Military Engineer Services-MES has published Tender For Provn Of Arboriculture, Fountain And Connected Works For Hanger And Associated Labs Under Ge (P) (Af) Hasimara.. Submission Date for this Tender is 20-10-2023. Fountains Tenders in hasimara West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

39843847
Corrigendum : Tender For Provn Of Arboriculture, Fountain And Connected Works For Hanger And Associated Labs Under Ge (P) (Af) Hasimara.
Open Tender
Indian
West Bengal
hasimara
20-10-2023

Tender Details

Provn Of Arboriculture, Fountain And Connected Works For Hanger And Associated Labs Under Ge (P) (Af) Hasimara.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Oct-2023 Date_Corrigendum_1 Date 11-10-2023
2 03-Oct-2023 E_Tender_Corrigendum BOQ 11-10-2023
3 04-Oct-2023 CorrigendumForTenderDocs Other 11-10-2023
4 11-Oct-2023 Date Corrigendum Date 13-10-2023
5 13-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-10-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 105000.0 /-
Tender Value
INR 63.20 Lakhs /-

BOQ Items

Name of Work:PROVN OF ARBORICULTURE, FOUNTAIN AND CONNECTED WORKS FOR WORKS SERVICES FOR CONSTRUCTION OF HANGER AND ASSOCIATED LABSUNDER GE (P) (AF) HASIMARA.
Sl. No. Item Description
1Note 1:- (Applicable for all parts/items) : The biidders/contractors are advised to read tender documents & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading ofincorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
2B/R Portion
3Excavation over areas not exceeding, not exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
4Excavation in trenches not exc 1.5 m wide and not exc 1.50 m in depth for foundation etc for shafts, wells, cesspits, manholes, pier holes etc. N.exc 10 sqm on plan and n. exc 1.50m depth and getting out in soft/loose soil complete all as specified and directed.
5M&L for PCC 100mm thick Type D2 (1:4:8) using 40mm graded stone aggregate as in foundations filling and mass concrete complete all as specified and directed.
6M&L for hard core of broken stone or boulders of guage not exc 63mm deposited, spread & levelled in layers not exceeding 15cm thick watered and rammed to true surface complete all as specified and directed.
7M&L PCC 100mm thick Type B1 (1:2:4) using 20mm graded stone aggregate as in sub base complete all as specified and directed.
8M&L brick work with fly ash bricks, straight or curved on plan exc 6m mean radius , built in CM (1:6) complete all as specified and directed.
9M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) and mixing with WPC complete all as specified and directed.
10M&L for finishing of walls with acrylic smooth exterior paint (Camouflage pattern) of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
11M&L non skid ceramic tiles coloured 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors set and jointd in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6) with liquid WPC complete all as specified and directed.
12M&L glazed ceramic tiles coloured in vertical surfaces 350x 250x7mm/ 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed in CM (1:4) with using liquid WPC complete all as specified and directed.
13M&L vitrified ceramic tiles coloured 10mm thick (square/ rectangular) polished area of each tile exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6) complete all as specified and directed.
14M&L forPCC 100mm thick Type C-2 (1:3:6) using 40mm graded stone aggregate as in sub base complete all as specified and directed.
15M&L for chequered cement concrete tiles cast in rubber mould glossy finish of approved colour, general purpose double layer 25cm X 25cm X 22cm thick with mixure of white and grey cement slurry in floor including laying over 15mm thick bedding of CM (1:6) complete all as specified and directed.
16S&F 10mm thick PVC Plain sheet (Make:- Rajshree Plastiwood or equivalent) ceiling up to a height 5.0m above floor level over angular iron framing (1.20m X 1.20m) fixed with self tapping screws. PVC sheet should be fixed at the bottom of the angle iron frame complete all as specified and directed.
17S&F toughened glass walling 10mm thick using aluminium frameincluding joining cleats, glazing clips, rubber beading packing, anodised aluminium snap beading screw etc complete all as specified and directed.
18S&F powder coated aluminium top hang sliding door shutters with frame, aluminium sections weighing 0.55kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, 5.5mm thick glass sheet fixing with aluminium beading and locking arrangement complete all as specified and directed.
19S&F powder coated aluminium side hang openable door shutters with frame, aluminium sections weighing 0.55kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, 5.5mm thick glass sheet fixing with aluminium beading and locking arrangement complete all as specified and directed. Note: (a) Sliding type powder coated aluminium door 01 No. (b) Side hung type powder coated aluminium door 2 Nos.
20S&F partition wall with pre laminated particle board both side lamination walling 10mm thick aluminium fame including joining cleats, glazing clips, ruber beading packing, anodised aluminium snap beading screw etc complete all as specified and directed.
21S&F5.5 mm thick glass as in partition wall using aluminium fame including joining cleats, glazing clips, ruber beading packing, anodised aluminium snap beading screw etc complete all as specified and directed.
22S&F door closer aluminium (extruded section) body hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
23S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
24S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
25S&F butt hinges 100mm long, cast brass, with mild steel hinge pin, bright polished and fixed, type B-12 complete all as specified and directed.
26S&F Extruded aluminium alloy handles, fabricated type, anodised 150mm long, complete all as specified and directed.
27S&F Aluminium anodised, barrel tower bolts of extruded section 150mm long, complete all as specified and as directed
28S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
29M&L for preparation of newly painted steel and iron surface of any description over 10cm width or girth, not otherwise described and applying a coat of synthetic enamel paint over one coat of primer complete all as specified and directed.
30S&F pre-painted galvaume aluminium zink coating Gl based currugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ clading to wall , fixed with self tapping screws complete all as specified and directed.
31S&F pre-painted galvaume aluminium zink coating Gl based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ clading to wall , fixed with self tapping screws complete all as specified and directed.
32S&F 10mm thick PVC eaves board for roofing edge finishes fixing with screws on iron section complete all as specified and directed.
33Returning filling in trenches including spreading, levelling, watering, and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed.
34Removing excavated to a distance not exceeding 50m and deposoited where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed.
35M&L for ploughing of groundand levelling surfaces, depth exc 30cm but n exc 45cm including picking up pebbles/ gravels/ broken stone including making surfaces even and uniform and removal of debris from the side to a distance of 50m and fresh earth (agriculture soil) free from stone particles, any impurities as approved including spreading leveling as per desired gradient and cultivating the soil by mixing adequate quantity of cow dung manure and fertilizer dressing the area, preparation of slope for proper drainage of water, fine leveling and plantation of lawn grass Australian/ Korean grass with all requirement from actual date of completion for grass, watering and look after from insects and animals etc complete all as specified and directed. Note: One year maintenance of grass is to be provided by the contractor after completion of the work. Any defects/ damage occured by that period that should be rectified by the contractor at free of cost.
36M&L for tree plantation by digging the hole of size 45cm in square/round and minimum depth 45cm in any type roof soil and refilling with extra/ sandy soil mixed with with manure of quantity 200gm to each hole complete to the entire satisfaction of Engineer-in-Charge . The distance of each hole must be followed by the road norms or as directed by the Engineer-in-Charge. Electric and overhead line must be taken in to consideration before designing the holes and variety of trees to be planted such as ficus Black, Bottle Palm, Ashoka, Large Stomia Ticoma Varigae complete all as specified and as directed. Note: One year maintenance of trees is to be provided by the contractor after completion of the work. Any defects/ damage occured by that period that should be rectified by the contractor at free of cost.
37E/M Portion
38External Water Supply M&L for excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out as specified and directed.
39S&F ofGI Pipe (25 mm dia) complete all as specified and directed.
40S&F of ball valve (25 mm dia) (above ground) complete all as specified and directed.
41M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
42M&L for removing excavated material not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
43External Electric Supply S&FXLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. Mm complete all as specified and directed.
44M&L for excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
45M&L sand cushoning and spreading Spreading and levelling in layers not exc. 25 cm thick complete all as specified and directed.
46Supplying and laying reinforced precast concrete cable cover,Class LV,Type 2, flat, size 300mm x 180mm x 40mm complete all as specified and directed.
47M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
48M&L for removing excavated material not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
49S&F 415V, 35 KA, 4P, 40 Amp thermal magnetic based MCCBof following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. (Make:- Havells - Cat no. IHDA3BBF0040)
50Internal Electrification M & L for concealed point wiring with 1.5 sqmm (niminal area) FR-LSH PVC insulated and unsheathed 1100V grade multistranded copper conductor (medium grade) not less than 20 mm dia with all fittings and accessories suitable for one light/one fan/one call bell point controlled by one switch including unsheathed single core stranded copper conductor cable of size 1.5 sqmm as earth continuity conductor connected to common earth and earth dolly and to be terminated to metal flush boxes covered with cover plate and frame as per reqirement at site for mounting switches, socket, fan regulators etc. including testing on completion complete all as specified and directed. Note: 1. Metal flush box and cover plate shall be measured and paid separately. 2. Cutting chases, making good disturbed surface shall be including in quoted lump sum of schedule "A" part-I and nothing extra shall be paid on this account.
51All as per item No. 1 here-in-before but for 15 Amp switch socket combination point independent with 4 sqmm PVC insulated unsheathed single core multi stranded copper conductor cable 1100 volt grade including one 4 sqmm PVC insulated unsheathed stranded copper cable for earth continuity conductor complete all as specified and as directed.
52All as per item No. 1 here-in-before but for 5 Amp socket point, on independent board, complete all as specified and as directed.
53S& F Single pole and neutral enlosure with earth plug and socket, P+N+E 10A with one double pole MCB 10A complete all as specified and directed.
54S&F piano switch 1 way 6A,250 Volts complete all as specified and directed.
55S&F pianoswitch socket outlet 5 A, 2/3 pin , 230 Volts complete all as specified and directed.
56M&L for submain wiring with two runs of single core 4 sqmm (nominal area) PVC insulated unsheated multistranded copper conductor cable LT 1100 Volt grade, drawn through in and including PVC rigid conduit pipe of size 25 mm dia mediumgrade including earth continuity conductor using PVC insulated unsheated copper conductor cable of size4 sqmm(Nominal area) green in colour connected to common earth dolly complete all as specified and directed. (Note : Two runs of cable one run of earth continuity copper conductor cable and one run of PVC conduit shall be measured as one length)
57M&L for factory made sheet metalenclousure double door designed SPN 8 Way DB, fixed on wall complete with copper bus bar, neutral link, dinrail suitable for mountingMCB"S all complete all as specified and directed.
58S&F MCBs (C -Curve)SPN 32A , breaking capacity 10KAcomplete with cable connection with cable connection with copper lugs complete all as specified and directed. Make: Legrand cat No 408617 or equivalent make.
59S&F MCBs (C-curve) SP 6-to 32A, capacity completewith cable connection with copper lugs complete all as specified and directed.
60M&L for factory made sheet metal enclosure double door designed vertical TPN DB 4way DB, fixed on wall complete with copper bus bar, neutral link, dinrail suitable for mountaining MCCB as incomer and MCB SPN/SP/TPN as outgoing complete all as specified and as directed. Make:- Legrand cat No 50745 or equivalent from make list as specified in PS
61S&F LED light fitting 2 ft x 2 ft36 watt suitable for armstrong, ceiling suspended vector III abstract design - geometryically aligned can be arrange symmetrically or abstract seamless integration with ceiling, easy maintenamce,high system efficiency makes it a hassle fre choise for space not less than 120 Lm/w burning hrs not less than 25000 hrs complete all as specified and directed. Make:- Crompton cat No LCTLRF4-36-TL or equivlent make of Havells, Bajaj
62S&F LED light fitting 1 ft x 1 ft15 watt suitable for armstrong, ceiling suspendedproxima-s high performance low hight back lit downlighter not less than 100 Lm/w burning hrs not less than 25000 hrs complete all as specified and directed. Make:- Crompton cat No CDR-208-15-57-SL-NWH or equivlent make of Havells, Bajaj
63S&F of Earthing complete with galvanisedsteel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point complete all as specified and directed or indicated including testing on completion
64Supply, installation, testing and commissioning of Dandelion Fountain having SS Stick (45 nos), submersible under water light (6 nos), Power supply unit, Controllers, Submersible Pump, Electrical Panel, UPVC Pipe, Control Valves etc to complete all as specified and directed.