Tender For Balance Electrical Works Including Supply Of Materials, Field Engineering, Installation/Erection, Third Party Inspection, Testing And Commissioning Of All Electrical Items And Allied Works For Bca Project At Lpg Bottling Plant, Budge Budge, parganas-West Bengal

Indian Oil Corporation Limited-IOCL has published Tender For Balance Electrical Works Including Supply Of Materials, Field Engineering, Installation/Erection, Third Party Inspection, Testing And Commissioning Of All Electrical Items And Allied Works For Bca Project At Lpg Bottling Plant, Budge Budge. Submission Date for this Tender is 14-10-2023. Electrical Maintenance Tenders in parganas West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

39872741
Tender For Balance Electrical Works Including Supply Of Materials, Field Engineering, Installation/Erection, Third Party Inspection, Testing And Commissioning Of All Electrical Items And Allied Works For Bca Project At Lpg Bottling Plant, Budge Budge
Open Tender
Indian
West Bengal
parganas
14-10-2023

Tender Details

Balance Electrical Works Including Supply Of Materials, Field Engineering, Installation/Erection, Third Party Inspection, Testing And Commissioning Of All Electrical Items And Allied Works For Bca Project At Lpg Bottling Plant, Budge Budge.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Balance Electrical Works including supply of materials, field engineering, installation/erection, third party inspection, testing & commissioning of all electrical items & allied works for BCA Project at LPG Bottling Plant, Budge Budge.
Sl. No. Item Description
1Proper Installation & commissioning in New PMCC Room using adequate size foundation bolts in guidence of L&T including fixing of Bus Bars Fish Plates, control circuit interconnections in between verticles etc. of L&T make PMCC Panel, 415 V, 50 KA for 1 Sec, IP-54, 2mm thick, powder coated, double front type with 2 Nos. Incomer and 1 no. bus-coupler feeder comprising drawout ACB with Electrical& Manual closing, having Undervoltage relay, Overcurrent & Short circuit protection, Earth Fault relay, Shunt trip coil & Auxillary contacts (2NO+2NC) for necessary interface, one from transformer secondary and one from DG Set (Change over Panel) with Interlock facility and outgoing drawout motor as well as power feeders for various new loads includingpumps/motors & Lighting facility etc. complete with all accessories, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD no. C396-E-SLD-101B, Rev-0 under guidance of L&T. (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item )
2Proper Installation & commissioning in New PMCC Room using adequate size foundation bolts in guidence of L&T including fixing of Bus Bars Fish Plates, control circuit interconnections in between verticles etc. of L&T make LDB Panel, 415 V, 10 KA for 1 Sec, IP-54, 2 mm thick, powder coated, single/double front type with two incomers of 400 A, 4-pole MCCB each with Overcurrent, Short circuit & Earth Fault protection, Shunt trip coil & Auxillary contacts (2NO+2NC) for necessary interface and outgoing non drawout Fuse-switch dis-connectors for Lighting of new facilities and emergency loads of the plants (covered under the augmentation plan) complete with all accessories, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD no. C396-E-SLD-101C, Rev-0. (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item )
3Proper Installation with all necessary hardwares in New PMCC Room using adequate size foundation bolts in guidence of L&T including fixing of Bus Bars Fish Plates, control circuit interconnections in between verticles etc. of L&T make APFC Panel 415 V,TPN, IP-54, 375 KVAR, 2mm thick, powder coated, with detuned filter consisting of 2x100kVAr + 2x50kVAr + 2x25kVAr + 1x15kVAr + 1x10kVAr (Total KVAr Rating = 375 KVAr) in step with automatic correction of Power Factorto maintain the terminal power factor of 0.95 and each step with contactor based step control as necessary. Incomer shall be draw-out type ACB (Min 630A) with single front type indoorwith operating mechanism, all accessories, auxiliariesetc. complete in all respects as specified in technical specification, data sheet & SLD no. C396-E-SLD-101D, Rev-0 & commissioning. (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item )
4Installation & commissioning of 110V D.C.75AH Ni-Cd Battery for 1 Hr. battery back-up, along with associated Float and Float-cum-Boost Charger Panel with protections & indications, DCDB with 125A DP Incomer and nine (9) nos. 32A DP switch fuse unitsand standard accessorie as perenclosed technical specification and Drg. no.C396-E-SLD-101F, Rev-0. along with all necessary strcturals, hardware etc. and as per direction of site engineer. (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item )
5Installation of Flame Proof Push Button Station including structurals , harwares & grouting on floor/coloumns/walls for control of motors for lighting supply, Aluminium LM6, IP65, Stainless Steel with indicating lamp for ON/TRIP with ON/Emergency Stop Push butttons with padlocking arrangement with spare aux. contact (1NO+1NC) for control interface with associated Structural support/mounting arrangement. (Suitable for Zone-1, IIC and T3, Make: Baliga /FCG Flameproof Control Gears/Flexpro As per direction of Site Engineer.
6Installation as above but with indicating lamp for FORWARD/REVERSE/TRIP and with FORWARD/REVERSE/Emergency Stop Push butttons.As per direction of Site Engineer.
7Installation of Flameproof MCBDB 240 V, 10 KA for 1 Sec, FLP,IP-65, Aluminium, LM6, with 32 A DP RCCB as incomer, and 9 Nos. of 10A DP MCBwith indication lamps with all accessoriesincluding structurals , harwares & grouting on floor/coloumns/walls suitable for wall mounting for emergency lighting or small power distribution(Suitable for Zone-1, IIC and T3, Make: Baliga /FCG Flameproof Control Gears/Flexpro) . As per direction of Site Engineer. (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item )
8Installation of Flameproof Phase Splitter Board (Junction Box) FLP,IP-65, Aluminium, LM6, with terminals and cable entries suitable for 1-run, 3.5-core 35 mm2 cable as incomer (TPN) and twelve (12) nos. 3-core cable 2.5 mm2 cable as outgoing (SPN) for lighting, with all accessories including structurals , harwares & grouting on floor/coloumns/walls (Suitable for Zone-1, IIC and T3, Make: Baliga /FCG Flameproof Control Gears/Flexpro) . As per direction of Site Engineer. (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item )
9Installation of Flameproof 415V, 63A three phase plug and socket meant for welding receptacle / any other three phase auxiliary loads shall be provided with 5 pins (3P + N + E), and TPN heavy duty switch, complete with all accessories suitable for column mounting (Suitable for Zone-1, IIC and T3, Make: Baliga /FCG Flameproof Control Gears/Flexpro) . (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item )
10Installation of Flameproof 240V, 16A single phase plug and socket meant for convenience receptacle / any other single phase auxiliary loads shall be provided with 3 pins (P + N + E), and SPN heavy duty switch, complete with all accessories suitable for column mounting (Suitable for Zone-1, IIC and T3, Make: Baliga /FCG Flameproof Control Gears/Flexpro) . (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item )
11Supply & Fixing of Plugs for flameproof equipment 1/2" ET plugs for flameproof equipment
12Supply & Fixing of Plugs for flameproof equipment 1" ET plugs for flameproof equipment
13INDOOR LIGHTING For License Area Installation of FLP lighting fixtures complete with mounting bracket/arrangement, flame proof, Wire Guard, Control Gear Box as per the type of fixture, lamps, interconnecting cables with terminals for 2 Nos incoming & Outgoing, FLP DC glands, lugs etc. including pipe inserts for cables and connecting work as per specifications, drawings and instruction of Engineer-in-charge.Work to be completed in all respects.
14Installation of Flame proof Well Glass type fixture, Aluminium, LM6, with 36W LED lamp andintegral LED Driver for New LPG Bottling Sheds with all necessary structural as may be required (Suitable for Zone-1, IIC and T3,Make: Baliga /FCG Flameproof Control Gears/Flexpro) (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item )
15Installation of Flame proof Well Glass type fixture, Aluminium, LM6, with 50W LED lamp integral LED Driver for New LPG Bottling Shedswith all necessary structural as may be required(Suitable for Zone-1, IIC and T3, Make: Baliga /FCG Flameproof Control Gears/Flexpro) (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item )
16Supply & Installation of Flame proof non integral floodlight fittings, Aluminium, LM6, suitable for 250W LED for peripheral lighting of New LPG Bottling Shedswith all necessary structural as may be required (Suitable for Zone-1, IIC and T3, Make: Baliga /Stahl/Flexpro) (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item )
17INDOOR LIGHTING For Safe Areas Supply & Installation of industrial type lighting fixtures and socket outlets complete with mounting rods, brackets, hangers, lamps, controlgear as required, circular JB, interconnecting wire & flexible conduit for interconnection from JB to fixture etc.
18Industrial type, heavy duty socket outlet - 415V, 63A, TPN+E with built-in MCCB/Isolator, of approved make and type.
19Industrial type, heavy duty socket outlet - 240V, 16A, SPN+E with built-in MCB/switch, of approved make and type.
20Installation ofwith necessary structurals, foundations etc. of FLP (Flame Proof) Out door Type Field Call Stations, Aluminium LM6, IP65, Stainless Steel, complete with all accessories, suitable for wall/column mounting. This shall beused for internal communication between plant personnel compatible with any type of existing EAPBX System, including supply of suitable communication cable and other acceessories, as required.(Suit able for Zone-1, IIC and T3, Baliga make or equivalent from approved vendor list) (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item )
21Installation of Supplied weatherproof/flameproof type fuse distribution boards, each housing one (1) no. 63A TPN isolator with twelve (12) nos. of 10A SPN fuses (with neutral link)with all necessary structural as may be required for connection up to individual flood light fittings, complete with all accessories, FLP D/C cable glands etc. as required..
22Power and Control Cables & Accessories Design, manufacture, shop testing, supply includingpacking and forwarding, transportation, delivery at site, storage, transportation from storage to site of Power and Control Cables & Accessories of following types and sizes : (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item ) 11KV (UE) Grade - Type : A2XFY
23Supply of 11kV (UE) A2FY 3 Core Cable
24Laying of 11kV(UE) 3-core 240 sq. mm.
25Heat shrinkable / push ON cable termination kit of RAYCHEM / MAHINDRA / CCI make for above - indoor type
26Heat shrinkable / push ON cable termination kit of RAYCHEM / MAHINDRA / CCI make for above - outdoor type
27ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items.
284-core 6 sq. mm.Stranded Copper Armoured FRLS Cable
293 Core x 2.5 sq. mm Stranded Copper Cable FRLS
304 Core x 2.5 sq. mm Stranded Copper Cable FRLS
316 Core x 2.5 sq. mm StrandedCopper Cable FRLS
323.5 Core x 95Sq. mm AluminiumCable FRLS
333.5 Core x 120Sq. mm AluminiumCable FRLS
34Laying of 1100V Grade - Type : A2XFY/A2XWY IOC supplied cables
353.5-core 240 sq. mm.
363.5-core 185 sq. mm.
373-core 120 sq. mm.
383.5-core 95 sq. mm.
393.5-core 35 sq. mm.
404-core 16 sq. mm.
413-core 16 sq. mm.
42Laying of 1100V Grade - Type : 2XFY/2XWY IOC supplied cables
433-core 2.5 sq. mm.
444-core 2.5 sq. mm.
455-core 2.5 sq. mm.
467-core 2.5 sq. mm.
4712-core 2.5 sq. mm.
484-core 6 sq. mm.
492-core 10 sq. mm.
50CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressioncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
51Suitable for 1100V Grade cables, Type : A2XFY/A2XWY/2XWY/2XFY
523.5-core 240 sq. mm.
533.5-core 185 sq. mm.
543-core 120 sq. mm.
553.5-core 95 sq. mm.
563.5-core 35 sq. mm.
574-core 16 sq. mm.
583-core 16 sq. mm.
59Suitable for 1100V Grade cables, Type : 2XFY/2XWY
603-core 2.5 sq. mm.
614-core 2.5 sq. mm.
625-core 2.5 sq. mm.
637-core 2.5 sq. mm.
6412-core 2.5 sq. mm.
654-core 6 sq. mm.
662-core 10 sq. mm.
67FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
683-core 120 sq. mm.
693.5-core 95 sq. mm.
703.5-core 35 sq. mm.
714-core 16 sq. mm.
723-core 16 sq. mm.
73Suitable for 1100V Grade cables, Type : 2XFY/2XWY
743-core 2.5 sq. mm.
754-core 2.5 sq. mm.
765-core 2.5 sq. mm.
777-core 2.5 sq. mm.
7812-core 2.5 sq. mm.
794-core 6 sq. mm.
802-core 10 sq. mm.
81Grid Earth Pits (For Max 1 ohm resistance)- GI Medium duty Pipe Electrode with min 5mm thick chequered plate cover with details as per IS 3043 with associated civil work- 100dia Heavy GI Pipe as per IS 1239 with detail as per enclosed drawing with TS
82Earth plates 600X600X6 mm. thk. Gl. Plate, complete with bolts, nuts and washers for equipment earthing connections
83Neutral Earth Pits(For Max 1 ohm resistance) - Plate Electrode with min 5mm thick chequered plate cover with details as per IS 3043 with associated civil work- 610x610x3mm. Size copper plate having weight of 9.84 kg and 1 no. 25x5mm copper strip (3.2M long and 1 no. 6 sq. mm. PVC insulated stranded copper wire (4 Mtr. long) and 50mm. dia heavy GI Pipe as per IS 1239 with detail as per specification/approved drawing
84Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following :
85Plant grid earth GI strip(50 x 6 mm.) with required standard saddle/support strips etc.
86Horizontal/vertical air termination for lightning protection of Shed - GI strip(32 x 6 mm.) with required standard saddle/support strips, fastners etc.
87Supply & fixing of Earthing conductor for earthing of equipment (with required lugs/connectors) :
8825 x 6 mm. GI strip
89150 sq mm PVC covered Al. cond.
9025 sq mm PVC covered Al. cond.
9116 sq mm PVC covered Al. cond.
926 sq mm PVC covered Al. cond.
932.5 sqmm PVC covered Cu Cond.
9416 SWG GI Wire (Twisted pair)
95Point Wiring Indoor Lighting Supply of point wiring materials for LT Panel Room or new HV Switchgear Room, as per details in construction drawing & specification, suitable for concealed wiring or thru" PVC casing and caping method (including supply of materials with cleats on surface) - for luminaries, sockets, lamps, industrial type heavy duty exhaust fans, ceiling fans with down rod / connector, electronic speed regulator, junction box, switch boxes & switches (ANCHOR ROMA make or equivalent) with Multi strand Flexible FRLS PVC insulated copper conductor wires/cables of suitable size (2.5/4.0/6.0sq.mm) with earthing wires (1.5/2.5sq.mm), as required to suit site condition etc. as mentioned below: (Note: Please also refer technical specification and drawing for all required items /components/works for this SOR item )
96Light, fan points (avg. length : 16M).
97Power point for socket outlet (avg. length : 25M)
98Cable dressing and tagging of cables in installed Main Electrical Panel and Distribution Boardsin PMCC Room. The work includes disconnection of all cables from panel side, removing all cabes upto entry to the panel room, relaying the cables through cable tray, or cable trench or electrical conduit and termination of cables with proper size cable glands in panel side after tagging with cable tags for identification. Payment for cable tray, conduit, any civil works, cable glands to be paid seperately.
99Standard Electrical Shock hazard charts complete with frame and glass
100Metal First Aid Box/Medical Kit Box with Handle | Multi Shelves | Wall Mount | For House, Educational Institutes, Commercial Spaces
101Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket, stand etcWith Mfg. Test certificate.
102Fire buckets with round bottom duly filled with fine river sand, supplied with mounting stand (Fire Stone Fire Bucket Stand with 4 nos Bucket)
103Caution boards including supply of necessary clamps, bolts and other hardware.
104Insulating Mats SupplyofInsulating Mats (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.
10511 KV grade of 3 mm thick
106415V grade
107Supplying, fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and/or fix to steel/RCC columns, beams or any other structure members with MS suspenders, angles, channels, etc complete as per the direction of IndianOil
10850mm wide x 50 mm(2mm. Thick)
109100mm wide x 50 mm (2mm. Thick)
110150mm wide x 50mm (2mm. Thick)
111GI Pipes: Supply & laying of pipes of following types and sizes (incl. bends):-
11250 mm NB (Class B GI, as per IS 1239 : Part-1)
11380 mm NB (Class B GI, as per IS 1239 : Part-1)
114100 mm NB (Class B GI, as per IS 1239 : Part-1)
115Supply & filling of fine River Sand for cable trenches
116Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks
117Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH
118PCC 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
119Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
120Supplying and installing of GI cable route marker with 100mm x 100mm x5mm thick GI Plate with inscription thereon, bolted/welded to 35mm x 35mm x 6mm angle iron, 600mm long and fixing the same in ground as per drawing & direction of Indian Oil Job includes painting with one coat of red oxide & finishing paint
121Industrial Step Ladder: Supply of 8 feet industrial step ladder with platform and rubberised four legs, self-supporting. All the materials used shall be suitable for use in hazardous areas.