| 1 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 2 | 5/6 amps switch |
| 3 | 3 pin 5/6 amps socket |
| 4 | 15/16 A switch |
| 5 | 6 pin 15/16 A socket outlet |
| 6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 7 | Single pole |
| 8 | Replacement and fixing of following typeexhaust/ wall/ ceiling/ pedestal fans suitable for operation on 230V, 50 Hz single phase AC Supply i/c dismentaling/ refixing, minor civil works if reqd. making connections, testing and commissioning etc complete as reqd. (Make: Crompton/ Bajaj/ Almonard/ Havells/ Usha/Orient) |
| 9 | 400 mm sweep, 1350 rpm wall fan |
| 10 | 1200 ceiling Fan |
| 11 | Replacement/ fixing of 6 Amp 4 outlet power strip controlled by common switch with surge protection suitable for 230 Volts, 50 Hz Single phase AC supply having connecting lead, safety fuse etc. complete as reqd. (Make: Havells/ Anchor/ Philips) |
| 12 | Replacement/SITC of Energy Efficient Ultra modern bright 36 W, LED batten directly on surface having following specifications i/c dismantling of existing outlived/ faulty fitting, connections, testing etc. complete as required :a) Wattage : 36 Watt + 10%b) System lumens efficacy : Not less than 110 lumen per wattc) Driver efficiency : Not less than 85%d) THD : Not more than 10%e) CRI : Not less than 80f) LED Life : Not less than 50000 hours @ LM 70%g) Colour temperature : 5500 - 6500 K h) Operating voltage range : 160 Volt to 270 Volti) Installation type : Wall / Ceiling surface installationj) Material of construction for housing : Polyuminum die cast k) Internal surge protection : Not less than 2.5 kVl) Ingress protection (IP): Not less than 20. (Make: M/S Havells/Philips/Wipro) |
| 13 | Replacement/SITC of Energy Efficient Ultra modern bright 20W, 1200 mm Long LEDPolycarbonate tube light (Single Side Connection) having following specifications i/c dismantling of existing outlived/ faulty conventional tube lights from existing fitting etc. complete as required:a) Wattage : 20 Watt + 10%b) System lumens efficacy : Not less than 110 lumen per wattc) Driver efficiency : Not less than 85%d) THD : Not more than 10%e) CRI : Not less than 80f) LED Life : Not less than 50000 hours @ LM 70%g) Colour temperature : 5500 - 6500 K h) Operating voltage range : 160 Volt to 270 Volti) Installation type : Wall / Ceiling surface installationj) Material of construction for housing : Polyuminum die cast k) Internal surge protection : Not less than 2.5 kVl) Ingress protection (IP): Not less than 20. (Make: M/S Havells/Philips/Wipro) |
| 14 | Replacement/SITC of Energy Efficient Ultra modern 595mm x 595mm size LED luminaire having following specifications i/c dismantling of existing outlived/ faulty conventional luminairewith high brightness SMD LEDs, making suitable arrangement for installation etc. complete as reqd in all respect to the entire satisfaction of Engineer-in-charge:- a) Wattage : 36 Watt + 10%b) System lumens efficacy : Not less than 100 lumen per wattc) Driver efficiency : Not less than 85%d) THD : Not more than 10%e) CRI : Not less than 80 f) UGR : Less than 19%g) LED Life : Not less than 50000 hours @ LM 70%h) Colour temperature : 5500 - 6500 K i) Operating voltage range : 140 Volt to 270 Voltj) Installation type : Recess Ceiling installationK) Material of construction for housing : CRCA powder coated white after phosphochromate treatmentl) Material of construction for cover : Scratch resistant and polycarbonate diffuser / coverm) Electronic Driver : independent Isolated type (Constant current supply)n) Internal surge protection : Not less than 2.5 kVo) Ingress protection (IP) : Not less than 20(Make: M/S Havells/Philips/Wipro) |
| 15 | Replacement/Supplying, Installation, Testing & Commissioning of Energy Efficient Ultra modern LED street Light luminaire having the following specifications i/c dismantling of existing outlived/ faulty conventional luminaire etc. complete as reqd in all respect to the entire satisfaction of Engineer-in-charge:a) 45 Wattageb) System lumens efficacy : Not less than 110 lumen per wattc) Driver efficiency : Not less than 85%d) LED Life : Not less than 50000 hours @ LM 70%e) Colour temperature : 5500 - 6500 K fh) Operating voltage range: 160 Volt to 270 Voltf) Material of construction for housing: Aluminium die cast g) Material of construction for cover: Toughened and shatter proof in build lens.h) Electronic Driver: Integral type (Constant current supply)i) Internal surge protection : Not less than 10 kVj) Ingress protection (IP): Not less than 66. (Make: Phillips, Havells) |
| 16 | Supply of fallowing size of PVC insulated, PVC sheathed copper conductor armoured cable of 1.1KV Gradei/c making connections, testing etc complete as reqd. (ISI Make) |
| 17 | a) 3 x 1.5 Sq mm |
| 18 | b) 3 x 4 Sq mm |
| 19 | Supplying and fixing of weather proof PVC Pole box of size 200 mm X 250 mm X 100 mm deep (Nominal), including providing and fixing Din Rail, 01 No SPMCB,01 No 4 way Neutral link,01 No heavy duty MS clamp, fixed with the help of nut &Bolt washer, making connection etc. complete as reqd.(Make: M/S Sintex or similar superior Make) |
| 20 | ITC of existing 1.5/ 2.0 TR Split AC units at desired location, i/c fixing of refrigerant piping with insulation, drain pipe, flexible covering, power connections, testing, commissioning etc. complete as reqd. |
| 21 | 1.5/2.0 TR Split A.C. Units |
| 22 | Servicing offollowing capacity Window/ SplitAC/ water cooler Units including washing & cleaning of filters, complete unit i.e evaporator unit, condensor unit i/c oiling, greasingof motors, testing, commissioning etc. complete as reqd. |
| 23 | 1.5/2.0 TR Window/ Split A.C. Units & water cooler |
| 24 | Repairing & Testing of 1.5/2.0 TR Capacity Split AC Units, flushing the system, pressure testing with Nitrogen gas holding the pressure for 24 hours, vaccumising, removal ofleakage inIndoor unit & out door unit including supply & charging of refrigerant gas (R-22) and oiling, greasingof motors, testing commissioning etc. complete as reqd. |
| 25 | S/Fixing, pre-fabricated M S Frame made out of 35x35x5 mm thk M S angle stand for 1.5/ 2.0 TR Split AC condenser i/c 2 coats of paint, grouting/ fixing on floor etc. as required. |
| 26 | S/Fixing 20 mm dia PVC drain pipe in recess or on surface for drainage of split AC units i/c connections etc complete as reqd. |
| 27 | S/Fixing PVC flexible pipe to cover the refrigerant pipes and power cables in the existing wall/on surface/ M S Tray with saddles, screwsincluding S/F clamps etc. as required. |
| 28 | 50 mm Dia |
| 29 | S/Fixing of following size 1.1 KV Grade PVC insulated copper conductor flexible cable in the existing M.S. Tray/Surface/Wall including S/F saddles, screws, thimbles i/c making connections, testing etc. complete as required. |
| 30 | 3 Core 2.5 Sqmm |
| 31 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for AC Units system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : |
| 32 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 33 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 34 | Total |
| 35 | Less Credit for dismantled material obtained from all above items of Sub Head-II which will be the property of the Contractor. @ 3% (-) |
| 36 | Remarks:1.Manpower will be deployed by the agency at site to receive the complaints and for co-ordination for the work. For this, one mobile no. with whatsapp facility will be provided by the agency.2. Adequate inventory of material will be kept at site by the agency for prompt attending the complaint.3. Complaint received in Fore Noon will have to be attended by After Noon and complaints received in Afternoon will have to be attended by Forenoon of next day. Emergency complaints, if any, will have to be attended immediately at any time including odd hours.4. Penalty of Rs. 500/- per complaint per day will be imposed for non-compliance of the complaint. If at any stage, it is observed that the performance of agency is not adequate, work will be rescinded, and the agency will be debarred from doing any work for one year in Delhi region. The work will then be carried out at his risk and cost without serving any notice5.The Agency should quote amount keeping in view all Statutory requirements including minimum wages/ESI/EPF etc. |
| 37 | Note:-1. 1. The Agency has to submit police verification record & ID proof of each staff.2. The firm shall provide each staff with working cell phone.3. The staff may be deputed for duty as per instruction of concerned SDE (E)/JTO (E).4. Penalty shall be imposed in case of absence of any staff as per T & C of contract.5.The GST / other Input Tax Credit (ITC) taxes shall be quoted by the firm as applicable as per latest amendments of GST Rules.6.The contractor shall provide correct tariff heads & other details to enable BSNL claim Input Tax Credit.7.Bidder must mandatorily quote for all GST components (CGST, SGST, and IGST) as required.8.The bidder who submits the offer with concessional Goods and Service Tax (GST) shall submit the proof of applicable concessional GST. In case the Concessional GST is not creditable to BSNL it should be included in the price of the goods/services.9. The FF & packing amount quoted shall not be subject to change after bid evaluation /ordering on account of change of copper, lead base price, change in duties & taxes of item etc.13. Bidder must mandatorily mention HSN & SAC numbers.14. Evaluation of bids: - The evaluation and comparison of responsive bids shall be done on the basis of Net cost to BSNL on the prices of the goods & Services (i.e. complete work) offered along with all applicable Taxes, packing Forwarding Freight & Insurance charges etc. exclusive of GST.Declaration by Bidder1.We hereby declare that in quoting the above prices, we have taken into account the entire credit on inputs available under the GST Act introduced w.e.f. 1 July 2017 and further extended on more items till date.2. We hereby certify that HSN/SAC shown in column 17 are correct & credit of GST for the amount shown in column 14 above are admissible as per GST Laws.Name of bidder:Seal of Company: GST No./(s) |