Tender For Spl Repair To Bldg No. P-95 (Or Md Accn) At Lebong Under Age(I) Darjeeling., Darjeeling-West Bengal

Military Engineer Services-MES has published Tender For Spl Repair To Bldg No. P-95 (Or Md Accn) At Lebong Under Age(I) Darjeeling.. Submission Date for this Tender is 02-11-2023. Building Work Tenders in Darjeeling West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

39843103
Corrigendum : Tender For Spl Repair To Bldg No. P-95 (Or Md Accn) At Lebong Under Age(I) Darjeeling.
Open Tender
Indian
West Bengal
Darjeeling
02-11-2023

Tender Details

Tender For Spl Repair To Bldg No. P-95 ( Or Md Accn ) At Lebong Under Age ( I ) Darjeeling.; 1 Dismantling Of Plain Or Corrugated Steel Sheeting, Any Gauge, Thickness, Including Nainital Or Similar Pattern Roof Coverings, Complete All As Specified And Directed. 2 S&F Of Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws All As Specified And Directed. 3 S&F Of Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws All As Specified And Directed. 4 Add To Item 2.00 & 3.00 Here-In-Before If Fixed With L-Type Or J-Type Or Cranked Hook Bolts In Lieu Of Screw, Complete All As Specified And Directed. 5 Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For, Complete All As Specified And Directed. 6 S&F Of Mild Steel Hand Rails, Half Round Or Other Steel Section Or Core For Wooden Hand-Rail Straight Portion, Drilled And Countersunk For Balusters Running Bars, For Doors, Balusters, Nosing To Steps Including Embeding Inconcrete And Screwing Etc. Wind Ties For Roof Including Securing Bolts Conforming To Fe-290 Gde E-165, Complete All As Specified And Directed 7 S&F Of Framed Brackets Of Angles Or Tees With Web And Flanges Cut To Shape, Drilled And Countersunk For Screw, Including Bending And Welding Angles, As Necessary, Gusset Plates, Riveting, Etc.. N Exc 10 Kg Each Brackets, Conforming To Fe.290.Gde-E-165 ( Brackets Over 10 Kg Each To Be Measured Under Structural Steel ) , Complete All As Specified And Directed. 8 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust, Etc., Complete All As Specified And Directed. 9 M&L For Screed Bed Or Bedding Layer Of Mortar 15 Mm Thick For Laying Floor Finishes In Cement Mortar ( 1:6 ) Finished Even And Rough, Complete All As Specified And Directed. 10 M&L For Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.18 Sqm But Not Exceeding 0.38 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Surface Of Tiles, Complete All As Specified And Directed. 11 M&L For Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Surface Of Tiles, Complete All As Specified And Directed. 12 M&L For Machine Cut Kota Stone Slab 20-25Mm Thickin Riser Of Steps, Skirting, Dado And Pillar Laid Over Cement Screed And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing, Complete All As Specified And Directed. 13 M&L For Chequered Cement Concrete Tiles 20Cm X 20Cm X 25Mm Thick, Set, Jointed And Pointed In Neat Cement Slurry In Floors With Grey Cement And No Pigments, Complete All As Specified And Directed. 14 M&L For Rendering 10Mm Thick In Cement Mortar ( 1:3 ) On Fair Faces Of Brick Work Or Concrete Surfaces, Complete All As Specified And Directed. 15 M&L For Coloured Glazed Ceramic Tiles In Vertical Surface 350X 250X 7 Mm / 450X 350X 7Mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match The Surface Of Tiles, Complete All As Specified And Directed. 16 Taking Down Cement Or Cement Lime Plaster, Any Description On Brick Or Stone Masonrysurfaces Of Walls Etc Includingrakingout Joints, Hackingfor Key, Scrubbingdown With Wateretc, Complete All As Specified And Directed. 17 M&L For Rendering 15Mm Thick In Cement Mortar ( 1:6 ) On Fair Faces Of Brick Work Or Concrete Surfaces, Finished Even And Smooth ( Without Using Extra Lime Or Cement ) , Complete All As Specified And Directed. 18 M&L For Rendering 15Mm Thick In Cement Mortar ( 1:4 ) With Water Proofing Compound @ 3% By Weight Of Cement Or In The Manner Specified By The Manufacturer And In The Proportions Indicated On Fair Faces Of Brick Work Or Concrete Surfaces, Finished Even And Smooth ( Without Using Extra Lime Or Cement ) , Complete All As Specified And Directed.Note: Water Proofing Compound Will Be Measured And Paid Separately. 19 M&L For 5Mm Thick Rendering In Cement Mortar ( 1:3 ) On Concrete Surfaces In Ceilings And Finished Even And Smooth ( Without Using Extra Lime Or Cement ) , Complete All As Specified And Directed. 20 Supply Only Integral Water Proofing Compond, All As Specified And As Directed. 21 M&L For Preparation Of New Plastered Or Unplastered Surface Of Wall And Applying Two Coats Of Distemper Oil Emulsion ( Obd ) , Over Acoat Of Priming Coat ( Chalk Whiting, On Plastered Surfaces, Prepara-Tory To Distempering ) Including 3Mm Thick Wall Care Putty On Wall, Complete All As Specified And Directed. 22 M&L Forpreparation Of New Plastered Or Unplastered Surface Of Ceiling And Applying One Coat Of Oil Bound Distemper ( Distemper Oil-Emulsion ) Over A Coat Of Priming Coat ( Chalk Whiting, On Plastered Surfaces, Preparatory To Distempering ) Including 1Mm Thick Wall Care Putty On Ceiling, Complete All As Specified And Directed. 23 M&L Forpreparation Of New Plastered Or Unplastered Surface Of Wall And Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) , Complete All As Specified And Directed. 24 M&L For Complete Removal Of Existing Treatment On Plastered Or Unplastered Surface Of Wall Including Brooming Down Or Steel Wire Brushing, Scrapping Down Smoke Scoot, Mould, Moss And Efflorescent Salt, Trading Oil And Greasy Spot And Applying One Coat 1Mm Thick Of Wall Care Putty And Then Applying Two Coats Of Distemper Oil Emulsion ( Obd ) , White Or Tinted Over A Coat Of Priming Coat ( Chalk Whiting, On Plastered Surfaces, Preparatory To Distempering ) After Preparation Of Wall Surfaces, Complete All As Specified And Directed. 25 M&L For Complete Removal Of Existing Treatment On Plastered Or Unplastered Surface Of Ceiling Including Brooming Down Or Steel Wire Brushing, Scrapping Down Smoke Scoot, Mould, Moss And Efflorescent Salt, Trading Oil And Greasy Spot And Applying One Coat Of Oil Bound Distemper ( Distemper Oil-Emulsion ) Over Acoat Of Priming Coat ( Chalk Whiting, On Plastered Surfaces, Preparatory To Distempering ) Including 1Mm Thick Layer Of Wall Care Putty On Ceiling After Preparation Of Wall Surfaces, Complete All As Specified And Directed. 26 M&L For Complete Removal Of Existing Treatment On Plastered Or Unplastered Surface Of Wall Including Brooming Down Or Steel Wire Brushing, Scrapping Down Smoke Scoot, Mould, Moss And Efflorescent Salt, Trading Oil And Greasy Spot And Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade ( Company Depot Tinted ) With Silicon Additives @ 1.43 Litre / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre / 10 Sqm Over New Surfaces, Complete All As Specified And Directed. 27 M&L For Preparation Of Old Decorated Plastered Or Unplastered Surfaces Of Wall Including Brooming Down Or Steel Wire Brushing, Scrapping Down Smoke Scoot, Mould, Moss And Efflorescent Salt, Trading Oil And Greasy Spot And Applying And Applying Two Coats Of White Wash On Walls, Complete All As Specified And Directed. 28 M&L For Preparation Of Old Wood Or Wood Based Surfaces Of Any Description Over 10 Cm Width Or Girth Not Otherwise Described And Applying Two Coats Of Synthetic Enamel Paint, Complete All As Specified And Directed. 29 M&L For Preparation Of New Wooden Or Wood Based Surfaces Of Any Description Over 10 Cm Width Or Girth Not Otherwise Described And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer, Complete All As Specified And Directed. 30 M&L For Preparation Of Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide, Zinc Chrome Primer, Complete All As Specified And Directed. 31 M&L For Preparation Of New Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide, Zinc Chrome Primer, Complete All As Specified And Directed. 32 Taking Up Or Downold 15 Mm Bore Steel Water Tubing And Connections, Including Cleaning For Refixing Or Removal To Store Or From Site, Complete All As Specified And Directed. 33 Taking Up Or Down Old 20 Mm Bore Steel Water Tubing And Connections, Including Cleaning For Refixing Or Removal To Store Or From Site, Complete All As Specified And Directed. 34 S&F Of 15 Mm Bore Steel Water Tubes, Medium Grade, Galvanised With And Including All Gi Fitting ( Such As Bends, Elbows, Tees, Connectors, Short Pieces, Back Nuts, Unions, Caps And Plug Etc ) And Fixed Complete To Wall And Ceilingor Laid In / On Floor, Complete All As Specified And Directed. 35 S&F Of 20 Mm Bore Steel Water Tubes, Medium Grade, Galvanised With And Including All Gi Fitting ( Such As Bends, Elbows, Tees, Connectors, Short Pieces, Back Nuts, Unions, Caps And Plug Etc ) And Fixed Complete To Wall And Ceilingor Laid In / On Floor, Complete All As Specified And Directed. 36 Refixing Old 15 Mm Bore Steel Tubing And Connections In New Or Old Position ( Walls, Ceiling, Floors, Etc. ) , Complete All As Specified And Directed. 37 Refixing Old 20 Mm Bore Steel Tubing And Connections In New Or Old Position ( Walls, Ceiling, Floors, Etc. ) , Complete All As Specified And Directed. 38 S&F Of 600Mmx450mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers, Complete All As Specified And Directed. 39 S&F In Repair Of 15Mm Bore Dia Bib Taps, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule And Fixed, Complete All As Specified And Directed. 40 S&F In Repairs Of 15Mm Bore Dia Stop Valves, Chromium Plated, Fancy Type, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed, Complete All As Specified And Directed. 41 S&F Of Water Closet ( Squatt Pattern ) Of Vitreous China Squatting Pan Of Pattern Orrisa Pattern Size 580 X 440 Mm White With Integral Foot Rests ( Excluding Flushing Cistern And Flush Pipe ) Including Connection To Trap And Flushing Pipe Anti Syphonic Pipe Etc Complete Including P Or S Trap Set In And Including Necessary Lean Cement Concrete, Complete All As Specified And Directed. 42 S&F Of Vitreous China Wash Down Water Closet Pan ( Pedestal Pattern ) , White ( Excluding Fixing Bolts, Flushing Cistern And Flush Pipe ) And Making Good The Floor, Complete All As Specified And Directed. 43 S&F Of 100Mm Bore Of Pipe ‘P’ Or ‘S’ Traps Without Vent Horn, Complete All As Specified And Directed. 44 S&F Of Pvclow Level Flushing Cistern 10 Litre Capacity, Valveless Syphonic Action Type Complete With Inlet, Ball Valve, Float Valve, Bends Brackets, Rawl Plug, Brass Screws Handle Etc Complete Having Bis Description Mark With Is:2731 With And Including Suitable Size Of Ms Brackets, Plug, Screw All As Required Incl Taking Down Existing High Level / Low Level Flushing Cistern Any Type Disconnecting Pipes And Jointing With New One Etc, And Making Good The Floors / Walls As Per Existing Floor Finish / Wall Finish Including 32 Mm Bore Pvc Flush Pipe And Jointing With Water Closet Of Any Type, Complete All As Specified And Directed. 45 S&F Of Pvc Connections 15Mm Size With Ptmt Nuts Of Length 450Mm, All As Specified And Directed. 46 S&F Of Towel Rail 450Mm Long Of Ptmt Fixed With And Including Chromium Plated Brass Screws And Wooden / Plastic Cleats ( Minimum Weight 170Gms ) , Complete All As Specified And Directed. 47 S&F Of Grating Doom 100Mm Dia Of Ptmt ( Minimum Weight 25Gms ) , Complete All As Specified And Directed. 48 S&F Of 1Mm Thick Stainless Steel Sink With Drainage Board Kitchen Or Laboratory Type With Waste Pipe, Plugs, Washers And Wastes, Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Over All Size Of Sink 915Mm X 460Mm And Bowl Size 410Mm X 330Mm X 160Mm, Complete All As Specified And Directed. 49 Dismantling Water Tanks Of Capacity Exc 500 And N Exc 1000 Litres And Removing To Store, Complete All As Specified And Directed. 50 S&F Of Rotational Moulded Polyethylene Water Storage Tanks Of Capacity 1000 Litres ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position All As Specified In Ssr Part-L And Directed. 51 S&F In Repairs Of 20 Mm Bore Dia Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & Highdensity Plastic Ball Screwed For Iron Pipe And Fixed. ( Minimum Weight 15Mm-142Gms / 20 Mm - 210 Gms. / 25Mm-455Gms / 40Mm - 690 Gms ) , Complete All As Specified And Directed. 52 Supplied And Fixed In Repair Of 15 Mm Bore Gun-Metal, Globe Or Gate Valves, With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixed, Complete All As Specified And Directed. 53 Supplied And Fixed In Repair Of 20 Mm Bore Gun-Metal, Globe Or Gate Valves, With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixed, Complete All As Specified And Directed. 54 Dismantling Of Wall And Ceiling Boards ( Fibre, Pulp, Insulation, Etc. ) Or Insulation Boards / Slabs / Blankets, Any Thickness, Including Cover Fillets, Complete All As Specified And Directed. 55 S&F Of Anodised Aluminium Snap Grid Frame Work Of Size Of Grid 605Mm X 605Mm For False Ceiling, Complete All As Specified And Directed. 56 M&L For 4Mm Thick Non Asbestos Fibre Cement Building Boards Fixed Or Laid / Inserted To Timber / Gi / Aluminium Framework With Screws In Ceiling Flat Or Sloping, Complete All As Specified And Directed. 57 Demolition And Breaking Up Drain Pipes ( Pvc ( Swr ) , Salt Glazed Ware, Ac Or Reinforced Concrete ) Of 150Mm Bore Including Accessories Set In Cement Mortar And Removing Rubbish From Site, Complete All As Specified And Directed. 58 Demolition And Breaking Up Drain Pipes ( Pvc ( Swr ) , Salt Glazed Ware, Ac Or Reinforced Concrete ) Of100mm Bore Including Accessories Set In Cement Mortar And Removing Rubbish From Site, Complete All As Specified And Directed. 59 M&L For 150Mm Internal Diameter Salt-Glazed Stoneware Drain Pipes Laid In Trenches And Jointed All As Specified And Directed. 60 M&L For 100Mm Internal Diameter Salt-Glazed Stoneware Drain Pipes Laid In Trenches And Jointed All As Specified And Directed. 61 M&L For Plain Cement Concrete ( 1:4:8 ) Bed, Type D-2, ( Using 40Mm Graded Stone Aggregate ) To Drain Pipes 150Mm Bore Including Packing Under, And Haunching Against The Sides Of Pipes After They Are Laid And Tested, Complete All As Specified And Directed. 62 M&L For Plain Cement Concrete ( 1:4:8 ) Bed, Type D-2, ( Using 40Mm Graded Stone Aggregate ) To Drain Pipes 100Mm Bore Including Packing Under, And Haunching Against The Sides Of Pipes After They Are Laid And Tested, Complete All As Specified And Directed. 63 Dismantling Of 100Mm Dia Cast Iron Or Reinforced Concrete Drain Pipes, Jointed In Cement Mortar And Taking Out Of Trenches, If Required, Complete All As Specified And Directed. 64 M&L For 100Mm Bore Cast Iron Soil, Waste And Vent Pipes In Any Length With Or Without Ears, With Cement Joints, Laid In Trenches Or In Floors, Complete All As Specified And Directed. 65 M&L For 100Mm Bore Cast Iron Soil, Waste And Vent Pipes In Any Length With Or Without Ears, With Cement Joints, Fixed To Walls, Complete All As Specified And Directed. 66 S&F Of 100Mm Bore Dia Cast Iron Bends ( Any Radius ) , Diminishing Pieces Or Tapers ( Larger Bore Measured ) Fitted With Oval Access Doors, Complete All As Specified And Directed. 67 S&F Of 100Mm Bore Dia Cast Iron Cowls, Complete All As Specified And Directed. 68 Demolition Of Cement Concrete ( Unreinforced ) In Ground Floor And Pavings Not Exc 15 Cm Thickness ( Below Or Above Ground Level ) , Complete All As Specified And Directed. 69 M&L For 75 Mm Thick Plain Cement Concrete ( 1:3:6 ) , Type C-2 ( 40 Mm Graded Stone Aggregate ) As In Plinth Protection, Hard Standing, Path Etc Including Finish The Surface Even And Smooth Without Using Extra Cement, Complete All As Specified And Directed. 70 M&L For 40Mm Thick Plain Cement Concrete ( 1:2:4 ) , Type B-1, ( Using 20Mm Graded Stone Aggregate ) As In Sub-Base, Sub-Floors, Floors, Pavings, Roof Treatment Etc., Complete All As Specified And Directed. 71 M&L For Hardcore Using Broken Stone Or Boulders Of Gauge N Exc. 63Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface, Complete All As Specified And Directed. 72 Demolition Of Brickwork Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, But Excluding Ashlar Facings, Dressed Stonework And Precast Concrete Articles, Complete All As Specified And Directed. 73 M&L For Brickwork With Fly Ash Bricks ( Old Size Bricks ) , Straight Or Curved On Plan Exc 6M Mean Radius, Built In Cement Mortar ( 1:6 ) , Complete All As Specified And Directed. 74 M&L For Plain Cement Concrete ( 1:3:6 ) , Type C-2 ( 40 Mm Graded Stone Aggregate ) In Surface Channels And Drains, Complete All As Specified And Directed. 75 M&L For Extra For Forming Fair Finished Drain Or Channel 30 Cm Inner Girth In Cement Concrete, Using Extra Cement Including Forms, Moulds Mitered / Stopped Ends Etc All As Specified And As Directed. 76 Taking Down Chowkhatsor Frame Not Exc 1.50 Sqm Each With Shutter ( Without Taking Off Shutters From The Frame ) , Complete All As Specified And Directed. 77 Taking Down Chowkhats Or Frames Exc 1.5 Sq. M But N Exc 4 Sq. M Each With Shutters ( Without Taking Off Shutters From The Frame ) , Complete All As Specified And Directed. 78 Taking Down Shutters Of Any Description N Exc 1 Sq. M Each, Complete All As Specified And Directed. 79 Taking Down Shutters Of Any Description Exc 1 Sq. M And N Exc 2 Sq. M Each, Complete All As Specified And Directed. 80 Dismantling Timber Scantlings 40 Sqcm And Over In Section, In Any Position ( Unframed Work ) , All As Specified And Directed. 81 S&F Of Second Class Hard Wood Plain, Solid, Straight Chowkats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue Pinned At Joints, Complete All As Specified And Directed. 82 M&L For Preparing Surfaces Of Wood And Wood Based Materials, New Or Old Of Any Description And Girth, Not Otherwise Described And Treated With One Coat Of Creosote Oil, Complete All As Specified And Directed. 83 M&L For Second Class Hard Wood, 35Mm Thick Plain, Framed, Panelled Shutters ( Any Number Of Panels ) , With Panels Of Timber Flat On Both Sides ( Feather Edged ) , Or Of Veneered Particle Board Medium Density, Wood Particle Board With Commercial Face Veneers: Supplied And Fitted To Chowkats, Complete All As Specified And Directed. 84 S&F Of 35 Mm Thick ( Batten Thickness ) Second Class Hard Wood, Glazed And Skelton Shutters, Open Rebated And Prepared To Receive Glass, Gauge, Etc , Divided Into Squares, With Plain Chamfered Or Rounded, Mitred And Rebated Sash Bars, Edges Of Framing Plain, Chamfered Or Rounded With Cut Mitred Beds For Securing Glass Etc, Supplied And Fitted To Chowkhats Completeall As Specified And Directed. ( Note :- The Dimension Of The Various Components Or Parts Of Shutters Shall Be As Specified In Clause 8.24 ( A ) Of Mes Ssr 2009 Part I ) 85 M&L For Second Class Hard Wood, 30Mm Thick Glazed And Skeleton Windows Shutters, Ventilators Shutters Etc. Are Provided With Stiles And Rails, Open Rebated And Prepared To Receive Glass, Gauze, Etc. Divided Into Squares, With Plain, Chamfered Or Rounded, Mitred And Rebated Sash Bars, Any Numbers Fitted With Cut And Mitred Beads For Securing Glass, Etc.; Sizes Of Members Of Shutters As Specified In Ssr Part I, Section 8 Clause 8.24 ( B ) ; Supplied And Fitted To Chowkats, Complete All As Specified And Directed. 86 S&F Of Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S. Square Tube, Suppling & Fixing In Opening As Per Specification & Drawing, Complete All As Specified And Directed. 87 S&F Of Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick ( Style ) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails. M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc ‘C’ Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing And As Directed. 88 S&F Of 100Mm Size Butt Hinges, Medium Weight, Cold Rolled Mild Steel, And Fixed, All As Specified And Directed. 89 S&F Of 75Mm Size Butt Hinges, Medium Weight, Cold Rolled Mild Steel, And Fixed, All As Specified And Directed. 90 S&F Of 125 Mm Size Aluminium Handles, Cast Type, Anodised, All As Specified And Directed. 91 S&F Of 100Mm Size Aluminium Handles, Cast Type, Anodised, All As Specified And Directed. 92 S&F Of 200Mm Long Aluminium Anodised, Barrel Tower Bolts Of Extruded Section And Fixed, All As Specified And Directed. 93 S&F Of 125Mm Long Mild Steel Barrel Tower Bolts, Stove Enamelled Black, With Bright Bolt And Fixed, All As Specified And Directed. 94 S&F Of 250 Mm Long Aluminium Alloy, Anodised, Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed, All As Specified And Directed. 95 Hacking Out Old Broken Glass, Exc 1.5 Sqm ( Any Thickness, Quality Or Description ) From Wooden Frames Or Stone, Concrete Or Brick Surrounds, Glazed With Putty Or Fixed With Beads, Complete All As Specified And Directed. 96 S&F Of 3.0Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square N Exc 0.5 Sq. M In Each Pane, Complete All As Specified And Directed. 97 S&F Of 3.0Mm Thick Sheet Glass Ground Or Obscured Or Frosted, On One Side, Ordinary Quality And Glazing With Oil Putty In Square N Exc 0.5 Sq. M In Each Pane, Complete All As Specified And Directed. 98 S&F In Repairs Galvanised Mild Steel Wire Cloth, 0.56Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18Mm And Fixed With Tinned Tacks, Or Galvanised Wire Staples, Complete All As Specified And Directed. 99 S&F Of Bands, Straps, Supports Or Stays For Rainwater, Ventilating Pipes, Including Bolts, If Required: Hooks ( Stay ) , Heavy, For Large Gates; Hook And Pintle Hinges: Large Hasps And Staples; Chains; Hand Made Sliding Bolts; Clamps; Hold Fasts; Wall Ties; Hooks For Hanging Fans; Plain Angle Cleats For Securing Purlins To Wood Trusses Or Rafters; Knee Piece Inserts; Two Way And Three Way Straps, Plate Washers And Similar Small Articles Conforming To Fe-290 Gde-E-165, Complete All As Specified And Directed. 100 M&L For Plain Cement Concrete ( 1:3:6 ) , Type C1 ( Using 20Mm Graded Crushed Stone Aggregate ) In Lintels Upto 1.5M Clear Span, Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating, Complete All As Specified And As Directed. 101 S&F In Repair Of Small Fittings Such As Brackets Of Any Type Latch And Hinge Block, Shaped Door Window Stops And The Like In Second Class Hard Wood Article Not Exc 200 Cucm Each, Complete All As Specified And Directed. 102 Taking Down Eaves Gutters And Rainwater Pipes ( Any Size Or Pattern ) , Including All Fittings, Heads, Shoes, Bends, Swan-Necks, Etc., Including Cleaning Or Refixing Or Removal To Store ( Measured Overall As Fixed Along The Centre Line Over Fittings And Accessories ) , Complete All As Specified And Directed. 103 S&F Of 110Mm Bore Pvc ( Swr ) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Walls, Complete All As Specified And Directed. 104 S&F Of 110Mm Bore Pvc ( Swr ) Bends Any Radius, Complete All As Specified And Directed. 105 Rough Excavation Not Exceeding 1.5 M Deep And Getting Out In Soft / Loose Soil, All As Specified And Directed. 106 Returning Filling In Soft / Loose Soil Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25Cm, Complete All As Specified And Directed. 107 Removal Of Surplus Excavated Soils To A Distance Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.50M Above The Starting Point, Complete All As Specified And Directed. 108 M&L For Plain Cement Concrete ( 1:2:4 ) , Type B-0 ( Using 12.5 Mm Graded Stone Aggregates ) In Coping, Bed Plates, Parepet, Plinth Course Including Weathering, Slightly Rounded Or Chamfered Angles And Throating, Complete All As Specified And Directed. 109 Demolition Ofreinforced Cement Concrete ( Reinforcement Cut As Required To Facilitate Demolition ) Of Any Description And In Any Position Not Specifically Provided For, Complete All As Specified Andas Directed. 110 Use And Waste Of Formwork To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions For Rough Finished Surfaces Of Concrete On Square Rectangular On Plain Or Polygonal, Complete All As Specified And Directed. 111 M&L For Providing Precast Cement Concrete ( 1:2:4 ) , Type B-1 ( Using 20Mm Graded Stone Aggregate ) As In Landings, Cover Slabs ( For Man Holes, Drain Etc. ) Chullah Hoods, Chajjas, Water Troughs, Mangers, Shelves And Similar Articles With Plain Faces With Plain Fair Faces, Including Chamfers, Weatherings, Throating Etc. And Set In Cement Mortar ( 1:4 ) , Complete With Joints To Match The Surface, Complete All As Specified And Directed. 112 M&L For Mild Steel Tmt Bars 10 Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hookingends And Binding With Mild Steelwire ( Annealed ) Not Less Than 0.9 Mm Dia Or Securing With Clips, Complete All As Specified And Directed. 113 M&L For Mild Steel Tmt Bars 5Mm Dia And Over Upto And Including 10Mm Dia In Stirrups, Spacers And Binders, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips, All As Specified And As Directed. 114 M&L For Reinforced Cement Concrete ( Nominal Mix ) ( 1:2:4 ) , Type B1 ( Using 20 Mm Graded Stone Aggregate ) As In Columns, Pillars, Piers, Posts And Struts, Complete All As Specified And Directed. 115 S&F In Repair Of Curtain Rails / Harrison Rails, Mild Steel, Chromium Plated With Fixing Brackets, Stops, Rollers Etc., Complete All As Specified And Directed. 116 Taking Down Copper / Aluminium Point Wiring ( Light, Fan, Socket Or Power ) Complete, Including Fixture And Fittings Such As Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fitting Etc. Removing Materials To Store For Keeping In Safe Custody Or For Taking Credit ( Credit For Above Items Should Be Made As Per Conditions Separately ) And Making Good Disturbed Surfaces Of Walls, Floors, Etc., Complete All As Specified And Directed. 117 Taking Down Carefully Sub Main Wiring Of Any Size / Core / Type Including Conduit / Cashing / Batten Of Any Type And Making Good Disturbed Surfaces To Match With The Existing Surface Roof / Wall / Floor, Complete All As Specified And Directed. 118 M&L For Point Wiring With 1.5 Sq.Mm ( Nominal Area ) Pvc Insulated Sheathed Single Core Multi Stranded Copper Conductor Frlsh Cable 1100 Volts Grade ( Conforming To Is ) Drawn Through And Includingrigidnonmetallic Pvc Conduit Not Less Than 20Mm Dia ( Concealed ) , Medium Grade With All Necessary Fittings, Concealed Wiring For Light / Fan / Bell On Independent Board, Point Controlled By One Switch Including 1.5 Sq Mm Pvc Frlsh Insulated Copper Stranded Conductor For Earth Continuity Conductor And Connected To Earth Dolly And To Be Terminated In 1.60 Mm Thick Pressed Steel Terminal Boxes Including Flush Metal Box 2 / 4 / 6 / 8 / 12 Module With Module Inner And Outer Plates For Mounting Moduler Switches, Socket Outlet, Regulator Etc. With 3 Mm Thick Laminated Bakelite Sheet Cover For Housing Switches, Socket Outlet, Regulator Etc., Complete All As Specified And Directed Including Testing On Completion.Notes: ( A ) Proper Colour Coding Of Pvc Insulated Copper Wire Should Be Maintained As Red / Yellow / Blue Wires For Phases, Black Wire For Neutral And Green Wire For Earth. ( B ) Two Run Of 1.5 Sq.Mm For Phase And Neutral And One Run Of 1.5 Sq.Mm For Earth Wire. ( C ) Concealed Type In Permanent Bldg And Surface Type In Temporary Bldg Or As Directed. 119 M&L For Point Wiring With 1.5 Sq.Mm ( Nominal Area ) Pvc Insulated Sheathed Single Core Multi Stranded Copper Conductor Frlsh Cable 1100 Volts Grade ( Conforming To Is ) Drawn Through And Includingrigidnonmetallic Pvc Conduit Not Less Than 20Mm Dia ( Concealed ) , Medium Grade With All Necessary Fittings, Concealed Wiring For Light / Fan On Independent Board, Point Controlled By Two Way Switchs Including 1.5 Sq Mm Pvc Frlsh Insulated Copper Stranded Conductor For Earth Continuity Conductor And Connected To Earth Dolly And To Be Terminated In 1.60 Mm Thick Pressed Steel Terminal Boxes Including Flush Metal Box 2 / 4 / 6 / 8 / 12 Module With Module Inner And Outer Plates For Mounting Moduler Switches, Socket Outlet, Regulator Etc. With 3 Mm Thick Laminated Bakelite Sheet Cover For Housing Switches, Socket Outlet, Regulator Etc., Complete All As Specified And Directed Including Testing On Completion.Notes:- ( A ) Proper Colour Coding Of Pvc Insulated Copper Wire Should Be Maintained As Red / Yellow / Blue Wires For Phases, Black Wire For Neutral And Green Wire For Earth. ( B ) Three Run Of 1.5 Sq.Mm For Phase And Neutral And One Run Of 1.5 Sq.Mm For Earth Wire. ( C ) Concealed Type In Permanent Bldg And Surface Type In Temporary Bldg Or As Directed. 120 M&L For Point Wiring With 1.5 Sq.Mm ( Nominal Area ) Pvc Insulated Sheathed Single Core Multi Stranded Copper Conductor Frlsh Cable 1100 Volts Grade ( Conforming To Is ) Drawn Through And Includingrigidnonmetallic Pvc Conduit Not Less Than 20Mm Dia ( Concealed ) , Medium Grade With All Necessary Fittings, Concealed Wiring For One 3 Pin Socket Outlet 5 Amps On The Same Board With Other Switches Including 1.5 Sq Mm Pvc Frlsh Insulated Copper Stranded Conductor For Earth Continuity Conductor And Connected To Earth Dolly And To Be Terminated In 1.60 Mm Thick Pressed Steel Terminal Boxes Including Flush Metal Box 2 / 4 / 6 / 8 / 12 Module With Module Inner And Outer Plates For Mounting Moduler Switches, Socket Outlet, Regulator Etc. With 3 Mm Thick Laminated Bakelite Sheet Cover For Housing Switches, Socket Outlet, Regulator Etc., Complete All As Specified And Directed Including Testing On Completion.Notes: ( A ) Proper Colour Coding Of Pvc Insulated Copper Wire Should Be Maintained As Red / Yellow / Blue Wires For Phases, Black Wire For Neutral And Green Wire For Earth. ( B ) Two Run Of 1.5 Sq.Mm For Phase And Neutral And One Run Of 1.5 Sq.Mm For Earth Wire. ( C ) Concealed Type In Permanent Bldg And Surface Type In Temporary Bldg Or As Directed. 121 M&L For Point Wiring With 1.5 Sq.Mm ( Nominal Area ) Pvc Insulated Sheathed Single Core Multi Stranded Copper Conductor Frlsh Cable 1100 Volts Grade ( Conforming To Is ) Drawn Through And Includingrigidnonmetallic Pvc Conduit Not Less Than 20Mm Dia ( Concealed ) , Medium Grade With All Necessary Fittings, Concealed Wiring For One 3 Pin Socket Outlet, 5 Amps On Independent Board, Point Controlled By One Switch Including 1.5 Sq Mm Pvc Frlsh Insulated Copper Stranded Conductor For Earth Continuity Conductor And Connected To Earth Dolly And To Be Terminated In 1.60 Mm Thick Pressed Steel Terminal Boxes Including Flush Metal Box 2 / 4 / 6 / 8 / 12 Module With Module Inner And Outer Plates For Mounting Moduler Switches, Socket Outlet, Regulator Etc. With 3 Mm Thick Laminated Bakelite Sheet Cover For Housing Switches, Socket Outlet, Regulator Etc., Complete All As Specified And Directed Including Testing On Completion.Notes: ( A ) Proper Colour Coding Of Pvc Insulated Copper Wire Should Be Maintained As Red / Yellow / Blue Wires For Phases, Black Wire For Neutral And Green Wire For Earth. ( B ) Two Run Of 1.5 Sq.Mm For Phase And Neutral And One Run Of 1.5 Sq.Mm For Earth Wire. ( C ) Concealed Type In Permanent Bldg And Surface Type In Temporary Bldg Or As Directed. 122 M&L For Point Wiring With 2.5 Sq.Mm ( Nominal Area ) Pvc Insulated Sheathed Single Core Multi Stranded Copper Conductor Frlsh Cable 1100 Volts Grade ( Conforming To Is ) Drawn Through And Includingrigidnonmetallic Pvc Conduit Not Less Than 25Mm Dia ( Concealed ) , Medium Grade With All Necessary Fittings, Concealed Wiring For One 3 / 5 Pin Socket Outlet, 5 / 15 Amps On Independent Board, Point Controlled By One Switch Including 2.5 Sq Mm Pvc Frlsh Insulated Copper Stranded Conductor For Earth Continuity Conductor And Connected To Earth Dolly And To Be Terminated In 1.60 Mm Thick Pressed Steel Terminal Boxes Including Flush Metal Box 2 / 4 / 6 / 8 / 12 Module With Module Inner And Outer Plates For Mounting Moduler Switches, Socket Outlet, Regulator Etc. With 3 Mm Thick Laminated Bakelite Sheet Cover For Housing Switches, Socket Outlet, Regulator Etc., Complete All As Specified And Directed Including Testing On Completion.Notes:- ( I ) Proper Colour Coding Of Pvc Insulated Copper Wire Should Be Maintained As Red / Yellow / Blue Wires For Phases, Black Wire For Neutral And Green Wire For Earth. ( B ) Two Run Of 2.5 Sq.Mm For Phase And Neutral And One Run Of 2.5 Sq.Mm For Earth Wire. ( C ) Concealed Type In Permanent Bldg And Surface Type In Temporary Bldg Or As Directed ) 123 M&L For Point Wiring With 1.5 Sq.Mm ( Nominal Area ) Pvc Insulated Sheathed Single Core Multi Stranded Copper Conductor Frlsh Cable 1100 Volts Grade ( Conforming To Is ) Drawn Through And Includingrigidnonmetallic Pvc Conduit Not Less Than 20Mm Dia ( Concealed ) , Medium Grade With All Necessary Fittings, Concealed Wiring For One Bell / Buzzer Point Controlled By One Push Button On The Same Board With Other Switches Or Independent Including 1.5 Sq Mm Pvc Frlsh Insulated Copper Stranded Conductor For Earth Continuity Conductor And Connected To Earth Dolly And To Be Terminated In 1.60 Mm Thick Pressed Steel Terminal Boxes Including Flush Metal Box 2 / 4 / 6 / 8 / 12 Module With Module Inner And Outer Plates For Mounting Moduler Switches, Socket Outlet, Regulator Etc. With 3 Mm Thick Laminated Bakelite Sheet Cover For Housing Switches, Socket Outlet, Regulator Etc., Complete All As Specified And Directed Including Testing On Completion.Notes: ( A ) Proper Colour Coding Of Pvc Insulated Copper Wire Should Be Maintained As Red / Yellow / Blue Wires For Phases, Black Wire For Neutral And Green Wire For Earth. ( B ) Two Run Of 1.5 Sq.Mm For Phase And Neutral And One Run Of 1.5 Sq.Mm For Earth Wire. ( C ) Concealed Type In Permanent Bldg And Surface Type In Temporary Bldg Or As Directed. 124 M&L For Modular Switch One Way 6 Amps, 1 Module, 240 Volts, All As Specified And Directed. 125 M&L For Modular Switch Two Way 6 Amps, 1 Module, 240 Volts, All As Specified And Directed. 126 M&L For Modular Bell Push 6 Amps 1 Module, 240 Volts, All As Specified And Directed. 127 M&L For Modular Socket, 6 Amps - 2 / 3 Pin Combined 2 Module, 240 Volts, All As Specified And Directed. 128 M&L For Modular Socket, 6Amps / 16Amps - 2 / 3 Pin Combined 2 Module, 240 Volts, All As Specified And Directed. 129 M&L For Modular Switch One Way 16 Amps, 1 Module, 240 Volts, All As Specified And Directed. 130 M&L For Ceiling Rose, 3 Phase / Pvc / Polycarbonate, Isolated Body, Three Terminal, 240 Volts, All As Specified And Directed. 131 M&L For Modular Blank Plate, 1 Module, 240 Volts, All As Specified And Directed. 132 M&L For Modular White Cover Plate With Frame, 2 Module, 240 Volts, All As Specified And Directed. 133 M&L For Modular White Cover Plate With Frame, 3 Module, 240 Volts, All As Specified And Directed. 134 M&L For Modular White Cover Plate With Frame, 4 Module, 240 Volts, All As Specified And Directed. 135 M&L For Modular White Cover Plate With Frame, 6 Module, 240 Volts, All As Specified And Directed. 136 M&L For Modular Metal Flush Box, 1 / 2 Module, 240 Volts, All As Specified And Directed. 137 M&L For Modular Metal Flush Box, 3 Module, 240 Volts, All As Specified And Directed. 138 M&L For Modular Metal Flush Box, 4 Module, 240 Volts, All As Specified And Directed. 139 M&L For Modular Metal Flush Box, 6 Module, 240 Volts, All As Specified And Directed. 140 M&L For Buzzer, Ding Dong Ac. 230 Volts, Single Pole, All As Specified And Directed. 141 Supply And Fixing In Repair / Replacement Of Led Tube Lights Fitting 4Feet, 1X 22W, 230V, Decorative Ultra Slim Extruded Aluminium Batten Fixure With High Lumen Output, Environmental Friendly, All As Specified And Directed. 142 Supply And Fixing In Repair / Replacement Of Decorative Box Type Fitting Suitable For 4Feet Led Tube Light, 1X 22W, 230V, Bipin Holder, Connector Block, Driver Etc. With All Accessories Internally Pre-Wired Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose And Pvc Square Blocks For Fixing Led Fittings, All As Specified And Directed. 143 M&L In Repair / Replacement Of Lamp Holder, Pvc / Polycarbonate Type With Back Plate Suitable For Batten Fittings, Complete All As Specified And Directed. 144 Supply And Fixing In Repair / Replacement Of Building Security Light Fittings New Generation Energy Saving And Enviornmental Friendly Long Life Versatile Pressure Die-Cast Aluminium Ip66 Protection With Acrylic Cover Of Led 35 Watts Luminaire Including Gi Bracket Of Suitable Size With Clamp, Complete All As Specified And Directed. 145 S&F Of Sub Main Wiring With Two Single Core 2.5 Sqmm Pvc ( Frlsh ) Copper Conductor, Insulated Multistranded Unsheathed Cable Medium Grade Including Pvc Conduit Concealed Of Required Size ( Not Less Than 32Mm ) Conforming To Is 2079-1973 With Accessories For Sub Main Connection Including 2.5 Sqmm Pvc ( Frlsh ) Insulated Multistranded Unsheathed Copper Conductor Used As A Earth Wire To Common Earth And Connection To Earth Dolly All As Specified And Directed. ( Note:- Three Runs Of 2.5 Sqmm Pvc Frlsh Copper Conductor Shall Be Measured As One Unit Length ) . 146 S&F Of Sub Main Wiring With Two Single Core 4.0 Sqmm Pvc ( Frlsh ) Copper Conductor, Insulated Multistrandedunsheathed Cable Medium Grade Including Pvc Conduit Concealed Of Required Size ( Not Less Than 32Mm ) With Accessories For Sub Main Connection Including 4.0 Sqmm Frlshinsulated Multistranded Unsheathed Copper Conductor Used As A Earth Wire To Common Earth And Connection To Earth Dolly, All As Specified And Directed. ( Note :-Three Runs Of 4.0 Sqmm Pvc Frlsh Copper Conductor Shall Be Measured As One Unit Length ) . 147 S&F Of Sub Main Wiring With Two Single Core 6.0 Sqmm Pvc ( Frlsh ) Copper Conductor, Insulated Multistranded Unsheathed Cable Medium Grade Including Pvc Conduit Concealed Of Required Size ( Not Less Than 32Mm ) With Accessories For Sub Main Connection Including 6.0 Sqmm Pvc ( Frlsh ) Insulated Multistranded Unsheathed Copper Conductor Used As A Earth Wire To Common Earth And Connection To Earth Dolly All As Specified And Directed. ( Note:- Three Runs Of 6.0 Sqmm Pvc Frlsh Copper Conductor Shall Be Measured As One Unit Length ) . 148 Supply And Fixing In Repair / Replacement Of Triple Pole And Neutral ( Tpn ) Db With Sheet Metal Enclosure, 4 Way, Double Door, 415 Volt Suitable For Mounting Incoming And Outgoing Mcbs, Complete All As Specified And Directed. 149 Supply And Fixing In Repair / Replacement Of Sheet Metal Enclosure, Double Door For Mcb DbS, 8 Way Single Pole & Neutral ( Spn ) And Current Carrying Capacity Of 200 Amps Rated Bus Bar Suitable For 240 Volt, Ac, 50Hz, Complete All All As Specified And Directed. 150 Supply And Fixing In Repair / Replacement Of 240V, 10Ka C Curve Miniature Circuit Breaker ( Mcb ) Of Single Pole ( Sp ) And Current Carrying Capacity Of 5 To 32 Amp Duly Fixed With Lugs / Sockets / Thimbles Etc. In The Mcb Db Complete With Connection Testing And Commissioning, Complete All All As Specified And Directed. 151 Supply And Fixing In Repair / Replacement Of 240V, 10Ka C Curve Miniature Circuit Breaker ( Mcb ) Of Single Pole & Neutral ( Spn ) And Current Carrying Capacity Of 32 Amps Duly Fixed With Lugs / Sockets / Thimbles Etc. In The Mcb Db Complete With Connection Testing And Commissioning, All As Specified And Directed. 152 Supply And Fixing In Repair / Replacement Of 240V, 10Ka C Curve Miniature Circuit Breaker ( Mcb ) Of Single Pole & Neutral ( Spn ) And Current Carrying Capacity Of 40 To 63 Amp Duly Fixed With Lugs / Sockets / Thimbles Etc. In The Mcb Db Complete With Connection Testing And Commissioning, All As Specified And Directed. 153 Supply And Fixing In Repair / Replacement Of 240V, 10Ka C Curve Miniature Circuit Breaker ( Mcb ) Of Four Pole ( Fp ) And Current Carrying Capacity Of 63 Amp Duly Fixed With Lugs / Sockets / Thimbles Etc. In The Mcb Db Complete With Connection Testing And Commissioning, All As Specified And Directed. 154 Material And Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 60Cm × 60Cm× 6Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level ) With Top Edge Of The Plate Not LessThan 1.5 Metres Below Normal Ground Level, Connected To Galvanised Iron Or Steel Earth Lead Wire 4.0Mm Dia Size By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron Or Steel All As Shown In Electrical Plate No. 3 Ofmesssrpart-I, Connected To Earthing Test Point All As Specified Or Indicated Including Testing On Completion, Includingnecessary Excavation And Earth Work In Any Type Of Soil, Gi Pipe 20Mm Dia Light Grade For Watering And Gi 15Mm Dia Light Grade Pipe For Protection Of Earth Wire Etc. Upto Test Point, Pcc Chamber With Pcc Cover In Cement Concrete ( 1:2:4 ) Type B-1 ( Using 20Mm Graded Stone Aggregate ) , Funnel, Wire Mesh, Charcoal Dust, Salt Etc, Connected To Db As Indicated, Complete All As Specified And As Directed.Notes: Contractor Should Conduct Necessary Test Such As Earth Continuity, Earth Resistance Test In Presence Of Engineer-In-Charge. 155 Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Laying Of Underground Cables Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Under Groung Cables Etc. N Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out In Soft / Loose Soil, Complete All As Specified And Directed. 156 M&L For Sand Filling Under Floors Or In Foundations Or For Protection Of Cable Etc. Including Watering And Consolidation, Complete All As Specified And Directed. 157 Supply And Laying Of Old Size Burnt Clay Fly Ash Building Bricks Designation 75 ( Kg / Cm2 ) Laid Flat Equal To Width Of Bricks, Perpendicular To Under Ground ( Ug ) Cable Over The Dry Sand Cushioning, For Cable Protection, Complete All As Specified And Directed. 158 Dismantling / Taking Out Old Unserviceable Service Connection Cables / Under Groung Cables, Of Any Grade / Type Of Size As Below From Pole / Wall / Cable Duct / Under Ground Trench Etc, All As Specified And Directed. 159 Supply And Laying In Trenches, Fixed To Wall / Pole Xlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, 4.0 Core, Cross-Sectional Area 16 Sq.Mm, Complete All As Specified And Directed. 160 Supply And Laying In Trenches, Fixed To Wall / Pole Xlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, 4.0 Core, Cross-Sectional Area 25 Sq.Mm, Complete All As Specified And Directed. 161 M&L For 40Mm Dia Steel Tubes ( Light Grade ) Galvanised With All Fittings, Laid In Trenches / Wall / Pole / Road Crossing For Protection Of Underground Cable / Earth Strip, All As Specified And Directed. 162 M&L For Cutting Existing Road / Hard Standing Not Exc 20X30 Cm In Wide And Depth Getting Out Excavated Material For Laying Cable / Gi Tube, Returning Filling And Well Ramming Wateringfinish Suraface 10 Cm From Top Using Pcc 1:3:6; Including Removal Of Surplase Soil, All As Specified And Directed. 163 Note 1:- ( Applicable For All Parts / Items ) : The Bidders / Contractors Are Advised To Read Tender Document, All Drawings & All Corrigendum / Amendments And General Condition Of Contracts Before Entry / Quoting The Rates.Note 2:-The Contract Sum Shall Be Arrived At After Deducting Amount Of Schedule Of Credit From The Total Quoted Amount.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-11-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 131000.0 /-
Tender Value
INR 70.29 Lakhs /-

BOQ Items

Name of Work: SPL REPAIR TO BLDG NO. P-95 (OR MD ACCN) AT LEBONG UNDER AGE(I) DARJEELING.
Sl. No. Item Description
1Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
2S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
3S&F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
4Add to item 2.00 & 3.00 here-in-before if fixed with L-type or J-type or cranked hook bolts in lieu of screw, complete all as specified and directed.
5Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
6S&F of mild steel hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding inconcrete and screwing etc. wind ties for roof including securing bolts conforming to Fe-290 Gde E-165, complete all as specified and directed
7S&F of framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under "Structural Steel"), complete all as specified and directed.
8Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., complete all as specified and directed.
9M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cement mortar (1:6) finished even and rough, complete all as specified and directed.
10M&L for non-skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles, complete all as specified and directed.
11M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles, complete all as specified and directed.
12M&L for machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed.
13M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments, complete all as specified and directed.
14M&L for rendering 10mm thick in cement mortar (1:3) on fair faces of brick work or concrete surfaces, complete all as specified and directed.
15M&L for coloured glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface of tiles, complete all as specified and directed.
16Taking down cement or cement lime plaster, any description on brick or stone masonrysurfaces of walls etc includingrakingout joints, hackingfor key, scrubbingdown with wateretc, complete all as specified and directed.
17M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra lime or cement), complete all as specified and directed.
18M&L for rendering 15mm thick in cement mortar (1:4) with water proofing compound @ 3% by weight of cement or in the manner specified by the manufacturer and in the proportions indicated on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra lime or cement), complete all as specified and directed. Note: Water proofing compound will be measured and paid separately.
19M&L for 5mm thick rendering in cement mortar (1:3) on concrete surfaces in ceilings and finished even and smooth (without using extra lime or cement), complete all as specified and directed.
20Supply only integral water proofing compond, all as specified and as directed.
21M&L for preparation of new plastered or unplastered surface of wall and applying two coats of distemper oil emulsion (OBD), over acoat of priming coat (Chalk whiting, on plastered surfaces, prepara-tory to distempering) including 3mm thick wall care putty on wall, complete all as specified and directed.
22M&L forpreparation of new plastered or unplastered surface of ceiling and applying one coat of oil bound distemper (distemper oil-emulsion) over a coat of priming coat (Chalk whiting, on plastered surfaces, preparatory to distempering) including 1mm thick wall care putty on ceiling, complete all as specified and directed.
23M&L forpreparation of new plastered or unplastered surface of wall and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed.
24M&L for complete removal of existing treatment on plastered or unplastered surface of wall including brooming down or steel wire brushing, scrapping down smoke scoot, mould, moss and efflorescent salt, trading oil and greasy spot and applying one coat 1mm thick of wall care putty and then applying two coats of distemper oil emulsion(OBD), white or tinted over a coat of priming coat (Chalk whiting, on plastered surfaces, preparatory to distempering) after preparation of wall surfaces, complete all as specified and directed.
25M&L for complete removal of existing treatment on plastered or unplastered surface of ceiling including brooming down or steel wire brushing, scrapping down smoke scoot, mould, moss and efflorescent salt, trading oil and greasy spot and applying one coat of oil bound distemper (distemper oil-emulsion) over acoat of priming coat (Chalk whiting, on plastered surfaces, preparatory to distempering) including 1mm thick layer of wall care putty on ceiling after preparation of wall surfaces, complete all as specified and directed.
26M&L for complete removal of existing treatment on plastered or unplastered surface of wall including brooming down or steel wire brushing, scrapping down smoke scoot, mould, moss and efflorescent salt, trading oil and greasy spot and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed.
27M&L for preparation of old decorated plastered or unplastered surfaces of wall including brooming down or steel wire brushing, scrapping down smoke scoot, mould, moss and efflorescent salt, trading oil and greasy spot and applying and applying two coats of white wash on walls, complete all as specified and directed.
28M&L for preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed.
29M&L for preparation of new wooden or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
30M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed.
31M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed.
32Taking up or downold 15 mm bore steel water tubing and connections, including cleaning for refixing or removal to store or from site, complete all as specified and directed.
33Taking up or down old 20 mm bore steel water tubing and connections, including cleaning for refixing or removal to store or from site, complete all as specified and directed.
34S&F of 15 mm bore steel water tubes, medium grade, galvanised with and including all GI fitting (such as bends, elbows, Tees, connectors, short pieces,back nuts, unions, caps and plug etc ) and fixed complete to wall and ceilingor laid in/on floor, complete all as specified and directed.
35S&F of 20 mm bore steel water tubes, medium grade, galvanised with and including all GI fitting (such as bends, elbows, Tees, connectors, short pieces,back nuts, unions, caps and plug etc ) and fixed complete to wall and ceilingor laid in/on floor, complete all as specified and directed.
36Refixing old 15 mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed.
37Refixing old 20 mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed.
38S&F of 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed.
39S&F in repair of 15mm bore dia bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
40S&F in repairs of 15mm bore dia stop valves, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
41S&F of water closet (squatt pattern) of vitreous china squatting pan of pattern "ORRISA" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe etc complete including P or S trap set in and including necessary lean cement concrete, complete all as specified and directed.
42S&F of vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and making good the floor, complete all as specified and directed.
43S&F of 100mm bore of pipe ‘P’ or ‘S’ traps without vent horn, complete all as specified and directed.
44S&F of PVClow level flushing cistern 10 litre capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS:2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type, complete all as specified and directed.
45S&F of PVC connections 15mm size with PTMT nuts of length 450mm, all as specified and directed.
46S&F of towel rail 450mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms), complete all as specified and directed.
47S&F of grating doom 100mm dia of PTMT (Minimum weight 25gms), complete all as specified and directed.
48S&F of 1mm thick stainless steel sink with drainage board kitchen or laboratory type with waste pipe, plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size of sink 915mm x 460mm and bowl size 410mm x 330mm x 160mm, complete all as specified and directed.
49Dismantling water tanks of capacity exc 500 and n exc 1000 litres and removing to store, complete all as specified and directed.
50S&F of rotational moulded polyethylene water storage tanks of capacity 1000 litres (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-l and directed.
51S&F in repairs of 20 mm bore dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20 mm - 210 gms. / 25mm-455gms/ 40mm - 690 gms), complete all as specified and directed.
52Supplied and fixed in repair of 15 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
53Supplied and fixed in repair of 20 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
54Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed.
55S&F of anodised aluminium snap grid frame work of size of grid 605mm x 605mm for false ceiling, complete all as specified and directed.
56M&L for 4mm thick non asbestos fibre cement building boards fixed or laid / inserted to timber / GI / aluminium framework with screws in ceiling flat or sloping, complete all as specified and directed.
57Demolition and breaking up drain pipes (PVC (SWR), Salt glazed ware, AC or Reinforced concrete) of 150mm bore including accessories set in cement mortar and removing rubbish from site, complete all as specified and directed.
58Demolition and breaking up drain pipes (PVC (SWR), Salt glazed ware, AC or Reinforced concrete) of100mm bore including accessories set in cement mortar and removing rubbish from site, complete all as specified and directed.
59M&L for 150mm internal diameter salt-glazed stoneware drain pipes laid in trenches and jointed all as specified and directed.
60M&L for 100mm internal diameter salt-glazed stoneware drain pipes laid in trenches and jointed all as specified and directed.
61M&L for plain cement concrete (1:4:8) bed, type D-2, (using 40mm graded stone aggregate) to drain pipes 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed.
62M&L for plain cement concrete (1:4:8) bed, type D-2, (using 40mm graded stone aggregate) to drain pipes 100mm bore including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed.
63Dismantling of 100mm dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required, complete all as specified and directed.
64M&L for 100mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and directed.
65M&L for 100mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls, complete all as specified and directed.
66S&F of 100mm bore dia cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors, complete all as specified and directed.
67S&F of 100mm bore dia cast iron cowls, complete all as specified and directed.
68Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness(below or above ground level), complete all as specified and directed.
69M&L for 75 mm thick plain cement concrete(1:3:6), type C-2(40 mm graded stone aggregate) as in plinth protection, hard standing, path etc including finish the surface even and smooth without using extra cement, complete all as specified and directed.
70M&L for 40mm thick plain cement concrete(1:2:4), type B-1, (using 20mm graded stone aggregate) as in sub-base, sub-floors, floors, pavings, roof treatment etc., complete all as specified and directed.
71M&L for hardcore using broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
72Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
73M&L for brickwork with fly ash bricks(old size bricks), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6), complete all as specified and directed.
74M&L for plain cement concrete(1:3:6), type C-2(40 mm graded stone aggregate) in surface channels and drains, complete all as specified and directed.
75M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds mitered / stopped ends etc all as specified and as directed.
76Taking down chowkhatsor frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame), complete all as specified and directed.
77Taking down chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frame), complete all as specified and directed.
78Taking down shutters of any description n exc 1 sq. m each, complete all as specified and directed.
79Taking down shutters of any description exc 1 sq. m and n exc 2 sq. m each, complete all as specified and directed.
80Dismantling timber scantlings 40 Sqcm and over in section, in any position (unframed work), all as specified and directed.
81S&F of second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
82M&L for preparing surfaces of wood and wood based materials, new or old of any description and girth, not otherwise described and treated with one coat of creosote oil, complete all as specified and directed.
83M&L for second class hard wood, 35mm thick plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and directed.
84S&F of 35 mm thick (batten thickness) second class hard wood,glazed and skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and rebated sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats completeall as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)
85M&L for second class hard wood, 30mm thick glazed and skeleton windows shutters, ventilators shutters etc. are provided with stiles and rails, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24(b); supplied and fitted to chowkats, complete all as specified and directed.
86S&F of solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed.
87S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing and as directed.
88S&F of 100mm size butt hinges, medium weight, cold rolled mild steel, and fixed, all as specified and directed.
89S&F of 75mm size butt hinges, medium weight, cold rolled mild steel, and fixed, all as specified and directed.
90S&F of 125 mm size aluminium handles, cast type, anodised, all as specified and directed.
91S&F of 100mm size aluminium handles, cast type, anodised, all as specified and directed.
92S&F of 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed, all as specified and directed.
93S&F of 125mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, all as specified and directed.
94S&F of 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, all as specified and directed.
95Hacking out old broken glass, exc 1.5 sqm (any thickness, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed.
96S&F of 3.0mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed.
97S&F of 3.0mm thick sheet glass ground or obscured or frosted, on one side, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed.
98S&F in repairs galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed.
99S&F of bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed.
100M&L for plain cement concrete (1:3:6), type C1 (using 20mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
101S&F in repair of small fittings such as brackets of any type latch and hinge block, shaped door window stops and the like in second class hard wood article not exc 200 cucm each, complete all as specified and directed.
102Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed.
103S&F of 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
104S&F of 110mm bore PVC (SWR) bends any radius, complete all as specified and directed.
105Rough excavation not exceeding 1.5 m deep and getting out in soft / loose soil, all as specified and directed.
106Returning filling in soft / loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
107Removal of surplus excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
108M&L for plain cement concrete (1:2:4), type B-0(using 12.5 mm graded stone aggregates)in coping, bed plates, parepet, plinth course including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
109Demolition ofreinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not specifically provided for, complete all as specified andas directed.
110Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete on square rectangular on plain or polygonal, complete all as specified and directed.
111M&L for providing precast cement concrete (1:2:4), type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs (for man holes, drain etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces with plain fair faces, including chamfers, weatherings, throating etc. and set in cement mortar (1:4), complete with joints to match the surface, complete all as specified and directed.
112M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookingends and binding with mild steelwire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
113M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and as directed.
114M&L for reinforced cement concrete (nominal mix)(1:2:4), type B1 (using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts, complete all as specified and directed.
115S&F in repair of curtain rails / harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc., complete all as specified and directed.
116Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.
117Taking down carefully sub main wiring of any size/core/type including conduit/ cashing/ batten of any type and making good disturbed surfaces to match with the existing surface roof/ wall/ floor, complete all as specified and directed.
118M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and includingrigidnonmetallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring for light / Fan / Bell on independent board, point controlled by one switch including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes: (a) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed.
119M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and includingrigidnonmetallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring for light / Fan on independent board, point controlled by two way switchs including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes:- (a) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Three run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed.
120M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and includingrigidnonmetallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring for one 3 pin socket outlet 5 amps on the same board with other switches including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes: (a) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed.
121M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and includingrigidnonmetallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring for one 3 pin socket outlet, 5 amps on independent board, point controlled by one switch including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes: (a) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed.
122M&L for point wiring with 2.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and includingrigidnonmetallic PVC conduit not less than 25mm dia (concealed), medium grade with all necessary fittings, concealed wiring for one 3 / 5 pin socket outlet, 5 / 15 amps on independent board, point controlled by one switch including 2.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes:- (i) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 2.5 Sq.mm for phase and neutral and one run of 2.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed)
123M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and includingrigidnonmetallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or independent including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes: (a) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed.
124M&L for modular switch one way 6 Amps, 1 module, 240 Volts, all as specified and directed.
125M&L for modular switch two way 6 Amps, 1 module, 240 Volts, all as specified and directed.
126M&L for modular bell push 6 Amps 1 module, 240 Volts, all as specified and directed.
127M&L for modular socket, 6 Amps - 2/3 pin combined 2 module, 240 Volts, all as specified and directed.
128M&L for modular socket, 6Amps / 16Amps - 2/3 pin combined 2 module, 240 Volts, all as specified and directed.
129M&L for modular switch one way 16 Amps, 1 module, 240 Volts, all as specified and directed.
130M&L for ceiling rose, 3 phase/PVC/ polycarbonate, isolated body, three terminal, 240 Volts, all as specified and directed.
131M&L for modular blank plate, 1 module, 240 Volts, all as specified and directed.
132M&L for modular white cover plate with frame, 2 module, 240 Volts, all as specified and directed.
133M&L for modular white cover plate with frame, 3 module, 240 Volts, all as specified and directed.
134M&L for modular white cover plate with frame, 4 module, 240 Volts, all as specified and directed.
135M&L for modular white cover plate with frame, 6 module, 240 Volts, all as specified and directed.
136M&L for modular metal flush box, 1/2 module, 240 Volts, all as specified and directed.
137M&L for modular metal flush box, 3 module, 240 Volts, all as specified and directed.
138M&L for modular metal flush box, 4 module, 240 Volts, all as specified and directed.
139M&L for modular metal flush box, 6 module, 240 Volts, all as specified and directed.
140M&L for Buzzer, Ding Dong AC. 230 volts, single pole, all as specified and directed.
141Supply and fixing in repair / replacement of LED tube lights fitting 4feet, 1x 22W, 230V, decorative ultra slim extruded aluminium batten fixure with high lumen output, environmental friendly, all as specified and directed.
142Supply and fixing in repair / replacement of decorative box type fitting suitable for 4feet LED Tube light, 1x 22W, 230V, bipin holder, connector block, driver etc. with all accessories internally pre-wired connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and PVC square blocks for fixing LED fittings, all as specified and directed.
143M&L in repair / replacement of lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
144Supply and fixing in repair / replacement of building security light fittings new generation energy saving and enviornmental friendly long life versatile pressure die-cast aluminium IP66 protection with acrylic cover of LED 35 Watts luminaire including GI bracket of suitable size with clamp, complete all as specified and directed.
145S&F of sub main wiring with two single core 2.5 Sqmm PVC (FRLSH) copper conductor, insulated multistranded unsheathed cable medium grade including PVC conduit concealed of required size (not less than 32mm) conforming to IS 2079-1973 with accessories for sub main connection including 2.5 Sqmm PVC (FRLSH)insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified and directed. (Note:- Three runs of 2.5 sqmm PVC FRLSH copper conductor shall be measured as one unit length).
146S&F of sub main wiring with two single core 4.0 Sqmm PVC (FRLSH) copper conductor, insulated multistrandedunsheathed cable medium grade including PVC conduit concealed of required size (not less than 32mm) with accessories for sub main connection including 4.0 Sqmm FRLSHinsulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly, all as specified and directed. (Note :-Three runs of 4.0 sqmm PVC FRLSH copper conductor shall be measured as one unit length).
147S&F of sub main wiring with two single core 6.0 Sqmm PVC (FRLSH) copper conductor, insulated multistranded unsheathed cable medium grade including PVC conduit concealed of required size (not less than 32mm) with accessories for sub main connection including 6.0 Sqmm PVC (FRLSH)insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified and directed. (Note:- Three runs of 6.0 sqmm PVC FRLSH copper conductor shall be measured as one unit length).
148Supply and fixing in repair / replacement of triple pole and neutral (TPN) DB with sheet metal enclosure, 4 way, double door, 415 volt suitable for mounting incoming and outgoing MCBs, complete all as specified and directed.
149Supply and fixing in repair / replacement of sheet metal enclosure, double door for MCB DB"s, 8 way single pole & neutral (SPN) and current carrying capacity of 200 amps rated bus bar suitable for 240 Volt, AC, 50Hz, complete all all as specified and directed.
150Supply and fixing in repair / replacement of 240V, 10KA "C" curve miniature circuit breaker (MCB) of single pole (SP) and current carrying capacity of 5 To 32 AMP duly fixed with lugs / sockets / thimbles etc. in the MCB DB complete with connection testing and commissioning, complete all all as specified and directed.
151Supply and fixing in repair / replacement of 240V, 10KA "C" curve miniature circuit breaker (MCB) of single pole & neutral (SPN) and current carrying capacity of 32 Amps duly fixed with lugs / sockets / thimbles etc. in the MCB DB complete with connection testing and commissioning, all as specified and directed.
152Supply and fixing in repair / replacement of 240V, 10KA "C" curve miniature circuit breaker (MCB) of single pole & neutral (SPN) and current carrying capacity of 40 to 63 AMP duly fixed with lugs / sockets / thimbles etc. in the MCB DB complete with connection testing and commissioning, all as specified and directed.
153Supply and fixing in repair / replacement of 240V, 10KA "C" curve miniature circuit breaker (MCB) of four pole (FP) and current carrying capacity of 63 AMP duly fixed with lugs / sockets / thimbles etc. in the MCB DB complete with connection testing and commissioning, all as specified and directed.
154Material and labour for earthing complete with galvanised steel earth plate electrode 60cm × 60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised iron or steel earth lead wire 4.0mm dia size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 ofMESSSRPart-I, connected to earthing test point all as specified or indicated including testing on completion,includingnecessary excavation and earth work in any type of soil, GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of earth wire etc. upto test point, PCC chamber with PCC cover in cement concrete (1:2:4)type B-1 (using 20mm graded stone aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to DB as indicated, complete all as specified and as directed. Notes: Contractor should conduct necessary test such as earth continuity, earth resistance test in presence of Engineer-in-Charge.
155Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying of underground cables etc. or for shafts, wells, cesspits, manholes, pier holes, under groung cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil, complete all as specified and directed.
156M&L for sand filling under floors or in foundations or for protection of cable etc. including watering and consolidation, complete all as specified and directed.
157Supply and laying of old size burnt clay fly ash building bricks designation 75(Kg/cm2) laid flat equal to width of bricks, perpendicular to under ground (UG) cable over the dry sand cushioning, for cable protection, complete all as specified and directed.
158Dismantling/Taking out old unserviceable service connection cables / under groung cables, of any grade / type of size as below from pole/ wall/ cable duct/ under ground trench etc, all as specified and directed.
159Supply and laying in trenches, fixed to wall / pole XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 4.0 core, cross-sectional area 16 sq.mm, complete all as specified and directed.
160Supply and laying in trenches, fixed to wall / pole XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 4.0 core, cross-sectional area 25 sq.mm, complete all as specified and directed.
161M&L for 40mm dia steel tubes (light grade) galvanised with all fittings, laid in trenches/wall/pole/road crossing for protection of underground cable/ earth strip, all as specified and directed.
162M&L for cutting existing road/ hard standing not exc 20x30 cm in wide and depth getting out excavated material for laying cable/ GI tube, returning filling and well ramming wateringfinish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil, all as specified and directed.
163Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
Disclaimer :