Public Works Department-PWD has published Maintenance Of Electronic Installation And Fans Including Compound Lights, Routine Servicing Of Water Coolers And Air Conditioners And Vrv At Dseu Okhla-Ii, Campus, New Delhi-110020.. Submission Date for this Tender is 03-10-2023. Air Conditioner Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | SH:- I (Comprehensive Maintenance of 98 HP VRV/VRF System) Comprehensive Maintenance of 98 HP Carrier Make VRV/VRF Air Conditioning System with all associated items (Indoor, Outdoor & copper tubing etc.) of units installed at DSEU Okhla-II, Campus, New Delhi i/c attending day to day complaints from 9 AM to 5 PM & rectifying the defects, supplying & replacement of worn out parts complete as per terms & condition and direction of Engineer-in-charge. |
2 | SH:- II (Routine Maintenance of EI & Fans)Routine maintenance of EI & Fans, Light Points, fan points, exhaust fan points, call bell points, Light and power plug, distribution boards,LT Cubical panels, meter board, sub main wiring, circuit wiring and all type of electrical fittings, i/c compound/ Street light and pump sets, sub-station etc. at DSEU Campus Okhla-II on all working days including sunday and Holidays as per terms and conditions as specified and by providing following minimum staff:-(a) Wireman cum Operator - 02 Nos.(1 No. in Each Shift) (6:00 AM to 2.00 PM & 2:00 PM to 10:00 PM)(b) Khallasi - 01 No.(9.00 AM to 5.00 PM) |
3 | SH-III (Annual Comprehensive Maintenance of Air Conditioning Unit & RO Plant) Annual Semi comprehensive Maintenance of 06 Nos 50LPH capacity RO system connected with water coolerscleaning of all filters, repair/replacement of all electrical and electronic spare parts and one time replacement of consumables like particulate filter 20"" (2x10"") Sediment filter 20"(2x10"), pre carbon filter 20"" and Post carbon filter 20"(Except TFC Membrance), attending complaits within 24working hours with complete overhauling and servicing etc as reqd. (6 Nos. RO) |
4 | Supply and replacement of RO TFC membrance 75/80GPD i/c testing, commissioning etc. as reqd old dismanle retained by the contractor. |
5 | Supply and replacement of 20"Particulate/Sediment Filteri/c testing, commissioning etc as reqd old dismanle retained by the contractor. |
6 | Servicing of existing installed WTAC/STAC of 1.5 TR & 2.0 TR capacity AC and water coolers including cleaning of water tank, checking of unit, greasing, oiling etc. i/c chemical cleaning of condensing & cooling coil with high pressure pump and cleaning of tank of water cooler, changing the air filter, checked & tightening all electric connections, testing the machine etc. as reqd. |
7 | Supply & Charging R-22/410/407/ 32/134a gas in the existing WTAC/STAC of 1.5/2.0 TR unit and water coolersi/c pressure testing, flushing the system and Gas Charging complete as reqd. |
8 | Comprehensive maintenance of WTAC/STAC/ unit and water cooleri/c cleaning of water tank, attending day to day complaints from 9AM to 5PM and rectifying the defects, replacement of worn out parts such starting / running capacitor, starting relays, overload relays, thermostate as selector switches, sleeves, knobs, Front grills connectors etc. which required to be replace during comprehensive maintenance & monthly cleaning of filters etc. (Replacement of Compressor, condenser fan, blower, fan/blower motor, Coils, Gas charging etc. not covered under comprehensive maintenance) complete as per terms & condition and direction of Engineer-in-charge. (25 Nos.X 2 Months= 50 Nos.) |
9 | SH-IV (Supplying of following items to be used during day to day maintenance) |
10 | 6A, 32A, ratings, SP MCB, "C", curve, 10 KA braking capacity. |
11 | 63 A rating Double Pole MCB |
12 | 3 Pole MCCB, 250A, 35kA |
13 | 3 Pole MCCB, 150A, 16kA |
14 | 1.5 sq.mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
15 | 4.00 sq.mm ISI marked, FRLS PVC insulated, single core copper conductor cable. |
16 | 6.00 sq.mm ISI marked, FRLS PVC insulated, single core copper conductor cable. |
17 | S.P. 5/6A one way Modular switch ISI marked. |
18 | 3 Pin 5/6 A Modular Socket outlet ISI marked. |
19 | S.P. 15/16 A one way modular switch ISI marked. |
20 | 6 Pin 15/16A Modular Socket outlet ISI Marked. |
21 | Bell Push modular type. |
22 | Stepped type modular Fan regulator(2 module) |
23 | 2.5 MFD Capacitor |
24 | 1200 mm sweep ceiling fan |
25 | Exhaust Fan 300 mm sweep 900 rpm |
26 | Fresh Air fan 200mm |
27 | 400mm sweep wall mounted cabin fan. |
28 | Downlighter of 15-18 Watt LED Square/roundpanel, surface/recess type. |
29 | 2"x2" LED Fitting 36 watt, surface/recess type. |
30 | 1"x4" 36wat LED fitting |
31 | Credit for Dismantle: |
32 | Assorted Ceiling Fans / wall fan |
33 | Assorted Fresh air Fan |
34 | Assorted Exhaust fans |
35 | Assorted Switch /sockets/Regulators/Capcitor |
36 | Assorted all type indoor/outdoor fittings |
37 | Assorted MCB/MCCB |
38 | Assorted wire with insulation copper |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy