Tender For Set Of Four Nos Of Standard Calibration Gas Mixture For Dissolved Gas Analyzer With Regulator Nozzle Fine Control 0.5 Litres W/C Aluminium High Pressure Canister With Fine Control Needle Valve And Septum As Spares To Draw Sample Directly F
Tender Overview
Project Description
Supply Of Set Of Four Nos Of Standard Calibration Gas Mixture For Dissolved Gas Analyzer With Regulator Nozzle Fine Control 0.5 Litres W/C Aluminium High Pressure Canister With Fine Control Needle Valve And Septum As Spares To Draw Sample Directly From Canister Using Gc Syringe. Preparation Tolerance (Plus Or Minus 20 %) And Shelf Life 12 Months. Filling Pressure 20 Kg/Sq.Cm. Gas Composition Is As Follows: Item 1: Hydrogen 5 Ppm,, Methane 5 Ppm,, Ethylene 5 Ppm,, Ethane 5 Ppm, Acetylene 5 Ppm, Carbon Monoxide 25 Ppm, Carbon Dioxide 25 Ppm, Propane 500 Ppm & Propylene 500 Ppm; Nitrogen As Balance; Item 2: Hydrogen 500 Ppm, Methane 500 Ppm, Ethylene 500 Ppm, Ethane 500 Ppm, Acetylene 500 Ppm, Carbon Monoxide 5000 Ppm & Carbon Dioxide 5000 Ppm; Nitrogen As Balance. ; Item 3: Hydrogen 750 Ppm, Methane 750 Ppm, Ethylene 750 Ppm, Ethane 750 Ppm, Acetylene 750 Ppm, Carbon Monoxide 7500 Ppm & Carbon Dioxide 7500 Ppm; Nitrogen As Balance; Item 4: Hydrogen 1000 Ppm, Methane 1000 Ppm,. Ethylene 1000 Ppm, Ethane 1000 Ppm, Acetylene 1000 Ppm, Carbon Monoxide 12000 Ppm & Carbon Dioxide 12000 Ppm; Nitrogen As Balance.
BOQ
| Sl. No. | Item Description |
| 1 | Set Of Four Nos Of Standard Calibration Gas Mixture For Dissolved Gas Analyzer With Regulator Nozzle Fine Control 0.5 Litres W/C Aluminium High Pressure Canister With Fine Control Needle Valve And Septum As Spares To Draw Sample Directly From Canister Using Gc Syringe. Preparation Tolerance (Plus Or Minus 20 %) And Shelf Life 12 Months. Filling Pressure 20 Kg/Sq.Cm. |
| 2 | Set of Four Nos of Standard Calibration Gas Mixture for Dissolved Gas Analyzer with RegulatorNozzle Fine control 0.5 litres W/C Aluminium High Pressure Canister with Fine control needle valve and septumas spares to draw sample directly from canister using GC syringe. Preparation Tolerance (plus or minus 20 %)and shelf life 12 months. Filling pressure 20 kg/sq.cm. Gas composition is as follows: Item 1: Hydrogen 5 ppm,,Methane 5 ppm,, Ethylene 5 ppm,, Ethane 5 ppm, Acetylene 5 ppm, Carbon monoxide 25 ppm, Carbon dioxide25 ppm, Propane 500 ppm & Propylene 500 ppm; Nitrogen as balance; Item 2: Hydrogen 500 ppm, Methane 500ppm, Ethylene 500 ppm, Ethane 500 ppm, Acetylene 500 ppm, Carbon monoxide 5000 ppm & Carbon dioxide5000 ppm; Nitrogen as balance. ; Item 3: Hydrogen 750 ppm, Methane 750 ppm, Ethylene 750 ppm, Ethane 750ppm, Acetylene 750 ppm, Carbon monoxide 7500 ppm & Carbon dioxide 7500 ppm; Nitrogen as balance; Item 4:Hydrogen 1000 ppm, Methane 1000 ppm,. Ethylene 1000 ppm, Ethane 1000 ppm, Acetylene 1000 ppm, Carbonmonoxide 12000 ppm & Carbon dioxide 12000 ppm; Nitrogen as balance. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender