Max. 45 W IP20 class having minimumlumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg.,THD<10%, p.f. >0.95, operating range of230-270V, Life class of 30,000 Hrs. at L70B50, including driver with 1 year warranty. |
| 1301 | Supplying Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty. |
| 1302 | Supplying and erecting Supplying and erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt,CRI>80, CCT of 6500K and THD<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. |
| 1303 | Supplying and erecting Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. |
| 1304 | Supplying and erecting Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 1305 | Supplying and erecting Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% without IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF |
| 1306 | Supplying and erecting Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 1307 | Providing and erecting Providing and erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 1308 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning of20kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS |
| 1309 | Supplying and erecting Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 1310 | Supplying and erecting Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. |
| 1311 | Supplying and erecting Supplying and erecting SupplyInstallationtesting and commissioning of cubical type MV Panel conform toIEC:61439-I as pertechnical specifications single line diagram & approval of Drawings prior to manufacturingpacked in wooden crates with PVC sheets inner packingtransport to sitecompartmental cubicle type freestanding with appropriate cable entriesfront operatingfront maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved colorfeeder piller should be with supporting anglesself-locksgasket and slanting top to be erected on provided foundationPanel Details :- Name - Utility Panel Girls and Boys HostelDuty -Duty: Indoor Type (IP 42)Incomer-1 Nos of 315A FP MCCB Busbar - 315A TPN Al Busbar Outgoings - 13 Nos of 63A TP MCCB2 Nos of 100A TP MCB 3 Nos of 16A TP MCB |
| 1312 | Supplying and erecting Supplying and erecting SupplyInstallationtesting and commissioning of cubical type MV Panel conform toIEC:61439-I as pertechnical specifications single line diagram & approval of Drawings prior to manufacturingpacked in wooden crates with PVC sheets inner packingtransport to sitecompartmental cubicle type freestanding with appropriate cable entriesfront operatingfront maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved colorfeeder piller should be with supporting anglesself-locksgasket and slanting top to be erected on provided foundationName - Utility Panel Office BldgDuty -Duty: Indoor Type (IP 42)Incomer-1 Nos of 315A FP MCCBBusbar -315A TPN Al Busbar Outgoings - 8 Nos of 63A TP MCCB 13 Nos of 40A TP MCB6 Nos of 25A TP MCB |
| 1313 | Supplying and erecting Supplying and erecting SupplyInstallationtesting and commissioning of cubical type MV Panel conform toIEC:61439-I as pertechnical specifications single line diagram & approval of Drawings prior to manufacturingpacked in wooden crates with PVC sheets inner packingtransport to sitecompartmental cubicle type freestanding with appropriate cable entriesfront operatingfront maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved colorfeeder piller should be with supporting anglesself-locksgasket and slanting top to be erected on provided foundation Name - Utility Panel Museum BldgDuty -Duty: Indoor Type (IP 42)Incomer-1 Nos of 20A FP MCCBBusbar -200A TPN Al Busbar Outgoings - 10 Nos of 40A TP MCB,7 Nos of 25A TP MCB 3 Nos of 6A TP MCB4 Nos of 10A SP MCB |
| 1314 | Supplying and erecting Supplying and erecting SupplyInstallationtesting and commissioning of cubical type MV Panel conform toIEC:61439-I as pertechnical specifications single line diagram & approval of Drawings prior to manufacturingpacked in wooden crates with PVC sheets inner packingtransport to sitecompartmental cubicle type freestanding with appropriate cable entriesfront operatingfront maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved colorfeeder piller should be with supporting anglesself-locksgasket and slanting top to be erected on provided foundationHVAC Panel Incomer: 250A FP MCCB Busbar: 250A AL busbar.Outgoing: 3 No of 40A TP MCB10 Nos 25A FP MCB3 Nos 16A FT MCB |
| 1315 | Supplying, erecting, testing and commissioning ofSupplying, erecting, testing and commissioning ofself contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC |
| 1316 | Supplying and erecting Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) |
| 1317 | Supplying and erecting Supplying and erecting Dewatering Monoblock pump set 415V, 3 phase, 50C/s, A.C. supply of 2.25KW/ 3 H.P., of 12 to 26 m head with 560 to 70 LPM discharge, 10.5mm Solid Handling Capacity,non clogging minimised abrasive wear, large impeller clearance & maintenance free pump set with water proof cable duly sealed with epoxy material built in protection to prevent the motor from burn out due to abnormal operation. specially designed high efficiency motor with F class insulation & the pump mechanically sealed in the oil chamber,. etc. complete as per specification no. DWP- SMP |
| 1318 | Supplying and erecting Supplying and erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload elementwith necessary materials and connected to supply up to 7.5 H.P. |
| 1319 | Supplying and erecting Supplying and erecting pump protection relay comprising current sensing phase failure and UV+OV relay with dry run and overload protection suitable for 3 phase pumps. |
| 1320 | Supplying and erecting Supplying and erecting Water level controller 230/415 V, A.C. , Two way under ground tank operation only. |
| 1321 | Supplying and erecting Supplying and erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only. |
| 1322 | Supplying and erecting Supplying and erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos) |
| 1323 | Supplying and erecting Supplying and erecting non return valve 25 mm dia in position made of gun metal complete. |
| 1324 | Supplying and erecting Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. |
| 1325 | Supplying and erecting Supplying and erecting non return valve 65 mm dia in position made of gun metal complete. |
| 1326 | Supplying and erecting Supplying and erecting Providing & Fixing 40mm dia. Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nutsbolts and wahsers complete as required.All work Complete as per direction of the Engineer-in-Charge. (R.A CPWD Electrical -2018 16.7.4.8) |
| 1327 | Supplying and erecting Supplying and erecting Providing & Fixing 50mm dia. Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nutsbolts and wahsers complete as required.All work Complete as per direction of the Engineer-in-Charge. (R.A CPWD Electrical -2018 16.7.4.7) |
| 1328 | Supplying and erecting Supplying and erecting Providing & Fixing 65mm dia. Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nutsbolts and wahsers complete as required.All work Complete as per direction of the Engineer-in-Charge. (R.A CPWD Electrical -2018 16.7.4.6) |
| 1329 | Supplying and erecting Supplying and erecting Supplyingfixingtesting and commissioning of following sizes 65mm dia Motorized Butter fly Valve with CI BodySS Disc O - ring and minimum PN-16 pressure rating conforming to BS 5155IS 13095with IP-55 actuatorcapable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required. (R.A CPWD Electrical -201816.11.3.9) |
| 1330 | Supplying and erecting Supplying and erecting Supplyingfixingtesting and commissioning of following sizes 50mm dia Motorized Butter fly Valve with CI BodySS Disc O - ring and minimum PN-16 pressure rating conforming to BS 5155IS 13095with IP-55 actuatorcapable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required. (R.A CPWD Electrical -201816.11.3.10) |
| 1331 | Supplying and erecting Supplying and erecting Supplyinstallationtesting and commissioning of Skid mounted Hydro-pneumatic system of Vertical in line pump set with Variable Frequency Drive . Domestic Water Supply System For Building - (Location - Pump Room) Capacity per pump - 150 lpmHead - 60 meter (Approx. 4.5hp /pump) Pump Qty - 3 (2 working +1 stand by / Duty Assist) Siemens switch gear make control panel along withPLC PID Controller withall necessary cascade system automationPower & Control MCBMPCB Over load \ Under loadSPP \ RPPDry run and all necessary pump & voltage protectionIndication lamp Digital Pressure indicator cum controller.Danfoss make Pressure Transmitter & Pressure switchGaugePressure Tank etc. Skid for pumpset with Hot deep GalvnisedSuction & Delivery Header Plumbing Accessories along with Ball ValveNRVY type StrainerPolycab make power cable for pumpset & Control cablefloat switch sensor control cable for sensoretc complete as per direction of Engineer-in-charge. Pumpset & Control Pannel shall be company assembled factory fitted system with test certificate should be submitted. Vendor to submit performance curves and technical catalog of the proposed model for review & approval by consultants. |
| 1332 | Supplying and erecting Supplying and erecting Supplyinstallationtesting and commissioning of Skid mounted Hydro-pneumatic Drinking Water Supply SystemFor Building - (Location - Pump Room)Capacity per pump - 125 lpmHead - 60 meter (Approx. 3.7hp /pump) Pump Qty - 2 (1 working+1 stand by / Duty Assist)Siemens switch gear make control panel along withPLC PID Controller withall necessary cascade system automationPower & Control MCBMPCB Over load \ Under loadSPP \ RPPDry run and all necessary pump & voltage protectionIndication lamp Digital Pressure indicator cum controller.Danfoss make Pressure Transmitter & Pressure switchGaugePressure Tank etc. Skid for pumpset with Hot deep GalvnisedSuction & Delivery Header Plumbing Accessories along with Ball ValveNRVY type StrainerPolycab make power cable for pumpset & Control cablefloat switch sensor control cable for sensoretc complete as per direction of Engineer-in-charge. Pumpset & Control Pannel shall be company assembled factory fitted system with test certificate should be submitted. Vendor to submit performance curves and technical catalog of the proposed model for review & approval by consultants. |
| 1333 | Supplying and erecting Supplying and erecting Supplyinstallationtesting and commissioning of Skid mounted Hydro-pneumatic Flushing Water Supply SystemFor Building - (Location - Pump Room)Capacity per pump - 125 lpmHead - 60 meter (Approx. 3.7hp /pump) Pump Qty - 3 (2 working+1 stand by / Duty Assist)Siemens switch gear make control panel along withPLC PID Controller withall necessary cascade system automationPower & Control MCBMPCB Over load \ Under loadSPP \ RPPDry run and all necessary pump & voltage protectionIndication lamp Digital Pressure indicator cum controller.Danfoss make Pressure Transmitter & Pressure switchGaugePressure Tank etc. Skid for pumpset with Hot deep GalvnisedSuction & Delivery Header Plumbing Accessories along with Ball ValveNRVY type StrainerPolycab make power cable for pumpset & Control cablefloat switch sensor control cable for sensoretc complete as per direction of Engineer-in-charge. Pumpset & Control Pannel shall be company assembled factory fitted system with test certificate should be submitted. Vendor to submit performance curves and technical catalog of the proposed model for review & approval by consultants. |
| 1334 | SITC of Electric Traction Passenger Liftwith · Rated capacity :- 10 Passenger/680Kg· Floors :-G+12 floor (13 Stops/13 Landings) · Travel :- 21 to 29.4 mtrs · Location of Lift Machine:- MR/MRL· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 900 mm wide x 2000 mm high· Clear Carsize of1300 mm wide x 1350 mm deep x2250mm high · Lift shaft available having clear size of2000 mm wide x 2000 mm deep, 1500 mm Pit depth,4500 mm Overhead. · Doorstype :- COPO/TOPO Doors with framemade from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.· Lift controller of simplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters,The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proofDome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20\" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machineof Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixingsteel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.\"· General: - Job includes entire procedure of obtaining all necessary erection permissions & \"\"License to Work the Lift\"\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.\" Add on A1 ( 2337800 + ( 148207 x 5 ) = 3078835 ) [17-1-14] |
| 1335 | SITC of Electric Traction Passenger Liftwith · Rated capacity :- 10 Passenger/680Kg· Floors :- B+ G+4 floor (6 Stops/6 Landings) · Travel :- 22.2 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 900 mm wide x 2000 mm high· Clear Carsize of1300 mm wide x 1350 mm deep x2250mm high · Lift shaft available having clear size of2000 mm wide x 2000 mm deep,1500 mm Pit depth 4500…mm Overhead. · Doorstype :- COPO/TOPO Doors with framemade from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or outputetc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters.The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proofDome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machineof Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixingsteel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.\"· General: - Job includes entire procedure of obtaining all necessary erection permissions & \"\"License to Work the Lift\"\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning Add On 1 ( 1299498 + ( 141837 x 4 ) = 1866846 )[17-1-4] |
| 1336 | SITC of Electric Traction Passenger Liftwith · Rated capacity :- 8 Passenger/544Kg· Floors :-G+3 floor (4 Stops/4 Landings) · Travel :- 13.8 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0 mps VS· Car/Landing doorclear opening of 800 mm wide x 2000 mm high· Clear Carsize of 1300 mm wide x 1100.mm deep x2250mm high · Lift shaft available having clear size of 1900.mm wide x 1900 mm deep,.1500 mm Pit depth,4500 mm Overhead. · Doorstype :- COPO/TOPO Doors with framemade from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or outputetc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters.The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proofDome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machineof Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixingsteel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.\"· General: - Job includes entire procedure of obtaining all necessary erection permissions & \"\"License to Work the Lift\"\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.\" Add On 11087600 +( 137031 x 2 ) -=1361662 ) [17-1-3] |
| 1337 | Supplying and erecting Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 1338 | Supplying and erecting Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 1339 | Supplying and erecting Supplying and erecting mains with 1x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 1340 | Supplying and erecting Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 1341 | Supplying and erecting Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 1342 | Supplying and erecting Supplying and erecting modular type switch 16Aduly erected on provided plate and box with wiring connections complete. |
| 1343 | Supplying and erecting Supplying and erecting modular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 1344 | Supplying and erecting Supplying and erecting modular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. |
| 1345 | Supplying and erecting Supplying and erecting PVC Surface modular switch box with double mounting plate for 6module duly erected. |
| 1346 | Supplying and erecting Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 1347 | Wiring Wiring for plug on board withSwitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW |
| 1348 | Point wiring Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW |
| 1349 | Point wiring Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW |
| 1350 | Supplying and erecting Supplying and erecting bulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 1351 | Supplying and erecting Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17Wwith high transitivity diffuser withsystem lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%,p.f. >0.95, operating range of120-270V, surge protection of 4 kV, Life class of50,000 Hrs. at L70B50, includingdriver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 1352 | Providing Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. |
| 1353 | Supplying and erecting Supplying and erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC |
| 1354 | Supplying and erecting Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 1355 | Supplying and erecting Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF |
| 1356 | Supplying, erectingandmarking Supplying, erectingandmarking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1357 | Supplying, erectingandmarking Supplying, erectingandmarking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1358 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning of2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivitywithearth leakage trip indicationcomplete as per specification no. SW-RCCB/RCCB |
| 1359 | Supplying and erecting Supplying and erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 1360 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning of4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication completeas per specification no. SW-RCCB/RCCB |
| 1361 | Supplying and erecting Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 1362 | Supplying and erecting Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. |
| 1363 | Supplying, erecting & terminating Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core4sq mm copper conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 1364 | Supplying, erecting & terminating Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10 sq. mm. copperconductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 1365 | Supplying and erecting Supplying and erecting G.I. pipe‘A’ class 40 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE |
| 1366 | Supplying, installing & testing Supplying, installing & testing maintenance free earthing comprising of Electrode of 17.2 mm diameterLow Carbon Steel with 250 micronmolecular copper bonded earthing rod ofLength 3malong with 25 kg Carbonbased environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 1367 | Supplying and erecting Supplying and erecting annealed bare copper wireof high purity of required sizesused forearthing onwall with necessarycopperclampsfixedon wall/cable/conduitwithscrews complete. |
| 1368 | Providing and erecting Providing and erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 1369 | Supplying and erecting Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as perspecification no.OH-PL/HM (excluding luminaries) |
| 1370 | Supplying and erecting Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. |
| 1371 | MakingM- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 T/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). [16-3-9] |
| 1372 | Supplying and erecting Supplying and erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A,powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / CC foundation. |
| 1373 | Supplying and erecting Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete. |
| 1374 | Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). [16-3-12] |
| 1375 | Supplying and erecting Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV |
| 1376 | Supplying, erecting & terminating Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6 sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 1377 | Providing and erecting Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 1378 | Providing and erecting Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 1379 | Providing Providing pipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP |
| 1380 | Supplying and erecting Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing,having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. |
| 1381 | Providing Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP |
| 1382 | Supplying and laying (including excavation)Supplying and laying (including excavation)of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. |
| 1383 | Supplying, erectingandmarking Supplying, erectingandmarking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB |
| 1384 | Supplying, erecting & terminating Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 1385 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofmain fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacityfor manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation onwith IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/SSC/EP |
| 1386 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofjockey fire pump (JP)suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b)Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operationwith IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, asper specification no. FF-MFP/JP |
| 1387 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofbooster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operationwith IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevellingcomplete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP |
| 1388 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofmain fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speedsuitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 1389 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning offire pump control panel (FCP) of cubical constructionfloor mounted typefabricated from minimum 2 mm thick CRCA sheetcompartmentalised with hinged lockable doorswith enclosure protection class IP54duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)cable alleyinterconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessoriesmountings and internal wiring with adequate size copper conductor cableearth terminalsnumbering etc. complete in all respectsuitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessorieswiring & cabling along with allied accessorieswith following incoming and outgoingssuitable for automatic & manual operation on 415V3 phase50Hz ac supply as per specificationsthe capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standbyalternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFUsstarters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connectionsmounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handlewith HRC fuses of suitable rating.4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPPO/L & phase reversal protection with emergency stop switch.5. TPN SPD 100kA Type 1 +2 tested.6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps.7. System controller to control operation of main electric fire pumpjockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relaystimers. sensorsannunciation window for fault indicationcomplete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications.9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge.10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working)JP = (1working+1standbyalternate run per start in auto mode) complete panelasper specification no. FF-MFP/ECPFor addition of capacity of main electric motor driven fire pump MFP (1working) for hydrant system is more than 22kWadd as follows in the basiccost of Item no 13-5-1 towards increased capacity switchgears and motor startersfor main & jockey pumps along with necessary accessories for main & jockey firepumps MFP=(4 working)JP = ( 2 working + 1standbyalternate run per start inauto mode)Add For main electric motor driven fire hydrant system pump of 75kW capacity & relevant capacity jockey pump add Rs 99983/-For addition of fire sprinkler system to basic fire hydrant system control panel(FCP) which includes one main electric motor driven firepump MFP (1working) having __kW capacity& relevant capacity jockey pumpsadd as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgearsbusbar and additional motor starters for main & jockey pumps along with necessary accessories with software & hardware for main & jockey fire pumps additional Sprinkler system MFP (1working) @22kWJP (1working + 1standbyalternate run per start in auto mode) @relevant capacityFor main electric motor driven fire sprinkler system pump of 75kW capacity (1Working) & relevant capacity jockey pumps (1working+1standbyalternate run per start in auto mode add Rs304886 /-For addition of standby main diesel engine driven fire pump (1 standby)add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessoriesindicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode)& jockey fire pumps (1working+1standbyalternate run per start in auto mode) add Rs.68381/-for 5.5/ 7.5 kW centrifugal type booster pump 1no (1working)add Rs 17994 /- |
| 1390 | Supplying and erecting Supplying and erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload elementwith necessary materials and connected to supply up to 7.5 H.P. |
| 1391 | Supplying and erecting Supplying and erecting G.I. pipe‘C’ class ERW25 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1392 | Supplying and erecting Supplying and erecting G.I. pipe‘C’ class ERW50 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1393 | Supplying and erecting Supplying and erecting G.I. pipe‘C’ class ERW65 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1394 | Supplying and erecting Supplying and erecting G.I. pipe‘C’ class ERW75/80 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1395 | Supplying and erecting Supplying and erecting G.I. pipe‘C’ class ERW100 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1396 | Supplying and erecting Supplying and erecting G.I. pipe‘C’ class ERW150 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1397 | Providing Providing G.I. pipe‘C’ class ERW200 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1398 | Providing Providing coating of bitumen paint &4mm thick wrappingfor underground 100 mm ring main of fire fighting system. |
| 1399 | Providing Providing coating of bitumen paint &4mm thick wrapping for underground 150 mm ring main of fire fighting system. |
| 1400 | Providing Providing coating of bitumen paint &4mm thick wrapping for underground 200 mm ring main of fire fighting system. |
| 1401 | Excavating hard murum / stone metal roadby chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete. [16-1-6] |
| 1402 | Supplying and erecting Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen,end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete asper specification no. FF-VL/ELS |
| 1403 | Supplying and erecting Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SSscreen,end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete asper specification no. FF-VL/ELS |
| 1404 | Supplying and erecting Supplying and erecting 200 mm dia Cast Iron end line strainer of T-Pot type flanged end pattern, PN16 pressure rating, screen of SS and end connection with flanged, forpositive suction complete asper specification no. FF-VL/ELS |
| 1405 | Supplying and erecting Supplying and erecting 75/80mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV |
| 1406 | Supplying and erecting Supplying and erecting 100mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV |
| 1407 | Supplying and erecting Supplying and erecting 150mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV |
| 1408 | Supplying and erecting Supplying and erecting 200mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV |
| 1409 | Supplying and erecting Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 1410 | Supplying and erecting Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 1411 | Supplying and erecting Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 1412 | Supplying and erecting Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 1413 | Supplying and erecting Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 1414 | Supplying and erecting Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 1415 | Supplying and erecting Supplying and erecting 75/80 mm diacast iron double flange NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 1416 | Supplying and erecting Supplying and erecting 150 mm diacast iron double flange NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 1417 | Supplying and erecting Supplying and erecting 75/80 mm dia cast iron double flange ball type NRVcomplete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 1418 | Supplying and erecting Supplying and erecting 100 mm dia cast iron double flange ball type NRVcomplete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 1419 | Supplying and erecting Supplying and erecting 150 mm dia cast iron double flange ball type NRVcomplete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 1420 | Supplying and erecting Supplying and erecting 200 mm dia cast iron double flange ball type NRVcomplete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 1421 | Supplying and erecting Supplying and erecting 20 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV |
| 1422 | Supplying and erecting Supplying and erecting 25 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV |
| 1423 | Supplying and erecting Supplying and erecting 50 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV |
| 1424 | Supplying and erecting Supplying and erecting stainless steel single outlethydrantvalve fitted with necessary accessories complete asper specification no. FF-VL/HV |
| 1425 | Supplying and installingSupplying and installingwall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose)along with necessary accessories complete asper specification no. FF-FFA/HV |
| 1426 | Supplying and erecting Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m inlength, fitted with necessary accessories complete asper specification no. FF-FFA/RRL |
| 1427 | Supplying and erecting Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzlecomplete as per specifications no. FF-FFA/NZ |
| 1428 | Supplying and erecting Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete asper specification no. FF-FA/FBC |
| 1429 | Supplying and erecting Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete asper specification no. FF-FA/FMC |
| 1430 | Supplying and erecting Supplying and erecting 300 mm dia 1.5min heightair vessel / tankfabricated from min 5mm thick M.S. sheet complete asper specification no. FF-FFA/ACT |
| 1431 | Supplying and erecting Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I.coupling to be fitted on top of air vessel or on wet riser complete asper specification no. FF-FFA/ARV |
| 1432 | Supplying and erecting Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete asper specification no. FF-FFA/PG |
| 1433 | Supplying and erecting Supplying and erecting 12/15 mm dia pressureswitchwith provided isolationvalve,G.I. nipple, elbow, etc complete asper specification no. FF-FFA/PS |
| 1434 | Supplying and erecting Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer diawith required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP |
| 1435 | Supplying and erecting Supplying and erecting M.S./CRCA cabinet forhousingFireBrigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet andangleiron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8\" x 6\") andlocking arrangement with necessaryfixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 1436 | Supplying, erecting, testing and commissioning ofSupplying, erecting, testing and commissioning ofquartzoid bulb sprinkler, 15 mm (½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR. |
| 1437 | Supplying, erecting, testing and commissioning ofSupplying, erecting, testing and commissioning ofvane type water flow detector75/80 mm dia. with1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. |
| 1438 | Supplying, erecting, testing and commissioning ofSupplying, erecting, testing and commissioning ofvane type water flow detector100 mm dia. with1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. |
| 1439 | Supplying and erecting Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM. |
| 1440 | Supplying and erecting Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 1441 | Supplying and erecting Supplying and erecting Supplyinginstallationtesting & commissioning of Sprinkler Flexible Pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducernipple2 side bracketscenter bracketstockbar. The hose assembly includes 1200 mm long28 mm diameter corrugated stainless steel flexible hose with a braided stainless steel exterior.complete all the work up to the satisfaction of the Engineer in charge.(R.A. CPWD Electrical 18.25.3) |
| 1442 | Supplying and erecting Supplying and erecting Supplyinginstallingtestingand commissioning standard response Pendent / Upright type sprinkler (Standard coverage) quartzite bulb type with 15mm screwed end connection of 68 deg. C.tempersture rating K-80 and orifice shall not be less than 6mm sprinklers shall be UL listed approved with chrome finished.complete all the work up to the satisfaction of the Engineer in charge. (R.A. CPWD Electrical 18.21.2) |
| 1443 | Supplying and erecting Supplying and erecting Supplyinginstallingtestingand commissioning standard response Sidewall sprinkler (Standard coverage) quartzite bulb type with 15mm screwed end connection of 68 deg. C.tempersture rating K-80 and orifice shall not be less than 6mm sprinklers shall be UL listed approved with chrome finished.complete all the work up to the satisfaction of the Engineer in charge. (R.A. CPWD Electrical 18.21.3) |
| 1444 | Supplying and erecting Supplying and erecting Providing and fixing 150 mm dia installation valve with Hydraulic trim type automatic alarm to be connected with controlvalvedrainand test valveasper manufacturersrecommendations . with accessories like water motor gong bellTest & drain valve Flow switch etc UL listed etc complete to satisfaction of Architect/ PM (R.A.CPWD WR (2019) 21.3) |
| 1445 | Supplying and erecting Supplying and erecting Supplyinginstallingtestingand commissioning of portable fire extinguishers of ABC dry powder stored pressure type fire extinguishers of 6 Kgs.capacity Complete with standard discharge valve with tubeCI bracket for wall mounting etc. complete as per confirming to IS : 15683 complete all the work up to the satisfaction of the Engineer in charge. |
| 1446 | Supplying and erecting Supplying and erecting Supplying and erecting of Fire ExitFire Hydrant Hose BoxMCPHooterFire Alarm Control Panel & Fire Exinguisher signage Indicating the detail (FIRE SIGNAGES) |
| 1447 | Supplying and erecting Supplying and erecting Providinglayingtesting & commissioning of 80mm dia resilient rubber neoprene lined single arch Vibration eliminators (Expansion bellows) suitable for Design Pressure 16 kg/sq cm and test pressure 24 kg/sq cm. complete all the work up to the satisfaction of the Engineer in charge. |
| 1448 | Supplying and erecting Supplying and erecting Providinglayingtesting & commissioning of 150mm dia resilient rubber neoprene lined single arch Vibration eliminators (Expansion bellows) suitable for Design Pressure 16 kg/sq cm and test pressure 24 kg/sq cm. complete all the work up to the satisfaction of the Engineer in charge. |
| 1449 | Supplying and erecting Supplying and erecting Providing and fixing 25 mm dia Inspection & Testing Assembly with 25mm gunmetal ball valvegun metal sight glass bypass valve & connected to drain line etc complete as per drawing. |
| 1450 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofbeam smoke detector four wiresingle ended reflected type with 8 \" receiver having digital display for easy alignment, adjustable sensitivity & heater kit for transmitter/receiver and reflector with necessary connections on suitable back box. The protection range of beam detector is 5 to 70 m. |
| 1451 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofremote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete asper specification no. FF-FAAS/RRI |
| 1452 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofFR, XLPE armouredcable 4 core1.5 sq.mm. copper conductorcomplete erected on wall/ ceiling complete asper specification no. CB-LT/CU |
| 1453 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofmicro processor based intelligent addressable main fire alarm panel, central processing unit with the 2 loop capacity and capable of supportingupto 250 devices and detectorsper loop,with on-board LCD display with min 16 lines of text,operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ONinterface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/UL864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. |
| 1454 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofmicro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supportingupto 250 devices and detectorsper loop,with on-board LCD display with min 16 lines of text,operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ONinterface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/UL864 (10th edition)with 3 years replacement warranty FF-AFAS/CP. |
| 1455 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofrepeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than175 x 275 x 65 mm conforming to EN 54 or UL approvedwith 3 years equipment replacement warranty FF-AFAS/RP |
| 1456 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofaddressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approvedwith 3 years equipment replacement warrantyFF-AFAS/SD . |
| 1457 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofintelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area\"s etc. with 3 years equipment replacement warrantyIS : 2175 - 1988 reaffirmed 2000,IS 15908:2021 standards FF-AFAS/SD. |
| 1458 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofaddressablemanual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \"Break Glass\"massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listedwith 3 years equipment replacement warrantyFF-AFAS/MCP. |
| 1459 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofaddressable fire control/relay module complete as required, with 3 years equipment replacement warrantyconforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays,EN 54 or UL Listed FF-AFAS/CRM |
| 1460 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofaddressable fire monitor module complete as required. EN 54 or UL Listedwith 3 years equipment replacement warranty conforming toIS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM |
| 1461 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofaddressable fire isolator module complete as required.EN 54 /FM or UL Listedwith 3 years equipment replacement warranty conforming toIS 5051Part 2 (Sec 1 to 3) : 1982 Reed relaysFF-AFAS/ISM |
| 1462 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofaddressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage rangeEN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. |
| 1463 | Supplying and erecting Supplying and erecting HMS PVC conduit FRLS grade25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. |
| 1464 | Supplying and fixingSupplying and fixing17U floor mount rack (Dimension-DxWxH – 800x600x954 mm) as per specification No. WG-NAS/RAK |
| 1465 | Supplying, erecting, testing and commissioning ofSupplying, erecting, testing and commissioning of1.5 sq. mm speaker wire complete. |
| 1466 | Supplying and erecting Supplying and erecting Supplyinstallationtesting & commissioning of 6 Watt Cone type Ceiling Mounted metal grill Speakers with line matching transformerPower tapping: 1.5W/3W/6WFrequency response: 100-20000 Hz. SPL (1W 1m) 92 dBincluding screw clamp mounting with required accessories. (Colour - White) |
| 1467 | Supplying and erecting Supplying and erecting SupplyInstallationtesting and commissioning of 6 Watt Box type Wall / Surface Mount Speaker with line matching transformerPower tapping: 1.5W/3W/6WABS or metal bodyFrequency response: 100-20000 Hz. SPL (1W 1m) 92 dBincluding required mounting accessories. |
| 1468 | Supplying and erecting Supplying and erecting SupplyInstallationtesting and commissioning of 10 Watt column/wall mount Projector Speaker (uni directional) with line matching transformerPower tapping: 5W/10Wfire protected ABS or Metal cabinetincludes a steel U-bracketwith adjustable inclination and easy installation with required accessories. |
| 1469 | Supplying and erecting Supplying and erecting Supplyinstallationtesting & commissioning of 6 Zone Voice Alarm PA Controller with built in audio message generator (multi message)6 Zone 70/100V live outputs for Speaker circuitFireman MicrophonePre-recorded evacuation messagesShould be able to send 2 different pre-recorded messages simultaneously (message should be in 2 languages English & Hindi)Phased evacuation6 supervised input contact relays for integration with Fire Alarm Control PanelUp to 6 call stations can be connected together with controller. The controller should integrates multiple functions such as audio storageplaybackzone controlaudio monitoringscheduled broadcast and fault diagnosisaudio playingzone controlfault monitoringlog recordingvolume control and amplifier switchover etc. complete with cordsconnectors & required accessories. |
| 1470 | Supplying and erecting Supplying and erecting Supplyinstallationtesting & commissioning of 480 Watthigh efficiency Power amplifier70/100V loudspeaker output voltagesRMS output power limiterhigh temperatureDCshort circuitmains undervoltage protectionDC supply undervoltage protectioninrush current limiter with cords |
| 1471 | Supplying and erecting Supplying and erecting Supplyinstallationtesting & commissioning of 240 Watthigh efficiency Power amplifier70/100V loudspeaker output voltagesRMS output power limiterhigh temperatureDCshort circuitmains undervoltage protectionDC supply undervoltage protectioninrush current limiter with cordsconnectorspower supply & required accessories. |
| 1472 | Supplying and erecting Supplying and erecting Supplyinstallationtesting & commissioning of 6 Zone Call Station (Microphone) with built in numerical keypadgooseneck microphonezone selection keypad & having LED indication for zone selectionfault and emergency state with required cablecords & accessories. |
| 1473 | Supplying and erecting Supplying and erecting Supplyinstallationtesting & commissioning of Audio Music Player with built in USB portSD cardsupport MP3 & other audio formatscomplete with cablecords & required accessories. |
| 1474 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofsplit type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TRcapacity having ISEER minimum 5.00suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 1475 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofsplit type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC |
| 1476 | Supplying and erecting Supplying and erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigeranthaving 22SWG thickness and inner dia/size 16mm complete. |
| 1477 | Supplying, erecting, testing and commissioning ofSupplying, erecting, testing and commissioning of14HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 1478 | Supplying, erecting, testing and commissioning ofSupplying, erecting, testing and commissioning of22HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 1479 | Supplying, erecting, testing and commissioning ofSupplying, erecting, testing and commissioning ofVRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.8TR (594 cfm) to 2.2TR (655 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. |
| 1480 | Supplying, erecting, testing and commissioning ofSupplying, erecting, testing and commissioning ofVRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 1481 | Supplying, erecting, testing and commissioning ofSupplying, erecting, testing and commissioning ofVRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 4.1TR (1218 cfm) to 5.0TR (1624 cfm)of suitable cfm having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 1482 | Supplying, erecting, testing and commissioning ofSupplying, erecting, testing and commissioning ofVRF/VRV based ceiling suspended 2 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.8TR (1130 cfm) to 3.7TR ( 1377 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 1483 | Supplying, erecting, testing and commissioning ofSupplying, erecting, testing and commissioning ofcentralised programmable remote control panel (HMI) touch manager controls minimum 16 system of 64 ODU\"s can be controlled and up to 992 IDU\"s can be individually mounted and controlled indoor units having colour min 200mm size LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall integrated with provided fire alarm system. |
| 1484 | Supply, fabrication, installation and testing of Supply, fabrication, installation and testing of flexible canvas connections constructed between ductable unit/dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete. |
| 1485 | Providing Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2017. |
| 1486 | Providing & applying Providing & applying of acoustic insulation for air ducts with 25mm thick, 48 kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheets complete. |
| 1487 | Supplying and installingSupplying and installingof collar damper of galvanised iron material of upto 120 microns for anti corrosive resistance for supply air grill of suitable size. |
| 1488 | Supplying and installingSupplying and installingof high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system. |
| 1489 | Supplying and erecting Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°. |
| 1490 | Supplying, laying / fixing, testing and commissioning of Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1491 | Supplying, laying / fixing, testing and commissioning of Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete. |
| 1492 | Supplying, laying / fixing, testing and commissioning of Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1493 | Supplying, laying / fixing, testing and commissioning of Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1494 | Supplying, laying / fixing, testing and commissioning of Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1495 | Supplying, laying / fixing, testing and commissioning of Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1496 | Supplying and erecting Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. |
| 1497 | Supplying and erecting Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns withgalvanization process compliance to IS 2629:1985 tobeused for fabricationofboxespanelboardsetc. including cutting, bending, drilling, welding, riveting etc. and paintingwithone coat of red leadpaint and 2 coats of enamel paint. |
| 1498 | Supplying and erecting Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns withgalvanization process compliance to IS 2629:1985 tobeused for fabricationofboxespanelboardsetc. including cutting, bending, drilling, welding, riveting etc. and paintingwithone coat of red leadpaint and 2 coats of enamel paint. |
| 1499 | Supplying and erecting Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 1500 | Supplying and erecting Supplying and erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete. |
| 1501 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning of outdoor type floor mounted Double skin AHU comprising of 48 mm thick panel filled with PUFDIDW backward curved / airfoil fan with 2 ply fire retardant canvas at the outletcomplete with suitable motor and mounting arrangements on common rail anti vibration mountthermal break profileReturn air mixing chamber with fresh air and return air aluminum dampers DX type Cooling Coil - 2 circuits with capillery header / Electronic Expansion Valve to be connected with VRF/VRV ODU systemSS insulated drain panInlet Filter EU-5doors with proximity switch for inspection lamp and AHU stopincluding volume control damper and motorized fire damper with fire test control panel at AHU outlet installedPLC based Control logic Panel with possibilty of third party BMS connectivity for remote operationetc. The AHU shall have starter panel interconnected with fire panel for fire mode operationCapacity = 10500CFM / 50mmWg / 21.7TR |
| 1502 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning of ceiling suspended Double skin AHU comprising of 48 mm thick panel filled with PUFDIDW backward curved / airfoil fan with 2 ply fire retardant canvas at the outletcomplete with suitable motor and mounting arrangements on common rail anti vibration mountthermal break profileReturn air mixing chamber with fresh air and return air aluminum dampers DX type Cooling Coil - 2 circuits with capillery header / Electronic Expansion Valve to be connected with VRF/VRV ODU systemSS insulated drain panInlet Filter EU-5doors with proximity switch for inspection lamp and AHU stopincluding volume control damper and motorized fire damper with fire test control panel at AHU outlet installedPLC based Control logic Panel with possibilty of third party BMS connectivity for remote operationetc.The AHU shall have starter panel interconnected with fire panel for fire mode operationCapacity = 6500CFM / 50mmWg / 21.6TR |
| 1503 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning of ceiling suspended Double skin AHU comprising of 48 mm thick panel filled with PUFDIDW backward curved / airfoil fan with 2 ply fire retardant canvas at the outletcomplete with suitable motor and mounting arrangements on common rail anti vibration mountthermal break profileReturn air mixing chamber with fresh air and return air aluminum dampers DX type Cooling Coil - 2 circuits with capillery header / Electronic Expansion Valve to be connected with VRF/VRV ODU systemSS insulated drain panInlet Filter EU-5doors with proximity switch for inspection lamp and AHU stopincluding volume control damper and motorized fire damper with fire test control panel at AHU outlet installedPLC based Control logic Panel with possibilty of third party BMS connectivity for remote operationetc.The AHU shall have starter panel interconnected with fire panel for fire mode operationCapacity = 5000CFM / 50mmWg / 10TR |
| 1504 | Supplying and erecting Supplying and erecting Supplyinstallationtesting and commissioning of Vane Axial Smoke Exhaust Fans with Sound Attenuatorscomplete with drive and Supports system with vibration isolators. Fire rated H Class motor300 deg.C at 2 Hr. Motor shall be suitable for 415 ± 10% volts50 cycles3 phase AC supply and shall have high efficiency motorswith all supporting structures and accessorieswaether proof external exhaust louvers. Sound level shall not be more than 55 dBA from 3 m AMCA Certified only. For auditorium and multipurpose hallCapacity = 8300CFM / 20mmWg |
| 1505 | Supplying and erecting Supplying and erecting Supplyingerectingtesting & commissioning exhaust air systemductable circular inline exhaust air fan inlet unit having 500 cfm capacity with maintaining the static pressure minimum 30mm suitable to operate on 1ph230 V50HzA.C. supply complete. |
| 1506 | Supplying and layingSupplying and layingHMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC |
| 1507 | Supplying and erecting Supplying and erecting 25 mm dia. corrugated flexiblepolypropyleneconduit |
| 1508 | Supplying and erecting Supplying and erecting PVCboxtrunking ofsize 100x50 mm. with accessorieson wall/ceiling as per specification No: WG-MA/BOX . |
| 1509 | Supplying and erecting Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. |
| 1510 | Supplying and erecting Supplying and erecting modular type telephone socket one gangwith safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 1511 | Supplying and erecting Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. |
| 1512 | Supplying and erecting Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as perspecification No. WG-TW |
| 1513 | Supplying and erecting Supplying and erecting 5 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as perspecification No. WG-TW |
| 1514 | Supplying and erecting Supplying and erecting 20 pair, 0.5 mm dia. jelly filled armoured telephonecopper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed havinglaid in provided trench as per specification No. WG-TW |
| 1515 | Supplying and erecting Supplying and erecting 50 pair, 0.5 mm dia. jelly filled armoured telephonecopper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed havinglaid in provided trench as per specification No. WG-TW |
| 1516 | Supplying and erecting Supplying and erecting 100 pair, 0.5 mm dia. jelly filled armoured telephonecopper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed havinglaid in provided trench as per specification No. WG-TW |
| 1517 | Supplying and erecting Supplying and erecting 0.5 mm dia, copper jumper wire as per specification No. WG-TW |
| 1518 | Supplying and erecting Supplying and erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW |
| 1519 | Supplying and erecting Supplying and erecting 5m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 1520 | Supplying and erecting Supplying and erecting 10m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 1521 | Supplying and erecting Supplying and erecting 15m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 1522 | Supplying and erecting Supplying and erecting 20m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 1523 | Supplying and erecting Supplying and erecting 25m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 1524 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning ofMDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 1525 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning ofMDF Box 150x150 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 1526 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning ofMDF Box 500x500 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 1527 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning of10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 1528 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning of10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW |
| 1529 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning ofIP EPABX for 10 extensions complete. |
| 1530 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning ofpush button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete. |
| 1531 | Supplying, Erecting and Commissioning ofSupplying, Erecting and Commissioning ofIP telephone instrument as per specification complete. |
| 1532 | Supplying and installingSupplying and installingcat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 1533 | Supplying and installingSupplying and installingcat-6 armouredcable with ECCS tape suitable for networking as per specification No. WG-COC/NC |
| 1534 | Supplying and erecting Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 µm (OM3), suitable upto 10 GBPS, ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH |
| 1535 | Supplying and erecting Supplying and erecting LSZH armoured multimode optical fibre cable with 12 fibres, core dia 50/125 µm (OM3), suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC |
| 1536 | Supplying and fixingSupplying and fixing1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 1537 | Supplying and fixingSupplying and fixing2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC |
| 1538 | Supplying and pluging Supplying and pluging 3 m fibre patch cord LC-SC MM (50) OM3 LSZH duplex complete as per specification no. WG-COC/FPC |
| 1539 | Supplying, fixing, and configuringSupplying, fixing, and configuring8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete. |
| 1540 | Supplying, fixing, and configuringSupplying, fixing, and configuring24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS |
| 1541 | Supplying, fixing, and configuringSupplying, fixing, and configuring20 (1G-RJ45) ports + 4 combo 1G ports + 410G (SFP+) ports, Layer 3 switch, SI Image, 6KV surge protection on ethernet port and console port for management erected in provided rack complete. |
| 1542 | Supplying, fixing, and configuringSupplying, fixing, and configuring24 ports + (4 SFP+) POE switch, 370W, 6KV surge protection on ethernet port and console port for management on provided rack as per specification No. WG-NWC/ENS |
| 1543 | Supplying, fixing, and configuringSupplying, fixing, and configuring10G Base -SR (SFP+) simplex MM transceiver erected in provided rack complete. |
| 1544 | Supplying, fixing, and configuringSupplying, fixing, and configuringmodularised multi-service router 802.11/a/n/ac unified Wave 2.5 GHz, with RJ-45 port, supporting1 to 13 channels for 2.4 GHz, with unified wireless access point complete. |
| 1545 | Supplying, installing & testing Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 1546 | Supplying and fixingSupplying and fixingtool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 1547 | Supplying and fixingSupplying and fixing24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 1548 | Supplying and fixingSupplying and fixing12 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided U rack complete as per specification no. WG-NAS/LIU |
| 1549 | Supplying and fixingSupplying and fixingSC/LC type multimode pigtails (OM3) for LIU to terminate OFC in LIU as per specification No. WG-NAS/LIU2 |
| 1550 | Supplying and fixingSupplying and fixingPower Distribution Unit for networking rack comprises of 6/16A (6 Nos. sockets), 25 A modular MCB, appropriate rating fuse and indicator lamp, enclosed in black powder coatedmetal with necessary arrangement for fixingas per specification No. WG-NAS/RAK |
| 1551 | Supplying and fixingSupplying and fixing15U wall mount rack (Dimension-DxWxH – 500x600x767 mm) as per specification No. WG-NAS/RAK |
| 1552 | Supplying and fixingSupplying and fixing22 U floor mount rack (Dimension-DxWxH – 800x600x1176 mm) as per specification No. WG-NAS/RAK |
| 1553 | Supplying and fixingSupplying and fixing42U floor mount server rack (Dimension-DxWxH – 800x600x1866 mm) as per specificationNo. WG-NAS/RAK |
| 1554 | Supplying and fixingSupplying and fixing9U IP66 outdoor mount server rack with pole mount bracket (Dimension- DxWxH - 500x600x450 mm) as per specification No. WG-NAS/RAK |
| 1555 | Supplying and fixingSupplying and fixingdual-band manageable wireless 3x3 Mesh Router, high performance, 802.11 n/ac unified, concurrentaccess point with POE in networking as per specification no. WG-NAS/LAP2 |
| 1556 | Supplying, installing & activating Supplying, installing & activating physical license pack software for multiple access point with management, configuration and trouble shooting for all access point in network complete |
| 1557 | Supplying and erecting Supplying and erecting Supplying and fixing 2 m Telephone patch cord of RJ11 type |
| 1558 | Supplying and erecting Supplying and erecting Supplying and installingtesting & commissioning of Digital (Hybrid) type EPABX of 10 Digital + 450 analog extensionsbuilt in Compatible Software ServerUSB Portsinternal Storage upto 64GBGroup Conference facility. Voice Messagesethernet portsUniversal Slots for Interface expansion CardsSingle Line Analog Telephones portTrunk lineBRI portsGSM/3GPortsSIP Trunks port complete with required accessories. (Make- Matrix / Panasonic / Alcatel or equivalent) |
| 1559 | Supplying and erecting Supplying and erecting Supplyinstallationtesting & commissioning of Ceiling Mounted Smart LED Projector- Full HD1920 x 1080 Resolution3800 ANSI Lumens white/color outputVarifocal lens16 watt audio output10000:1 contrast ratioBuilt-in wireless and miracastHDMI 2 inputsVGA6000 hours unwoven filter12000 hours lamp lifeHDCR/AccentualizerRJ-45 portincluding Remote controlpower cordcablelens cover & required accessories with Ceiling mounted brackets. |
| 1560 | Supplying and erecting Supplying and erecting Supply & fixing of 150\" Diagonal Motorized white Screen for projector with motorfixing brackets & required accessories. |
| 1561 | Supplying and erecting Supplying and erecting Supplyinstallationtesting & commissioning of Smart TVWall mount 55\" Ultra HD Flat LED TV having minimum 2 HDMI2 USB & 1 RJ 45 portAV port with inbuilt Wi-Fi including wall mount accessories. |
| 1562 | Supplying and erecting Supplying and erecting Supplying Erecting Testing & Commissioning 5 MP Full IP Dome/Bullet Camera Complete. Camera Sensor 1/2.7\"5.0 megapixelprogressive scanCMOSLens [email protected] Distance 60 Meter DetectShutter Auto/Manual1 ~ 1/100000s Colour: 0.01Lux (F2.0AGC ON)Minimum Illumination 0Lux with IR onDigital noise reduction 2D/3D DNRDay/Night IR-cut filter with auto switch (ICR)S/N >52dBIR Range Up to 30m (98ft) IR rangeWavelength 850nmIR On/Off Control Auto/ManualDefog Digital DefogWDR DWDRVideo Video Compression Ultra 265H.265H.264MJPEGH.264 code profile Baseline profileMain ProfileFrame Rate Main Stream: 5MP (2592*1944)Max 20fps; Sub Stream: 720P (1280×720)Max 20fpsVideo Bit Rate 128 Kbps~16 MbpsOSD Up to 4 OSDsPrivacy Mask Up to 4 areasROI Up to 2 areasMotion Detection Up to 4 areasImage White Balance Auto/Outdoor/Fine Tune/Sodium Lamp/Locked/Auto2Digital noise reduction 2D/3D DNRSmart IR SupportFlip Normal/Vertical/Horizontal/180°Dewarping NAHLC SupportedBLC SupportedNetwork Protocols IPv4IGMPICMPARPTCPUDPDHCPRTPRTSPRTCPDNSDDNSNTPFTPUPnPHTTPHTTPSSMTPSSLQoSInterface 10/100M Base-TX EthernetCompatible Integration ONVIF (Profile SProfile T)APICertifications Certifications CE: EN 60950-1/UL: UL60950-1/FCC: FCC Part 15(Include – 12 Month Fully Compressive Warranty |
| 1563 | Supplying and erecting Supplying and erecting Supply of 64 Channel professinal series 4K HD Network Video Recorder Smart H265+/H265/Smart H264+ Max 320Mbps Incoming Bandwith upto 12MPResolution for Preview and Playback. Bit Rate 16Kbps-20Mbps per channel. 2HDMI/ 2VGA simultaneous video output to enhance the storagereliablity when the network break downQuad- Core embeded processor. 8 STATA III Ports upto 6 TB for each HDD for 2 RJ45 port (10/100/1000Mbps) independant of joint Networking. Analytical Features like - ANPRPeople CountFace DetectionMissing/ Abonded ObjectsTripwire and Instrsion alarmsSmart FAN to achive high cooling effects. Automatic Network Replenishment (ANR) Technology - Network Video Recorders with ANR function automatically store video data on an IP camera SD card when the Network is disconnected. After recovery of the networkthe NVR automatically retrives the video data stored on the camera. |
| 1564 | Supplying and erecting Supplying and erecting Supply and Installation of 8 TB (7200 RPM) Surveillance hard disk 8 TB storage capacity with SATA support 6GB/s NCQ 64 MB cache 3.5 inches. (for 30 days recording) |
| 1565 | Supplying and erecting Supplying and erecting SITC of42\" Full HD TV VGA DVL2 x HDMILAN2 xUSB RGS In out Avin Component in wit ready 20W speakers professional full HD display complete with mounting hardware and software 200 templete included to create your own content manage content with suggested PC or mobile device A professional display backed by three years onsite/offsite warranty and dedicated B2B support (3 years warranty) |
| 1566 | Supplying and erecting Supplying and erecting Supplyinstallationtesting & Comissioning of Front-of- House left and right clusters with a 14\" LF driver or better and multiple MF/HF drivers (More than 4)Biamplified 2 or 3 Way array loudspeaker system; with Individual Module free field Frequency Range (-10dB) of 55Hz - 18kHz or better & Continuous Power Handling of >= 750W LF + 150W MF/HF. The Loudspeaker module shall have a Max. SPL (Peak) of MF/HF>= 130 or better. It should have Horizontal near dispersion pattern of 80º or bettervertical dispersion of the array shall be 60 degrees or better. with OEM Couling plate for array modules |
| 1567 | Supplying and erecting Supplying and erecting Supplyinstallationtesting & Commissioning of a single 18\" subwoofer. The louspeaker shall meet the following performance criteria: Frequency Range (-10 dB) of 29Hz - 300Hz. It should have an ground stack position Sensitivity of > = 98dB (1W/1m) or more delivering a ground position Max. Calculated SPL(peak) of>=133 dB; Nominal impedance of 4ohm or higher and continuous Power Handling of 750W or more.The loudspeaker system shall be comprised of aBaltic birch plywood enclosure with standard array rigging hardware for Cardioid as well as stacked position |
| 1568 | Supplying and erecting Supplying and erecting Supplyinstallationtesting and commissioning of a two-way dual 6.5-inch or better Frequency Range (-10 dB) of80Hz - 18kHz or better; Nominal Dispersion : 90°H x 60°V or better; Power handling of 800W peak or more; Sensitivity of 90dB or better; Max SPL : 123dB Peak or more with aNominal impedence of 8 ohms. Standard wall mount brackets shall be included |
| 1569 | Supplying and erecting Supplying and erecting Supplyinstallationtesting & Comissioning ofpassive coaxial two-way point source loudspeaker with a single 8\" LF driver or better. Frequency Range (-10dB) of 75Hz - 20kHz or better & Continuous Power Handling of >= 150W or better. The Loudspeaker module shall have a Max. SPL (Peak) of MF/HF>= 128 or better. It should have Horizontal near dispersion pattern of 110º or bettervertical dispersion of the module shall be 60 degrees or better. |
| 1570 | Supplying and erecting Supplying and erecting Supplyinstallationtesting and commissioning of 8 channel class D Networkable Power amplifier with a Max Output Power of 8x500W@8 ohmsor bridged mode output power of 4x 1000W @ 8/4 ohms. 20Hz - 20 KHzSNR of 102dB and THD + N of <0.4% with built inprotection such as LimitersTemperatureDCShort CircuitPeak Current LimitersTurn on delayetc. Built in DSP for Matrix routingSpeaker equalizationDelaysArray EQs etccomplete with Ethernet Port for Network Controlprogramming and monitoring. Shall offer optional Network audio connectivity (Dante or CobraNet) through expansion slot. |
| 1571 | Supplying and erecting Supplying and erecting Supplyinstallationtesting and commissioning of Class D configurable amplifier with total 2 x 1000W output power or better across 2 outputs4/8ohms70/100 Voltor mixed use operation; Frequency Response : 20Hz - 20kHz for LZ mode ;THD <0.04% at rated output |
| 1572 | Supplying and erecting Supplying and erecting Supply installation testing and comissioning of Digital SoundProcessor with 8 Mic/Line inputs & 8 analog outputs24 Bit A-D and D-A Convertors; Sampling Rate : 48 kHz;THD : < 0.002 % ; Channel Separation (Crosstalk) : < 105 dB ; Frequency Response 20 Hz - 20 kHz ; Signal-to-Noise Ratio 80 dB ;Dynamic Range :> 115 dB; 5 Control Inputs and Outputs; RS-232 and Ethernet Port for third party Control and Monitoring; inbuilt DSP features like Input EqualizersRouterBand Pass filterOutput EqualizerDelayLimitersgatesFeedback suppressorsSource selectors etc. |
| 1573 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning Digital wireless handheld Microphone with UHF transmission greatly enhances rangereliability and scalability of 56 MHz Bandwidth will allow for up to 90 channels Up to 2 240 selectable frequencies with Mobile App streamlines setup and operation and eliminates complicated menus and Automated setup creates reliable connections with minimal time and effort Preserves every detail of even the most dynamic performances with 134 dB transmitter dynamic range Lithium Ion battery pack delivers up to 12 hours of operation (up to 8 hours of operation with AA batteries) Transducer principle dynamic with Pick-up pattern cardioidSound pressure level 154 dB SPLTransmit power (radiated) Audio link: 10 mW ERP (Range Y1-3: 12 mW ERP) BLE: max. 10 mW EIRP |
| 1574 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning Digital wireless headworn Microphone with UHF transmission greatly enhances rangereliability and scalability of 56 MHz Bandwidth will allow for up to 90 channels Up to 2 240 selectable frequencies with Mobile App streamlines setup and operation and eliminates complicated menus and Automated setup creates reliable connections with minimal time and effort Preserves every detail of even the most dynamic performances with 134 dB transmitter dynamic range Lithium Ion battery pack delivers up to 12 hours of operation (up to 8 hours of operation with AA batteries Transducer principle pre-polarized condensor microphone Pick-up pattern cardioidTransmit power (radiated) Audio link: 10 mW ERP (Range Y1-3: 12 mW ERP) BLE: max. 10 mW EIRP |
| 1575 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning Digital wireless Lapel Microphone with UHF transmission greatly enhances rangereliability and scalability of 56 MHz Bandwidth will allow for up to 90 channels Up to 2 240 selectable frequencies with Mobile App streamlines setup and operation and eliminates complicated menus and Automated setup creates reliable connections with minimal time and effort Preserves every detail of even the most dynamic performances with 134 dB transmitter dynamic range Lithium Ion battery pack delivers up to 12 hours of operation (up to 8 hours of operation with AA batteries Transducer principle pre-polarized condensor microphone Pick-up pattern cardioidTransmit power (radiated) Audio link: 10 mW ERP (Range Y1-3: 12 mW ERP) BLE: max. 10 mW EIRP |
| 1576 | Supplying and erecting Supplying and erecting Supplyinstallationtesting & commissioning of Gooseneck Microphone with connector XLR3MImpedance < 100 OhmDimensions L 450 mm (17 72\")Frequency response (microphone) 50Hz - 20 kHzTransducer principle (Microphone) pre polarised condenser microphonePick-up pattern cardioidEquivalent noise level 26 dB (A)Equivalent noise level weighted as per CCIR 468-3 37 dBMaximum sound pressure level (passiv) 130 dB SPLPower supply P48Current consumption 3 mAConnectorMic in: XLR-3FMic out: XLR-3M Logic: clip contact for logicPin assignment: trigger signal at the logic connector: Logic in (external LED control)GNDLogic out (switch signal)Current consumption 3.7 mA with On/Off Switch |
| 1577 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning of active antenna splitter 2× 1:4 or 1× 1: Frequency range: 470 – 870 MHz at –3 dB23 dBm typical Impedance 50 ? Reflection loss 10 dB (all RF outputs) Power consumption : 245 mA Total power consumption Max. 2A (4 receivers & 2 × 2 antenna amplifiers per antenna input) OEM should have authorized service centre in India |
| 1578 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning of directional antenna with Impedance:50 Ohm; Connector: BNC; Pick-up pattern: directional;Frequency range: 450 - 960 MHz ;Antenna gain: 4 dBi ;Opening angle: +- 50 degrees ; OEM should have authorized service centre in India |
| 1579 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning of cardiod pre-polarised condenser microphone with Frequency response of 20 - 20 000 HzSensitivity of 7 mV/Pa;2.3 mV/Pa / 0.7 mV/Pa(with pre-attenuation)Sound pressure level at 1 kHz of 137/147/157 dB SPL(depending on pre-attenuation)Nominal impedance 100 ohm Min. terminating impedance 1 k ohm OEM should have authorized service centre in India |
| 1580 | Supplying and erecting Supplying and erecting SupplyInstallationtesting and commissioning of cardioid pre-polarized condenser on-table boundary layer microphone with 3-pin XLR and a programmable microphone button for Toggle on/offPTMPTT and permanent on features with a bi-color LED ring for status indication and TTL logic connector with logic inputs and outputsfrequency response of 40 Hz - 20 000 Hz or better and sensitivity of 10 mV/Pa or betternominal impedance at 1 kHz of 200 ? or bettercurrent consumption of 5.3 mA or betterequivalent noise level of 26 dB(A) or betterdynamic range of 111 dB (A) or bettermaximum SPL of 140 dB or better and operating on 48 V phantom power. The logic output voltage shall be high level > 2.4 or better and low level < 0.4 V or better and logic input voltage shall be high level > 2.0 V and low level < 0.8 V. |
| 1581 | Supplying and erecting Supplying and erecting super-cardioid/interference tube mini shotgun microphone capsule for background noise suppression. a permanently polarized condenser microphone capsule with a hyper cardioid / lobar directivity.with the 15 cm short gooseneck stemImpedance 50 ?Frequency response (Microphone) to be 40 Hz to 20 kHzPhantom powering P12 to P48Equivalent noise level 23 dB(A)Equivalent noise level weighted as per CCIR 34 dB(A)Current consumption 250 ?A |
| 1582 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning of dynamic cardioid vocal microphone with ON/OFF switch and with frequency response of 40 Hz – 16 000 Hz and the sensitivity of 2.7 mV/Pa at 1 kHznominal impedance of 350 Ohm and min. terminating impedance of 1 k Ohm OEM should have authorized service centre in India |
| 1583 | Supplying, erecting & terminating Supplying, erecting & terminating SupplyInstallationTesting & Commissioning of 2 core 2.5 sq mm PVC Speaker Cable high quality twisted pair manufactured with bright annealed PVC Sheathed electrolytic oxygen free grade tinned copper conductorsbunched compactly |
| 1584 | Supplying, erecting & terminating Supplying, erecting & terminating SupplyInstallationTesting & Commissioning of 2 core shielded balanced microphone cable. |
| 1585 | Supplying, erecting & terminating Supplying, erecting & terminating SupplyInstallationTesting & Commissioning of 32 core shielded balanced microphone snake cable. |
| 1586 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning of Customized XLR Plates |
| 1587 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning of Custom made Audio Plates |
| 1588 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning of UL Listed Audio Connectors |
| 1589 | Supplying and erecting Supplying and erecting SupplyInstallationTesting & Commissioning of AC Voltage Input Range-180-270 VAC50/60Hz Maximum AC Current Rating-16 Amps (Thermal breaker) AC Cord: 1.5mm2x32.5m LongblackIEC C-19 Female to Schuko CEE 7/7 Male Plug AC Receptacles: Convenience Outlet (Front Panel) 1 IEC C-13 (Unswitched)Rear Panel Outlets: 1 IEC C 13 pair (Unswitched)3 IEC C13 pairs (Sequencedeach pair is controlled by separate relay)Surge/Under-Overvoltage Protection: AC Surge Protection: Series Multi-Stage Protection (SMP) Spike Protection Mode: Line to neutralzero ground leakage Response Time: 1 nanosecond Maximum Surge Current: 6 500 Amps Operating Temperature Range: 5C (40F) to 40C (105F) degrees |
| 1590 | Supplying and erecting Supplying and erecting Mixer 32 Mixing channels :32 Line Inputs (24 mono and 4 stereo);4 GROUP Buses + ST Bus;6 AUX Sends + 2 FX Sends;FX1:REV-X(8 PROGRAMPARAMETER control)/ FX2:SPX(16 PROGRAM PARAMETER control); 48V phantom power per channel; LINE: 24 mono + 4 stereoCH INSERT: 24 RETURN: 1 stereo; USB DeviceiPod / iPhone; +0.5/-1.0dB 20Hz - 20kHzNominal output level @1kHz |
| 1591 | Supplying and fixingSupplying and fixing24 U floor mount rack (Dimension-DxWxH – 800x600x1265 mm) as per specification No. WG-NAS/RAK |
| 1592 | Providing and erecting Providing and erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware. |
| 1593 | Supplying and erecting Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 1594 | Supplying and erecting Supplying and erecting mains with 4x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 1595 | Supplying and erecting Supplying and erecting SITC of 100W High Quality zoomable LED parcan Light complete with COB Lamp source 3200K CCT Colour temperatureCRI & TLCI Values above 90DmX 512 dimming with 2 channel controlBeam Angle of 11 to 35 DegreeBlack powder coated body. As per direction of authority Including Labour cess and Insurance. |
| 1596 | Supplying and erecting Supplying and erecting SITC of 200W LED Profile Spot 19 Degree Light complete with 3200K CCT Colour TemperatureCRI & TLCI above 90DmX 512 dimming with 1 or 3 Channel modesBlack finish housingIP20 protection having Lux @ 2 Mtrs above 27 000 suitable to illuminate the key presentor or talent on stage.As per direction of authority Including Labour cess and Insurance. |
| 1597 | Supplying and erecting Supplying and erecting SITC of 400W LED Blinder Light 30 Degree complete with 3200K CCT Lamp sourceDmX 512 dimming with 4 or 8 Channel modesBlack finish housingIP20 protection having Strobe option and smooth dimmingilluminate Stage with uniform light levels. As per direction of authority Including Labour cess and Insurance |
| 1598 | Supplying and erecting Supplying and erecting SITC of 54 x 3W LED Par Light 3 in 1 Beam Angle 25° complete with RGBW 3W Lamp source x 54 PcsDmX 512 dimming with 8 Channel Powder coatedBlack finish housing IP20 protection having Sound Control & Master Slave Auto Run Mode. Illuminate theIndoor stage with unlimited colour effects. As per direction of authority Including Labour cess and Insurance. |
| 1599 | Supplying and erecting Supplying and erecting SITC of 54x3W LED 3200K Par Light Beam Angle 25° complete with 3200K 3W Lamp source x 54 PcsHaving CRI TLCI Values above 95 Flicker Free for high FPSSmooth fade in and Fade outHigh precision steady colorNo heatDmX 512 dimming with 2 Channel0 ~ 100%Powder coatedBlack finish housingIP20 protection.As per direction of authority Including Labour cess and Insurance. |
| 1600 | Supplying and erecting Supplying and erecting SITC of Light fixture mouting clamp customized for suspending on fixed bars on stage made up of Aluminium or MS material complete with black powder coating matt black finish. As per direction of authority Including Labour cess and Insurance. |
| 1601 | Supplying and erecting Supplying and erecting SITC of Light Fixture dual safety chain made up of GI wire rope bundled and twisted together having load bearing capacity above 200 Kgssleve on the rope.As per direction of authority Including Labour cess and Insurance. |
| 1602 | Supplying and erecting Supplying and erecting SITC of C Profile MS Hot rolled strips 3mm thick with extra U bend used either to create basic supports for various auditorium stage rigsduly powder coated with matt black texture finish paint. As per direction of authority Including Labour cess and Insurance. |
| 1603 | Supplying and erecting Supplying and erecting SITC of Suspender cum clamps designed as per site conidition made out of MS material of size 50x 50x 6mm with black powder coated finish and threaded rod of minimum 12mm suitable to hold Basic grid and light bar.As per direction of authority Including Labour cess and Insurance |
| 1604 | Supplying and erecting Supplying and erecting SITC of 15 Mtr FOH Fixed Lighting Bar Straight as per the design made out of 40NB 48 OD Mild steel pipe dual barreldual construction connected with MS Flat duly powder coated with matt black texture finish.As per direction of authority Including Labour cess and Insurance. |
| 1605 | Supplying and erecting Supplying and erecting SITC of Power Controller havingrack mount / wall mountseparate incomer control for Motor control panel supplyRYB Phase indicators internally wired using IS certified wires and cablesprovided with ivery connectors for the internal terminations and external outgoing connecting points custom built as per specification and project requirement. As per direction of authority Including Labour cess and Insurance. as per OEM |
| 1606 | Supplying and erecting Supplying and erecting SITC of High quality power junction box 4 way made up of MS Sheet metal fabricated housing black powder coatedfibre glands of suitable size fitted with Powercon or IEC connector Box 10A. As per direction of authority Including Labour cess and Insurance. |
| 1607 | Supplying and erecting Supplying and erecting SITC of High quality Dimming In junction box 1 way made up of MS Sheet metal fabricated housing black powder coatedfibre glands of suitable size fitted with 5 Pin DmX XLR Female socket.As per direction of authority Including Labour cess and Insurance. |
| 1608 | Supplying and erecting Supplying and erecting SITC of High quality Dimming Out junction box 1 way made up of MS Sheet metal fabricated housing black powder coatedfibre glands of suitable size fitted with 5 Pin DmX XLR Male socket.As per direction of authority Including Labour cess and Insurance. |
| 1609 | Supplying and erecting Supplying and erecting SITC of Internal Earthing System with copper bare conductors all along the cable traysmetal parts and Installation Hardwares. As per direction of authority Including Labour cess and Insurance. |
| 1610 | Supplying and erecting Supplying and erecting SITC of Black Powder coated cable trays made out of MS Sheet fabricated fora size of 75mm with perforation for heat dessipation provided with lid.As per direction of authority Including Labour cess and Insurance. |
| 1611 | Supplying and erecting Supplying and erecting SITC of Motor Control Panel cum remote control 4 Way providing power input for curtain motors internally neatly wired with contactors having individual motor control with required Push buttonEmergency tripRYB indicatorsSupply Indictor and necessary meters. Motor control panel duly powder coated with ash grey paint texture finish with all required safety features. As per direction of authority Including Labour cess and Insurance. |
| 1612 | Supplying and erecting Supplying and erecting SITC of Cable Connecting Circuit Boxes for the termination of cables from Electrical panel to the grid level point made out of MS Sheet metal fabricated housing duly powder coated with matt black texture finish paintfitted with required channels and ivery connectorsnecessary glands etc.. As per direction of authority Including Labour cess and Insurance. |
| 1613 | Supplying and erecting Supplying and erecting SITC of DmX Male Female Connectors 5 Pin having rubber sheeth protection for Cross connecting DmX wiring connections. As per direction of authority Including Labour cess and Insurance. |
| 1614 | Supplying and erecting Supplying and erecting SITC of DmX Male Termination Connector 5 Pin soldered with required capacity of resistor for signal deframing. As per direction of authority Including Labour cess and Insurance. |
| 1615 | Supplying and erecting Supplying and erecting SITC of Opto isolated RDM enabled DmX splitter unit complete with Power In and safety fuse8 Output channels 5 Pin XLR in and out supporting DMX operation as per DmX 512 protocol. As per direction of authority Including Labour cess and Insurance. |
| 1616 | Supplying and erecting Supplying and erecting SITC of DmX Controller 24 Faders to control atleast 96 channels with master control faderscene saving optionLCD displaysmooth movement faderseasy access key padsDmX 512 protocoloptional chase & multifunction keys. As per direction of authority Including Labour cess and Insurance. |
| 1617 | Supplying and erecting Supplying and erecting SITC of FRLS Copper unarmoured Flexible cable having 7 Core each of 1.5 Sq mm size.As per direction of authority Including Labour cess and Insurance. |
| 1618 | Supplying and erecting Supplying and erecting SITC of 5 Core DmX Cable with Sheathed housing on the cablewell designed insulationlow noise suitable to transmet DmX signal.As per direction of authority Including Labour cess and Insurance. |
| 1619 | Supplying and erecting Supplying and erecting Supply installation and commissioning ofLaser Projector 5000 lumens WXGA : size of effective display area- 0.76” (19.3 mm) x 3 BrightEra LCD PanelAspect ratio: 16:10Number of pixels- 3 072 000 (1280 x 800 x 3) pixelsZoom – Ratio: Approx. x 1.45Throw ratio- 1.28:1 to 1.88:1Lens shift Range Vertical +20% to +55%Lens shiftRange Horizontal - +/- 10%Light source Type- Laser diodeFilter cleaning / replacement cycle (Max.)- 20 000 H Screen size- Screen size- 40\" to 300\" (1.02 m to 7.62 m)Light output- 5 000 lmContrast ratio - 500 000:1Speaker- 16 W Display resolution- 1920 x 1200 dots Video signal input- NTSCPALSECAM480/60p576/50i720/60p720/50p1080/60i1080/50i The following items are available for HDMI input only; 1080/60p1080/50p1080/24pKeystone correction Horizontal- +/- 30 degreesVertical- +/- 20 degreesINPUT OUTPUT -RGB / Y PB PR input connector:Mini D-sub 15 pin Audio input connector: Stereo mini jackINPUT B- HDMI input connector: HDMI 19-pinHDCP supportAudio input connector: HDMI audio support INPUT C-HDMI input connector: HDMI 19-pinHDCP supportAudio input connector: HDMI audio supportINPUT D- HDBaseT interface connector: RJ454 play (VideoAudioLANControl)VIDEO IN- Video input connector: BNCAudio input connector: Shared with INPUT AOUTPUT- Audio output connector: Stereo mini jackLAN- RJ45100BASE-TX USB- TYPE-ATYPE-B |
| 1620 | Supplying and erecting Supplying and erecting Supplying erecting of Projector Ceiling / Wall mounting kit |
| 1621 | Supplying and erecting Supplying and erecting Supply of imported motorised projector screen electrically operated 220 V AC50Hz single phase. Motor mounted in side roller tube 3-wire instantly reversible type with brake. Equipped with internal thermal overload projection. Preset limit switch setting automatically stops the screen in UP and DOWN position. 3 position control switch or radio-remote control stops orreverses screen direction at any point in the operating cycle. Robust square or hexagonal case in powder coated metal casing. Wall or ceiling mounted. Size 6 x8 Ft./8x10 ft |
| 1622 | Supplying, erecting, testing and commissioning ofSupplying, erecting, testing and commissioning ofDVI to HDMI Convertor high-speed category,supporting full HD 1080p, 2K and 4K video up to 30 ft length, 3D having 24k gold-plated 19-pin Type-A connectors with high-flex CL3-rated jacket, RoHS compliant complete. |
| 1623 | Supplying and erecting Supplying and erecting 3m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 1624 | Supplying and erecting Supplying and erecting HDMI ExtenderOver RJ45 Ethernet Cable Cat 660m/200ft complete. |
| 1625 | Supplying and erecting Supplying and erecting 15m Audio Video cord low voltage grade as per specificationwith required 3RCA x 3RCA connector complete. |
| 1626 | Supplying and erecting Supplying and erecting modular pop up Box 8 module erected with providedAV/ HDMI , RJ 45,6 A electricalsockets and switch on provided table. |
| 1627 | Supplying and erecting Supplying and erecting PVCtrunking (PVCcasing-n-capping)ofsize40 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. |
| 1628 | Supplying and erecting Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. |
| 1629 | Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose). [16-3-7] |
| 1630 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofETC solar water heating system without heat exchanger type of 500 LPD capacity with SS water tank of 0.5 mm thickness conforming to IS1239 Part-I :2004 complete as per specification no. ESD-SHWS-ETC |
| 1631 | Supplying and erecting Supplying and erecting 20/25 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 2.6 mm conforming to IS 15778 (CTS Series)with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC |
| 1632 | Supplying and erecting Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC),thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC |
| 1633 | Supplying and erecting Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves forcoating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system. |
| 1634 | Supplying and erecting Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves forcoating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 42 mm for solar water heater/AC system. |
| 1635 | Supplying and erecting Supplying and erecting ISI mark GI pipe 40 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. |
| 1636 | Supplying and erecting Supplying and erecting non return valve 40 mm dia in position made of gun metal complete. |
| 1637 | Supplying and erecting Supplying and erecting 40 mm. dia. gun metal sluice valve at position with necessary materials complete. |
| 1638 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofMonoblock Heat pump, having dimension: 995 x 785 x 1700 (mm), Input power: 2.22 kW, 400 V, 3 Ph, 50 Hz, Output power: 8 kW having hot water temperature range 35°C to 75°C and ambient temperature range for max. efficiency 7°C to 43°C, with glass lining hot water tank of 455 ltr. and min. 220 Kg at rated pressure 10 bar with two emergency heating elements operated on three operational mode: Efficiency mode,Hybrid turbo mode and Standard mode with Adaptive Energy System (AES), LED display with necessary accessories complete with 5 years ON-SITE warranty. |
| 1639 | Supplying and erecting Supplying and erecting Pressure Booster Pump, single phase, 50C/s, A.C. supply of 0.75 KW/ 1 H.P., With discharge of 480 to 13 LPM for 10 to 50 Mtr Head &25 mm suction/ 25 mm delivery pipe,for Domestic Pressure boosting applications. |
| 1640 | Supplying and erecting Supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160-270 V and output voltage 200-250V rated for 5kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16A plug top with overload & short circuit protection complete . |
| 1641 | Supplying and erecting Supplying and erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 1642 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning ofstorage type Mild Steel mixing water tank of capacity 3000 ltrs. tested to a pressure of 8 kg/cm2, insulated with 50 mm thick rock wool with wire mesh around and cladded with 26 SWG aluminium of dish end type with working pressure of 6 kg/cm2, fabricated with 6 mm thick MS plate and dished ends with 8 mm thick plates complete with man hole cover, inner side of the tank coated with FRP coating of 3 mm thickness withstand temperature of 90°C provided with collars of 2\" BSP forprovision toinstall6 numbers of electrical heating coils if required with thermal sensors for automatic operation and integrated into the electrical circuits of the circulation pumps and the heat pump with safety valve drain, inlet and outlet nozzle, pressure gauge with all necessary accessories complete. |
| 1643 | Providing and fixing Providing and fixing high-density polyethylene(HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacityup to 20000 litres. |
| 1644 | Supplying and erecting Supplying and erecting chromium plated heavy duty brass stop cock for inlet pipe of water heater (15mm. dia). |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail